CS Paper Radar

Ground Truth Bias in AI-Assisted Medical Annotation: A Crossover Study Using an Independent Radiologist Reference Standard

Márton Baltay, Tamás Ilcsik, Márton Borbély

cs.HC ·submitted 2026-11-19 11:08 UTC · v1

Abstract

Behavioural evaluations of artificial-intelligence-assisted annotation score every human decision against a reference standard, so their conclusions inherit that standard's validity. We tested how far conclusions about assistance, reliance and individual differences depend on it. Fifty-one non-expert high-school students annotated 50 knee radiographs for osteoarthritis, with and without a deliberately imperfect classifier, in a crossover design; personality and non-verbal reasoning were also measured. Decisions were scored against the public repository labels and against an independent reference standard from a radiologist panel, which graded 23 of the 50 images as indeterminate. Against the repository labels, assistance raised accuracy from 60.4% to 65.3% (odds ratio 1.23, p=0.002). Against the independent standard, the gain on the 27 determinate images was smaller and not significant in the primary model (78.4% to 80.8%; odds ratio 1.16, p=0.178). The apparent benefit had been concentrated on the indeterminate images and was not significant when those images were assigned to either class. The direction of residual over-reliance depended on how indeterminate cases were handled, and the personality trait most strongly associated with accuracy changed identity and sign between standards. Reliance measures are only as valid as the reference standard that defines when the assistant is right.

Closest papers

Nearest neighbours by meaning across the whole index.

RadRef: A Reference-Free Metric for Radiology Report Generation

cs.LG ·2026-11-09 ·Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin +1 more
similarity 0.65
Abstract

AI-generated radiology reports are commonly evaluated against radiologist-authored references, limiting the applicability of standard reference-based metrics when no reference is available. We introduce RadRef, a reference-free metric that scores report claims against image-derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. By evaluating findings beyond the report's stated claims, RadRef assesses omissions as well as unsupported assertions. On ReXVal, RadRef achieves $73.1\%$ agreement with radiologist rankings among non-tied same-radiograph report pairs, with $61.8\%$ pair coverage and $64.3\%$ tie-inclusive agreement. Its non-tied agreement is close to GREEN ($73.9\%$) and RadFact ($72.6\%$), with its strongest relative results on omissions. We further evaluate $100$ model-generated and $100$ radiologist-authored reports from $100$ MIMIC-CXR studies, independently annotated by two board-certified radiologists. On same-image omission rankings, RadRef attains Kendall's $τ_b = 0.295$, compared with $0.386$ between the readers. In separate paired comparisons across generated reports, no evaluated comparator significantly outperforms RadRef on omissions. The same image-grounded representation provides a false-finding readout, RadRef-FF, with $τ_b = 0.32$ on ReXVal and $0.29$ in the reader study. Controlled perturbations confirm that RadRef depends on the radiograph, report, and clinical indication. RadRef enables image-grounded evaluation before a radiologist-authored reference exists, supporting quality monitoring of report-generation systems in clinical settings, and complements reference-based metrics when one is available.

0.17

Report-Derived Labels, an Image Teacher and the Gap to Expert Labels in Knee MRI: An Analysis of One Entry to the RSNA 2026 Knee Abnormality Detection Challenge

eess.IV ·2026-10-28 ·Soheil Kooklan
benchmarkcode/data similarity 0.61
Abstract · 24 pages, 10 figures, 14 tables. Code: https://github.com/soheilkooklan/rsna-knee-report-labels

In the RSNA 2026 Knee Abnormality Detection challenge, 58 of 4,407 training studies have expert labels for 12 findings, and the rest have only a radiology report. We compare training targets built from a language-model reading of the reports and from a public image model against two references: the expert labels and the 39,248 study-finding cells that the reports state as present or absent. The report labels and the out-of-fold predictions of the image model reach similar agreement with the expert labels (macro AUC 0.892 and 0.896) but fail on different findings. The report is better for ligament tears and patellofemoral osteoarthritis, which it never calls present when the experts do not; the image model is better for effusion, Baker's cyst, contusion, and synovitis, where the reports call the finding absent, leave it out, or call it present more often than the experts. Their equal mixture reaches 0.927 (gain over the report labels 0.035, 95% interval 0.019 to 0.052), also after removing the studies whose knee side was handled inconsistently. We did not observe a model-level gain from this better target: a 2.5D ResNet50 trained on the report labels alone scored 0.877 on the private leaderboard, after the deadline, against 0.872 for the same model trained on the mixture, and the out-of-fold advantage of the mixture is confounded by a change of code and by possible leakage through the image model's folds. A scanner prevalence prior raised agreement with the reports but not with the experts, so a report-derived reference can reward reporting habits. A rank correction for co-occurring findings gave small out-of-fold gains and no visible leaderboard effect. Our entry, a forked public ensemble with that correction, was displayed at rank 582 of 6,299 on the private leaderboard (0.943, a score shared by 287 teams). All results are exploratory; none of the models is meant for clinical use.

0.41

Dual- versus Single-Suggestion AI Support for Radiographic Interpretation in Residents: Randomized Multireader Study

cs.AI cs.CY ·2026-10-07 ·Lin Wu, Zhe Xu, Hongyi Wang, Feifei Zhou, Wei Deng +8 more
similarity 0.60
Abstract

Purpose: To compare dual- and single-suggestion AI support for radiographic interpretation by residents, particularly when the shared AI suggestion was incorrect. Materials and Methods: This prospective, multicenter, randomized three-arm reader study was conducted at three hospitals in China from July to September 2026 (ChiCTR2600129243). After specialty stratification, 132 residents with fewer than 3 years of clinical experience were randomized 1:1:1 to GPT-5.4 alone (group A), GPT-5.4 plus Kimi-K2.6 (group B), or GPT-5.4 plus Gemini-3.6 Flash (group C); 123 were analyzed. Participants interpreted 60 radiographs before and after AI support. The primary outcome was accuracy change. Welch ANOVA and Holm-adjusted t tests compared support conditions; HC3 linear models assessed specialty interaction. Results: Among 123 residents (mean age, 24.1 years +/- 1.4; 65 women), radiology residents showed greater accuracy improvement with dual- than single-suggestion support (B-A, 6.69 percentage points [95% CI, 0.97-12.40]; C-A, 7.87 percentage points [95% CI, 1.64-14.11]; Holm-adjusted P = .030 for both), whereas accuracy change did not differ in non-radiology residents (P = .20). When GPT-5.4 was incorrect, AI-assisted accuracy was higher with dual- than single-suggestion support in radiology residents (40.1% and 40.4% vs 20.0%) and non-radiology residents (31.3% and 31.0% vs 12.1%) (all Holm-adjusted P < .001). The dual-suggestion effect differed by specialty (interaction difference, 10.44 percentage points; 95% CI, 4.36-16.52; P < .001). Conclusion: Dual-suggestion support may mitigate the influence of erroneous AI suggestions, with greater accuracy improvement observed in radiology but not non-radiology residents.

0.25

When Repository Labels Are Not Image-Level Truth: A Supervision Auditing Framework for Chest Radiograph AI

eess.IV cs.CV ·2026-08-10 ·Yesika Alexandra Agudelo-Londoño, Jhon Wilmer Pino-Román, Brahian Carrera Rodríguez, José Miguel Castañeda-Bedoya, Juan Pablo Gómez-López +7 more
published similarity 0.60
Abstract · Accepted (oral) at the 3rd MICCAI Student Board (MSB) EMERGE Workshop, MICCAI 2026. This is the authors' version; the final authenticated ve…

Public chest X-ray repositories are widely used to train medical AI systems, yet their labels are typically extracted from radiology reports rather than verified directly on images. As a result, repository labels are often treated as image-level ground truth without validating whether they reflect what is actually visible in the radiograph. We introduce Repository Supervision Auditing (RSA), a framework that evaluates repository-derived labels against expert image-level annotations before model development. Using cardiomegaly in MIMIC-CXR as a case study, RSA compares repository labels with radiologist-reviewed image annotations, characterizes disagreement sources, and builds a curated cohort for deployment-oriented evaluation. Repository-derived cardiomegaly labels showed near-zero agreement with expert image-level assessment, identifying only 1% of expert-confirmed cases. Most discrepancies resulted from non-mention rather than explicit report negation, with expert-confirmed cardiomegaly identified in nearly half of studies assigned a repository-derived No Finding label. Using the resulting expert-curated cohort, a DenseNet121 model achieved a test ROC-AUC of 0.853. These findings show that repository labels may not reliably represent image-level truth and highlight supervision auditing as a critical step for developing trustworthy medical imaging AI.

0.24

Unmentioned Checklist Findings Change How Reinforcement Learning Appears to Improve Chest Radiograph Report Checking

cs.CV cs.CLcs.LG ·2026-10-04 ·Ali Vosoughi, Akhil Kasturi, Chenliang Xu, Axel Wismueller
code/data similarity 0.57
Abstract · 40 pages, 7 figures, 17 tables (main text and references pp. 1-19; Supplementary Information as an appendix, pp. 20-40). Submitted to npj Di…

Automated checks of radiology reports may rely on AI-generated checklists that leave findings unmentioned. We used reinforcement learning to train a vision-language model to fill in a 12-finding checklist from a chest radiograph without seeing the sentence under test; a separate checking model judged the sentence from the checklist. On held-out patients, a rule-based check and an independent medical checker, neither used in training, measured discrimination gains (Youden index) of 12.6% and 11.8%; only the rule-based check met the prespecified false-alarm criterion. Switching to the training format, which fixes finding order and enters unmentioned findings as absent, raised the training checker's measured gain and lowered the independent checker's, a prespecified comparison that yielded 6.2% (95% interval 2.0% to 10.5%) and, post hoc on held-out patients, 7.7%. Across 8 checking models, acceptance of a label-consistent negative statement about an unmentioned finding ranged from 1.0% to 97.0%. Labels were report-derived, not radiologist-adjudicated.

0.54

MIRROR: Multimodal Intelligent Radiology Reasoning and Observation Reporter

cs.CV cs.AIcs.LG ·2026-08-17 ·Vignesh Nagarajan, Sriram Venkatapathy
hot direction similarity 0.57
Abstract · 8 pages, 5 figures, 5 tables, 24 references

A radiologist reading a model's output faces two problems. The model returns a number and no reason, and any system that turns that number into readable prose can quietly add claims the model never made. MIRROR is a research prototype built to separate those failures. It chains a multi-label classifier, a Grad-CAM localizer that turns each positive finding into a named anatomical region, and a report writer that receives the labels, probabilities, and regions but never the image. Because the language layer cannot see pixels, it cannot assert a finding the classifier did not make. We are precise about what that buys: a MIRROR report's findings are auditable against the probability vector, while the sentences framing them are ordinary generated text, and we show one stating a cardiothoracic ratio the system never measured. One registry holds the taxonomy, anatomy, and phrasing for chest X-ray, brain MRI, and head CT, so adding a modality is a data change; all three are routed and tested, one is trained. On ChestMNIST that classifier reaches macro AUROC 0.729 and ranks better than chance on all 14 labels, at 1.6 to 6.8 times the precision a random ranker would get. Yet at the default 0.5 threshold it emits no positive prediction at all for 11 of them, and its excellent-looking Brier score of 0.045 sits beside the 0.047 earned by a predictor that ignores the image. The discrimination is real; the decisions are not. Under the class imbalance normal in radiology, aggregate metrics flatter models that do nothing, and should be reported against that floor.

0.32

A Concept-informed Interpretable Artificial Intelligence Framework for Breast Ultrasound Diagnosis

cs.CV ·2026-10-12 ·Shengzhou Zhong, Ziying Wang, Liang Li, Lihua Yan, Shuochun Chen +12 more
code/data similarity 0.57
Abstract · 31 pages, 17 figures, 4 tables

Most existing artificial intelligence systems for breast ultrasound rely primarily on image-driven prediction, with limited incorporation of the knowledge from the Breast Imaging Reporting and Data System (BI-RADS) and the intermediate assessment processes underlying radiologists' workflow, thereby constraining their interpretability and alignment with clinical practice. We curated, to our knowledge, the largest multicenter collection of breast ultrasound images paired with structured BI-RADS descriptors, comprising 9,941 patients across 20 independent datasets. Across 14 testing datasets, IBUS demonstrated consistent generalization performance across different clinical centers and imaging conditions. Incorporating BI-RADS descriptors enabled fine-grained risk stratification, while cross-checking predicted BI-RADS grades against malignancy probabilities identified internally discordant predictions that may warrant additional clinical review. In a reader study involving eight radiologists, IBUS assistance increased diagnostic sensitivity among both junior and senior readers, with the potential of guiding radiologists to make targeted revision in risk stratification. Overall, IBUS exhibits its potential as a second-stage decision-support system that complements radiologists by providing additional risk estimates and interpretable evidence for diagnostically challenging cases. The demo video of IBUS platform is publicly available at https://github.com/zsz1997/IBUS.

0.30

Clinical value claims in multimodal AI outpace supporting evidence

cs.LG cs.CY ·2026-10-09 ·Jiayu Feng
survey similarity 0.56
Abstract

Multimodal prediction models add a data source, such as imaging or an assay, to clinical information, and health systems must decide whether that added test is worth acquiring. We audited 177 studies comparing multimodal with unimodal models: 81 from a systematic review and 96 from a probability sample of 2025-2026 PubMed records. Gains in the area under the receiver operating characteristic curve (AUROC) were smaller when a study fitted a separate model for every data source (adjusted difference, -0.030; 95% CI, -0.056 to -0.005). Within 78 such studies, leaving out the strongest source's model would have raised the average gain from 0.046 to 0.108. This complete benchmarking fell from 69.1% of review studies to an estimated 46.0% of recent ones. An estimated 22% assessed decision utility and none evaluated a model prospectively, yet most claimed potential clinical usefulness or improved care (84.0% and an estimated 87.7%).

0.21