CS Paper Radar

Multi-Tier Edge Triage: Optimizing Latency for Safe Clinical Agents

Joshua Broyde, Sarita A. Joshi

cs.LG ·submitted 2026-11-20 00:00 UTC · v1
benchmark

Abstract

Deploying generative AI agents in enterprise clinical workflows requires enforcing multi-dimensional safety and compliance policies--preventing HIPAA Protected Health Information (PHI) exposure, maintaining clinical scope-of-practice boundaries, ensuring patient-appropriate reading comprehension, and preserving brand integrity--under interactive latency constraints. Synchronous outbound calls to cloud Large Language Model (LLM) judges add substantial network and decoding overhead onto the critical response path. We present Multi-Tier Edge Triage, a safety screening architecture that co-locates a compact Tier-1 sequence classifier on the clinical agent's host server, resolving clear queries in-process without a network round-trip and escalating only ambiguous queries to a Tier-2 cloud LLM judge. To evaluate Tier-1 encoders without length or unigram shortcuts, we construct four length-matched contrastive twin benchmarks seeded from MedSafetyBench, ASQ-PHI, and a synthetic four-mandate clinical assistant policy (Generic HealthCorp). While frozen local encoders match cloud models on structured PHI detection (>= 98.3% accuracy in <= 23.5 ms), they degrade markedly on semantic safety and symmetric-blocklist prompts. However, end-to-end representation fine-tuning closes the multi-policy accuracy gap: a fine-tuned 335M-parameter BGE-Large classifier achieves 98.90% out-of-fold accuracy versus 99.20% for a zero-shot cloud LLM judge (exact McNemar p = 0.648, zero shared errors), 97.8%-98.2% recall, and a 0.0%-0.4% over-refusal rate in 39.0 ms (>14x faster than cloud LLM evaluation on our benchmark host). Per-policy error analysis reveals ceiling local recall on PHI (100.0%), brand (100.0%), and clinical scope (98.7%-99.3%) violations, isolating residual errors to reading-level checks (93.3%-95.3%) and motivating targeted multi-tier escalation.

Comment
16 pages, 7 figures, 8 tables

Closest papers

Nearest neighbours by meaning across the whole index.

A Cloud-Edge System for Multimodal Clinical Screening in Resource-Constrained Rural Settings

cs.LG cs.DC ·2026-08-13 ·Hei Ting Chan, Chenwei Wu, Xueshen Liu, Zesen Zhao, Boyuan Zheng +5 more
top venue similarity 0.67
Abstract · 31 pages, 3 figures. In Proceedings of Machine Learning Research, Volume 340, 2026 (Machine Learning for Healthcare Conference)

Medical AI has demonstrated specialist-level diagnostic accuracy, yet these capabilities remain largely inaccessible in resource-constrained rural settings where bandwidth is scarce, compute is limited, and clinical decision-making requires integrating heterogeneous modalities. We introduce a cloud--edge collaborative architecture that addresses these constraints: lightweight, domain-specific models on the edge transform raw medical data into compact structured outputs, while a cloud LLM synthesizes these outputs into clinical summaries. An LLM-based orchestrator dynamically selects diagnostic tools based on patient context, promoting comprehensive modality coverage without processing irrelevant inputs. We evaluate on 20 multimodal clinical cases spanning cardiac, obstetric, trauma, and screening scenarios under three simulated network profiles (500,kbps--5,Mbps). The hybrid system achieves 98--99% diagnostic tool recall with 92--96% precision, matches or exceeds cloud-only baselines on clinical accuracy, and maintains bandwidth-invariant latency (25--35,s) at 4--15x lower token cost. These results highlight the role of architectural design in enabling efficient multimodal integration and improving factual grounding compared to cloud-only approaches under deployment constraints.

0.40

TwinGuard-Lite: A Rule-Based State-Admission Gateway for Generative Patient Digital Twins

cs.CR ·2026-10-06 ·Wenhui Chu, Sheikh Rabiul Islam
published similarity 0.66
Abstract · 6 pages, 2 figures, 1 table. Accepted to HealthSec'26 (Cybersecurity in Healthcare), co-located with ACSAC 2026

Future generative patient digital twins may combine longitudinal health records with language-model agents and keep information across sessions. The wording of a proposed update does not reveal whether it comes from an allowed source, conflicts with the patient's record, or belongs to someone else. We present TwinGuard-Lite, a rule-based gateway that admits an update to a twin's persistent state only if it passes checkable approximations of two integrity properties. Grounded state consistency (GSC) is approximated by a provenance check and a contradiction check; cross-patient noninterference (CPN) is approximated by a namespace check against trusted transport metadata. We evaluate three attack families over 20 seeded person-level splits of a semi-synthetic stream built from the openly licensed eICU database demo, with 29,131 $\pm$ 2706 candidate updates per seed. A keyword filter and an anomaly detector detect 16% and 24% of attacks, respectively; a provenance-only ablation detects 59.9% but misses every cross-patient attack. Combining GSC and CPN yields 99.1% precision, 90.5% recall, a 94.6% F1 score, and a 0.033% false-positive rate. Every attack the full gateway admits falsely claims a trusted source; when the retrieval channel does so, 92.9% of retrieval attacks are admitted. The results hold under stated trust assumptions, and no language model, agent, or retriever is executed: TwinGuard-Lite is a mechanism-level proof of concept that motivates authenticated, patient-bound ingestion, not a clinical safeguard.

0.41

EHR-RobustGym: Benchmarking and Training Agents for Robust Clinical Reasoning

cs.AI cs.LG ·2026-09-30 ·Yitong Qiao, Yancheng Jin, Lei Liu, Yue Shen, Jian Wang +2 more
similarity 0.66
Abstract

In hospital workflows, electronic health records (EHRs) are often noisy, and may not contain the evidence needed to confirm events or measurements referenced in a clinical query. Even when database retrieval succeeds, clinical agents can overlook such discrepancies and return plausible but unsupported answers. We introduce EHR-RobustGym, a scalable and interactive environment for evaluating and training robust clinical agents grounded in noisy EHRs. Built on MIMIC-IV hospital records (365K patients, 31 tables, and over 500M records), EHR-RobustGym comprises 5,486 Clean-Noise pairs spanning six clinical intents and both patient-level and population-level queries. The pairs test robustness to Record-level, Value-level, and Query-level noise, while interactive SQL/Python execution and outcome verification support trajectory collection and training. Evaluating multiple LLMs reveals substantial robustness gaps: average task success across proprietary and large-scale open-weight models drops from 62.2% on Clean questions to 37.9% on Noise questions. At k=4, pass^k consistency falls below 50% for most evaluated models, exposing instability in clinical task completion. Supervised fine-tuning and reinforcement learning in EHR-RobustGym improve performance, with gains generalizing to five external EHR benchmarks. Together, these results position EHR-RobustGym as a testbed for evaluating and improving the evidence-grounded robustness of clinical agents.

0.07

Large Language Models for Structured Clinical Data Analysis: Dual-Agent Grounding and Validation

cs.AI ·2026-09-28 ·Erfan D. Dehkalani, Seetha Shankaran, Abbot R. Laptook, C. Michael Cotten, P. Ellen Grant +1 more
benchmark similarity 0.65
Abstract · 22 pages, 2 figures

Objective: To develop and characterize CLEAR-Med, a dual-agent framework for natural-language analysis of structured clinical data that separates SQL-based invocation from independent validation. Methods: CLEAR-Med uses one agent to translate a question into executable Structured Query Language (SQL), retain the executed query and database result, and produce a draft. Deterministic checks and a separately invoked cross-provider Validation Agent then accept the draft, request one bounded repair, or abstain. We formalized the system as a bounded selective pipeline and evaluated CLEAR-Med's configuration and scalability, and the Invocation Agent's accuracy and consistency on a 25-query development benchmark, using a harmonized 21-site neonatal hypoxic-ischemic encephalopathy table containing 532 de-identified infant records and approximately 1,300 variables. Results: CLEAR-Med completed all six nominal scalability configurations, including 500x1300. Across 25 development-benchmark queries repeated five times, the Invocation Agent answered 83 of 125 responses correctly (66.4%; query-cluster bootstrap 95% CI, 48.0-83.2%), compared with 15 of 125 (12.0%; 95% CI, 3.2-22.4%) for the ungrounded ChatGPT baseline, a paired improvement of 54.4 percentage points (95% CI, 36.8-72.0%). Conclusion: CLEAR-Med provides a general architecture for traceable analysis of structured clinical data: numerical claims remain linked to executed SQL, and unresolved cases can fail closed. The reported experiments characterize CLEAR-Med's configuration and scalability and the Invocation Agent's accuracy, while the formal analysis establishes the encoded-property guarantee of the complete control flow; a prospective full-pipeline evaluation of the validation and abstention stages is the next stage of this work.

0.17

A Living Benchmark for Information Retrieval from Electronic Health Records

cs.AI ·2026-09-24 ·Jordan L. Cahoon, Chloe O. Stanwyck, Sulaiman Somani, Philip Chung, Kevin R Keet +21 more
benchmark similarity 0.65
Abstract

Large language model (LLM)-based clinical assistants are increasingly being integrated into electronic health record (EHR) systems, transforming how clinicians retrieve and synthesize information from patient records. Their safety and utility depend on rigorous evaluation, yet existing benchmarks are manually curated, costly to update, and rapidly become obsolete with evolving technological advancements. We present a scalable framework that automatically generates question--answer pairs from longitudinal EHR notes. Nineteen clinicians validate the benchmark generator, producing the Benchmark for Retrieving Information in EHRs (BRIE), a continuously maintainable evaluation dataset. Across nine LLMs and five inference strategies, state-of-the-art systems frequently omit clinically important information, particularly for questions requiring synthesis across multiple documents and encounters. Because the generator itself is validated, BRIE supports evaluations that static benchmarks cannot, including the generation of multiple answers that reflect variation in clinician reasoning for robust performance assessment and continuously refreshing benchmark content to guard against leakage. Our results demonstrate that scalable benchmark generation enables rigorous, up-to-date evaluation of clinical LLMs as they are deployed in rapidly evolving healthcare settings.

0.30

A general-purpose System One decision model for clinical records

cs.AI ·2026-10-19 ·Andrew Zhang, Trinh T. L. Vuong, Sophia J. Wagner, Dongmin Bang, Tong Ding +12 more
similarity 0.63
Abstract

Clinical care, health-system operations and biomedical discovery depend on extracting reliable answers from patient records, yet applying diverse clinical questions across entire populations remains computationally expensive. Here we present Clinical System One (CS1), a 4-billion-parameter decision model for fast, typed judgments from clinical records, along with two agentic harnesses in which CS1 works together with a generalist language model. CS1-4B is trained on 12.4 million questions and answers from 3.6 million patients across a multi-hospital health system, combining structured-data keys, observed outcomes and language-model supervision across clinical notes, diagnostic reports and patient timelines. It answers multiple typed questions in a single forward pass without task-specific retraining, and each answer carries a probability that can route uncertain cases to human review. On 963,408 held-out patients, CS1-4B outperformed open decision models up to 27 billion parameters on 13 of 14 tasks scored independently of its training teacher. Across 21 external data sets, its aggregate performance approached that of the strongest tested 27-billion-parameter model, with 6.4-fold faster inference in a matched workload. Integrating CS1-4B with a language model agent produced cited answers over complete multi-year patient histories and screened a patient population against the eligibility criteria of 17 registered clinical trials, placing four times as many judged-eligible patients among its top 20 candidates as keyword search while using 690-fold fewer language-model tokens than a language model reading every record. These findings support a division of labour in clinical AI, with small decision models performing repeated record reading and generative models formulating questions and synthesizing evidence.

0.42

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

cs.LG ·2026-08-13 ·Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala +1 more
benchmark similarity 0.63
Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

0.04

MedPsy: State-of-the-Art Small Medical Language Models for Efficient Edge Deployment

cs.CL ·2026-11-01 ·Davide Vitabile, Alexandro Buffa, Akshay Nambiar, Amril Nazir
top venuecode/data similarity 0.63
Abstract · Accepted at NeurIPS 2026 (main conference)

Medical language models promise expert clinical support, but the strongest open-source LLMs remain too large for private edge-device deployment, while compact medical models still trail substantially on knowledge-intensive and real-world healthcare tasks. Reasoning models that fit edge memory budgets can produce long reasoning traces, increasing sequential decoding, end-to-end latency, energy consumption, and KV-cache memory pressure. We present MedPsy, a family of text-only 1.7B and 4B medical language models designed for edge deployment, targeting this accuracy-generation-efficiency trade-off. Our recipe combines a synthetic medical data pipeline over biology, medicine, and health seeds with chain-of-thought targets from a 235B medical-focused LLM teacher; a four-stage post-training curriculum comprising two SFT stages followed by two RL stages with hard-sample mining; and an edge deployment evaluation spanning multiple GGUF quantization variants and real-device inference on laptop and smartphone hardware. On seven closed-ended medical benchmarks, MedPsy-4B surpasses MedGemma-1.5-4B by 19.34 points and matches MedGemma-27B while being 6.75x smaller; MedPsy-1.7B outperforms MedGemma-1.5-4B by 11.42 points despite being less than half its size. On HealthBench-Hard, MedPsy-4B surpasses MedGemma-27B by 15.33 points, while MedPsy-1.7B surpasses it by 11.66 points despite being ~16x smaller. Beyond accuracy, MedPsy reduces average response length by 1.7x (1.7B) and 3.2x (4B) versus its Qwen3 backbones, while Q4_K_M quantization preserves the aggregate score within 1 point of BF16 with ~69% lower disk footprint. In real-device inference, MedPsy-4B's shorter generations translate into 75% lower median end-to-end latency and estimated energy per answer than its Qwen3 backbone at matched quantization, while peak RAM remains below 5 GB across our tested laptop and smartphone configurations.

0.51