CS Paper Radar

Large Reported CHB-MIT Adaptation Gains Disappear with Pretrained Encoders and Matched Probes

Joseph Sankoorikal Johny, Antony J. Sankoorikal

cs.LG stat.ML ·submitted 2026-11-20 00:25 UTC · v1
code/data

Abstract

Dani and Liebe (2026) (DL) report that adapting the final encoder block of BIOT and CBraMod with self-supervised learning (SSL) improves CHB-MIT seizure-detection ROC-AUC by 36.2 and 29.5 points over linear probing. We investigate these results with their released code and an independent pipeline. The release loads pretrained weights for adaptation only when an otherwise unset configuration key is supplied, and its CBraMod probe reads the reconstruction head with dropout active. With pretrained initialisation and a probe on the encoder output in evaluation mode, the fixed-recipe adaptation gain on DL's split is -0.6 points for BIOT (95% interval [-3.8, +2.6]) and +0.01 for CBraMod ([-0.02, +0.04]) across five seeds. Across DL's split and five subject rotations on CHB-MIT and Siena Scalp EEG, with equally tuned linear probes (30 configurations, up to 500 epochs, validation-based early stopping), mean adaptation effects range from -1.1 to +5.7 ROC-AUC points over 18 comparisons (related settings and feature variants). Twelve of 18 support equivalence within +/-3 points under dependence-adjusted inference (8 of 12 rotation and 4 of 6 fixed-split comparisons); six are unresolved. After correcting rotation intervals for dependence, no positive effect has a 95% interval excluding zero. The +/-3 margin is an analysis threshold, not a clinically validated one, and smaller margins support fewer equivalences. Two fixed-probe gains near +21 points shrink under the same tuning, with smaller benefits unresolved. We also audit a CHB-MIT protocol shared by at least 14 papers. No tested configuration reproduces DL Table 1 as a whole. These findings concern the tested configurations; the encoder-level probe and subsequent checks were chosen post hoc.

Comment
47 pages, 8 Figures. Code and analysis outputs: https://github.com/johnyj02/eeg-drift

Closest papers

Nearest neighbours by meaning across the whole index.

Parameter-Efficient Self-Supervised Adaptation for EEG-FM under Fixed Computational Budgets

cs.LG cs.AI ·2026-08-25 ·Meghal Dani, Stefanie Liebe
top venuecode/data similarity 0.73
Abstract

EEG foundation models pretrained via self-supervised learning promise transferable representations, but their generalization remains limited, especially across diverse clinical datasets. Full fine-tuning is impractical for resource-constrained clinical settings due to high computational requirements. In this work, we investigate whether parameter-efficient self-supervised adaptation, updating only 9% of parameters suffices to align representations to target tasks. We evaluate our method on two state-of-the-art models with different pretraining objectives: BIOT (contrastive) and CBraMod (masked reconstruction), and evaluate on three clinical EEG datasets for abnormality detection (TUAB), event classification (TUEV), and seizure detection (CHB-MIT) under both in-distribution and out-of-distribution conditions. SSL adaptation yields consistent gains over linear probing, up to 20x AUCPR. Under a fixed compute budget, peak performance requires only 20--50% of available unlabeled data. Critically, when total window count is fixed, performance remains invariant to patient count, suggesting that performance is dependent on overall temporal window diversity only. Our findings demonstrate that parameter-efficient adaptation enables effective deployment of EEG Foundation models (EEG-FM) with minimal computational overhead and data collection burden. Code available at: https://github.com/c3n-group/efficient-eeg-adapt

0.54

Lightweight Semantic EEG Foundation Model for Frozen Cross-Disorder Transfer

cs.LG eess.SPq-bio.NC ·2026-10-04 ·Rita Huan-Ting Peng, Nhat Bui
similarity 0.62
Abstract

Large-scale EEG foundation models have demonstrated promising transferability across neurological disorders, but often require millions of parameters and substantial computational resources. In this paper, we present the Universal Semantic EEG Foundation Model (USE-FM), a lightweight EEG foundation model that learns transferable neural representations through self-supervised signal reconstruction on the Temple University Hospital EEG Corpus (TUEG). After pretraining, the encoder is frozen and evaluated on two clinically distinct downstream tasks, abnormal EEG detection (TUAB) and epileptic seizure recognition (TUEP), using a unified frozen-transfer protocol against recent EEG foundation models, including LUNA-Base and CBraMod. With only 1.46 million parameters, approximately one-fifth the size of existing models, USE-FM achieves competitive overall performance, including strong sensitivity and F1-score on TUEP (SEN $75.00 \pm 14.14$, F1 $70.37 \pm 4.01$), while maintaining competitive performance on TUAB (AUC $85.24 \pm 5.61$). Beyond downstream classification, latent representation analysis using $k$-means clustering together with PCA and t-SNE demonstrates that USE-FM learns organized semantic EEG representations comparable to substantially larger foundation models. These results suggest that large-scale self-supervised pretraining enables lightweight architectures to learn transferable semantic EEG representations, providing a computationally efficient foundation for cross-disorder analysis and future clinical decision support in neurological disorders.

0.06

Hybrid Ensemble Learning for EEG-Based Epileptic Seizure Forecasting

cs.LG ·2026-09-26 ·Mason Dana, Khandaker Mamun Ahmed
publishedcode/data similarity 0.61
Abstract · Accepted at the 2026 IEEE Cyber Awareness Research Symposium (CARS 2026)

Epileptic seizure forecasting aims to provide actionable warnings before seizure onset, yet patient-independent generalization and false-alarm control remain major challenges. We propose a calibrated hybrid ensemble for EEG-based seizure forecasting that combines five deep learning models and three classical machine learning models through a logistic regression stacking meta-learner. The proposed pipeline integrates signal preprocessing, handcrafted feature extraction, class-imbalance handling, probability calibration, and clinically motivated post-processing. We evaluate the framework on CHB-MIT using strict Leave-One-Patient-Out (LOPO) cross-validation, with threshold and post-processing parameters selected only on held-out meta data. On the filtered cohort, excluding patients with anomalous preictal rates below 1\% or above 15\%, the model achieves 74.2\% seizure-level sensitivity at 1.24 false alarms per hour, with an average warning time of 16.9 minutes. A test-tuned oracle constrained to the target false-alarm budget achieves 60.9\% sensitivity at 0.951 false alarms per hour, highlighting the importance of reporting sensitivity together with realized false-alarm rates. Our code is available at: https://github.com/DanaMason/IEEE-CARS-Hybrid-Ensemble-Learning-for-EEG-Based-Epileptic-Seizure-Forecasting

0.36

LaBraM at Scale: Scaling Data and Models for EEG Pretraining

cs.LG cs.AI ·2026-11-02 ·Jun-Yu Pan, Ruicheng Yin, Bao-Liang Lu, Dongsheng Li, Wei-Long Zheng +1 more
similarity 0.60
Abstract

LaBraM, an early EEG foundation model, demonstrated that large-scale EEG pretraining can yield strong representations for diverse downstream tasks. Building on this foundation, we expand pretraining data and model capacity while retaining its core encoder and objective. We train ten encoders with 5.8 million to 1.97 billion parameters on three EEG collections spanning 25,067 to 79,910 hours, adapting signal preparation and training to heterogeneous recordings. Across 23 tasks, Atom-L* reaches 59.05% mean balanced accuracy at its best evaluated full fine-tuning (Full-FT) checkpoint, 3.61 percentage points above the strongest baseline EEG foundation model. Quark-G leads linear probing (LP) at 54.33%, a 1.24-point margin. Both also lead average task rank. At the last evaluated checkpoints, larger encoders improve Full-FT more consistently than LP, and stronger LP does not guarantee stronger Full-FT. Preserving patch structure improves LP over average pooling. Data-fraction experiments suggest capacity-dependent saturation, while checkpoint trajectories show that downstream performance can decline as pretraining loss falls. Joint classification with a shared Qwen3 readout reaches 50.50% with Molecule-H and Qwen3-8B; increasing language-model size provides no consistent gain. These results demonstrate the value of scaling LaBraM and the importance of matching pretraining scale to downstream adaptation.

0.37

Controlled Evaluation of EEG Foundation Models: Random Initialisation, Band-Power and Validation-Selected Probes

cs.LG cs.AI ·2026-10-23 ·Mingyu Jeon, Suwan Cho, Jae Young Suh
similarity 0.58
Abstract

EEG foundation models report downstream gains, yet their protocols seldom include three controls. These are the same encoder untrained, spectral features fitted on the same data, and a layer picked without looking at test scores. We therefore evaluate five publicly released EEG foundation models and an in-house JEPA-style model under one protocol with all three controls and several seeds, on five benchmarks and four added task families. The controls change the reading in three ways. First, picking the probed layer by its test score raises the layer-wise peak by an average of +0.034 and reverses the peak-versus-output gap in 9 of 36 cells. Second, with the layer picked on validation, random initialisation matches or beats pretraining for half of the models on sleep and emotion, and no model beats a five-band log-power baseline on emotion or motor imagery. Third, after full fine-tuning only 5 of 30 pairs gain beyond twice their seed spread, and the one clear loss of -0.290 AUROC persists under matched learning rates. From these results we draw four reporting practices, and we release every cell for re-analysis.

0.06

What Balanced Accuracy Cannot Identify in Neural-Signal Decoding under Test-Time Adaptation

cs.AI ·2026-11-13 ·Jiangshuo Xie, Zonghan Wu
similarity 0.58
Abstract

Adaptation for neural-signal classification is usually transductive: each batch is scored after updating on it, and the gain depends on the adapted model [4]. This paper asks what an aggregate change fails to characterise inside the cohort. Full test-time adaptation (full_ttt) was evaluated in 11 dataset-encoder cells (four each on Siena/EEG and PTB-XL/ECG, three on Sleep-EDF/EEG), with splits and source-model evaluation fixed; the subject was the unit, exact sign tests were Holm-corrected and conditional on the shared stream, and bootstrap intervals accompanied a dependence audit. Two results of different kinds follow. In the binary case balanced accuracy gives a one-class decoder the same value as one reporting both classes at 50%, so the aggregate cannot identify a class that stopped being reported; a class covering a tenth of a subject's samples went unpredicted in 26-47 of 112 subject-cells, against 7-9 for the controls, which is a descriptive count. With cohort, split and update rule fixed, the within-subject class contrast follows the encoder, tested directly rather than inferred from tests against zero: two of six Siena encoder pairs survive the dependence readings at their nominal reference and one at a fold-level reference, while two of ten Sleep-EDF stage pairs pass the run-clustered gate at its nominal reference; aggregate and contrast named different encoders in 10 of 11. The protocol bounds both results, since a stream-interleaving effect reverses sign with state sharing (+3.5 to -2.4 pp). An aggregate score can hide individual harm, as [1] showed, but it cannot distinguish a uniform loss from a deleted class; class-level change should therefore be reported alongside the aggregate and subject-level change alongside it, with both results conditional on the cell, the rule and the stream construction.

0.23

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

cs.CE cs.LG ·2026-08-31 ·Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
benchmark similarity 0.57
Abstract

Motor imagery (MI) electroencephalography (EEG) decoding could support post-stroke rehabilitation, but models developed on healthy cohorts may not transfer reliably to pathological EEG. We evaluated whether Low-Rank Adaptation (LoRA) can efficiently adapt three pretrained EEG foundation models (i.e., LaBraM-base, REVE-base, and REVE-large) for binary left- versus right-hand MI decoding. Frozen-backbone head-only baselines and LoRA adaptation were evaluated using subject-wise five-fold cross-validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 dataset comprising 30 stroke participants. On EEGMMIDB, LoRA increased accuracy to 0.822 for LaBraM-base and 0.957 for REVE-base. On UET175, all head-only models performed near chance. With LoRA, LaBraM-base remained near chance (0.499$\pm$0.009), whereas REVE-base reached 0.847$\pm$0.194 and outperformed REVE-large (0.806$\pm$0.178), indicating that increased model capacity alone did not improve stroke-domain adaptation. The strongest stroke configuration, REVE-base LoRA, was further evaluated using within-cohort leave-one-subject-out cross-validation (LOOCV), showing 0.952 mean accuracy, but subject-wise accuracy ranged from 0.586 to 1.000, revealing a small low-performing tail. Zero-shot transfer from EEGMMIDB to UET175 remained near chance (0.464$\pm$0.072). These findings show that healthy-benchmark performance does not ensure transfer to stroke EEG. Translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiological discriminability.

0.28

TransECG-SSL: Hybrid Self-Supervised Representation Learning for ECG Arrhythmia Classification

cs.LG ·2026-10-26 ·Ahtisham Ayyub, Fasih Haider, Muhammad Rehan Usman, Saturnino Luz, Christos Politis +1 more
similarity 0.57
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics

Cross-dataset generalisation remains a major challenge for automated electrocardiogram (ECG) arrhythmia classification because of differences in patient populations, acquisition protocols, annotation practices, and class distributions. Learning representations that remain informative across independent datasets could reduce reliance on dataset-specific labelled data. We propose TransECG-SSL, a self-supervised framework for transferable heartbeat representation learning from unlabelled ECG data. A Transformer encoder is pretrained using a hybrid objective combining masked signal reconstruction and contrastive learning, then frozen and evaluated by linear probing under patient-disjoint evaluation. Experiments across three public ECG databases and seven source--target settings show that Hybrid SSL consistently outperforms randomly initialised Transformers and achieves higher balanced accuracy than architecture-matched source-supervised pretraining. Reconstruction-only SSL remains competitive with Hybrid SSL, whereas contrastive-only pretraining performs substantially worse, highlighting the importance of masked reconstruction for transferability. Cross-dataset transfer nevertheless reduces balanced accuracy relative to target-specific self-supervised pretraining, while minority arrhythmia classes remain challenging under severe class imbalance. These findings demonstrate the potential of label-efficient self-supervised learning for cross-dataset ECG representation transfer while highlighting persistent limitations from domain shift and class imbalance.

0.24