CS Paper Radar

What Balanced Accuracy Cannot Identify in Neural-Signal Decoding under Test-Time Adaptation

Jiangshuo Xie, Zonghan Wu

cs.AI ·submitted 2026-11-13 09:04 UTC · v1

Abstract

Adaptation for neural-signal classification is usually transductive: each batch is scored after updating on it, and the gain depends on the adapted model [4]. This paper asks what an aggregate change fails to characterise inside the cohort. Full test-time adaptation (full_ttt) was evaluated in 11 dataset-encoder cells (four each on Siena/EEG and PTB-XL/ECG, three on Sleep-EDF/EEG), with splits and source-model evaluation fixed; the subject was the unit, exact sign tests were Holm-corrected and conditional on the shared stream, and bootstrap intervals accompanied a dependence audit. Two results of different kinds follow. In the binary case balanced accuracy gives a one-class decoder the same value as one reporting both classes at 50%, so the aggregate cannot identify a class that stopped being reported; a class covering a tenth of a subject's samples went unpredicted in 26-47 of 112 subject-cells, against 7-9 for the controls, which is a descriptive count. With cohort, split and update rule fixed, the within-subject class contrast follows the encoder, tested directly rather than inferred from tests against zero: two of six Siena encoder pairs survive the dependence readings at their nominal reference and one at a fold-level reference, while two of ten Sleep-EDF stage pairs pass the run-clustered gate at its nominal reference; aggregate and contrast named different encoders in 10 of 11. The protocol bounds both results, since a stream-interleaving effect reverses sign with state sharing (+3.5 to -2.4 pp). An aggregate score can hide individual harm, as [1] showed, but it cannot distinguish a uniform loss from a deleted class; class-level change should therefore be reported alongside the aggregate and subject-level change alongside it, with both results conditional on the cell, the rule and the stream construction.

Closest papers

Nearest neighbours by meaning across the whole index.

Benchmarking Label-Revealed Online Updates for EEG BCI Decoding

cs.LG eess.SP ·2026-10-05 ·Bogdan Kozyrskiy, Artem Grachev, Abraham I. Camelo Guerrero
benchmark similarity 0.58
Abstract

Electroencephalography (EEG) signals drift over time, which can cause static brain-computer interface (BCI) models to degrade in practice. We present a benchmark for online adaptation and compare two widely used pipeline families, Common Spatial Patterns (CSP) and Riemannian covariance-based methods, under time-ordered prequential (test-then-train) evaluation. We examine (i) which pipelines benefit most from label-revealed updates, (ii) whether controlled forgetting of older data improves robustness, and (iii) how a minimal-calibration cold start compares with starting from a pretrained model. Across four datasets (three motor-imagery datasets and one movement-decoding dataset), label-revealed online updates improve 13 of 14 model/dataset pairs on the two largest streams, with relative accuracy gains of up to about 18% over a frozen model. A Shapley-based data-valuation analysis over temporal blocks assigns the largest mean value to the most recent block in each of the three analyzed datasets, while older blocks retain positive value.

0.42

How Much of Cross-Subject EEG Emotion Recognition Is Stimulus Memorization?

eess.SP ·2026-10-20 ·Haiyan Xu, Konstantinos N. Plataniotis
similarity 0.58
Abstract · 5 pages, 1 figure, 2 tables

Cross-subject EEG emotion recognition now reports accuracies above 90% on stimulus-defined benchmarks such as SEED, and the field has examined several ways in which such numbers can be inflated, attributing inflation to subject identity, to data partitioning, and to repeated stimulus presentation. We observe that one variable has been left out. On these datasets the emotion label is assigned to the video at design time, so any encoder that recovers which video was shown obtains the label for free. We adapt three representation-level shortcut diagnostics to a cohort of published contrastive cross-subject encoders, and find that stimulus identity is linearly recoverable at six to fifteen times chance. We then measure its impact on the reported accuracy by holding out subjects and stimuli jointly, and find that each released classifier loses two to forty-four points once the test videos are unseen, so a headline obtained under subject hold-out alone is not a measure of cross-subject emotion decoding.

0.16

Large Reported CHB-MIT Adaptation Gains Disappear with Pretrained Encoders and Matched Probes

cs.LG stat.ML ·2026-11-20 ·Joseph Sankoorikal Johny, Antony J. Sankoorikal
code/data similarity 0.58
Abstract · 47 pages, 8 Figures. Code and analysis outputs: https://github.com/johnyj02/eeg-drift

Dani and Liebe (2026) (DL) report that adapting the final encoder block of BIOT and CBraMod with self-supervised learning (SSL) improves CHB-MIT seizure-detection ROC-AUC by 36.2 and 29.5 points over linear probing. We investigate these results with their released code and an independent pipeline. The release loads pretrained weights for adaptation only when an otherwise unset configuration key is supplied, and its CBraMod probe reads the reconstruction head with dropout active. With pretrained initialisation and a probe on the encoder output in evaluation mode, the fixed-recipe adaptation gain on DL's split is -0.6 points for BIOT (95% interval [-3.8, +2.6]) and +0.01 for CBraMod ([-0.02, +0.04]) across five seeds. Across DL's split and five subject rotations on CHB-MIT and Siena Scalp EEG, with equally tuned linear probes (30 configurations, up to 500 epochs, validation-based early stopping), mean adaptation effects range from -1.1 to +5.7 ROC-AUC points over 18 comparisons (related settings and feature variants). Twelve of 18 support equivalence within +/-3 points under dependence-adjusted inference (8 of 12 rotation and 4 of 6 fixed-split comparisons); six are unresolved. After correcting rotation intervals for dependence, no positive effect has a 95% interval excluding zero. The +/-3 margin is an analysis threshold, not a clinically validated one, and smaller margins support fewer equivalences. Two fixed-probe gains near +21 points shrink under the same tuning, with smaller benefits unresolved. We also audit a CHB-MIT protocol shared by at least 14 papers. No tested configuration reproduces DL Table 1 as a whole. These findings concern the tested configurations; the encoder-level probe and subsequent checks were chosen post hoc.

0.30

Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration

cs.LG eess.SP ·2026-10-21 ·Kunkun Zhang, Kehao Wu, Zhitao Chen, Haigen Hu, Qianwei Zhou
top venue similarity 0.58
Abstract · Accepted for publication in IEEE Transactions on Instrumentation and Measurement (TIM), 2026

Recently, electroencephalography (EEG)-based brain--computer interfaces (BCIs) have gained traction as portable neural measurement systems. However, the practical deployment of these instruments is often hindered by nonstationarity and cross-subject distribution shifts, which lead to significant intersubject inconsistency. Existing adaptation methods remain impractical for real-time measurement scenarios, as they typically require offline access to source or aggregated target data. To address these challenges, this article proposes memory-augmented online test-time adaptation (OTTA) with perturbation consistency and confidence calibration (MOPC), a source-free framework designed to enhance the reliability of BCI instrumentation. MOPC enables the measurement system to update its decoding parameters on the fly during the inference stage, facilitating single-pass adaptation without accessing sensitive source data. We introduce random-mask perturbations to enforce prediction consistency against inherent EEG signal noise and acquisition artifacts. Furthermore, a confidence-calibrated reweighting loss is designed to integrate feature-space similarity, effectively mitigating unreliable pseudolabels and class imbalance during continuous signal acquisition. To ensure system stability and prevent the catastrophic forgetting of established neural patterns, a lightweight memory module is incorporated to regularize parameter updates within a tight latency budget. Evaluated on the BCI IV IIb and OpenBMI datasets, MOPC achieves state-of-the-art performance, outperforming prior methods by 2.22~\% and 3.67~\%, respectively, while keeping the per-trial adaptation latency to approximately 40--60 ms. This study provides a robust, recalibration-free solution for real-time EEG decoding, marking a significant advancement in the precision and usability of practical BCI measurement instruments.

0.22

iMINDBench: iEEG Multi-Institution Neural Decoding Benchmark

cs.LG ·2026-09-16 ·Geeling Chau, Saba Hashemi, Yonghyeon Gwon, Eshani Patel, Jan DeWitt +7 more
benchmark similarity 0.56
Abstract · 26 pages, 13 figures

Intracranial electroencephalography (iEEG) is widely used to record electrical activity directly from electrodes inside the human brain, making it an attractive modality for neural decoding. However, progress in iEEG decoding, especially toward general-purpose foundation models, remains difficult to measure reliably: datasets are task- or institution-specific, limiting evidence of generalization across tasks and recording environments, and preprocessing choices can strongly influence performance, making model improvements difficult to distinguish from preprocessing gains. Thus, we introduce iMINDBench, an iEEG Multi-Institution Neural Decoding Benchmark that evaluates models on a shared suite of fifteen decoding tasks across three naturalistic movie-watching datasets. The benchmark additionally defines standardized preprocessing tracks and fixed evaluation splits to support consistent model comparisons. Using iMINDBench, we find that the evaluated pretrained systems generally outperform baselines within their respective preprocessing tracks, while strong spectral baselines remain competitive across institutional datasets. In our scaling study, adding up to 25 times more supervised data from other subjects or institutions yields only small or task-dependent gains over within-session training. Together, these findings highlight the need for iEEG models that improve on strong preprocessing baselines and make more effective use of data across subjects and institutions. Project website: https://imindbench.github.io/

0.28

Parameter-Efficient Self-Supervised Adaptation for EEG-FM under Fixed Computational Budgets

cs.LG cs.AI ·2026-08-25 ·Meghal Dani, Stefanie Liebe
top venuecode/data similarity 0.56
Abstract

EEG foundation models pretrained via self-supervised learning promise transferable representations, but their generalization remains limited, especially across diverse clinical datasets. Full fine-tuning is impractical for resource-constrained clinical settings due to high computational requirements. In this work, we investigate whether parameter-efficient self-supervised adaptation, updating only 9% of parameters suffices to align representations to target tasks. We evaluate our method on two state-of-the-art models with different pretraining objectives: BIOT (contrastive) and CBraMod (masked reconstruction), and evaluate on three clinical EEG datasets for abnormality detection (TUAB), event classification (TUEV), and seizure detection (CHB-MIT) under both in-distribution and out-of-distribution conditions. SSL adaptation yields consistent gains over linear probing, up to 20x AUCPR. Under a fixed compute budget, peak performance requires only 20--50% of available unlabeled data. Critically, when total window count is fixed, performance remains invariant to patient count, suggesting that performance is dependent on overall temporal window diversity only. Our findings demonstrate that parameter-efficient adaptation enables effective deployment of EEG Foundation models (EEG-FM) with minimal computational overhead and data collection burden. Code available at: https://github.com/c3n-group/efficient-eeg-adapt

0.54

Best Practices in EEG Analysis: Preprocessing, Modeling, and Machine Learning

eess.SP cs.LG ·2026-09-29 ·Parsa Razmara, Woojae Jeong, Aditya Kommineni, Raymundo Cassani, Richard Leahy +1 more
published similarity 0.55
Abstract · 38 pages, 5 figures. Chapter 16 of the 2026 monograph "Electroencephalogram Signals and Cognition," edited by Hema A. Murthy, Shrikanth Nara…

Electroencephalography (EEG) analysis requires careful choices in preprocessing, statistical modeling, and machine learning because EEG signals are highly susceptible to artifacts, volume conduction, low signal-to-noise ratio, and substantial inter-subject variability. This chapter provides a practical and methodological guide to modern EEG analysis, spanning EEG preprocessing, artifact removal, filtering, bad-channel detection and interpolation, re-referencing, independent component analysis (ICA), and preprocessing of simultaneous EEG-fMRI recordings. We review major approaches for computational EEG analysis, including event-related potentials (ERPs), time-frequency analysis, functional and effective connectivity, source localization, multivariate decoding, permutation testing, and multiple-comparison correction. We then examine machine-learning methods for EEG, from feature-based classifiers to deep learning and emerging EEG foundation models, with emphasis on cross-subject generalization, limited-data regimes, data leakage, evaluation metrics, and fair benchmarking. Reproducibility is treated as a core requirement throughout, including transparent preprocessing, BIDS-EEG data organization, standardized derivatives, preservation of raw data, and FAIR data practices. The chapter is intended as a practical reference for researchers developing reliable, interpretable, and reproducible EEG analysis and machine-learning pipelines.

0.47

VoxReason: Auditing Source-Grounded Speech Plans Before Synthesis

cs.SD cs.CLcs.LGeess.AS ·2026-09-02 ·Mengzhe Geng
benchmark similarity 0.55
Abstract

Plan accuracy alone cannot show whether a speech-delivery decision follows its source: a fixed prior may match the original label yet fail to respond appropriately when a cue changes. VoxReason provides a 100-case verifier benchmark that holds each utterance fixed, edits one designated source-label cue, and scores cited evidence, eight plan fields, and the permitted response. On a source-key-disjoint test of 24 cases, a source-emotion prior reaches plan-slot accuracy 0.958, but none of the 24 edited neutral targets appears in its training labels; its required-change accuracy is 0.000. This diagnoses the support boundary of this prior, not its performance on supported edits. In a complementary 32-case emotion-disjoint test, the prior has seen all edited neutral targets but neither original test emotion; its plan-slot accuracy is 0.219 and required-change accuracy is 1.000. The partitions reuse and overlap the same 100 cases, so these deterministic diagnostics are not independent cohorts or learned-planner results. The benchmark evaluates derived labels and structured plans, not audio input, generated speech, or listener judgments.

0.24