CS Paper Radar

LesionAgent: Training-Free Agentic Tumor Tracking and Response Assessment in Longitudinal CT

Maximilian Rokuss, Jeya Maria Jose Valanarasu, Alejandro Lozano, Benjamin Hamm, Yannick Kirchhoff, Fabian Isensee, Klaus Maier-Hein

cs.CV cs.AIcs.MA ·submitted 2026-11-20 17:21 UTC · v1
code/data

Abstract

Every few months, a cancer patient's CT scans decide whether treatment continues. 3D foundation models can now detect, segment, register and track lesions, yet none of them reads the scans as a radiologist does. A radiologist decides which findings are lesions, which are the same lesion months later and whether a new spot means progression, and checks each decision against the extensive rules of a clinical guideline. We introduce LesionAgent, an LLM agent that performs this read end to end without task-specific training. It operates frozen 3D models as tools, acts in 3D through coordinate-labelled views, remembers every lesion across visits in a registry, verifies every model output it relies on, and leaves every number to a deterministic guideline engine. On four public longitudinal CT datasets, LesionAgent tracks more lesions and measures them more accurately than every automatic baseline, and where the same 3D models chained by fixed rules call progression falsely at 33 of 56 follow-ups, it does so twice. On clinical follow-up CTs, it agrees with the radiologists' response at 20 of 23 follow-ups, including every change in response, and without training on DeepLesion, it retrieves more of its lesions than every tracker trained on it (89.0% vs. 87.4%). Its harness, not its LLM, makes the difference: given the same LLM and 3D models but not the harness, Claude Code reaches a detection F1 of 41% and LesionAgent 78%, and an open-weight LLM that can run inside the hospital rises from 6% to 73%. LesionAgent and a napari reading app for any LLM are available at https://github.com/MIC-DKFZ/LesionAgent.

Closest papers

Nearest neighbours by meaning across the whole index.

Learning a Rule Bank to Revise 3D CT Reports with Independent Evidence

cs.CV cs.AI ·2026-11-20 ·Renjie Liang, Mengxian Lyu, Zijian Xu, Boxin Zhao, Yang Yang +5 more
code/data similarity 0.70
Abstract

Vision--language models can generate fluent radiology reports from 3D chest CT scans, yet they may still omit abnormalities or misstate findings. Independent image analysis using models separate from the report model provides additional observations, but acting on uncertain evidence may introduce new errors. We propose an agent system that learns a revision policy represented as an executable rule bank for each report model. Inspired by experience banks, the agent proposes and refines rules using revision outcomes across development cases. During inference, the retained rules guide local edits using independent classifier predictions and quantitative image measurements without retraining the report model. Unedited sentences are preserved, and each change is linked to the rule that triggered it. On CT-RATE, revision increases CE-F1 by 11.5 points for SelfCue-KD and 0.9 points for NV-Reason-CT, with gains across five draft-sampling seeds. SelfCue-KD's CT-FineBench score also increases by 15.2 points. Draft-only rule learning yields limited gains, while the two image-evidence sources provide complementary benefits for abnormality detection. Measurements also supply numerical details missing from the drafts. These results support learning model-specific rules to control how independent image evidence informs report revision. Code is available at https://github.com/renjie-liang/CT-RuleBank.

0.47

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

cs.CV cs.LG ·2026-09-08 ·Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang +1 more
similarity 0.70
Abstract · 18 pages, 4 figures

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.

0.21

From Given to Gathered Evidence: Agentic Learning for Longitudinal Medical Reasoning

cs.CV ·2026-09-30 ·Minye Shao, Chaohui Yu, Yixuan Wu, Fan Wang, Ling Shao +4 more
benchmarkcode/data similarity 0.66
Abstract · Code: https://github.com/VinyehShaw/CASE ; Hugging Face: https://huggingface.co/CASE-Bench

Foundation models can serve as clinical agents through tool-use harnesses. However, conventional medical benchmarks assess reasoning over preselected evidence rather than the ability to seek it across clinical records and longitudinal imaging. We propose CASE: a series of role-specific Clinical Agents for Seeking Evidence, together with a tool-use harness and an agentic post-training framework for compact vision-language policy models. We further introduce a longitudinal multimodal benchmark built on UK Biobank, comprising 50,401 clinical questions derived from real-world ICD-10-coded diagnoses of 4,739 participants. Each question links to a patient-specific environment containing clinical context and multi-sequence MRI from baseline and follow-up visits, where agents autonomously select which visits, organs, modalities, slices, and specialist tools to inspect and compare. Supervised fine-tuning transfers evidence-seeking workflows from 147,434 frontier-model interaction trajectories, followed by agentic reinforcement learning on the learner's own environment interactions. Privileged on-policy self-distillation and rubric-based LLM feedback refine evidence-to-conclusion reasoning without prescribing tool sequences. Experiments show that CASE moves beyond question-answer imitation toward transferable investigation policies, strengthening evidence-grounded longitudinal reasoning. Under matched evaluation conditions, our Qwen3-VL-8B-Instruct based agent achieves over 16% and 10% relative improvements in answer accuracy over GPT-5.4 and Claude Opus 4.8. Project page available at: https://vinyehshaw.github.io/case-project/.

0.33

ActiveMedAgent: Cost-Aware Trajectory Learning for Multimodal Medical Diagnosis

cs.LG cs.AIcs.CLcs.CV+1 ·2026-10-08 ·Weiwei Ma, Xiaobing Yu, Peijie Qiu, Jin Yang, Zhaoqi An +3 more
top venue similarity 0.65
Abstract · EMNLP 2026

Clinical diagnosis is inherently sequential: clinicians escalate from cheap to costly tests only when additional evidence is expected to resolve diagnostic uncertainty. We present ActiveMedAgent, a framework that brings this cost-aware sequential logic to multimodal medical AI. Given a frozen, API-accessed vision-language model, ActiveMedAgent tracks probability distributions over candidate diagnoses and scores each acquisition by its per-step diagnostic utility minus cost. A lightweight MLP controller is then trained offline on these scored trajectories, learning when to request additional evidence and when to commit. Across three commonly used benchmarks, trajectory-based policy learning consistently outperforms both unguided acquisition and full-modality baselines. Notably, we identify an information overload effect. In 175 cases, the agent produces a correct diagnosis with fewer channels while the full-modality baseline fails, showing that learning what to omit can be as important as learning what to acquire.

0.37

Improving Calibration of Black-Box Radiology AI Using Test-Time Augmentation

cs.LG cs.HC ·2026-09-24 ·Nathan Le, Magdalini Paschali, Arogya Koirala, Andrew Johnston, Zhongnan Fang +3 more
publishedcode/data similarity 0.65
Abstract · 11 pages, 3 figures, 1 table. Accepted at the MICCAI 2026 Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imagin…

Radiology AI systems increasingly inform clinical decisions such as triage, follow-up imaging, and treatment planning. For these decisions to be made safely, model outputs must be well calibrated, meaning predicted probabilities accurately reflect true risk. Many standard techniques for improving calibration, such as MC Dropout and Deep Ensembles, require access to model parameters or retraining. However, proprietary clinical AI systems operate as black boxes, preventing access to the model's internals. To that end, we propose a model-agnostic framework for improving calibration of black-box models using clinically grounded test-time augmentation (TTA). Our framework applies geometric and physics-inspired 3D CT perturbations and learns probability-level aggregation strategies without access to model internals or the original training data. Across pulmonary embolism and intracranial hemorrhage detection tasks, DualTTA achieved the strongest overall calibration among TTA methods, reducing the Expected Calibration Error by 54% (0.239 -> 0.109) and 43% (0.051 -> 0.029), respectively, while requiring only input-output access. Additionally, DualTTA outperformed uncertainty estimation techniques that require access to model internals, such as Temperature Scaling, MC Dropout, and Deep Ensembles, in most calibration metrics. These results demonstrate that learned TTA aggregation can improve the calibration of clinical AI systems, providing a practical approach for improving the reliability of black-box medical AI.

0.45

A 3D foundation model unifying CT interpretation and segmentation

cs.CV ·2026-11-04 ·Yulu Xie, Zilong Li, Shen Xu, Yifan Bai, Liuhong Shi +12 more
similarity 0.64
Abstract · 114 pages, including Supplementary Information; 7 main figures and 2 Extended Data figures

Radiologists interpret computed tomography (CT) scans by jointly determining what a finding represents and where it lies in three-dimensional (3D) anatomy. However, CT models have treated CT interpretation and 3D segmentation as separate tasks, leaving textual findings spatially unverifiable and overlooking potential synergy between clinical understanding and spatial perception. Here we present HoloCT, a generalist 3D foundation model unifying CT interpretation and voxel-level segmentation by jointly modelling whole-volume context and fine-grained anatomical detail, providing 3D masks as evidence. We curated HoloDATA, comprising 195,921 CT scans from 73 public datasets and six clinical cohorts, with 6.2 million instruction dialogues and 2.8 million CT-mask pairs. Across 346 tasks spanning segmentation, lesion screening, visual question answering, and report generation on 61 internal and 12 external datasets, HoloCT outperformed specialist and foundation models. In multicentre validation across 11,455 clinical CT scans from five hospitals, HoloCT outperformed competing models in lesion segmentation and report generation by 18.2 and 15.3 points. It also achieved 85.1% mean accuracy in screening thyroid tumours and colon lesions, exceeding all four participating radiologists in a retrospective reader study. Further analyses revealed bidirectional semantic-spatial synergy: language-guided segmentation delineated unseen anatomical structures and lesions as well as diffuse free-text findings, outperforming the leading approach by 22.1 points, whereas prompting the model to generate corresponding 3D masks alongside its textual outputs significantly improved interpretation performance. HoloCT shows that clinical understanding and spatial perception can be learned together within a single foundation model and offers a path towards more accurate and reliable CT analysis.

0.23

OpenTumorBoard: A Real-World Benchmark of Multidisciplinary Tumor Board Discussion Trajectories

cs.CL cs.LG ·2026-09-26 ·Anqi Li, Zhixuan Ge, Yixuan Duan, Jiarong Qian, Chi-Yu Chen +7 more
benchmark similarity 0.64
Abstract · Preprint. Includes supplementary material. Added dataset and leaderboard links

Multidisciplinary tumor boards integrate multimodal clinical observations and longitudinal patient histories through specialist discussions, yet benchmarks rarely capture these real-world trajectories. We introduce OpenTumorBoard, a benchmark with 611 patient cases and 19,157 discussion turns across ten specialist roles, transcribed from 12,534 minutes of publicly available tumor board recordings on YouTube. The benchmark evaluates two settings: SPECIALIST TURN, in which an LLM responds to a clinically significant question posed during a real discussion, and BOARD SIMULATION, in which it generates an entire back-and-forth discussion and reaches a consensus on therapy recommendations, surgical plans, next actions and clinical trial matching. Evaluation of 14 general-purpose frontier and medical LLMs reveals substantial limitations: the best models score 3.43 out of 5 in clinical equivalence to specialist answers and 2.78 out of 5 in alignment with recorded board conclusions. Supervised finetuning and reinforcement learning improve performance on a held-out test set, suggesting that real-world discussion trajectories can support model adaptation. Three M.D. experts review a subset of the benchmark, finding high information coverage and factuality of patient cases and strong fidelity of extracted consensus conclusions. We will release OpenTumorBoard and its automated curation pipeline to support the development and evaluation of LLMs for multidisciplinary, personalized cancer decision-making.

0.21

CT-$Δ$Bench: A Benchmark for Longitudinal 3D Medical Imaging Difference Reporting with Vision-Language Models

cs.CL cs.CV ·2026-08-12 ·Kegeng Tang, Jingbo Wang, Shaogang Ren, Zihao Wang
publishedbenchmark similarity 0.64
Abstract · Accepted by COLM 2026

In medical imaging, the clinical value of Computed Tomography (CT) lies not only in depicting current disease status, but crucially in enabling longitudinal comparison of serial scans to determine disease evolution, a process that underpins response assessment, recurrence detection, and ongoing patient management. Yet, despite this central role of temporal comparison in clinical decision-making, existing medical foundation models remain largely confined to single-study understanding, leaving temporally grounded cross-examination insufficiently addressed. To address this gap, we study longitudinal imaging difference reporting, a task in which a model takes two temporally separated scans from the same patient and generates a clinically meaningful report describing interval changes between them. We introduce CT-$Δ$Bench, a dedicated benchmark for this task with patient-level splitting to prevent information leakage. To better evaluate this task beyond surface-level text similarity, we further develop change-aware metrics specifically designed to capture clinically meaningful longitudinal changes, and conduct an independent physician validation to assess the reliability of the synthesized references and event extraction pipeline. We also compare direct paired-CT reasoning with an indirect two-stage pipeline that first generates single-timepoint reports and then performs textual differencing. Finally, we propose DeltaMed, a baseline model for direct paired-CT difference reporting, and train it on the benchmark training set. Together, these contributions lay the groundwork for temporally aware medical foundation models that better reflect real-world longitudinal clinical reasoning.

0.49