CS Paper Radar

US-Seg: One Reference for Universal Ultrasound Segmentation

Chen Ma, Yunshu Li, Shuyu Liang, Qin Wang, Junhu Fu, Zeju Li, Yi Guo, Yuanyuan Wang

eess.IV ·submitted 2026-11-21 11:21 UTC · v1

Abstract

Recent ultrasound foundation models have demonstrated strong feature extraction capabilities across organs, tasks, and imaging conditions. However, converting these representations into segmentation still requires finetuning on annotated target data. To reduce reliance on task-specific finetuning, existing universal ultrasound segmentation methods typically adopt prompt-based target specification, mainly through spatial prompts in SAM-style models or task prompts exemplified by MOFO. Yet, directly segmenting targets unseen during training still requires repeated per-image interaction or target-specific adaptation. We propose US-Seg, a universal ultrasound segmentation framework that uses only a single annotated reference to specify the target and directly predicts its mask in query images without finetuning. The fundamental insight of US-Seg is to reformulate segmentation from direct image-to-label mapping for predefined targets into a shared structural recovery process learned from heterogeneous reference-query pairs through masked label reconstruction, thereby making a single reference sufficient for target specification. Boundary-centric label masking emphasizes ambiguous boundaries, encouraging transferable structural cues rather than target-specific appearance patterns. Using these structure-enriched representations, multi-level bidirectional reference-query interaction aligns the reference-defined target with the query. Finally, a prediction-aware iterative decoder uses intermediate predictions to progressively correct residual structural errors under reference guidance. Without repeated interaction or laborious annotation, US-Seg achieves an average Dice of 81.85% across six evaluations covering cross-site and cross-task generalization, outperforming the strongest label-reference method by 24.30%, while also delivering the best in-domain performance.

Closest papers

Nearest neighbours by meaning across the whole index.

Dual Co-Train: Cross-Dataset Ultrasound Tongue Segmentation Under Extreme Data Scarcity

cs.CV cs.AI ·2026-08-18 ·Alisher Myrgyyassov, Zhen Song, Bruce Xiao Wang, Yu Sun, Min Ney Wong +2 more
similarity 0.69
Abstract

Ultrasound tongue contour segmentation remains challenging under cross-dataset domain shift, where limited annotations, probe variability, and acquisition noise often degrade model generalization. We present a source-free domain adaptation framework for robust ultrasound tongue segmentation built on a lightweight UltraUNet backbone. Starting from a checkpoint pretrained on only five labeled source images, simulating an underfitted constrained source model, the proposed method adapts to a fully-unlabeled target domain by iteratively refining pseudo-labels, filtering unreliable masks with a contour-based quality-control module, and generating target-style synthetic image-mask pairs through a segmentation-guided conditional GAN. The student model is then trained on a mixture of clean pseudo-labeled target images, noisy pseudo-labels with consistency regularization, and synthetic samples, enabling closed-loop adaptation without access to source data. We evaluate the method on 12 source-target transfer pairs across eight ultrasound tongue imaging datasets, and conduct source-size scaling experiments and ablation studies. Across all comparisons, the proposed framework improves segmentation overlap and contour accuracy over the baselines, including supervised ones. These results suggest that task-specific pseudo-label refinement and synthetic target-style augmentation can substantially improve source-free adaptation for ultrasound tongue imaging.

0.21

Topology-Informed Prompt-Conditioned Universal Segmentation of Uterine Structures from Ultrasound and MRI

cs.CV cs.AI ·2026-10-05 ·Yongheng Sun, Yuexi Gu, Jingwen Sun, Maureen Kohi, Mingxia Liu
code/data similarity 0.69
Abstract · 4 pages, 2 figures, 3 tables. Code: https://github.com/YonghengSun1997/TPUS

Multi-structure segmentation of the uterus is important for computer-assisted screening, diagnosis, and treatment planning of uterine diseases, where ultrasound and MRI provide complementary clinical information. However, developing a unified model across these modalities is challenging due to their substantially different image appearances, anatomical contexts, spatial resolutions, and label spaces. Moreover, existing datasets often define different segmentation targets, making joint learning challenging and potentially leading to negative transfer across heterogeneous tasks. To this end, we propose a Topology-informed Prompt-conditioned Universal Segmentation (TPUS) framework for segmenting multiple uterine structures across ultrasound and MRI. TPUS introduces a graph-based multi-dataset backbone comprising modality-specific stems and a modality-shared graph-based encoder-decoder to support modality-sensitive input adaptation, structural feature reasoning, and joint representation learning across heterogeneous uterine segmentation tasks. In addition, TPUS uses task-aware class prompts to condition the segmentation process for different datasets and label spaces, a dynamic convolutional adaptation module to generate task-specific output responses, and a topology-informed loss to encourage anatomically consistent predictions. Experiments on a uterine ultrasound dataset and a T2-weighted uterine myoma MRI dataset demonstrate that TPUS achieves Dice scores of 0.898 and 0.693 on the two held-out test sets, respectively, outperforming several generic and universal segmentation baselines. Source code can be accessed at https://github.com/YonghengSun1997/TPUS.

0.30

UltraG-Bench: A Multi-task Benchmark for assessing Large Vision-Language Models on Pixel-level Evidence Grounding in Ultrasound

cs.CV cs.AI ·2026-09-25 ·Quanhao Zhu, Bo Xu, Rui Lin, Chenyuan Wang, Yu Shao +5 more
benchmarkcode/data similarity 0.68
Abstract

Ultrasound is one of the most widely used medical imaging modalities, and recent large vision-language models(VLMs) have shown increasing capabilities in ultrasound image understanding. However, these models fail to provide pixel-level visual evidence aligned with their semantic predictions, and their fine-grained grounding capability in ultrasound remains largely unclear. We introduce UltraG-Bench, a large-scale multi-task benchmark for evaluating pixel-level evidence grounding in ultrasound. UltraG-Bench is built by annotating 40 public ultrasound segmentation datasets spanning 13 anatomical categories, and comprises three progressive tasks: instruction-guided segmentation, evidence-grounded VQA, and evidence-grounded report generation, with 331125, 666779, and 138832 annotations, respectively. Comprehensive evaluation of 14 state-of-the-art models reveals a substantial gap between semantic understanding and fine-grained pixel-level localization. We further propose UltraG-Agent, which combines the semantic reasoning capabilities of a VLM with the ultrasound-specific segmentation capability of UltraSAM3. Experiments show that UltraG-Agent substantially improves both semantic prediction and pixel-level visual grounding. Our dataset and code are available at https://github.com/zhuqh19/UltraG-Bench.

0.60

CVP-BAA: Efficiently Adapting Segment Anything Model for Medical Image Segmentation

eess.IV ·2026-10-22 ·Mei Wang, Minghui Li, Libin Lan
code/data similarity 0.67
Abstract · Submitted to CVIU, 35 pages, 8 tables, 8 figures. Our code is available at \href{https://github.com/WangMei-wm/CVP-BAA}{here}

Various task-specific medical segmentation models have demonstrated strong performance, their heavy reliance on extensive annotations and highly specialized architectures limits their versatility, scalability, and clinical applicability. Recently, adapting vision foundation models, particularly the segment anything model (SAM), has emerged as a promising alternative. However, prevalent parameter-efficient fine-tuning (PEFT) strategies, such as prompt tuning and adapter tuning, often lack an explicit mechanism to embed local structural priors into the long-range dependency modeling of vision transformers (ViT), rendering them insufficiently sensitive to fine-grained details. To address these limitations, we introduce CVP-BAA, a novel hybrid PEFT method that improves SAM's sensitivity to domain-specific textures and local details, leading to superior boundary delineation. The proposed CVP-BAA adopts two key ideas. First, it introduces a convolutional visual prompting (CVP) strategy that leverages convolutional features as structural priors, prepending them to the key and value projections within the multi-head self-attention layers of strategically selected ViT blocks. Through a dedicated prompt generation-and-injection module, this mechanism effectively bridges local spatial details with global context semantics. Second, a boundary-aware adapter (BAA) is designed as a parallel branch to the feed-forward network within the same selected blocks. By explicitly computing and amplifying high-frequency components, the BAA enhances feature representations along tissue boundaries and fine-grained lesion structures. Extensive experiments on five benchmarks across three imaging modalities demonstrate that CVP-BAA achieves superior segmentation performance, surpassing existing task-specific models and PEFT-based SAM adaptations in both quantitative metrics and qualitative results.

0.38

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

cs.CV ·2026-09-16 ·Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar +2 more
code/data similarity 0.67
Abstract · The PDF includes the Supplementary Information. Code is available at https://github.com/AlfredQin/sonobase

Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.

0.36

Beyond Report Imitation: Clinically Aware Multi-Image Ultrasound Report Generation from Visible Evidence

cs.CV cs.AI ·2026-10-08 ·Yuchen Yang, Xin Wang, Lufan Wang, Yinghong Pan, Yujuan Feng +1 more
publishedbenchmarkcode/data similarity 0.67
Abstract · Accepted to BMVC 2026. Code: https://github.com/NiHaoWoJiaoYYC/CAMEO

Generating ultrasound reports from multiple images requires aggregating clinical evidence across views, yet archived key frames capture only part of the dynamic examination. Raw-report imitation is therefore misaligned with visual supervision: content that is clinically valid for the full examination may be unverifiable from the images available to a model. This gap creates a clinical behavior alignment problem. A model must preserve visible findings, avoid diagnostic reversals and unsupported completion, and not collapse into conservative templates. We propose CAMEO, a Clinically Aware Multi-image Evidence-grounded Orchestration framework for ultrasound report generation. Stage I learns ultrasound visual-language primitives; Stage II performs Cross-View Evidence Grounding by distilling trusted visible report points into multi-image QA and report-style supervision; and Stage III performs Clinically Aware Preference Alignment using clinical-error-oriented preference pairs. From USReport, we construct USReport-Distilled with 17,670 evidence-grounded paired-image training instances and USReport-Pref with 21,869 preference pairs; we additionally use 25,631 PubMedVision-US ultrasound instruction samples for domain adaptation and multi-image instruction tuning. On the primary USReport-Distilled benchmark, CAMEO improves over EchoVLM from 0.25 to 0.40 BLEU-1, 0.28 to 0.45 ROUGE-1, and 0.27 to 0.43 METEOR, while raising ClinicalScore from 55.02 to 74.20. These results underscore the value of evidence-grounded supervision, clinically aware alignment, and clinically structured evaluation for reliable ultrasound report generation.

0.45

ReSA: Preserving Reference-Specified Foreground in In-Context Segmentation

cs.CV ·2026-11-20 ·Dezhao Su, Bingxu Hou, Jingdi Lei, Lin Qian, Likai Wang +1 more
similarity 0.67
Abstract · 35 pages, including appendices

In-context segmentation uses annotated references to specify the target and its extent in a query image. Accurately transferring this reference-specified foreground requires recovering target regions while suppressing irrelevant predictions. We propose ReSA, a reference-guided framework that unifies query adaptation and mask selection through a shared reference kernel. ReSA leverages foreground and background reference prototypes to constrain prediction changes during adaptation and guide foreground selection through reference-weighted reconstruction. This shared guidance promotes consistent use of reference information across prediction refinement and mask formation. ReSA further selects among adapted predictions and aligns boundary refinement with the selected foreground threshold. We establish a theoretical bound connecting reference-response changes during adaptation and soft reconstruction. With a frozen visual encoder and lightweight test-time adaptation, ReSA requires no offline task training. Ablation studies demonstrate improved foreground retention and effective suppression of false-positive regions, while qualitative results show more complete masks with fewer isolated artifacts. Across ten object, part, and cross-domain segmentation benchmarks, ReSA achieves the highest average mIoU among the evaluated methods, reaching 62.6% in 1-shot and 71.8% in 5-shot.

0.27

Expert-like Bone Ultrasound Segmentation through Expert-in-the-loop Mask-conditioned Progressive Learning

eess.IV cs.CV ·2026-08-31 ·Arash Tavangar, Larissa K. Chiu, Hamidreza Khodashenas, Gregory K. Berry, Amir Hooshiar
top venue similarity 0.67
Abstract

Manual annotation remains a major bottleneck in ultrasound (US) bone segmentation, where experts typically iteratively refine rough brush masks rather than delineating precise contours in a single pass. We present ExiL, a mask-conditioned progressive learning framework that models annotation as a structured refinement trajectory. ExiL combines a synthetic expert-like brush simulator based on signed distance fields with a lightweight 7.8M-parameter U-Net that learns to complete and refine imperfect masks from US images. During deployment, an expert mode updates the model directly from accepted refinements, enabling continual adaptation to expert behavior. Evaluated using UltraBones100k cadaver data for quantitative segmentation and a prospective volunteer dataset for annotation-efficiency analysis, ExiL reduced single-expert average annotation time from 60 to 20 seconds per frame (66.7\%) and improved mean Dice by approximately 0.045 over non-progressive training, while achieving 0.87 Dice and 2.7 px boundary error in the best trajectory-aware setting. With 10--50 ms inference, ExiL enables real-time, self-improving annotation for US-guided orthopedic workflows in practical clinical labeling.

0.66