CS Paper Radar

Reconstructing 3D+t Cardiovascular Flow From Sparse Planar Velocity Fields With Neural Fields

Viraj Patel, Deblina Bhattacharjee, Katharine Fraser

cs.CV cs.LG ·submitted 2026-11-23 14:43 UTC · v1

Abstract

Reconstructing time-resolved three-dimensional (3D+t) cardiovascular flow from sparse planar measurements is challenging because each plane observes only the two in-plane velocity components, on a small part of the volume. We propose a plane-aware neural-field framework that learns a continuous 3D velocity field from space and time coordinates through a per-plane projection, and then investigate the potential benefits of physics constraints. We evaluate the framework on computational aortic and aneurysm datasets, and on planes resampled from a real cardiac 4D Flow MRI scan. A plain multi-layer perceptron (MLP) was more accurate than classical radial basis function (RBF) interpolation on both computational datasets. For the aorta, a physics-constrained SIREN (PC-SIREN) reduced the rRMSE further to $0.3756$, compared with $0.4273$ for the plain MLP and $0.7256$ for RBF, and it was the most accurate model in every anatomical segment of the MRI data. For the aneurysms the plain MLP remained the most accurate model, with an rRMSE of $0.07$ to $0.16$ against $0.55$ to $0.71$ for PC-SIREN. Further experiments investigated scanning configuration, number of scans, and spatial resolution. These findings show that continuous neural fields can reconstruct volumetric cardiovascular flow from sparse planar measurements, and that physics constraints have to be matched to the flow.

Comment
10 pages, 6 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

cs.CV ·2026-11-02 ·Yusuf A. Ozturk, Jie Zheng, Fanwei Kong
similarity 0.69
Abstract

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

0.04

CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

cs.CV physics.med-ph ·2026-11-10 ·Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
similarity 0.68
Abstract · Under review

Objective: To improve the spatial and temporal resolution of aortic 4D flow MRI through a unified deep learning framework for post-acquisition super-resolution (SR) of reconstructed velocity vector fields. Methods: We propose CURRENT, a recurrent neural network that performs spatial and temporal SR with a single network architecture. Supervised training was conducted using paired low- and high-resolution datasets generated by embedding computational fluid dynamics simulations of aortic flow into in vivo thoracic MRI backgrounds, followed by controlled spatial and temporal downsampling. CURRENT was evaluated for two-fold spatial and temporal SR against 4DFlowNet and for two-fold spatiotemporal SR against sequential spatial and temporal SR pipelines based on 4DFlowNet. Image-based and k-space-based quantitative metrics were considered and conventional interpolation were used as baselines. In addition, the impact of CURRENT's spatiotemporal SR on physics-informed relative pressure estimation was assessed. Finally, the ability of CURRENT to generalize from synthetic training data to in vivo acquisitions was investigated. Results: CURRENT achieved superior spatial SR performance and comparable temporal SR performance to dedicated 4DFlowNet models while providing a unified solution for both tasks. Simultaneous spatiotemporal SR using CURRENT yielded more accurate relative pressure estimates than either spatial or temporal SR alone and outperformed sequential 4DFlowNet-based spatial and temporal SR approaches. Furthermore, the proposed model demonstrated promising generalization to in vivo 4D flow MRI data despite being trained exclusively on synthetic datasets. Conclusion: CURRENT provides a unified framework for spatial and temporal SR of 4D flow MRI. The proposed approach has the potential to enhance physics-based analysis and broaden the applicability of accelerated 4D flow MRI.

0.17

Physics Informed Neural Network model for the dynamical study of Abdominal Aortic Aneurysm

cs.AI physics.flu-dyn ·2026-09-14 ·Adrián Robles Arques, Martín Ruiz Fernandez, Javier Sanchis, Miguel A. Teruel, Juan Trujillo
similarity 0.67
Abstract · 38 pages, 9 figures and 2 tables

We present the development and application of a three-dimensional Physics-Informed Neural Network (PINN) framework for the investigation of haemodynamic behaviour in the human aorta. The model incorporates a time-resolved simulation of pulsatile blood flow over a two-minute interval, enabling the extraction of pressure and velocity fields with high temporal fidelity. The mechanical stress exerted on the aortic wall was quantified through Laplace's law, with temporal averaging applied to derive representative stress distributions. This approach circumvents the computational overhead associated with conventional computational fluid dynamics (CFD) methods by eliminating mesh generation and exploiting the automatic differentiation capabilities inherent to neural networks. The proposed methodology demonstrates that PINNs can serve as an efficient and accurate alternative for modelling complex vascular flow phenomena, offering significant advantages in scalability and computational cost reduction while maintaining physical consistency.

0.20

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.66
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Learning Incompressible 3D Flows from Sparse Samples: A Set Transformer Approach to Divergence-Free Kernel Fitting

cs.LG cs.AIcs.CE ·2026-10-12 ·Ramzi Idoughi, Radouan Boukharfane, Peter Wonka
similarity 0.65
Abstract · 33 pages with supplement materials, 9 figures

Recovering divergence-free velocity fields from sparse and corrupted observations requires reconciling physical consistency, expressive representations, and robustness to missing data. We introduce DFK-Former, a set-to-field transformer that reconstructs divergence-free velocity fields from sparse, noisy, and irregularly sampled 3D observations. The model is inherently invariant to the number and ordering of input samples and predicts the parameters of a divergence-free kernel representation, producing continuous, mesh-free velocity fields that satisfy incompressibility exactly by construction rather than approximately through soft constraints or projection operators. Unlike existing divergence-free kernel approaches, which estimate kernel coefficients via a separate optimization for each field, DFK-Former predicts these coefficients directly in a single forward pass. This eliminates costly iterative fitting while providing a learned prior that enables accurate reconstruction even when observations are insufficient to uniquely determine the field. To enhance representational power, we introduce adaptive and anisotropic divergence-free kernels that preserve exact incompressibility guarantees while capturing more complex flow structures. Extensive experiments across varying levels of sparsity, noise, and occlusion, including transfer to real Direct Numerical Simulation (DNS) turbulence data, demonstrate substantial gains in both accuracy and efficiency. DFK-Former reduces endpoint error by up to 4.6x compared to per-field divergence-free-kernel optimization, while reconstructing each field in 7.5 ms instead of 9.8 s, yielding a speedup of more than three orders of magnitude. These results establish direct, feed-forward prediction of divergence-free kernel parameters as a practical and effective paradigm for physically consistent velocity-field reconstruction from sparse observations.

0.22

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

cs.LG physics.med-phphysics.flu-dyn ·2026-08-31 ·Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
similarity 0.65
Abstract

Quantifying mitral regurgitation severity remains limited by the assumptions of clinical flow convergence methods, while high-fidelity simulation and volumetric velocimetry are too slow for routine use. We investigate whether a learned solution operator can reconstruct transient three-dimensional transvalvular hemodynamics from the sparse observation an in-vitro experiment actually provides: a single planar velocity slice and two boundary pressure traces. A Deep Operator Network is pretrained on an experimentally benchmarked URANS database spanning eleven mitral regurgitation orifice phantoms, learning a mapping from a masked two-component planar velocity snapshot to the surrounding volumetric field, and is subsequently adapted to unseen target cases by fine-tuning on their sparse measurements. Adaptation reliably corrects the flow topology within the supervised plane, reorienting a strongly eccentric jet that the pretrained operator predicts as straight, and yields full-field predictions in minutes rather than the days required by the underlying simulations. Its influence decays sharply with distance from that plane, however: measured against phase-resolved particle image velocimetry, the reconstruction error rises from 24.6% at 2mm to 52.6% at 6mm, and the resulting mismatch between corrected and uncorrected layers degrades physical consistency. Single-plane supervision thus constrains the observed plane far more effectively than the surrounding volume, which we identify as the principal obstacle to coherent 4D reconstruction from sparse planar data.

0.18

Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections

cs.CG cs.CV ·2026-09-14 ·Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
top venue similarity 0.65
Abstract · 11 pages, 2 figures

X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learning-based 2D-to-3D reconstruction methods typically require wide angular coverage or multiple views, assumptions that are rarely satisfied in routine practice where only two projections with narrow angular separation are available. To address these challenges, we propose NeCA++, a multi-stage self-supervised neural radiance field (NeRF) framework tailored to clinically realistic acquisition constraints. The framework decomposes reconstruction into two stages that progressively refine spatial support and representation capacity. In the first stage, a coarse 3D representation of the vasculature is reconstructed, restricting the subsequent optimisation to regions with a higher likelihood of vessel presence, termed an active region. Afterward reconstruction is restricted to this region while higher-resolution representations are progressively activated to recover fine vascular details. This multi-stage strategy focuses learning on anatomically plausible regions, mitigates gradient dilution under extreme sparsity, and stabilises global topology before recovering fine vascular branches. Furthermore, two vessel-specific regularisations are introduced: a ray-aligned constraint to reduce projection-induced ambiguity, and a bimodal density penalty to enable early vessel-background separation. Extensive experiments across three datasets (ImageCAS, ASOCA, and Synthetic RCA) and four angular configurations demonstrate consistent superiority over state-of-the-art baselines, particularly under clinically realistic narrow-angle settings, while achieving reconstruction within 58 seconds per case.

0.29

Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations

cs.CV ·2026-09-03 ·Hinrich Rahlfs, Julio Garcia, Chiara Manini, Markus Hüllebrand, Sebastian Schmitter +11 more
code/data similarity 0.64
Abstract · Submitted to Journal of Cardiovascular Magnetic Resonance

Automated aortic segmentation in 4D flow MRI is essential for reproducible hemodynamic assessment but is limited by scarce dense annotations and high computational demands. We developed a fully automated 4D (3D+time) U-Net for segmenting the ascending aorta, arch, and proximal descending aorta, using a parameter-efficient hybrid 4D kernel to capture temporal context and sparse 4D labels derived from existing 2D expert contours and centerlines, thereby avoiding the need for dense 4D annotations. Training comprised 268 scans from 8 centers and 2 vendors, with evaluation on an internal test set (32 scans) and an external post-contrast set (30 scans; different site, protocol, and annotator), compared against frame-wise 3D networks and two semi-automatic references. Against time-resolved annotations, the 4D U-Net achieved Dice scores of 0.927 (internal) and 0.911 (external), versus 0.919/0.847 for the 3D U-Net, 0.893 for static PC-MRA, and 0.808 for registration-based propagation; differences were small in systole but pronounced in diastole. Agreement with expert contours for peak velocity, net flow, axial and circumferential wall shear stress, and diameters was excellent (ICC >=0.954 internal, >=0.980 external), while semi-automatic references performed worse. The method thus provides reproducible, time-resolved aortic segmentation for automated hemodynamic analysis and generalizes across multicenter, multivendor, and independent post-contrast data. The model is publicly available.

0.45