CS Paper Radar

Leakage-Safe Auditing of Attribution-Driven Data Curation in Medical Imaging

Malay Phadke, Akshay Gokhale

cs.CV cs.AI ·submitted 2026-11-23 17:39 UTC · v1
top venue

Abstract

When can an attribution-derived anomaly justify changing a medical-imaging training set? We formulate attribution-driven curation as three separately testable claims: anomaly detection, harmfulness estimation, and intervention utility. We test the first and third using a patient-disjoint, identifier-preserving audit of a 3D convolutional classifier for computed tomography angiography aneurysm candidates. We identify 232 exactly zero-valued arrays among 1,201 positive patches, including 170 training positives, and invalidate a historical 321-patch attention-failure subgroup whose identifier-free records were joined to files by position. On the held-out test set, GradCAM++ spatial concentration is central for every candidate class, reversing the historical pattern. GradCAM++ and Integrated Gradients show negative rank-order agreement for positives, limiting method-independent anatomical interpretation. Across five paired training seeds, removing the 170 corrupted training positives yields AUC 0.9617 +/- 0.0044 versus 0.9652 +/- 0.0039 for full-data training (difference -0.0035; 95% CI -0.0082 to 0.0007). Excluding 34 raw-zero test positives widens rather than closes the gap, countering a blank-memorization explanation. Budget-matched random-removal controls suggest the result is not simply an effect of reducing training size. Input corruption does not necessarily imply that deletion improves generalization. Our framework makes leakage control, sample identity, and intervention testing explicit in attribution-driven medical-imaging data curation.

Comment
14 pages, 4 figures. Accepted to the Findings Track of the Machine Learning for Health (ML4H) Symposium 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Auditable CT Phenotyping Through Report-derived Radiological Observations

cs.CV ·2026-08-26 ·Riga Wu, Walter Witschey, Yicheng Li, Felix Barajas Ordonez, Keno K. Bressem +7 more
similarity 0.65
Abstract

Medical image foundation models can predict clinical phenotypes from computed tomography (CT), but strong performance leaves open whether they read disease-specific findings or shortcuts that correlate with the diagnosis. We tested this in 221 electronic-health-record (EHR) phenotypes using Auditable CT phenotyping (ACT), built on report-derived radiological observations. We trained ACT on 38,317 patients, mined 376,194 observations and evaluated it in 25,183 held-out patients. ACT exceeded five vision-language baselines on zero-shot annotation, and CT-CLIP across 221 phenotypes from unseen CT pulmonary angiography, both under zero-shot scoring (0.651 versus 0.572) and under linear probing (0.709 versus 0.662). Reading each probe exposes what accuracy conceals: only 97 observations occupy the 221 rank-1 positions, and one phrase describing aortic and coronary calcification ranks first for 20 phenotypes, including osteoporosis, urinary tract infection and major depressive disorder. Restricting the bank to clinician-specified evidence redirects those probes onto phenotype-related observations in 86 phenotypes at no accuracy cost (0.751 versus 0.741). Accurate CT-based EHR phenotyping can therefore rest on observations that are not valid evidence for the coded phenotype and that ACT can identify and intervene on.

0.53

Scores That Hold, Benchmarks That Leak: Measuring Dataset Contamination in Public Brain-Tumor MRI Classification

cs.CV cs.AI ·2026-09-30 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.63
Abstract

Automated classification of brain tumors from MRI is a heavily published application of deep learning in medical imaging, with reported accuracies on public benchmarks routinely exceeding 98%. However, accuracy does not capture a critical dimension of benchmark quality: dataset integrity, defined as the independence of test from training data at the image, patient, and acquisition-source levels. We introduce a three-layer contamination framework comprising duplicate, patient, and source-label leakage to assess the public corpora on which this literature rests. We audit the three most widely used corpora against a chest-radiograph negative control and quantify each layer's effect on measured performance across nine architectures and three evaluation conditions. Contamination is severe at every layer: 28.8% of the dominant corpus's official test split has a near-twin in its own training split, a second corpus leaks 22.3% of its test images byte-identically, 95.5% of traceable test images share a patient with training, and file-header features containing no anatomy separate tumor from no-tumor at 0.959 balanced accuracy, at parity with fine-tuned ResNet backbones. The unexpected result is that removing every identified leaked test image leaves balanced accuracy essentially unchanged: stable performance after deduplication does not establish benchmark integrity. Our findings establish dataset integrity as a distinct, measurable axis of benchmark quality that a stable leaderboard cannot certify. For biomedical research, reported accuracy on these corpora alone does not establish that a model has learned to recognize tumors rather than exploit dataset-specific cues. We release the contaminated-file lists, recovered patient identifiers, and deduplicated splits.

0.43

From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

cs.CV cs.AIcs.LG ·2026-10-21 ·Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
position similarity 0.63
Abstract

While generated chest radiographs can serve as valuable data augmentation when explicitly declared, the same pixels become unsupported evidence when submitted as records of real clinical examinations. We study this dataset-intake vulnerability by disentangling three questions: (1) whether an image passes an automated technical quality check, (2) whether an origin classifier flags it as synthetic, and (3) whether a trusted provenance record supports the claimed clinical acquisition. In this study, a submitter uses Qwen3.8-27B to select up to 20 candidate radiographs from pools of 1,000 Cheff-identified or SynthCheX images, while a receiver evaluates image quality via MedGemma 1.5 and predicts origin using a linear probe over frozen DINOv3 features. Although quality selection increases MedGemma quality passes from 12/20 to 19/20 for Cheff-identified images and from 8/20 to 17/20 for SynthCheX, we find no evidence that candidate selection increases passage through both checks simultaneously: zero selected Cheff-identified images pass both gates, and uniform, quality-guided, and surrogate-guided selection yield 2, 1, and 2 SynthCheX passes out of 20, respectively. On unprocessed test cohorts, the origin classifier rejects 4,677 of 5,000 SynthCheX images at a nominal 5% false-alarm rate (flagging 110 of 2,297 real NIH radiographs), yet leaves 152 SynthCheX images that pass both pixel-level checks. Moreover, pixel-level screening is fragile to routine distribution shifts: JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841, and applying the NIH-calibrated threshold to an external genuine cohort (Open-I) triggers false alarms on 568 of 957 authentic radiographs (59.4%). Because pixel-level checks can filter submissions but cannot verify clinical acquisition claims, we argue that dataset intake pipelines must record and verify source provenance independently of image pixels.

0.13

Unsupervised Anomaly Detection for Image Dataset Quality Assurance in Multi-Center Breast MRI

cs.CV cs.AI ·2026-08-17 ·Chiara Tappermann, Steffen Renisch, Lars Ole Schwen, Hans Meine, Horst K. Hahn +1 more
benchmark similarity 0.63
Abstract

Corrupted, inconsistent, or anomalous data silently threatens the safety and reliability of medical AI. Despite growing regulatory recognition of dataset quality assurance (QA) for high-risk medical AI, scalable automated detection remains underdeveloped. We employ unsupervised anomaly detection (AD) and out-of-distribution (OOD) detection as an automated dataset QA mechanism for multi-center dynamic contrast-enhanced breast MRI. We build a controlled AD benchmark of 17 realistic QA-relevant anomaly types from six public datasets (protocol violations, processing errors, incorrect anatomical regions) and propose a taxonomy of radiological image anomalies based on human visual perception, enabling fine-grained analysis of AD failure modes. The benchmark includes near-, medium-far-, far-OOD samples, as well as in-distribution and external normal data. Four methods are evaluated: a projection-based method extended with a domain-specific feature extractor and a novel positional encoding, a reconstruction-based approach extended to full 3D volumes with an augmented training objective, and two unmodified hybrid OOD detection methods. Medium-far- and far-OOD samples are detected reliably, whereas near-OOD samples and external normal data from unseen institutions expose method-specific differences. The 3D reconstruction-based approach best balances detection performance (AUROC: 0.936) and generalization to unseen institutions. The projection-based method with positional encoding achieves the highest overall detection performance (AUROC: 0.954). Both hybrid methods exhibit critical failure modes, confirming that methods validated for one modality or anatomy may not generalize without domain-specific adaptation. Implants and mastectomies remain an open challenge for all methods. Our results establish a foundation and practical guidance on scalable unsupervised QA in medical AI pipelines.

0.20

MADJEPA: Enhanced Multi-Stage Joint-Embedding Predictive Architecture for Medical Anomaly Detection

eess.IV cs.AIcs.LG ·2026-11-18 ·Ioana-Sabina Stoian, Florinel-Alin Croitoru, Vlad Hondru, Andreea Iuliana Ionescu, Andrei Paun +1 more
publishedcode/data similarity 0.62
Abstract · Accepted at WACV 2027

Anomaly detection in medical images is a complex task, requiring the development of a robust model using only healthy patient data. Without access to labeled data, modern approaches typically employ self-supervised learning to obtain a model of normality. Since world models promise to build strong internal representations of their environment, we consider them as suitable candidates for the medical anomaly detection environment, namely medical investigations of healthy patients. To this end, we propose MADJEPA, a medical anomaly detector based on an enhanced multi-stage joint-embedding predictive architecture (JEPA). We design a multi-stage training pipeline to produce a robust detector: (1) image-based JEPA (I-JEPA) training aims to learn a strong representation of normal training data; (2) target encoder distillation aims to modulate over-generalization of I-JEPA representations to abnormal data; (3) pseudo-anomaly classification aims to calibrate anomaly predictions by learning a tight boundary around the normal data manifold. To demonstrate our design, we carry out comprehensive experiments on six datasets covering various medical image domains (e.g.~MRI, OCT, X-ray, histopathology), comparing our MADJEPA with numerous state-of-the-art methods. The results show that our carefully designed world model, MADJEPA, attains competitive results, ranking first on three datasets. Our ablation studies further confirm the utility of each training stage, indicating that I-JEPA alone is not sufficient to obtain competitive results in medical anomaly detection. We publicly release our code at https://github.com/Sabina085/madjepa.

0.38

TAME: Token Attribution and Masking for Emergent misalignment

cs.LG cs.AIcs.CL ·2026-09-15 ·Md Rayhanul Masud, Md Rizwan Parvez
similarity 0.62
Abstract · Accepted at EMNLP UncertaiNLP Workshop 2026

Fine-tuning an aligned language model on narrow, flawed data can induce harmful behavior far outside the training domain, known as emergent misalignment (EM). Prior work has localized EM in model weights, activations, and training documents, but it remains unclear which training tokens carry the relevant fine-tuning signal. We introduce TAME (Token Attribution and Masking for Emergent Misalignment), a three-stage framework: token attribution scores how strongly the fine-tuning update raises each response token's likelihood, using forward passes through a released LoRA adapter; signal characterization finds patterns among high-attribution tokens; and causal validation tests them by attribution-guided loss masking. On released EM organisms and a 6,849-example medical-advice split, attribution is concentrated (the top 5% of tokens hold 32% of the mass) and, in Llama, depleted for medical vocabulary but enriched for a register of unwarranted certainty, even after controlling for token rarity. Masking high-attribution tokens during fresh fine-tuning cuts EM by 23x in Llama and 36x in Qwen, with the perplexity cost concentrated on the targeted register rather than on medical content; an equal random mask leaves EM unchanged. In Llama, the attribution pattern suggests that EM-relevant signal lies more in how confidently flawed content is expressed than in its domain vocabulary; the causal masking effect itself holds across both model families.

0.52

LAPIS: Clinically Constrained Patient-Identity Residual Learning for Chest X-Ray Anonymization

eess.IV ·2026-10-29 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Désiré Sidibé
similarity 0.62
Abstract · 5 pages, 3 figures, 2 tables. Submitted to IEEE ISBI 2027

Biometric information in chest radiographs limits their release for research, as patients can be re-identified. We propose LAPIS, which jointly adapts a spatial chest-radiograph latent space so that patient-discriminative information concentrates in a compact, replaceable channel residual while most clinically relevant content stays in the complement. The residual is defined by an exactly semi-orthogonal basis, a spatial adversary suppresses identity leakage from the complement, and replacement-aware training teaches the decoder cross-patient residual swaps under output identity, clinical and realism constraints, so that replacing the residual yields a valid image. At release, the residual is replaced by a mixture of donor residuals. On patient-disjoint model, release and test sets from ChestX-ray14, we evaluate attackers adapted to the anonymized setting, a structural source-retrieval attack, and pathology classifiers trained on released images and tested on real ones. LAPIS reduces worst-case cross-study linkability from 0.961 to 0.791 AUC at a macro AUROC cost of 0.012 relative to reconstruction; a deformation-based baseline, however, remains better at structural source retrieval.

0.17

Fusing Spectral Signatures and Activation Clustering for Backdoor Detection in Healthcare Imaging Models: Method, Implementation, and Evaluation

cs.CR cs.LG ·2026-09-13 ·Suresh Tamang
benchmarkcode/data similarity 0.62
Abstract · 13 pages, 2 figures, 3 tables. Implementation available at https://github.com/tsurace37/aegis-scan . Also deposited at Zenodo, doi:10.5281/z…

Machine learning models are increasingly deployed in healthcare imaging pipelines for diagnostic support, and training-time attacks against them are a named sector-level concern: healthcare-sector guidance identifies model poisoning and adversarial attacks as threats requiring dedicated defenses, while federal policy directs expanded AI vulnerability-detection tooling to critical infrastructure operators such as rural hospitals. Spectral signature analysis and activation clustering are two established backdoor detection methods routinely evaluated as independent baselines, but their outputs are not ordinarily combined, and reported detection performance on medical imaging benchmarks remains sparse relative to the natural-image setting. This paper contributes three things: a score-level fusion rule combining per-class spectral ranking with activation-clustering flags into a single per-sample poisoning score and a model-level agreement statistic; an open-source implementation of the resulting eight-stage pipeline; and an evaluation of that pipeline against synthetically poisoned variants of a public medical imaging benchmark and CIFAR-10 at four poisoning rates (0%, 1%, 5%, 10%) over five seeds each, measuring each detector alone against the fusion. On the medical benchmark, the fused detector reaches AUROC >= 0.99 at every nonzero poisoning rate tested. On CIFAR-10, fusion does not uniformly help: at 10% poisoning, activation clustering's true-positive rate collapses to 0.000 and spectral AUROC independently degrades to near-chance (0.545), despite a 97.2% attack success rate confirming the backdoor was fully installed. The fused score, a weighted combination of both signals, inherits this joint failure. Detection output is expressed in NIST AI RMF Measure-function and MITRE ATLAS terms, so findings are reported in the vocabulary security and compliance teams already use.

0.45