CS Paper Radar

Passivity Shaping over Frequency Bands: A Differentiable Optimization Approach

Alberto De Luca, Pol Jane-Soneira

eess.SY ·submitted 2026-11-25 11:58 UTC · v1
theory

Abstract

The energy transition replaces traditional inertial synchronous machines with power electronic converters, introducing new grid stability challenges. Passivity provides a compositional input-output framework for assessing stability in interconnected grid subsystems, yet tuning controllers for this property over specific frequency ranges - a practical requirement in converter-dominated grids - still relies largely on practitioners' experience, typically based on intuition or trial and error. We address this gap in three steps: (i) we formulate the passivity index over arbitrary frequency bands as the optimal value of a parametric Semidefinite Program (SDP) using the generalized KYP (gKYP) lemma; (ii) we derive analytical sensitivities of this optimal value with respect to controller parameters via the Envelope Theorem; and (iii) we embed these elements in a bilevel optimization scheme that tunes controller parameters to maximize the passivity index. We validate the proposed method on two case studies of increasing complexity: a grid-following converter and a multi-converter microgrid.

Closest papers

Nearest neighbours by meaning across the whole index.

$\mathcal{H}_\infty$ Grid-Forming Control in DC Microgrids

eess.SY ·2026-11-19 ·Jovan Krajacic, Ognjen Stanojev, Mario Schweizer, Gabriela Hug
similarity 0.67
Abstract · Submitted to IEEE Transactions on Power Electronics

The growing share of DC-based generation, storage and loads has increased interest in DC microgrids. As a result, DC-bus voltage regulation and stability have become active research topics, with considerable effort directed at improving the transient performance of conventional droop control. Although numerous variants of droop algorithms have been proposed, many rely on increasingly complex control structures with multiple tuning parameters and measurements, thereby increasing the commissioning burden. Moreover, stable interaction with the surrounding microgrid is not guaranteed by design. To address these issues, this paper develops a passivity-constrained $\mathcal{H}_\infty$ synthesis method for the DC-bus voltage controller. The proposed $\mathcal{H}_\infty$ controller emulates the desired grid-forming behavior of the converter by minimizing the $\mathcal{H}_\infty$ error norm between device-level performance indices and their desired values, while additionally enforcing passivity during the optimization. The novel $\mathcal{H}_\infty$ control scheme is benchmarked in the frequency domain against representative droop-based and virtual-DC-machine algorithms from the literature, while experiments on a four-converter DC microgrid corroborate the frequency-domain analysis and validate the practical applicability of the algorithm.

0.16

Decentralized Control Barrier Function Filters for Frequency Containment With Inverters

eess.SY ·2026-11-25 ·Damola Ajeyemi, Emiliano Dall'Anese
similarity 0.67
Abstract · 15 pages, 8 figures

This paper addresses the design of safety filters for grid-following (GFL) inverters in power transmission systems. The goal of the filters is to constrain frequency nadir and zenith following generation-demand imbalances, by supplementing primary frequency control. Using a reduced electromechanical model and control barrier functions (CBFs), we define an ideal filter through a convex quadratic program (QP). The ideal QP filter renders the set of admissible frequencies forward invariant; however, its direct implementation is impractical, as it requires centralized implementation and model-based computation. We then use a dual proximal formulation and a two-time-scale implementation to obtain decentralized dynamic filters that can be implemented at each inverter and use only local frequency and rate-of-change-of-frequency estimates. To assess the performance and the ability to regulate frequency, we derive bounds on the distance between state trajectories under the dynamic and ideal CBF filters. The bounds quantify the effects of the filter time constant, initialization, load variation, and frequency estimation errors, and provide estimates of possible frequency-limit violations. We validate the proposed method on the IEEE 39-bus system using a high-fidelity electromagnetic-transient (EMT) model.

0.22

Systematic SDP Search for Decentralized Stability Certificates

eess.SY ·2026-10-02 ·Andrey Gorbunov, Youhong Chen, Janusz Bialek, Balarko Chaudhuri, Jin Ma +2 more
similarity 0.67
Abstract

Decentralized stability certificates allow inverter-based resources to be connected to a grid without repeating a system-wide small-signal study. Passivity provides such certificates but is violated by practical grid-forming (GFM) controls at low frequency, and its generalizations---transformation matrices, extended passivity indices, loop shifting, and gain--phase conditions---rely on multipliers that are constructed analytically or chosen heuristically. All of these certificates are linear matrix inequalities in their multipliers at every frequency, so the search for the least conservative multiplier is a convex semidefinite program (SDP) with a global optimum and a definite infeasibility verdict. This paper demonstrates how SDP can be applied to searching for optimal multipliers for some decentralized methods proposed in the literature. Then it illustrates the methodology by presenting a systematic search algorithm for the fully plug-and-play additive nodal-admittance certificate, which requires no assembled network model and holds for arbitrary interconnections. Only sampled frequency responses are needed, making the search compatible with black-box models and impedance scans. Chebyshev parameterization together with adaptive frequency splitting provides a piecewise-polynomial multiplier without manual partitioning. On the IEEE 39-bus system with ten droop-controlled GFMs, this multiplier certifies a larger region of droop gains than piecewise-constant multipliers, as confirmed by simulation of random inverter placements.

0.44

Passivity-Based Decentralized Stability Criterion and Active-Damping Design for DC Microgrids

eess.SY ·2026-11-23 ·Zelin Sun, Shanshan Jiang, Xiaoyu Peng, Xiuqiang He, Hua Geng
similarity 0.65
Abstract

Interactions among converter-interfaced devices can destabilize DC microgrids (DCMGs). In practice, detailed device models often cannot be disclosed to the system operator for centralized stability analysis, and only some device controllers can be redesigned. This paper develops an output-feedback passivity (OFP)-based decentralized small-signal stability criterion for DCMGs with both fixed-controller and tunable-controller devices. By incorporating the certified OFP indices of fixed-controller devices into an equivalent network, the criterion quantifies a locally verifiable OFP requirement for each tunable-controller device. Full-order analysis further reveals that the finite current-loop bandwidth imposes upper bounds on the OFP indices of droop-controlled converters, which can remain negative for any PI gains despite positive predictions based on reduced-order analysis. Guided by the criterion and these bounds, an OFP-oriented active damping (OFP-AD) strategy is proposed for these converters. The proposed strategy improves the OFP index toward the required value while preserving the cascaded PI control and droop characteristics, using output-capacitor-current feedback. Case studies on a 39-node DCMG validate the proposed criterion and OFP-AD.

0.18

Decentralized and Equilibrium-Set-Oriented Stability Analysis and Control for Power Systems

eess.SY ·2026-08-31 ·Peng Yang, Liaoyuan Yang, Feng Liu
similarity 0.61
Abstract · 12 pages, 7 figures, 4 tables

Conventional power-system stability analysis is largely centralized and centered on a single equilibrium point, which becomes increasingly restrictive in the presence of large-scale fluctuating renewable generation. This paper develops a decentralized framework for stability analysis and control that certifies the asymptotic stability of an equilibrium set rather than that of a given single operating point. To this end, we introduce a new notion termed input--output differential passivity (IODP), which decomposes equilibrium-set stability of the interconnected system into local requirements imposed on individual devices. These requirements are formulated without embedding a particular operating equilibrium into the local conditions; once the certified regions are constructed, stability verification for a given operating scenario reduces to checking whether its equilibrium lies in the certified set. The proposed conditions require each bus to possess a sufficient level of IODP, quantified by an IODP index. To compensate for an IODP shortage, we further develop an I/O-transformation-based passivation controller that reshapes the local input--output behavior of the corresponding device. In this way, all grid-connected components can be made to satisfy the decentralized conditions for system-wide stability. The proposed framework is validated on a modified IEEE 39-bus system. Simulation results demonstrate that it provides a scalable and equilibrium-set-oriented solution for stability certification and control under highly variable operating conditions.

0.23

Optimal Allocation of Grid-Forming Frequency Shaping Control

eess.SY ·2026-09-21 ·Zhaomin Lyu, Ding Zhang, Yan Jiang
similarity 0.60
Abstract

Various inverter-based control strategies have been proposed to improve frequency security for power systems with high renewable penetration. Among them, the grid-forming frequency shaping control is particularly promising due to its ability to shape the post-contingency aggregate system frequency dynamics into first-order with prescribed rate of change of frequency (RoCoF) and steady-state frequency deviation. Moreover, the shaped aggregate dynamics depends on the harmonic sum of all inverter transfer functions rather than on their distribution. In light of this, here we explore how to allocate shaping control resources to minimize the transient control effort needed to achieve ideal coherent dynamics. We formulate it as a constrained optimization problem by tackling two main difficulties. First, we make the squared $\mathcal{H}_2$ norm legitimate quantification of transient control cost under step power imbalances through a system transformation. Second, we simplify the $s$-domain constraint for Nadir elimination into a standard constraint that is easy to implement in optimization. The resulting non-convex optimization problem can be solved by existing successive convexification method. The effectiveness of the allocation has been verified on the modified Icelandic Power Network test case.

0.28

Relative-Degree Wall Restricts Passivity-Based Stability Analysis in Inverter-Dominant Grids

eess.SY ·2026-08-30 ·Xiaoyu Peng, Zhongze Li, Xi Ru, Xinghua Chen, Feng Liu
top venue similarity 0.58
Abstract

This letter reveals a fundamental limitation of passivity-based distributed stability analysis in power systems. Under the standard formulation, passivity certification inherently imposes a relative-degree compatibility constraint that excludes many high-fidelity inverter dynamic models (e.g., those that include electromagnetic transients). Potential extensions of passivity frameworks are discussed to break this limitation.

0.43

Beyond Scalar Inertia: Frequency-Response-Based Assessment of Finite-Duration Inertial Support in Grid-Forming Converters

eess.SY ·2026-11-13 ·Ziqi Zhou, Mahdieh S. Sadabadi, Sante Pugliese, Xiaoqiang Li, Xiaojie Wu +1 more
hot direction similarity 0.57
Abstract · This paper has 6 pages with 5 figures. The target journal will be determined at a later stage

Conventional scalar inertia characterizes only the low-frequency terminal behavior of grid-forming converters (GFMs) and cannot fully predict inertial energy delivery during short-duration frequency disturbances. This letter proposes a frequency-response-based method to assess finite-duration inertial support using complex terminal power--frequency responses, such as those provided by Network Frequency Perturbation (NFP) plots. For GFMs with nonzero steady-state droop, a duration-dependent energy-equivalent inertia is defined after subtracting the ideal static-droop contribution. An exact spectral relationship is established, expressing this metric as a duration-weighted integral of frequency-dependent inertia, without requiring knowledge of the internal controller structure and parameters. The duration dependence of the metric is further shown to encode observable oscillation frequencies and damping ratios. A coefficient-decoupling GFM control with identical scalar inertia and droop across different settings is used for verification.

0.27