CS Paper Radar

$\mathcal{H}_\infty$ Grid-Forming Control in DC Microgrids

Jovan Krajacic, Ognjen Stanojev, Mario Schweizer, Gabriela Hug

eess.SY ·submitted 2026-11-19 21:21 UTC · v1

Abstract

The growing share of DC-based generation, storage and loads has increased interest in DC microgrids. As a result, DC-bus voltage regulation and stability have become active research topics, with considerable effort directed at improving the transient performance of conventional droop control. Although numerous variants of droop algorithms have been proposed, many rely on increasingly complex control structures with multiple tuning parameters and measurements, thereby increasing the commissioning burden. Moreover, stable interaction with the surrounding microgrid is not guaranteed by design. To address these issues, this paper develops a passivity-constrained $\mathcal{H}_\infty$ synthesis method for the DC-bus voltage controller. The proposed $\mathcal{H}_\infty$ controller emulates the desired grid-forming behavior of the converter by minimizing the $\mathcal{H}_\infty$ error norm between device-level performance indices and their desired values, while additionally enforcing passivity during the optimization. The novel $\mathcal{H}_\infty$ control scheme is benchmarked in the frequency domain against representative droop-based and virtual-DC-machine algorithms from the literature, while experiments on a four-converter DC microgrid corroborate the frequency-domain analysis and validate the practical applicability of the algorithm.

Comment
Submitted to IEEE Transactions on Power Electronics

Closest papers

Nearest neighbours by meaning across the whole index.

Distributed Droop-Free Control of Grid-Forming Inverters with Dynamic Line and Load Modeling

eess.SY ·2026-09-07 ·Hiya Akhil Gada, Marija Ilic
similarity 0.68
Abstract

Droop-free distributed control has emerged as a promising alternative to conventional linear droop control for coordinating inverter-based resources in AC microgrids. However, existing droop-free methods typically rely on quasi-steady state network models that neglect fast electromagnetic transients and assume a decoupled dependence of active and reactive power on frequency and voltage, respectively. In this paper, we propose a transient-aware droop-free distributed primary/secondary control framework for grid-forming (GFM) inverters. The control objective is to achieve proportional active and reactive power sharing, frequency regulation, and voltage regulation within prescribed bounds. The proposed approach incorporates dynamic models of network lines and loads into the control design, enabling accurate representation of transient behavior while capturing the coupled nature of power flow interactions. A gradient-based distributed control update is derived from an optimization formulation, in which voltage magnitude constraints are enforced through a projection operator. To validate the performance of the proposed control, real-time simulation studies are conducted on a four-inverter microgrid under load changes in both strong and weak grid conditions. The results demonstrate that the proposed method improves transient performance, particularly in weak grids, while preserving the same steady state operating conditions as existing QSS-based droop-free approaches.

0.21

Improved Droop Control in DC Microgrids via Voltage-Locked Loop Synchronization

eess.SY ·2026-09-18 ·Ognjen Stanojev, Jovan Krajacic, Enea Bianda, Orcun Karaca, Mario Schweizer
similarity 0.63
Abstract

DC microgrids are low- or medium-voltage networks designed to connect and manage DC-based sources and loads. A key challenge in operating DC microgrids is maintaining the DC voltage within certain predefined limits while ensuring its stability. Droop control, the most common method towards addressing this challenge, enables decentralized voltage control and power sharing, but suffers from poor transient performance, resulting in voltage dips and overshoots in applications with fast varying loads such as AI datacenters. This paper introduces an improved droop control method based on voltage-locked loop synchronization, which ensures DC voltage stabilization with significantly improved transient response and achieves the desired load sharing between the available source converters. The core design principle is reflected in the functional separation of the control scheme into a virtual DC machine (VDCM) that operates as a spinning wheel and a virtual current source connected in parallel. The transient response is provided by the VDCM to damp and stabilize DC bus voltage variations, while the slow droop response is provided by the virtual current source to ensure steady-state power balance. The performance of the proposed method is validated in an experimental microgrid setup.

0.18

Decentralized and Equilibrium-Set-Oriented Stability Analysis and Control for Power Systems

eess.SY ·2026-08-31 ·Peng Yang, Liaoyuan Yang, Feng Liu
similarity 0.61
Abstract · 12 pages, 7 figures, 4 tables

Conventional power-system stability analysis is largely centralized and centered on a single equilibrium point, which becomes increasingly restrictive in the presence of large-scale fluctuating renewable generation. This paper develops a decentralized framework for stability analysis and control that certifies the asymptotic stability of an equilibrium set rather than that of a given single operating point. To this end, we introduce a new notion termed input--output differential passivity (IODP), which decomposes equilibrium-set stability of the interconnected system into local requirements imposed on individual devices. These requirements are formulated without embedding a particular operating equilibrium into the local conditions; once the certified regions are constructed, stability verification for a given operating scenario reduces to checking whether its equilibrium lies in the certified set. The proposed conditions require each bus to possess a sufficient level of IODP, quantified by an IODP index. To compensate for an IODP shortage, we further develop an I/O-transformation-based passivation controller that reshapes the local input--output behavior of the corresponding device. In this way, all grid-connected components can be made to satisfy the decentralized conditions for system-wide stability. The proposed framework is validated on a modified IEEE 39-bus system. Simulation results demonstrate that it provides a scalable and equilibrium-set-oriented solution for stability certification and control under highly variable operating conditions.

0.23

Grid-Forming AC/DC Converters for Meshed DC Networks via Dual-Measurement Frequency Droop

eess.SY ·2026-10-26 ·Hisham Mahmood, Marcelo A. Elizondo
similarity 0.59
Abstract · 10 pages, 12 figures, 1 table

This paper proposes and analyzes a dual-measurement frequency-droop (DMFD) controller for meshed MVDC networks. Using only two local DC measurements, bus-voltage deviation and a filtered DC-port current or power deviation, the controller enables grid-forming operation at both AC and DC ports across the mesh. Although the DMFD regulates neither the DC voltage nor the DC current directly and acts only on the terminal frequency, it is shown that AC-side synchronization closes an effective DC droop at every synchronized terminal, so that the steady operating point of the mesh exists and is unique. Constant frequency deviations at a terminal and single-terminal islanding enter the same DC equations as equivalent current offsets, with the island frequency fixed by the island power balance, allowing node voltages and branch currents to be obtained from one linear system. The steady-state model yields design-use envelopes to map the droop ratios and the net DC-injection levels into bounds on DC-voltage deviation and terminal currents. A small-signal dynamic model is developed and used to generate eigenvalue loci and damping-ratio charts that guide controller-gain selection. Averaged EMT simulations on a four-terminal ring corroborate the analysis: in regimes where PLL-based grid-following control is known to lose damping, the DMFD controller maintains stable operation and follows the predicted steady-state characteristics.

0.29

Certificate-based Synthesis of Coordinated Droop Control for Heterogeneous Radial Distribution Networks

eess.SY math.OC ·2026-08-11 ·Georgios Pantazis, Michelle Chong
similarity 0.57
Abstract

Voltage certificates for droop-controlled radial distribution networks are often constructed from worst-case quantities. In heterogeneous radial networks, this approach can hide where voltage deviations are most likely. Furthermore, such certificates become increasingly conservative as the network sensitivities accumulate. Leveraging the structure of the linearized DistFlow model and slope-restricted droop controllers, we derive tighter deterministic voltage certificates that retain heterogeneous network, disturbance and inverter characteristics of each bus. The certificates reveal the buses and local limitations that dominate certified voltage performance. Worst-case bounds are recovered as a special case. Although tighter, the heterogeneous certificates can still deteriorate downstream due to the network structure. To address this, we leverage our certificates as design variables for coordinated voltage control. Specifically, we develop a virtual droop architecture with coordination and affine feedforward compensation to reshape the effective voltage sensitivity, and formulate a linear program that jointly synthesizes the controller and minimizes its heterogeneous voltage certificates under operational, communication and inverter placement constraints. The resulting controller guarantees the voltage and inverter bounds for all admissible disturbances. Evaluation on two network benchmarks, a five-customer residential feeder and a 26-customer rural network comprising four feeders, demonstrates improved certificates and voltage behaviour under inverter limits.

0.34

Beyond Scalar Inertia: Frequency-Response-Based Assessment of Finite-Duration Inertial Support in Grid-Forming Converters

eess.SY ·2026-11-13 ·Ziqi Zhou, Mahdieh S. Sadabadi, Sante Pugliese, Xiaoqiang Li, Xiaojie Wu +1 more
hot direction similarity 0.57
Abstract · This paper has 6 pages with 5 figures. The target journal will be determined at a later stage

Conventional scalar inertia characterizes only the low-frequency terminal behavior of grid-forming converters (GFMs) and cannot fully predict inertial energy delivery during short-duration frequency disturbances. This letter proposes a frequency-response-based method to assess finite-duration inertial support using complex terminal power--frequency responses, such as those provided by Network Frequency Perturbation (NFP) plots. For GFMs with nonzero steady-state droop, a duration-dependent energy-equivalent inertia is defined after subtracting the ideal static-droop contribution. An exact spectral relationship is established, expressing this metric as a duration-weighted integral of frequency-dependent inertia, without requiring knowledge of the internal controller structure and parameters. The duration dependence of the metric is further shown to encode observable oscillation frequencies and damping ratios. A coefficient-decoupling GFM control with identical scalar inertia and droop across different settings is used for verification.

0.27

Impact of Grid-Forming Inverter Placement and Penetration on Local and Aggregate Frequency

eess.SY ·2026-11-13 ·Fatma Alfailkawi, Marena Trujillo, Bri-Mathias Hodge
similarity 0.56
Abstract

Modern power systems are undergoing a huge shift in generation mix, including inverter-based resources that are fundamentally changing the stability dynamics of the grid. Thus, synchronous Generators (SG) are gradually being displaced by Grid-forming inverters (GFM) that are proposed as a solution to continue supporting grid stability. However, the effect of GFM placement in the network on frequency performance and how well aggregate-frequency assessment captures placement sensitivity observed in local frequency metrics remains unclear. This paper evaluates all SG and droop-controlled GFM assignments in the IEEE 39-bus system. A reduced-order model is used for the exhaustive search with load disturbances applied separately at every eligible load bus while considering nadir and Rate of Change of Frequency (RoCoF) derived from both device rating weighted aggregate frequency and local bus frequencies. Results reveal that at fixed GFM penetration, placement produced up to 104 mHz variation in worst-case local nadir and 0.21 Hz/s in maximum local RoCoF. Aggregate-frequency assessment reduced the apparent across placements by 89\% for nadir and 88\% for RoCoF at 50\% GFM penetration. These results indicate that aggregate-frequency assessment alone may obscure favorable or adverse placement effects on local frequency performance.

0.28

Enhancing Grid Stability with Synchronverter-Based Control for Grid-Side Converters in Wind Power Systems

eess.SY ·2026-11-02 ·Alan Valadez, George Weiss, Chunjiang Jia, Chong Ng
published similarity 0.56
Abstract

This paper proposes a new synchronverter control strategy for wind turbine grid-side converters, aimed at bolstering grid resilience by providing essential inertial frequency support without the need for additional energy storage components. The strategy harnesses the inherent energy storage capability of the DC-link capacitor to emulate the dynamic behavior of a synchronous generator, effectively contributing to grid inertia. A dual-controller architecture is implemented, consisting of a slow PI controller to maintain DC voltage stability and a fast protection mechanism to prevent overvoltage and undervoltage excursions. Critically, the control scheme facilitates controlled reductions of up to 10% in the DC-link voltage, generating a power reserve that can be strategically deployed for inertia emulation while preserving safe operating limits. The efficacy of the proposed method is validated through simulations of a representative three-turbine wind power plant, incorporating coordinated operation via virtual friction for inter-machine damping and local-global control strategies. Results showcase the superior performance of the proposed strategy compared to conventional grid-following control, emphasizing its potential to significantly improve grid stability and address the increasing challenges posed by high renewable energy penetration.

0.62