CS Paper Radar

Optimal Allocation of Grid-Forming Frequency Shaping Control

Zhaomin Lyu, Ding Zhang, Yan Jiang

eess.SY ·submitted 2026-09-21 13:46 UTC · v1

Abstract

Various inverter-based control strategies have been proposed to improve frequency security for power systems with high renewable penetration. Among them, the grid-forming frequency shaping control is particularly promising due to its ability to shape the post-contingency aggregate system frequency dynamics into first-order with prescribed rate of change of frequency (RoCoF) and steady-state frequency deviation. Moreover, the shaped aggregate dynamics depends on the harmonic sum of all inverter transfer functions rather than on their distribution. In light of this, here we explore how to allocate shaping control resources to minimize the transient control effort needed to achieve ideal coherent dynamics. We formulate it as a constrained optimization problem by tackling two main difficulties. First, we make the squared $\mathcal{H}_2$ norm legitimate quantification of transient control cost under step power imbalances through a system transformation. Second, we simplify the $s$-domain constraint for Nadir elimination into a standard constraint that is easy to implement in optimization. The resulting non-convex optimization problem can be solved by existing successive convexification method. The effectiveness of the allocation has been verified on the modified Icelandic Power Network test case.

Closest papers

Nearest neighbours by meaning across the whole index.

Frequency-Security-Aware Real-Time Economic Dispatch with Data Center UPS Flexibility for Inertia and Primary Frequency Response Services

eess.SY ·2026-11-13 ·Shengyi Wang, Liang Du
hot direction similarity 0.62
Abstract

The increasing penetration of renewable energy and the rapid growth of AI data centers are introducing significant challenges to power system frequency security. There is an urgent need to identify grid-compatible resources capable of providing fast frequency support. This paper proposes a frequency-security-aware real-time economic dispatch (RTED) model that enables data center (DC) uninterruptible power supply (UPS) systems to provide steady-state power balancing, inertia response, and primary frequency response (PFR) services. Specifically, tractable analytical frequency-security constraints are derived and incorporated into the RTED framework through second-order cone programming (SOCP) formulation. The proposed model jointly optimizes energy, reserve, and inertia to minimize system operation cost while preventing under-frequency load shedding (UFLS). Numerical validation on a modified IEEE 39-bus system demonstrates that the proposed RTED model with UPS flexibility can economically support system operation and significantly improve frequency security under active-power deficit disturbances.

0.30

Multi-Period Bilevel Coordination of Primary and Secondary Frequency Regulation for Grid-Forming Battery Energy Storage

eess.SY ·2026-11-04 ·Wenju Shang, Liangliang Hao, Jiangliang Jin, Yunjian Xu
theory similarity 0.60
Abstract

We study the coordination of primary and secondary frequency regulation by grid-forming battery energy storage systems in islanded microgrids. We formulate the coordination as a multi-period bilevel program, in which the upper level schedules secondary regulation setpoints and each lower level computes primary regulation decisions. Using the lower-level Karush-Kuhn-Tucker conditions, we obtain an exact single-level reformulation with complementarity constraints. To address the numerical difficulties introduced by these constraints, we develop a continuation method that couples the complementarity relaxation parameter with the interior-point barrier parameter and warm-starts successive stages. Under the stated boundedness assumptions and with vanishing subproblem residuals, we prove that every accumulation point is feasible and satisfies a first-order stationarity condition for the reformulated problem (C-stationarity). Numerical results for an islanded microgrid show that the proposed method reduces solution time by 89.3% and peak frequency deviation by 0.53% relative to conventional Scholtes relaxation.

0.26

Controller- and Communication-Aware Flexibility Margins for Electric Distribution Networks

eess.SY ·2026-10-14 ·Saif R. Kazi, Kaarthik Sundar
similarity 0.59
Abstract · 11 pages

This paper develops a framework for quantifying operational flexibility in radial electric distribution systems under coupled active- and reactive-load uncertainty. Flexibility is defined as the largest scaling of a prescribed uncertainty set that can be accommodated while satisfying network and actuator limits under a given control architecture. We consider a one-sided Euclidean set for robust demand-growth capability, with a direct extension to bidirectional variations. Under LinDistFlow, controllable distributed resources and feeder-head exchange with the upstream grid jointly balance active-power disturbances, while local Volt/VAR feedback regulates reactive power. The resulting affine closed-loop disturbance response admits exact second-order-cone robust counterparts. For fixed Volt/VAR gains, a convex reformulation jointly optimizes the flexibility margin and active-power participation factors, including feeder-head participation. A sparse load-to-generator feedforward map further captures communication constraints. Numerical studies on the Iowa-240 feeder demonstrate how the amount of control authority and communication structure shape the achievable flexibility margin.

0.24

Approximating Energy-Regulation Feasible Region of Virtual Power Plants: A Data-driven Inverse Optimization Approach

eess.SY math.OC ·2026-08-26 ·Ruike Lyu, Hongye Guo, Qixin Chen
publishedhighly cited similarity 0.58
Abstract · Published in: 2024 IEEE Power & Energy Society General Meeting (PESGM)

System operators will probably allow virtual power plants (VPPs) to submit their feasible region (FR) for market clearing and dispatch. A VPP needs to determine its FR to submit as a whole based on the individual operation model of its internal distributed energy resources (DERs), which is an FR aggregation problem. Existing FR aggregation approaches rely on analytical methods, which have issues with generality and adaptability. In this paper, we propose a data-driven approach to approximate the energy-regulation FR of VPPs. It adopts the virtual battery model to approximate the aggregate FR of a VPP and determines the model parameters through inverse optimization based on generated multi-scenario operation data using the original operation model. Numerical tests verified the accuracy of the proposed method. We believe that our work helps to better leverage the flexibility of DERs.

0.63

Optimal Coordination of Multiple Ancillary Service Provisions in Active Distribution Networks

eess.SY ·2026-11-14 ·Xinbao Jia, Yi Guo, Ognjen Stanojev, Zhen Chen, Yuning Jiang +1 more
similarity 0.58
Abstract · 16 pages

We propose a multi-rate model predictive control (MPC) framework for coordinating primary frequency control (PFC), automatic generation control (AGC), and voltage control (VC) in active distribution networks. The framework allocates distributed energy resource (DER) flexibility among these three ancillary services while retaining their different update rates. To account for the intertemporal flexibility of electric vehicle aggregations and aggregations of buildings with thermostatically controlled loads (TCLs), we incorporate time-varying power-energy envelopes into our multi-rate MPC formulation. These constraints couple the combined PFC and AGC response to the demand-side flexibility available later in the prediction horizon. Furthermore, the input-multirate structure enables coordinated ancillary service provision by DERs with different response dynamics. The controller optimizes the three services together, allowing fast regulation to be coordinated with the developing slow response within the available DER flexibility. We demonstrate the coordinated provision of the three ancillary services through closed-loop simulations on a modified IEEE 33-bus system using a nonlinear differential-algebraic model.

0.25

Grid-Aware Assessment of Forced Oscillations from Spatially Distributed Large Loads

eess.SY ·2026-11-17 ·Min-Seung Ko, Hao Zhu
similarity 0.57
Abstract

This paper develops a unified analytical framework for assessing forced oscillations induced by spatially distributed large-load fluctuations to determine their grid-aware fluctuation magnitudes. Emerging computational loads, such as hyperscale datacenters, present cyclic power variations with dynamic impacts depending on the waveform characteristics, forcing frequency, and source location. Our grid-aware framework represents these fluctuations using deterministic harmonic and probabilistic spectral models, and analyzes the resulting bus-wise frequency deviations based on a generic grid frequency-response model. Deterministic, risk-aware, and band-based probabilistic severity measures are further developed to obtain admissible fluctuation limits under different assumptions on frequency and phase uncertainty. We also formulate a security-constrained (SC) optimization of locational fluctuation magnitudes among existing large loads, accounting for their aggregated frequency deviation level. Case studies on the IEEE 39-bus and 14-generator Australian systems validate the proposed severity measures and admissible limit analysis. The SC optimization results further show that distributing a given amount of aggregate fluctuation toward dynamically less sensitive locations can substantially reduce system-wide oscillation severity.

0.34

Composite Adaptive Higher-Order Control Barrier Functions for Joint Frequency-RoCoF Safety in Low-Inertia SIDS Microgrids

eess.SY eess.SPmath.OC ·2026-09-19 ·Shankar Ramharack, Jonathan Nancoo, Rajiv Sahadeo
top venuetheorycode/data similarity 0.57
Abstract · 6 pages, 7 figures, code available at https://github.com/sramharack/caribcon26-joint-safety-vsg. Accepted to 2026 IEEE Caribbean Conference …

Small Island Developing States (SIDS) face simultaneous frequency nadir and rate-of-change-of-frequency (RoCoF) violations under high renewable penetration. This paper proposes a \emph{Composite Adaptive Higher-Order Control Barrier Function} (CA-HOCBF) for BESS-coupled virtual synchronous generators that jointly enforces IEEE~1547 frequency ($\pm0.8$\,Hz) and ENTSO-E RoCoF ($\pm1$\,Hz/s) limits as hard safety constraints under parametric uncertainty. The method unifies three tools: (i)~a dual barrier architecture with a zeroing CBF for frequency and an algebraic RoCoF constraint with a robust inertia-floor fallback; (ii)~a composite energy function coupling logarithmic safety barriers with quadratic parameter and disturbance error terms, which drives safety-weighted adaptation; and (iii)~a disturbance observer integrated into the barrier dynamics. We prove that the closed-form QP is always feasible under a BESS capacity condition and, under explicitly stated assumptions, that the composite energy remains finite along trajectories, rendering the joint safe set forward invariant \emph{without requiring parameter convergence}. Simulation on a 10\,MW Caribbean microgrid ($H=2$\,s, 70\% renewables) shows the CA-HOCBF eliminates all frequency and RoCoF violations under a compound disturbance, achieving steady-state error of 0.001\,Hz and RoCoF of 0.50\,Hz/s, where fixed-gain VSGs suffer a 0.62\,Hz offset with 2.25\,Hz/s RoCoF violations.

0.51

Resource-Aware Rolling-Horizon Controller for Renewable-Based Virtual Power Plants Providing Automatic Frequency Restoration Reserves

eess.SY ·2026-09-25 ·Marco Vinicio Avendaño-Caiza, Juan Diego Rios-Peñaloza, Javier Roldán-Pérez, José Luis Rodríguez-Amenedo, Milan Prodanovic
similarity 0.57
Abstract · Submitted to a scientific journal for possible publication. 10 pages, 11 figures

Virtual power plants (VPPs) are an effective solution for increasing the penetration of renewable energy sources (RES) in power systems. Moreover, VPPs can provide ancillary services if generators and loads are closely connected and properly coordinated. This aspect has been addressed in several studies, yet they mostly focus on the dispatch optimisation level, leaving real-time operation aspects unresolved. To close this gap, a central controller for VPPs based on a rolling-horizon optimisation is proposed in this work. Its main objective is to maximise revenues while delivering frequency restoration services. A day-ahead optimisation firstly defines the power setpoint and the upward and downward reserves of the VPP. Then, the rolling-horizon optimiser, executed every minute, distributes the power and reserve references between the VPP units to achieve their close tracking while taking into account resource availability (wind speed, irradiance, etc.), operational constraints and battery degradation. The effectiveness of the controller is tested using a two-area interconnected power system under different RES generation and demand profiles. The simulations are performed in MATLAB/Simulink and include detailed dynamic models of the VPP elements, demonstrating the applicability of the algorithm to real systems. The day-ahead and the rolling-horizon optimisation problems are modelled using YALMIP and solved using Gurobi. The obtained results demonstrate the VPP supporting grid frequency restoration by optimally allocating its resources, even under the presence of forecast uncertainty.

0.18