CS Paper Radar

Adaptive Reliability Reserves for Residential Battery Fleets

Maruthi Vemula, Neeraj Praneeth Gajula

cs.LG eess.SY ·submitted 2026-11-25 17:39 UTC · v1
benchmarkcode/data

Abstract

In a Houston 2024 replay, replacing a fixed 20 percent battery reserve with a county-risk threshold raises observed five-hour backup coverage from 75.0 percent to 86.5 percent and adds USD 10.2 in modeled annualized margin per home (paired 95 percent interval: USD +1.7 to USD +21.7). The paired coverage-gain interval includes zero. This is a conditional simulation result, not measured company reliability. Residential batteries face this tradeoff because market discharge consumes energy also needed for household outages. We release HomeFleet-ERCOT, combining observed prices and county outages with identified simulated homes and causal controller inputs. We compare independent-home optimization with 21 proximal policy optimization (PPO) training runs; ten promise-cost candidates span 31.1 percent-96.3 percent backup coverage. Of these, 10 have lower modeled margin than fixed 20 percent, and 3 also have lower coverage. Chronological, geographic, fleet, and storm tests examine transfer. An alert charging override has a conditional energy-and-power sufficiency guarantee, but only 19.5 percent of 41 county mass-outage episodes provide enough continuous warning for every battery preset. Synthetic tests include short, missed, and false warnings, load uplift, capacity loss, and dropout. A static AC audit retains existing feeder violations; aging comparisons expose model sensitivity. The released benchmark, controllers, and checkpoints provide a reproducible basis for comparing these tradeoffs. This work supports the design of residential battery programs that assess market value and household backup service together.

Comment
22 pages, 5 figures; code and artifacts: https://github.com/MaruthiV/homefleet

Closest papers

Nearest neighbours by meaning across the whole index.

State-of-Charge Targets for Storage Participation in Two-Settlement Markets: Reliability, Price, and Compensation Impacts

eess.SY ·2026-11-13 ·Yichen Li, Alexandre Moreira, Ruiwei Jiang, Miguel Heleno, Julie Mulvaney-Kemp
hot direction similarity 0.67
Abstract

As energy storage assumes a larger role in electricity systems, market operation must coordinate its use across time to support reliability during periods of system stress. Minimum state-of-charge (SOC) targets provide a means of preserving energy for these periods, but their design shapes reliability, operating efficiency, and storage compensation. This paper evaluates alternative SOC target designs in a California-based day-ahead and real-time electricity market model. The comparison examines targets based on day-ahead schedules or rolling centralized dispatch, enforced at the individual-resource or system level, across seasons, stress conditions, and participant information settings. The results show that retaining more energy does not necessarily reduce load shedding: targets that restrict discharge can limit storage support during shortages. Under critical summer conditions, individual targets derived from rolling centralized dispatch reduce weekly load shedding by approximately 83--84\% relative to operation without targets. Lower RT clearing costs and average prices can coexist with higher storage compensation, reflecting the role of day-ahead positions and real-time deviations in determining settlement outcomes. These findings highlight the importance of coordinating energy retention with timely discharge and network deliverability when designing SOC requirements for storage participation in electricity markets.

0.20

Distributionally Robust Chance-Constrained Reinforcement Learning for Home Energy Management under Electric Vehicle Uncertainty

eess.SY ·2026-10-18 ·Meng Yuan, Ye Wang, Yi Mei, Ramesh Rayudu, Alan Brent +2 more
similarity 0.66
Abstract

The electrification of residential energy systems and adoption of electric vehicles (EVs) create demand-side flexibility. However, random driving behaviour makes it difficult to ensure EV readiness at departure and maintain thermal comfort. To address this, we formulate residential scheduling as a distributionally robust (DR) chance-constrained Markov decision process, whose 2-Wasserstein ambiguity set guards against tail risk and distribution shift in EV behaviour. The intractable DR chance constraint is then replaced by a sufficient tightened expectation constraint under the nominal distribution. The resulting problem is solved by a Lagrangian soft actor--critic with distributional cost critics, and an online boundary guard enforces EV reachability and thermal comfort within the actuator limits at every step. Five controllers are compared over one year in Wellington, New Zealand, under a degraded forecast. The proposed controller is the cheapest controller that meets the EV target on every day and both chance constraints under forecast error and random driving behaviour. Compared with the rule-based baseline, the only other controller to do so, it lowers the annual cost by 8.6% and the comfort violation hours by 69%. The ablation study confirms that the boundary guard ensures pointwise feasibility within the actuator limits, and the DR chance constraint reduces tail risk.

0.16

Cost-Aware Reinforcement Learning with Action Masking and Projection for Battery Energy Storage Dispatch under Suppressed-Spread Market Shifts

cs.LG cs.AIeess.SY ·2026-09-20 ·Kuanlin Chen, Chen-Wei Kuo, Cheng-En Ou
published similarity 0.65
Abstract · Accepted for publication at IEEE IECON 2026. 6 pages, 3 figures, 3 tables

Battery energy storage system (BESS) dispatch must preserve operational feasibility while declining price spreads reduce the margin available to pay for cycling. We study a proximal policy optimization (PPO) controller whose pre-selection physical action mask and emergency projection are separated from a causal, forecast-informed economic advisory. All forecast-dependent methods receive the same causal 24-step forecast and grid-side settlement. Across five PPO seeds, advice-on net profit is 30.59 and 18.04 USD per 336-hour T1 and T2 window, versus 36.77 and 22.94 USD for proxy-cost MPC; PPO remains below this reference in both periods. Advice raises T2 profit from 16.45 to 18.04 USD while reducing throughput, but is immaterial in T1. On disjoint weekly blocks, PPO is stable under daily, weekly, and blended seasonal forecasts, weakens under persistence, and remains below proxy-cost MPC. Paired diagnostics localize changes to the observed 5-10 USD/MWh regime with mixed SoC-dependent effects. An M0-M6 ablation shows that mask removal sends thousands of infeasible requests to projection, while removing both physical layers exposes ramp violations. The evidence separates economic screening from feasibility enforcement without claiming formal safety, lifecycle-optimal aging, or RL dominance.

0.28

Scarcity Pricing for State-of-Charge Management in Real-Time Markets Under Intra-Day Uncertainty

eess.SY ·2026-11-09 ·Shailesh Wasti, Aravind Retna Kumar, Sushant Varghese, Anthony Giacomoni, Parviz Alivand +2 more
similarity 0.63
Abstract

The growth in renewable resources will increase net load variability and forecast error. Energy storage resources can provide flexibility when ramp capability is limited and contribute to load leveling over the day. The challenge for system operators is how to balance these two functions in real time, when updated net load forecasts are available for a limited lookahead horizon. U.S. electricity markets are seeking ways to manage state-of-charge (SoC) within their energy markets to more efficiently utilize these resources. We propose a method to manage energy storage SoC in a real-time market by extending Hogan's (2013) scarcity pricing framework. A day-ahead SoC schedule is modified using existing multi-interval real-time unit commitment engines as net load forecasts change. To address 30-minute-ahead forecast errors, an updated 5-minute SoC target and a dynamically updated shortage price for violating the constraint are provided to each economic dispatch. We simulate PJM's energy markets for 365 days and demonstrate reliability improvements relative to a strategy that enforces the day-ahead schedule. We show cost reductions and improved price formation relative to a strategy that updates target quantities but uses an administratively chosen shortage penalty.

0.24

Learned Control Variates for Rare Grid-Outage Estimation at Electric Vehicle Charging Stations

cs.AI cs.CEeess.SYstat.ML ·2026-10-19 ·Sulyman Iyanda, Mansur Arief
similarity 0.62
Abstract

Public charging of electric vehicles (EVs) adds a large and synchronized load to the distribution feeders. In most networks, it is rare to overload a feeder at the same time. When it does happen, the consequences can be severe: an overloaded feeder stresses its transformers and can trigger cascading outages across a city. Planners who design for high reliability therefore need to estimate very small outage probabilities. To that end, plain Monte Carlo estimation with an expensive grid simulator can require a prohibitively large number of runs for this task. To reduce the number of runs, we propose a control variate (CV) built from a learned classifier of the outage, trained on cheap observable features such as temperature and load forecasts. We show that for any binary learner, the variance reduction is an explicit function of its recall and false-positive rate. Furthermore, we show that control variate based on a Gaussian proxy of the load loses its effect as outages become rarer, while a learner with non-vanishing precision keeps removing a fixed fraction of the variance even in the extreme rare-event regime. We verify these results in numerical experiments using a feeder-overload simulator across three orders of magnitude of outage probability and obtain that even weak learner with a single feature can remove a quarter of the variance, while a boosted-tree learner is able to remove about 60%. We then apply the estimator to the feeder network of Surabaya, Indonesia, in which the Gaussian load model leaves every feeder three to seven times the one-day-in-ten-years blackout target. At the same simulation budget, planning the reserve with the learned CV and a 95% confidence limit reduces the city-wide blackout days by a third compared with Monte Carlo. These results show that learned control variates can help planners design distribution grids that stay reliable against rare outages.

0.20

Feeder-Aware Service-Conditioned Flexibility of Grid-Interactive Buildings

eess.SY ·2026-10-22 ·Dafang Zhao, Ittetsu Taniguchi, Takao Onoye
similarity 0.61
Abstract

Grid-interactive buildings can adjust demand, but building-feasible power budgets may differ from accepted feeder-head offers. This study addresses a practical question: to what extent can the adjustable electricity consumption of buildings be translated into deliverable flexibility services while satisfying feeder-head operating requirements? To enable a fair comparison, we adopt the same baseline operating schedule, equipment conditions, and post-service recovery requirements for indoor temperature and battery state of charge (SOC). Flexibility is then evaluated under two settings: one considering only building-level constraints, and the other additionally accounting for feeder-head constraints. We first use a simplified network model with explicit security margins to determine a preliminary amount of flexibility that can be committed. The resulting schedule is then validated using a more detailed network simulation via Modelica. If network losses cause the actual response to deviate from the committed response, the electricity consumption of individual buildings is rescheduled. If the required response still cannot be achieved, the committed flexibility level is reduced. The experiments cover multiple service activation times, regulation directions, and service durations. For comparative purposes, we retain the initial optimization result as the reference estimate of the maximum potentially available flexibility, rather than interpreting the failure of a particular subsequent realization attempt as evidence that a larger flexibility level is inherently infeasible. The results demonstrated that 24.51\% of nonzero flexibility contracts were rejected due to feeder-head constraints, 67.04\% of contracts were accepted with some rescheduling and building redispatch, and only 8.09\% of contracts were accepted without any changes.

0.16

Adaptive Calibration of Day-Ahead Flexibility Reserve Requirements Under Distribution Shift

eess.SY ·2026-10-12 ·Napoleon Costilla-Enriquez, Yang Weng, Miguel A. Ortega-Vazquez
theory similarity 0.61
Abstract

The increasing integration of variable renewable generation introduces weather-driven variability and uncertainty into power-system operations. System operators manage the resulting deviations between day-ahead forecasts and real-time net load by scheduling upward and downward flexibility reserves. These requirements have traditionally been set using simple deterministic rules. Newer data-driven methods tailor reserves to forecasts and operating conditions. However, their reliability may deteriorate when conditions depart from the historical data. We address this limitation with a sequential framework that updates day-ahead reserve requirements as operating outcomes become available. Within this framework, Adaptive Conformal Inference targets the frequency of insufficient reserve, whereas Rolling Risk Control targets expected uncovered deviation, the mean residual beyond the scheduled reserve. We prove finite-horizon bounds on realized miscoverage and capped uncovered-deviation loss. We test the framework on real ERCOT data in a chronological deployment simulation that respects operational timing: outcomes from one day first affect the reserve schedule two days later. Training and validation use 2022--2023 data; the uninterrupted test covers 2024--2025. Coverage calibration achieves approximately 90% coverage, with upward and downward miscoverage near 5%. Risk calibration brings expected uncovered deviations close to their budgets while using 5.3% less reserve than the uncalibrated requirements. The framework thus produces adaptive reserve requirements that provably control the selected reliability metrics over finite horizons without assuming stationarity or exchangeability.

0.22

Comparative Evaluation of MILP, MPC, and Reinforcement Learning for Commercial Battery Dispatch Under Time-of-Use Tariffs

eess.SY ·2026-09-13 ·Hafiz Majid Hussain, Wajiha Samar, Lurian Klein, Pedro Nardelli
benchmark similarity 0.61
Abstract

Battery energy storage systems (BESS) paired with rooftop photovoltaics (PVs) can deliver measurable cost savings under time-of-use (TOU) electricity tariffs; however, the relative performance of model-based and model-free dispatch strategies remains insufficiently benchmarked on full-year, real-world commercial datasets. This paper presents a full-year (2023) comparative evaluation of three BESS dispatch approaches using data from a commercial PV installation operating under a TOU tariff. The examined strategies include: (i) a mixed-integer linear programming (MILP) formulation with perfect foresight, providing an oracle performance benchmark under the assumed model; (ii) a model predictive control (MPC) scheme based on a day-ahead persistence forecast, representing a low-complexity deployable approach; and (iii) a soft actor-critic (SAC) deep reinforcement learning agent trained under causal information constraints. The MILP benchmark achieves an annual cost reduction of 24.6\% relative to a no-storage baseline. The persistence-based MPC approach recovers 99.2\% of this benchmark using only prior-day data. In contrast, the evaluated SAC agent yields an annual cost higher than the no-storage baseline. This outcome is analyzed in the context of known challenges in reinforcement learning for energy systems, including limited observability and reward design. Overall, the results indicate that, for the studied dataset and tariff structure, persistence-based MPC captures nearly all achievable economic benefits under practical deployment constraints, whereas the considered RL configuration does not yield competitive performance under the same information limitations.

0.21