CS Paper Radar

Scarcity Pricing for State-of-Charge Management in Real-Time Markets Under Intra-Day Uncertainty

Shailesh Wasti, Aravind Retna Kumar, Sushant Varghese, Anthony Giacomoni, Parviz Alivand, Yujie Hu, Mort Webster

eess.SY ·submitted 2026-11-09 01:11 UTC · v1

Abstract

The growth in renewable resources will increase net load variability and forecast error. Energy storage resources can provide flexibility when ramp capability is limited and contribute to load leveling over the day. The challenge for system operators is how to balance these two functions in real time, when updated net load forecasts are available for a limited lookahead horizon. U.S. electricity markets are seeking ways to manage state-of-charge (SoC) within their energy markets to more efficiently utilize these resources. We propose a method to manage energy storage SoC in a real-time market by extending Hogan's (2013) scarcity pricing framework. A day-ahead SoC schedule is modified using existing multi-interval real-time unit commitment engines as net load forecasts change. To address 30-minute-ahead forecast errors, an updated 5-minute SoC target and a dynamically updated shortage price for violating the constraint are provided to each economic dispatch. We simulate PJM's energy markets for 365 days and demonstrate reliability improvements relative to a strategy that enforces the day-ahead schedule. We show cost reductions and improved price formation relative to a strategy that updates target quantities but uses an administratively chosen shortage penalty.

Closest papers

Nearest neighbours by meaning across the whole index.

State-of-Charge Targets for Storage Participation in Two-Settlement Markets: Reliability, Price, and Compensation Impacts

eess.SY ·2026-11-13 ·Yichen Li, Alexandre Moreira, Ruiwei Jiang, Miguel Heleno, Julie Mulvaney-Kemp
hot direction similarity 0.78
Abstract

As energy storage assumes a larger role in electricity systems, market operation must coordinate its use across time to support reliability during periods of system stress. Minimum state-of-charge (SOC) targets provide a means of preserving energy for these periods, but their design shapes reliability, operating efficiency, and storage compensation. This paper evaluates alternative SOC target designs in a California-based day-ahead and real-time electricity market model. The comparison examines targets based on day-ahead schedules or rolling centralized dispatch, enforced at the individual-resource or system level, across seasons, stress conditions, and participant information settings. The results show that retaining more energy does not necessarily reduce load shedding: targets that restrict discharge can limit storage support during shortages. Under critical summer conditions, individual targets derived from rolling centralized dispatch reduce weekly load shedding by approximately 83--84\% relative to operation without targets. Lower RT clearing costs and average prices can coexist with higher storage compensation, reflecting the role of day-ahead positions and real-time deviations in determining settlement outcomes. These findings highlight the importance of coordinating energy retention with timely discharge and network deliverability when designing SOC requirements for storage participation in electricity markets.

0.20

Minimizing Bid Cost Recovery for Energy Storage with Uniform Pricing

eess.SY ·2026-09-18 ·Yaxuan Yu, Jingguan Liu, Cong Chen
published similarity 0.71
Abstract · Accepted to the 65th IEEE Conference on Decision and Control (CDC 2026)

We study in-market uniform pricing and out-of-market bid cost recovery (BCR) payments in rolling-window dispatch for real-time power system operations with energy storage resources (ESRs). Due to intertemporal state-of-charge (SOC) constraints, ESR operations are temporally coupled, and existing in-market locational marginal pricing (LMP) may fail to compensate ESR's intertemporal opportunity costs, thereby triggering out-of-market BCR payments. We show that positive BCR is unavoidable when dispatched generators or ESRs have supply-side bids higher than the demand-side bid. We further identify an intertemporal coupling indicator associated with binding SOC constraints and demonstrate empirically that positive BCR arises only when this indicator is active, revealing that BCR is fundamentally driven by intertemporal coupling. In the simulation, we compare a BCR-minimizing uniform pricing scheme (UP-BCR) with existing real-time pricing methods under forecast uncertainty and show that UP-BCR substantially reduces BCR and demand payments relative to LMP while maintaining zero merchandising surplus in a copper-plate model.

0.24

Multi-Day Stochastic Dispatch for Power Systems With Long-Duration Storage Using Diffusion-Generated Weather Forecasts

eess.SY ·2026-10-12 ·Leonard Göke
benchmark similarity 0.71
Abstract

As power systems shift toward high shares of wind and solar, long-duration storage becomes pivotal for balancing multi-day deficits and surpluses of uncertain supply and demand. Current dispatch strategies for long-duration storage either assign a fixed value to stored energy or extend the modeled horizon using a single forecast. Stochastic system dispatch with a multi-day horizon for long-duration storage remains unexplored, and existing stochastic dispatch only considers day-ahead uncertainty or Markovian uncertainty beyond one week of perfect foresight. Therefore, we benchmark stochastic multi-day dispatch against deterministic alternatives in a rolling-horizon setup. To emulate probabilistic multi-day forecasts, we combine diffusion with a semi-Markov model of weather regimes and a logistic growth model for meteorological forecast errors. At high renewable shares, stochastic operation reduces thermal backup generation and consistently eliminates loss of load. The benefits decrease with smaller shares of renewables, less long-duration storage, or higher forecast skill. Overall, our results suggest that systems with high shares of variable renewables can substantially benefit from probabilistic multi-day forecasts and stochastic dispatch.

0.17

Decision-Focused Learning for Optimal Battery Scheduling Under Load and Photovoltaic Power Uncertainty in Microgrids

eess.SY ·2026-10-10 ·Marios Saleptsis, Antoine Lesage-Landry, Marco Mussetta, Sonia Leva
similarity 0.69
Abstract · 20 pages, 13 figures, submitted to Sustainable Energy, Grids and Networks

The increasing penetration of renewable energy sources in microgrids demands accurate day-ahead forecasting to support optimal battery energy storage system (BESS) scheduling. Yet the conventional predict-then-optimize paradigm trains forecasters on statistical accuracy metrics that are agnostic to the asymmetric and time-varying cost impacts of forecast errors. This work proposes a decision-focused learning (DFL) framework that trains gated recurrent unit forecasters for both load demand and photovoltaic generation directly on the downstream operational cost of a two-stage energy management system, where day-ahead BESS commitments are fixed prior to real-time balancing. Gradients are backpropagated from the real-time operational cost through both optimization stages to the forecaster weights via implicit differentiation, enabling the forecasters to internalize the penalty structure of the scheduling problem. The framework is validated on the MG2Lab experimental microgrid testbed at Politecnico di Milano across two operational scenarios of increasing grid constraint and eight forecasting configurations comprising single-source and combined-forecaster settings. Results illustrate that the DFL-trained pipeline reduces operational cost by 3.78% under normal grid conditions and by 30.60% under grid-constrained conditions relative to the accuracy- optimized baseline, while nearly eliminating load shedding events. Notably, the DFL forecasters exhibit higher statistical errors than their accuracy-trained counterparts yet achieve consistently lower operational costs, confirming that forecast accuracy and decision quality do not share a monotonic relationship in constrained microgrid scheduling.

0.12

Degradation-Aware Participation of Battery Storage in Frequency Regulation Markets

eess.SY math.OC ·2026-11-09 ·Anand Gokhale, Siddharth Bhela
hot direction similarity 0.68
Abstract · Extended version of IEEE PESGM submission

As data centers make the load on the power grid fluctuate faster, frequency regulation grows more valuable. Battery energy storage systems (BESSs) are well suited to provide frequency regulation, but providing this service speeds up aging, especially during operation at extreme state of charge (SoC). In the PJM interconnection, the grid operator supplies a regulation signal that a participating BESS is expected to follow, within a capacity that it must bid before the signal is known. Accordingly, we decompose the degradation-aware frequency regulation problem into a bidding layer and an operations layer. For bidding, we propose an adaptive strategy, assuming perfect tracking in which the bid depends on the SoC expected at the start of the bid period by means of choosing basepoints. For operation, the BESS further protects its battery by deliberately giving up a perfect performance score, to keep its SoC away from the extremes. On the PJM regulation signal and prices of 2023, adaptive bids lengthen the battery life by $31\%$ against bidding full capacity, for $2.2\%$ of the revenue. Giving up a perfect score in operation lengthens the battery life of constant bids by $10\%$ to $27\%$, at a change in revenue of at most $0.2\%$.

0.30

Impact of Wind-Solar-Battery Growth on Electricity Prices: Reserve Scarcity and Transmission Congestion

eess.SY ·2026-11-14 ·Haoxiang Wan, Ivan Castillo, Xingpeng Li
similarity 0.67
Abstract · 7 pages, 3 figures, 2 tables. Submitted to IEEE GECA 2027

This paper asks whether sequential wind, solar, and battery storage additions that eliminate unserved energy also remove modeled reserve scarcity and transmission congestion. Thirty-one cumulative portfolio states are evaluated on a modified IEEE 24-bus system for a constructed stressed day using a 24-hour day-ahead unit commitment model with network constraints, co-optimized energy and upward reserve, chronological battery storage, and an approximation of the Electric Reliability Council of Texas operating reserve demand curve. The thermal baseline has 106 MWh of unserved energy, whereas 450 MW of wind is sufficient to serve all demand. However, with 1,500 MW of wind, the hourly modeled reserve scarcity price still reaches \$5,000/MWh because wind output declines after the system peak. Adding 1,800 MW of solar reduces the load weighted daily average modeled reserve scarcity price from \$1,136.2/MWh to \$101.2/MWh and confines modeled reserve scarcity to three evening hours. Adding 250 MW/1,000 MWh of battery storage further lowers the average to \$4.3/MWh and reduces wind curtailment from 631 MWh to 306 MWh. Transmission congestion nevertheless remains: all residual wind curtailment occurs at bus 21, wind capture prices at buses 21 and 23 differ by \$31.8/MWh, and identical battery storage plants yield normalized net energy market revenues of \$201/(MW$\cdot$day) and \$121/(MW$\cdot$day) at buses 19 and 21, respectively. These results show that unserved energy, modeled reserve scarcity, and locational congestion effects measure distinct operating conditions and should be evaluated separately but interpreted together.

0.27

Joint Electricity Price and Load Forecasting for Data Center Battery Dispatch Using Polynomial Diffusion Models

eess.SY ·2026-11-05 ·Matthew Van Ham, Yiping Liu, Xiaozhe Wang
similarity 0.66
Abstract · 5 pages, 5 figures, Power & Energy Society (PES) General Meeting

The rapid growth of large-scale data centers (DCs) is increasing electricity demand, market volatility, and operating costs. Battery energy storage systems (BESSs) can mitigate these challenges by shifting electricity purchases from high-price to low-price periods. This paper proposes a real-time BESS dispatch framework using polynomial diffusion models (PDMs) to forecast both electricity prices and DC loads. Leveraging the closed-form conditional expectations of PDMs, the forecasts are integrated into a dynamic programming (DP) framework to minimize electricity procurement costs. Across the evaluated BESS configurations, the proposed approach achieves 2.63 times the cost savings of a rule-based (RB) strategy.

0.21

A Power-Trajectory Framework for Data Center Participation in Day-Ahead Markets

eess.SY ·2026-10-12 ·Menghan Zhang, Caisheng Wang
similarity 0.65
Abstract · 10 Pages, 7 Figures, 4 Tables

The rapid expansion of artificial intelligence (AI) is driving substantial growth in data center electricity demand. Interval-based energy blocks in day-ahead markets do not explicitly retain predictable intra-interval demand evolution, potentially creating mismatches with ramp-feasible generation trajectories and affecting settlement. This paper proposes a power-trajectory framework in which data centers declare predictable aggregate demand evolution through continuous demand-side power trajectories before market clearing. The declared trajectories are treated as exogenous inputs for constructing generation trajectories and the corresponding price trajectory. For feasible market-clearing outcomes, physical temporal consistency is established through continuous-time power balance and satisfaction of the modeled generation operating constraints, while economic temporal consistency is established by preserving the dispatch-price correspondence in energy settlement on a common temporal basis. Under the adopted settlement definitions, a trajectory-based settlement analysis separately quantifies the monetary magnitude of representation-induced power imbalances and the supply-side compensation that may remain under temporally consistent clearing and settlement. An illustrative 5-bus case demonstrates the elimination of representation-induced power imbalance and identifies the timing and physical sources of supply-side compensation. A modified IEEE RTS-GMLC case further illustrates these compensation effects across multiple generating units under workload-driven data center demand variations.

0.17