Abstract

As power systems shift toward high shares of wind and solar, long-duration storage becomes pivotal for balancing multi-day deficits and surpluses of uncertain supply and demand. Current dispatch strategies for long-duration storage either assign a fixed value to stored energy or extend the modeled horizon using a single forecast. Stochastic system dispatch with a multi-day horizon for long-duration storage remains unexplored, and existing stochastic dispatch only considers day-ahead uncertainty or Markovian uncertainty beyond one week of perfect foresight. Therefore, we benchmark stochastic multi-day dispatch against deterministic alternatives in a rolling-horizon setup. To emulate probabilistic multi-day forecasts, we combine diffusion with a semi-Markov model of weather regimes and a logistic growth model for meteorological forecast errors. At high renewable shares, stochastic operation reduces thermal backup generation and consistently eliminates loss of load. The benefits decrease with smaller shares of renewables, less long-duration storage, or higher forecast skill. Overall, our results suggest that systems with high shares of variable renewables can substantially benefit from probabilistic multi-day forecasts and stochastic dispatch.

Closest papers

Nearest neighbours by meaning across the whole index.

Scarcity Pricing for State-of-Charge Management in Real-Time Markets Under Intra-Day Uncertainty

eess.SY ·2026-11-09 ·Shailesh Wasti, Aravind Retna Kumar, Sushant Varghese, Anthony Giacomoni, Parviz Alivand +2 more
similarity 0.71
Abstract

The growth in renewable resources will increase net load variability and forecast error. Energy storage resources can provide flexibility when ramp capability is limited and contribute to load leveling over the day. The challenge for system operators is how to balance these two functions in real time, when updated net load forecasts are available for a limited lookahead horizon. U.S. electricity markets are seeking ways to manage state-of-charge (SoC) within their energy markets to more efficiently utilize these resources. We propose a method to manage energy storage SoC in a real-time market by extending Hogan's (2013) scarcity pricing framework. A day-ahead SoC schedule is modified using existing multi-interval real-time unit commitment engines as net load forecasts change. To address 30-minute-ahead forecast errors, an updated 5-minute SoC target and a dynamically updated shortage price for violating the constraint are provided to each economic dispatch. We simulate PJM's energy markets for 365 days and demonstrate reliability improvements relative to a strategy that enforces the day-ahead schedule. We show cost reductions and improved price formation relative to a strategy that updates target quantities but uses an administratively chosen shortage penalty.

0.30

Adaptive Calibration of Day-Ahead Flexibility Reserve Requirements Under Distribution Shift

eess.SY ·2026-10-12 ·Napoleon Costilla-Enriquez, Yang Weng, Miguel A. Ortega-Vazquez
theory similarity 0.64
Abstract

The increasing integration of variable renewable generation introduces weather-driven variability and uncertainty into power-system operations. System operators manage the resulting deviations between day-ahead forecasts and real-time net load by scheduling upward and downward flexibility reserves. These requirements have traditionally been set using simple deterministic rules. Newer data-driven methods tailor reserves to forecasts and operating conditions. However, their reliability may deteriorate when conditions depart from the historical data. We address this limitation with a sequential framework that updates day-ahead reserve requirements as operating outcomes become available. Within this framework, Adaptive Conformal Inference targets the frequency of insufficient reserve, whereas Rolling Risk Control targets expected uncovered deviation, the mean residual beyond the scheduled reserve. We prove finite-horizon bounds on realized miscoverage and capped uncovered-deviation loss. We test the framework on real ERCOT data in a chronological deployment simulation that respects operational timing: outcomes from one day first affect the reserve schedule two days later. Training and validation use 2022--2023 data; the uninterrupted test covers 2024--2025. Coverage calibration achieves approximately 90% coverage, with upward and downward miscoverage near 5%. Risk calibration brings expected uncovered deviations close to their budgets while using 5.3% less reserve than the uncalibrated requirements. The framework thus produces adaptive reserve requirements that provably control the selected reliability metrics over finite horizons without assuming stationarity or exchangeability.

0.22

Energy system device sizing under closed-loop operation with imperfect forecasts

eess.SY ·2026-11-12 ·Cara Koepele, Kevin Wallington, Georgios Mavromatidis, John Lygeros
similarity 0.64
Abstract · 8 pages, 7 figures, 2 tables. Submitted to the 2027 European Control Conference (ECC)

The value of renewable energy devices depends on their operation, which must adapt to weather and demand using limited, imperfect forecasts that update over time. Conventional energy systems planning practices assume unlimited foresight in a single-level formulation, potentially leading to long-term investment in suboptimal device sizes. Accounting for realistic operation corresponds to a bi-level problem: the upper level selects device sizes, while the lower level contains closed-loop operation under evolving forecasts. We solve this problem using backpropagation MPC (BP-MPC), a gradient-based method, with a deterministic MPC as the lower-level controller. Using forecast errors generated by a parameterized martingale model of forecast evolution, we investigate how forecast accuracy affects the benefits of operation-aware energy systems planning and the resulting device sizes. In a case study of an energy system comprising photovoltaics, a battery, a heat pump, and thermal storage with uncertain weather and energy demands, accounting for closed-loop operation yields higher average cost savings as forecast error increases. The resulting designs achieve these savings by progressively shifting investment from battery storage to solar generation and thermal storage, which buffers forecast mismatches.

0.37

Real-Time Control of Sustainable Data Centers: A Two-Layer Model Predictive Control Framework with Workload Flexibility and Heat Recovery

eess.SY ·2026-08-17 ·Wenyu Liu, Enea Figini, Mario Paolone
similarity 0.63
Abstract · 22 pages, 14 figures

This paper proposes a two-layer model predictive control (MPC) framework for the real-time operation of data centers integrated with on-site photovoltaic generation, battery energy storage, waste heat recovery, and district heating. The upper layer employs scenario-based stochastic optimization to jointly optimize intraday market participation, workload scheduling, and energy management under uncertainty. The lower layer adopts an adaptive tube-based MPC strategy that compensates short-term disturbances while tracking the dispatch references given by the upper layer. The framework further integrates multi-horizon forecasting to support real-time decision making. Microservice-based simulation studies under representative clear-sky and overcast operating conditions demonstrate that the proposed framework accurately tracks dispatch plans despite fast photovoltaic and workload fluctuations. Compared with single-layer control strategies, the adaptive lower-layer controller substantially reduces real-time dispatch deviations and the associated imbalance costs. In addition, the proposed framework naturally adapts to seasonal operating conditions and responds to carbon-aware operating signals, offering a practical approach for economically efficient, sustainable, and grid-supportive operation of future data centers.

0.29

Compound Climate Risk-Aware Electricity Dispatch: Trajectory-Based Modeling for Power System Resilience

eess.SY ·2026-10-29 ·Feiyu Cai, Jing Qiu, Chenxi Zhang, Yi Yang, Yuechuan Tao +1 more
similarity 0.62
Abstract · 10 pages, 8 figures

In recent decades, emerging compound hazards in a changing climate have increasingly threatened power system resilience and posed new challenges to electricity dispatch. Conventional Value-at-Risk (VaR)-based risk-aware dispatch provides a tractable means of managing stochastic net demand deviations caused by distribution feeder outages. However, when applied to temporally compounding events such as tropical cyclone (TC)--blackout--heatwave, conventional net demand risk formulations may assign similar risk levels to a brief outage and an outage with the same instantaneous net demand impact that persists into a subsequent hazard, despite their different requirements for sustained operational flexibility. Moreover, directly incorporating compound risk into electricity dispatch models faces a structural mismatch: the risk is defined by the joint distribution of feeder restoration and subsequent hazards over exponentially many joint states, whereas dispatch models require risk formulations that are tractable in the scheduling decisions. To address these issues, this paper proposes a compound climate risk-aware dispatch framework with a trajectory-based compound risk model, which defines the loss on operating deviations determined by entire feeder connection trajectories, parameterized by uncertain restoration times and coupled with subsequent hazards. Analytical moment-generating functions and equivalent exponential-cone reformulations provide a compact representation of the resulting risk constraints, preserving the relevant dependencies without explicit joint-state enumeration. By leveraging a physics-based spatiotemporal TC--blackout--heatwave hazard model, case studies demonstrate the effectiveness of the proposed method with real-world time-series power outage data from Puerto Rico, including data collected during Hurricane Fiona in 2022.

0.34

Risk Assessment of Fair Multi-Period Dynamic Operating Envelopes under Uncertainty

eess.SY cs.CE ·2026-10-30 ·Pedro Salomão Quessongo, Daniel Gebbran, Wilhiam de Carvalho, Clodomiro Unsihuay-Vila
published similarity 0.62
Abstract

Dynamic operating envelopes (DOEs) can allocate time-varying export capacity to distributed energy resources (DERs), and while they are not intended to make operations immune to voltage violations, they should guide operations to mostly remain inside expected values under changing regimes and residual forecast errors. However, although recent literature proposed many different techniques for implementing DOEs, there is sparse discussion of analyzing and quantifying the risk of using more or less conservative DOEs under uncertain operating regimes. Having this gap in mind, this paper develops a risk-oriented extension of a previously established fair distributed multi-period optimal power flow (OPF) framework, where fair or technical DOEs are fixed as first-stage decisions and the OPF leverages battery energy storage and renewable curtailment as recourse under regime uncertainties. An independent nonlinear AC power flow then computes a resulting ensemble, which is summarized by (i) voltage-violation probability, severity, and a persistence metric for consecutive out-of-band hours, (ii) curtailment and Jain and Gini indices, and (iii) model deviations. Different probability situations are assessed, ranging from uniform, sunny-heavy, night-peak-heavy, and adversarial, which separate the envelope design from the assumed operating distribution. An optional outer loop allows for fine-tuning a fairness--efficiency parameter under explicit violation and persistence budgets. The combination of the outer loop and the overall framework, which quantifies how often and how severely operating limits are exceeded, creates an auditable methodology mixing equitable export allocation, distributed recourse, and AC risk assessment for active distribution network operators, and this framework is assessed using up to 1000 Monte Carlo scenarios per mixture and DOE design.

0.35

Building Seasonal Highways for Residential Energy Hubs: Sizing, planning and operating thermal energy storage

eess.SY math.OC ·2026-10-01 ·Dario Slaifstein, Mohammad Khosravi, Gautham Ram Chandra Mouli, Laura Ramirez-Elizondo, Pavol Bauer
similarity 0.62
Abstract

The operation of residential energy hubs with multiple energy carriers (electricity, heat, mobility) poses a significant challenge due to the energy storage differences in time-constants, round-trip efficiencies and self-discharge rates. Usually, thermal storage exhibits flexibility in yearly planning optimizations or long-term scenarios. However, as optimization horizons shrink (1-48hs) so does their supplied value due to the lower round-trip efficiencies. To avoid this early depletion during operation this paper proposes a data-driven highway to steer the short-term daily control towards long-term optimality. The proposed methodology also presents how to optimally size the thermal storage and avoid yearly simulations and how all of this is related to nonlinearities in the daily operation. The presented framework links seasonal and daily optimizations through dynamic terminal sets and value functions. The seasonally-aware nonlinear economic model predictive controller achieves the most balanced performance, with the second best mean grid cost of all MPCs at -\texteuro 209. It also achieves better battery degradation control than its linear counterparts (between 26-34%) and the best thermal comfort of the nonlinear benchmarks. Nevertheless, the data-driven seasonal highway restrains the ability to control battery degradation and slightly increases computational time.

0.14

Decision-Focused Learning for Optimal Battery Scheduling Under Load and Photovoltaic Power Uncertainty in Microgrids

eess.SY ·2026-10-10 ·Marios Saleptsis, Antoine Lesage-Landry, Marco Mussetta, Sonia Leva
similarity 0.62
Abstract · 20 pages, 13 figures, submitted to Sustainable Energy, Grids and Networks

The increasing penetration of renewable energy sources in microgrids demands accurate day-ahead forecasting to support optimal battery energy storage system (BESS) scheduling. Yet the conventional predict-then-optimize paradigm trains forecasters on statistical accuracy metrics that are agnostic to the asymmetric and time-varying cost impacts of forecast errors. This work proposes a decision-focused learning (DFL) framework that trains gated recurrent unit forecasters for both load demand and photovoltaic generation directly on the downstream operational cost of a two-stage energy management system, where day-ahead BESS commitments are fixed prior to real-time balancing. Gradients are backpropagated from the real-time operational cost through both optimization stages to the forecaster weights via implicit differentiation, enabling the forecasters to internalize the penalty structure of the scheduling problem. The framework is validated on the MG2Lab experimental microgrid testbed at Politecnico di Milano across two operational scenarios of increasing grid constraint and eight forecasting configurations comprising single-source and combined-forecaster settings. Results illustrate that the DFL-trained pipeline reduces operational cost by 3.78% under normal grid conditions and by 30.60% under grid-constrained conditions relative to the accuracy- optimized baseline, while nearly eliminating load shedding events. Notably, the DFL forecasters exhibit higher statistical errors than their accuracy-trained counterparts yet achieve consistently lower operational costs, confirming that forecast accuracy and decision quality do not share a monotonic relationship in constrained microgrid scheduling.

0.12