CS Paper Radar

Energy system device sizing under closed-loop operation with imperfect forecasts

Cara Koepele, Kevin Wallington, Georgios Mavromatidis, John Lygeros

eess.SY ·submitted 2026-11-12 12:16 UTC · v1

Abstract

The value of renewable energy devices depends on their operation, which must adapt to weather and demand using limited, imperfect forecasts that update over time. Conventional energy systems planning practices assume unlimited foresight in a single-level formulation, potentially leading to long-term investment in suboptimal device sizes. Accounting for realistic operation corresponds to a bi-level problem: the upper level selects device sizes, while the lower level contains closed-loop operation under evolving forecasts. We solve this problem using backpropagation MPC (BP-MPC), a gradient-based method, with a deterministic MPC as the lower-level controller. Using forecast errors generated by a parameterized martingale model of forecast evolution, we investigate how forecast accuracy affects the benefits of operation-aware energy systems planning and the resulting device sizes. In a case study of an energy system comprising photovoltaics, a battery, a heat pump, and thermal storage with uncertain weather and energy demands, accounting for closed-loop operation yields higher average cost savings as forecast error increases. The resulting designs achieve these savings by progressively shifting investment from battery storage to solar generation and thermal storage, which buffers forecast mismatches.

Comment
8 pages, 7 figures, 2 tables. Submitted to the 2027 European Control Conference (ECC)

Closest papers

Nearest neighbours by meaning across the whole index.

Decision-Focused Learning for Optimal Battery Scheduling Under Load and Photovoltaic Power Uncertainty in Microgrids

eess.SY ·2026-10-10 ·Marios Saleptsis, Antoine Lesage-Landry, Marco Mussetta, Sonia Leva
similarity 0.68
Abstract · 20 pages, 13 figures, submitted to Sustainable Energy, Grids and Networks

The increasing penetration of renewable energy sources in microgrids demands accurate day-ahead forecasting to support optimal battery energy storage system (BESS) scheduling. Yet the conventional predict-then-optimize paradigm trains forecasters on statistical accuracy metrics that are agnostic to the asymmetric and time-varying cost impacts of forecast errors. This work proposes a decision-focused learning (DFL) framework that trains gated recurrent unit forecasters for both load demand and photovoltaic generation directly on the downstream operational cost of a two-stage energy management system, where day-ahead BESS commitments are fixed prior to real-time balancing. Gradients are backpropagated from the real-time operational cost through both optimization stages to the forecaster weights via implicit differentiation, enabling the forecasters to internalize the penalty structure of the scheduling problem. The framework is validated on the MG2Lab experimental microgrid testbed at Politecnico di Milano across two operational scenarios of increasing grid constraint and eight forecasting configurations comprising single-source and combined-forecaster settings. Results illustrate that the DFL-trained pipeline reduces operational cost by 3.78% under normal grid conditions and by 30.60% under grid-constrained conditions relative to the accuracy- optimized baseline, while nearly eliminating load shedding events. Notably, the DFL forecasters exhibit higher statistical errors than their accuracy-trained counterparts yet achieve consistently lower operational costs, confirming that forecast accuracy and decision quality do not share a monotonic relationship in constrained microgrid scheduling.

0.12

The Impact of PV Generation Forecast and Multi-Objective Control Policy on Optimal Operation of Grid Connected PV-BESS Microgrid

eess.SY ·2026-08-26 ·Berhane Darsene Dimd, Steve Voller, Ole-Morten Midtgård
similarity 0.68
Abstract

The variability of photovoltaic (PV) generation poses significant challenges to the reliable and efficient operation of grid-connected microgrids. Accurate PV output power forecasting and efficient energy scheduling strategies are essential not only for optimizing PV system operation but also for improving the overall performance and reliability of the system. This study proposes a long short-term memory (LSTM)-based PV power forecasting model integrated with a multi-objective scheduling framework for a grid-connected PV-battery energy storage system (BESS). The proposed approach enables detailed performance monitoring and assessment by quantifying how PV forecast accuracy influences key operational metrics, including PV self-consumption ratio, grid energy cost, grid injection, and battery utilization. Three forecasting scenarios (perfect forecast, persistence model, and LSTM-based forecast) are compared to evaluate their impact on system performance and operational reliability. Results show that the LSTM-based forecast reduces root mean squared error (RMSE) by 6% compared with the persistence model, increases the PV self-consumption ratio from 78.1% to 84.5%, and reduces grid injections by 82%. The analysis also highlights trade-offs, as higher battery throughput associated with improved performance may contribute to accelerated aging. These findings demonstrate the importance of accurate PV forecasting in improving system performance and ensuring reliable operation. Future work will focus on probabilistic forecasting to properly quantify uncertainties, incorporate load prediction, and develop smart control strategies that allow grid-support functionalities from the PV side.

0.32

Comparative Evaluation of MILP, MPC, and Reinforcement Learning for Commercial Battery Dispatch Under Time-of-Use Tariffs

eess.SY ·2026-09-13 ·Hafiz Majid Hussain, Wajiha Samar, Lurian Klein, Pedro Nardelli
benchmark similarity 0.68
Abstract

Battery energy storage systems (BESS) paired with rooftop photovoltaics (PVs) can deliver measurable cost savings under time-of-use (TOU) electricity tariffs; however, the relative performance of model-based and model-free dispatch strategies remains insufficiently benchmarked on full-year, real-world commercial datasets. This paper presents a full-year (2023) comparative evaluation of three BESS dispatch approaches using data from a commercial PV installation operating under a TOU tariff. The examined strategies include: (i) a mixed-integer linear programming (MILP) formulation with perfect foresight, providing an oracle performance benchmark under the assumed model; (ii) a model predictive control (MPC) scheme based on a day-ahead persistence forecast, representing a low-complexity deployable approach; and (iii) a soft actor-critic (SAC) deep reinforcement learning agent trained under causal information constraints. The MILP benchmark achieves an annual cost reduction of 24.6\% relative to a no-storage baseline. The persistence-based MPC approach recovers 99.2\% of this benchmark using only prior-day data. In contrast, the evaluated SAC agent yields an annual cost higher than the no-storage baseline. This outcome is analyzed in the context of known challenges in reinforcement learning for energy systems, including limited observability and reward design. Overall, the results indicate that, for the studied dataset and tariff structure, persistence-based MPC captures nearly all achievable economic benefits under practical deployment constraints, whereas the considered RL configuration does not yield competitive performance under the same information limitations.

0.21

Building Seasonal Highways for Residential Energy Hubs: Sizing, planning and operating thermal energy storage

eess.SY math.OC ·2026-10-01 ·Dario Slaifstein, Mohammad Khosravi, Gautham Ram Chandra Mouli, Laura Ramirez-Elizondo, Pavol Bauer
similarity 0.66
Abstract

The operation of residential energy hubs with multiple energy carriers (electricity, heat, mobility) poses a significant challenge due to the energy storage differences in time-constants, round-trip efficiencies and self-discharge rates. Usually, thermal storage exhibits flexibility in yearly planning optimizations or long-term scenarios. However, as optimization horizons shrink (1-48hs) so does their supplied value due to the lower round-trip efficiencies. To avoid this early depletion during operation this paper proposes a data-driven highway to steer the short-term daily control towards long-term optimality. The proposed methodology also presents how to optimally size the thermal storage and avoid yearly simulations and how all of this is related to nonlinearities in the daily operation. The presented framework links seasonal and daily optimizations through dynamic terminal sets and value functions. The seasonally-aware nonlinear economic model predictive controller achieves the most balanced performance, with the second best mean grid cost of all MPCs at -\texteuro 209. It also achieves better battery degradation control than its linear counterparts (between 26-34%) and the best thermal comfort of the nonlinear benchmarks. Nevertheless, the data-driven seasonal highway restrains the ability to control battery degradation and slightly increases computational time.

0.14

Battery Energy Storage Sizing in PV Ramp-Rate Smoothing using Constraint-Aware Reinforcement Learning-Based Controller

eess.SY ·2026-11-13 ·Arash Omidi, Tanmay Mishra, Mads R. Almassalkhi
benchmark similarity 0.65
Abstract

This paper presents a constraint-aware reinforcement learning (CARL) controller for battery energy storage system (BESS) sizing and photovoltaic (PV) ramp-rate smoothing. Rapid PV power fluctuations caused by cloud transitions can introduce operational and stability challenges in power systems. To mitigate these impacts, grid codes impose ramp-rate limits (RRL) on PV power injected to the grid. BESSs can support such grid codes by absorbing or supplying power during rapid variations. However, the extent to which BESSs can reduce PV-induced variability depends on (i) the BESS power and energy capacities; and (ii) the adopted controller. Thus, BESS sizing and controller design are coupled. Conventional moving-average control can increase battery usage due to filter-induced lag, while ramp-rate control is reactive and does not account for the long-term impact of actions on battery state of charge and future ramp events. Optimization-based methods can reduce BESS requirements by anticipating future PV variations, but their performance depends on accurate PV forecasts. To address these limitations, the CARL controller learns a causal state-feedback policy from historical PV data without requiring forecasts during deployment. Ramp-rate, converter-power, and state-of-charge constraints are incorporated into a causal feasibility interval that guarantees feasible actions by definition. A full-horizon input-convex neural network (ICNN)-based optimization is developed as a noncausal benchmark for the minimum achievable BESS requirements. Evaluation using three real-world PV datasets shows that, at a 10\%/min ramp-rate limit, CARL reduces peak BESS power by 8.7--10.4\% and energy capacity by 47.5--62.6\% relative to conventional ramp-rate control while maintaining the grid-codes compliance.

0.26

Multi-Day Stochastic Dispatch for Power Systems With Long-Duration Storage Using Diffusion-Generated Weather Forecasts

eess.SY ·2026-10-12 ·Leonard Göke
benchmark similarity 0.64
Abstract

As power systems shift toward high shares of wind and solar, long-duration storage becomes pivotal for balancing multi-day deficits and surpluses of uncertain supply and demand. Current dispatch strategies for long-duration storage either assign a fixed value to stored energy or extend the modeled horizon using a single forecast. Stochastic system dispatch with a multi-day horizon for long-duration storage remains unexplored, and existing stochastic dispatch only considers day-ahead uncertainty or Markovian uncertainty beyond one week of perfect foresight. Therefore, we benchmark stochastic multi-day dispatch against deterministic alternatives in a rolling-horizon setup. To emulate probabilistic multi-day forecasts, we combine diffusion with a semi-Markov model of weather regimes and a logistic growth model for meteorological forecast errors. At high renewable shares, stochastic operation reduces thermal backup generation and consistently eliminates loss of load. The benefits decrease with smaller shares of renewables, less long-duration storage, or higher forecast skill. Overall, our results suggest that systems with high shares of variable renewables can substantially benefit from probabilistic multi-day forecasts and stochastic dispatch.

0.17

Cost-Aware Reinforcement Learning with Action Masking and Projection for Battery Energy Storage Dispatch under Suppressed-Spread Market Shifts

cs.LG cs.AIeess.SY ·2026-09-20 ·Kuanlin Chen, Chen-Wei Kuo, Cheng-En Ou
published similarity 0.63
Abstract · Accepted for publication at IEEE IECON 2026. 6 pages, 3 figures, 3 tables

Battery energy storage system (BESS) dispatch must preserve operational feasibility while declining price spreads reduce the margin available to pay for cycling. We study a proximal policy optimization (PPO) controller whose pre-selection physical action mask and emergency projection are separated from a causal, forecast-informed economic advisory. All forecast-dependent methods receive the same causal 24-step forecast and grid-side settlement. Across five PPO seeds, advice-on net profit is 30.59 and 18.04 USD per 336-hour T1 and T2 window, versus 36.77 and 22.94 USD for proxy-cost MPC; PPO remains below this reference in both periods. Advice raises T2 profit from 16.45 to 18.04 USD while reducing throughput, but is immaterial in T1. On disjoint weekly blocks, PPO is stable under daily, weekly, and blended seasonal forecasts, weakens under persistence, and remains below proxy-cost MPC. Paired diagnostics localize changes to the observed 5-10 USD/MWh regime with mixed SoC-dependent effects. An M0-M6 ablation shows that mask removal sends thousands of infeasible requests to projection, while removing both physical layers exposes ramp violations. The evidence separates economic screening from feasibility enforcement without claiming formal safety, lifecycle-optimal aging, or RL dominance.

0.28

Real-Time Control of Sustainable Data Centers: A Two-Layer Model Predictive Control Framework with Workload Flexibility and Heat Recovery

eess.SY ·2026-08-17 ·Wenyu Liu, Enea Figini, Mario Paolone
similarity 0.63
Abstract · 22 pages, 14 figures

This paper proposes a two-layer model predictive control (MPC) framework for the real-time operation of data centers integrated with on-site photovoltaic generation, battery energy storage, waste heat recovery, and district heating. The upper layer employs scenario-based stochastic optimization to jointly optimize intraday market participation, workload scheduling, and energy management under uncertainty. The lower layer adopts an adaptive tube-based MPC strategy that compensates short-term disturbances while tracking the dispatch references given by the upper layer. The framework further integrates multi-horizon forecasting to support real-time decision making. Microservice-based simulation studies under representative clear-sky and overcast operating conditions demonstrate that the proposed framework accurately tracks dispatch plans despite fast photovoltaic and workload fluctuations. Compared with single-layer control strategies, the adaptive lower-layer controller substantially reduces real-time dispatch deviations and the associated imbalance costs. In addition, the proposed framework naturally adapts to seasonal operating conditions and responds to carbon-aware operating signals, offering a practical approach for economically efficient, sustainable, and grid-supportive operation of future data centers.

0.29