CS Paper Radar

Risk Assessment of Fair Multi-Period Dynamic Operating Envelopes under Uncertainty

Pedro Salomão Quessongo, Daniel Gebbran, Wilhiam de Carvalho, Clodomiro Unsihuay-Vila

eess.SY cs.CE ·submitted 2026-10-30 16:50 UTC · v1
published

Abstract

Dynamic operating envelopes (DOEs) can allocate time-varying export capacity to distributed energy resources (DERs), and while they are not intended to make operations immune to voltage violations, they should guide operations to mostly remain inside expected values under changing regimes and residual forecast errors. However, although recent literature proposed many different techniques for implementing DOEs, there is sparse discussion of analyzing and quantifying the risk of using more or less conservative DOEs under uncertain operating regimes. Having this gap in mind, this paper develops a risk-oriented extension of a previously established fair distributed multi-period optimal power flow (OPF) framework, where fair or technical DOEs are fixed as first-stage decisions and the OPF leverages battery energy storage and renewable curtailment as recourse under regime uncertainties. An independent nonlinear AC power flow then computes a resulting ensemble, which is summarized by (i) voltage-violation probability, severity, and a persistence metric for consecutive out-of-band hours, (ii) curtailment and Jain and Gini indices, and (iii) model deviations. Different probability situations are assessed, ranging from uniform, sunny-heavy, night-peak-heavy, and adversarial, which separate the envelope design from the assumed operating distribution. An optional outer loop allows for fine-tuning a fairness--efficiency parameter under explicit violation and persistence budgets. The combination of the outer loop and the overall framework, which quantifies how often and how severely operating limits are exceeded, creates an auditable methodology mixing equitable export allocation, distributed recourse, and AC risk assessment for active distribution network operators, and this framework is assessed using up to 1000 Monte Carlo scenarios per mixture and DOE design.

Journal ref
ISGT Asia 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Fair Dynamic Operating Envelopes using Distributed Multi-Period Optimal Power Flow and Jain Index for Active Distribution Networks

eess.SY cs.CE ·2026-08-24 ·Pedro Salomão Quessongo, Daniel Gebbran, Clodomiro Unsihuay-Vila
similarity 0.79
Abstract · 10 pages, submitted to CLAGTEE 2026 Conference

Dynamic operating envelopes (DOEs) are increasingly used to publish time-varying export limits that keep distribution networks within operational limits. Purely technical DOE allocation, however, can systematically privilege electrically favorable prosumers, while embedding fairness directly into a single-period optimal power flow (OPF) objective mixes network feasibility, equity and efficiency in a way that obscures the cost of fairness. This paper proposes a two-stage, multi-period framework that addresses both of these. Initially, a technical distributed OPF computes network-feasible export envelopes. The subsequent stage then applies a dynamic aggregate export budget and redistributes capacity through cumulative proportional fairness, limiting the additional curtailment by an admissible efficiency budget. The resulting fair DOEs are treated as first-stage decisions, while battery storage provides scenario-dependent recourse under demand and renewable uncertainty. The operational problem is solved by a calibrated regional alternating direction method of multipliers (ADMM) on a lossless LinDistFlow model and independently validated using AC power flow. We observe a trade-off between increases in curtailment \emph{versus} improvements on fairness, as expected, reaching Jain fairness indices close to unity. Results show that considering both storage (which alleviates curtailment impact) and multi-period fairness (which increases curtailment) is an interesting approach for modern DOE design, which in turn requires a multi-period, co-designed approach.

0.51

Reliability Value of Long-Duration Energy Storage against Extreme Events in High-Renewable Grids: A Full-Year AC-OPF Assessment

eess.SY ·2026-09-06 ·Jeongdong Kim, Jonggeol Na, Sungho Shin
similarity 0.69
Abstract · 39 pages, 12 figures

Long-duration energy storage (LDES) can mitigate prolonged renewable--load imbalances during Dunkelflaute events, but existing studies rely on zonal or linearized DC network models and inadequately analyze the operational feasibility of the grid across a wide range of full-year renewable, load, and contingency scenarios. To address this gap, this paper introduces a multi-period alternating-current optimal power flow (AC-OPF) formulation that captures the full nonlinear network physics and assesses the reliability value of LDES in high-renewable grids. To evaluate scarcity events spanning multiple days to weeks, full-year operation is modeled as an 8,760-h load-shedding minimization over scenarios sampled from a Gaussian copula model, fitted to 2010--2025 historical wind and bus-level load data, that represents both typical variability and tail events. On a synthetic 200-bus Illinois transmission network, a hybrid fleet of battery energy storage (BESS) and LDES with 50 MW total power reduces annual load shedding by 83.0% on average relative to the base network, versus 68.5% for short-duration BESS alone at equal power. To further account for unexpected line outages throughout the year, the formulation is extended to a multi-day security-constrained AC-OPF. Under N-1contingencies, no feasible operating solution is obtained for the base network, whereas the LDES-equipped network remains feasible in all considered cases, thereby saving the cost of additional generation and transmission capacity. During the contingency period, LDES acts as a backup power supply, requiring only 5.5% more generation on average than the no-contingency base case.

0.21

A Stochastic Mean-CVaR Framework for BESS Multi-Market Bidding Strategies

eess.SY ·2026-09-16 ·Younes Zahraoui, Jun Cao, Samir Kouro, Pedro Rodriguez Cortes
published similarity 0.65
Abstract · The paper has been accepted in IECON26 without any comments

Battery Energy Storage Systems (BESS) operators face significant challenges when participating in multiple electricity markets due to the complex coupling of price volatility and stochastic reserve activation. Traditional deterministic dispatch models neglect the "tail risks" associated with extreme market realizations, potentially leading to technical infeasibility or severe economic losses. This paper proposes a risk-aware stochastic optimization framework for the co-optimization of BESS participation in the Day-Ahead (DA) energy market and the manual Frequency Restoration Reserve (mFRR) market. The model explicitly captures multi-dimensional uncertainties by utilizing non-parametric Kernel Density Estimation (KDE) to generate joint price scenarios that preserve the empirical characteristics of European balancing markets. A two-stage stochastic programming approach is employed.To manage the financial exposure to high-impact price events, the Conditional Value-at-Risk (CVaR) metric is integrated into a Mean-CVaR objective function. This allows decision-makers to tune their risk-aversion levels and identify an efficient frontier between profitability and robustness. Simulation results demonstrate that the proposed joint CVaR approach significantly enhances revenue stability compared to deterministic benchmarks.

0.30

DOE-Constrained Distributed Battery Coordination in Unbalanced Distribution Networks

eess.SY ·2026-11-09 ·Bohang Fang, Anderson Toler, Lijun Ding, Wenqi Cui, Cong Chen
similarity 0.65
Abstract · 8 pages; substantially revised version with a new title, revised formulation and theoretical results, and updated numerical results

Dynamic operating envelopes (DOEs) provide injection and withdrawal limits for distributed energy resource scheduling while respecting network operational constraints. This paper develops a risk-aware DOE framework for distributed battery operation in unbalanced three-phase networks using a semidefinite program (SDP). We derive sufficient conditions for exactness of the SDP relaxation, ensuring that the recovered operating points corresponding to the DOE vertices satisfy all voltage and nodal power injection constraints of the original AC network model. The method computes hourly active-power DOEs under uncertain load conditions and incorporates them directly into a 24-hour battery operation problem. On a modified IEEE 13-bus feeder, empirical comparisons with unconstrained arbitrage and local Volt--VAR/Volt--Watt control show that DOE-constrained battery scheduling eliminates the observed out-of-sample voltage violations while retaining 94.6\% of the unconstrained arbitrage profit.

0.37

Harmonic-Constrained Hosting Capacity of Active Distribution Networks Using ESS Compensation and Certified Adaptive Decision-Tree Envelopes

eess.SY ·2026-11-16 ·Pengyu Ren, Wei Sun, Fei Teng, Gareth Harrison
similarity 0.65
Abstract

Active distribution networks increasingly rely on coordinated inverter-based resources to accommodate renewable generation, while harmonic limits constrain the capacity that can be connected. This paper proposes a harmonic optimal power flow (HOPF) method with active energy-storage-system (ESS) support. ESS charging, discharging and harmonic-current compensation are jointly scheduled under state-of-charge dynamics and a shared converter-current rating. An adaptive decision tree learns voltage-current partitions from OPF operating points. Within each leaf, an affine plane is fitted on an analytic grid and certified as a lower envelope. A disaggregated mixed-integer formulation embeds these envelopes in a second-order-cone-relaxed network model. Annual hourly data are assessed through daily capacity optimization, followed by componentwise capacity aggregation and chronological full-year feasibility validation. In the case study, the OPF reference of 65.572 MW exceeds the adopted harmonic bounds, whereas HOPF without harmonic support yields an annually validated capacity of 56.892 MW. With each generator capacity bounded by its OPF reference, the proposed method recovers the complete reference allocation. Coordinated energy dispatch and harmonic compensation thus recover generation capacity within the installed ESS converter ratings.

0.21

Zero-Sum Power Factor Games

eess.SY math.OC ·2026-08-20 ·Cameron Khanpour, Samuel Talkington, Mathieu Dahan, Daniel K. Molzahn
similarity 0.65
Abstract

Variable active power injections arising from device behavior or compromised dispatch complicate voltage regulation in electric power networks with distributed energy resources (DERs). An operator can limit the resulting voltage deviations by remotely selecting DER reactive power parameters before observing the active power injections. IEEE Standard 1547-2018 specifies constant power factor as one such control mode, coupling each device's reactive power to its realized active power. Using a linear voltage model, we formulate the operator's decision as a robust minimax problem in which the operator minimizes the largest feasible aggregate voltage deviation. We solve this problem by expressing the power factor decisions through continuous reactive to active power ratios and exactly decomposing the payoff according to the signs of the voltage deviations. When every feasible voltage residual remains on its initial side of nominal, the resulting ratios cancel each injection's contribution and yield a closed form minimax strategy. We identify realistic DER ratings for which this strategy applies and quantify the regulation capacity lost under restricted power factor ranges. Numerical tests check the cancellation computation, solve the complete minimax problem directly at a representative DER rating, and compare the linear voltage predictions with nonlinear AC power flow.

0.23

On the Concept of an Optimal Portfolio of Uncertain Flexible Loads

eess.SY ·2026-09-04 ·Julie Rousseau, Philipp Heer, Kristina Orehounig, Gabriela Hug
published similarity 0.63
Abstract · Accepted to the 2026 PowerUp conference

Flexible loads can enhance power system stability by providing reserves, but their limited energy capacity and uncertain availability distinguish them from conventional generators. To accommodate these characteristics, the Danish Transmission System Operator (TSO) recently introduced new reserve market rules that incorporate energy constraints and relax reliability requirements. In this context, the optimal reserve quantification becomes a joint chance-constrained reserve quantification problem, which is difficult to solve. In this paper, we derive two analytical reformulations of this problem: an exact one when a reserve direction dominates and an approximate one, otherwise. Furthermore, when flexible loads must collectively satisfy a reliability requirement, we introduce the concept of an optimal portfolio of flexible loads: adding loads with similar expected values but different stochastic behaviors to an existing portfolio may change the total portfolio's reserves. To support this idea, we theoretically study the marginal increase in reserves resulting from adding a load. Numerical results show that our analytical reformulations closely match the exact formulation, with a mean absolute error of 2.5%. Case studies further demonstrate the existence of optimal load groupings and our ability to predict the portfolio in which a load's marginal value is highest, leveraging our theoretical analysis.

0.43

Compound Climate Risk-Aware Electricity Dispatch: Trajectory-Based Modeling for Power System Resilience

eess.SY ·2026-10-29 ·Feiyu Cai, Jing Qiu, Chenxi Zhang, Yi Yang, Yuechuan Tao +1 more
similarity 0.62
Abstract · 10 pages, 8 figures

In recent decades, emerging compound hazards in a changing climate have increasingly threatened power system resilience and posed new challenges to electricity dispatch. Conventional Value-at-Risk (VaR)-based risk-aware dispatch provides a tractable means of managing stochastic net demand deviations caused by distribution feeder outages. However, when applied to temporally compounding events such as tropical cyclone (TC)--blackout--heatwave, conventional net demand risk formulations may assign similar risk levels to a brief outage and an outage with the same instantaneous net demand impact that persists into a subsequent hazard, despite their different requirements for sustained operational flexibility. Moreover, directly incorporating compound risk into electricity dispatch models faces a structural mismatch: the risk is defined by the joint distribution of feeder restoration and subsequent hazards over exponentially many joint states, whereas dispatch models require risk formulations that are tractable in the scheduling decisions. To address these issues, this paper proposes a compound climate risk-aware dispatch framework with a trajectory-based compound risk model, which defines the loss on operating deviations determined by entire feeder connection trajectories, parameterized by uncertain restoration times and coupled with subsequent hazards. Analytical moment-generating functions and equivalent exponential-cone reformulations provide a compact representation of the resulting risk constraints, preserving the relevant dependencies without explicit joint-state enumeration. By leveraging a physics-based spatiotemporal TC--blackout--heatwave hazard model, case studies demonstrate the effectiveness of the proposed method with real-world time-series power outage data from Puerto Rico, including data collected during Hurricane Fiona in 2022.

0.34