CS Paper Radar

Weekly top 10 · eess.IV

2026-W46 Nov 09 – Nov 15, 2026

Ranked from 3,982 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Do Underwater Image Quality Metrics Agree with Human Perception? A Benchmark with Human Choices, Simple Edits and Generative Drift

cs.CV eess.IV ·2026-11-13 ·Rishii Kumar Singh, Abhinav Rajput, Dinesh Kumar Vishwakarma
publishedbenchmarkcode/data
Abstract · Accepted at the 6th WVAQ Workshop, WACV 2027. 18 pages including appendix

Underwater image enhancement is challenging to evaluate due to the lack of clean reference images, so researchers rely on no-reference image quality assessment (NR-IQA) metrics. However, it remains unclear whether these metrics agree with human judgments. We evaluate 73 handcrafted underwater, learned underwater, vision-language and general-purpose metrics against human preferences on five references: four published opinion-score sets and a new paired-comparison study. For each metric, we measure how often it selects the same image as people when comparing versions of the same scene. We further test whether simple image edits and small adversarial perturbations raise metric scores above the enhancement people preferred, and whether scores decrease as repeated generative edits add noise. Our results show that no metric consistently matches human preferences. The best worst-case Cohen's kappa over the five references is only 0.23 (Q-Align), while two raters in our study agree with a median kappa of 0.41. The widely used UCIQE often favors edits that people reject. On a Nano Banana Pro replica chain that should leave the image unchanged, only 22 of 73 scores decrease at every checkpoint, while noise grows by 2.5 times. We also introduce TrustUIQA, a benchmark that combines the human references, our study choices, the edited, attacked and generated images, and the scores of every metric on every image. The code is available at https://github.com/TrustUIQA/TrustUIQA and TrustUIQA at https://huggingface.co/datasets/TrustUIQA/TrustUIQA.

0.54
2

Distribution Shift Detection in Remote Sensing Imagery using Machine Learning Models

cs.CV cs.LGeess.IVeess.SP ·2026-11-10 ·Abdullah Almansour, Ozan K. Tonguz
publishedcode/datahot direction
Abstract · Accepted as a short paper at the 4th Workshop on Computer Vision for Earth Observation (CV4EO), held in conjunction with WACV 2027

Remote sensing imagery acquired by Unmanned Aerial Vehicles (UAVs) supports wide range of applications; however, deploying machine learning (ML) models on resource-constrained aerial platforms introduces challenges beyond predictive accuracy, particularly when deployment data differ from the distributions observed during training. Such shifts are common in remote sensing due to geographic, sensor, seasonal, and other visual variations. A practical solution is to equip deployed models with mechanisms that detect emerging distribution shifts and support subsequent responsive actions. This paper presents an empirical case study of three open-source detection tools: (i) Alibi-Detect; (ii) NannyML; and (iii) PyTorch-OOD. Using cross-dataset remote-sensing shifts, we evaluate both detection effectiveness and computational latency of these tools. Our results reveal differences in detection behavior and processing cost across methods and implementations, highlighting trade-offs between detection capability and response-time. These findings motivate further work toward lightweight, and latency-aware monitoring mechanisms for resource-constrained systems.

0.46
3

Learned Regularization for Sparse-View CT: Accuracy, Lesion Detectability and Distribution Shift of a Plug-and-Play Prior against Tuned Total Variation

eess.IV cs.CVeess.SP ·2026-11-13 ·Mohammed Abo Oraig
code/data
Abstract · 62 pages, 22 figures, and 30 tables. Preprint (not peer-reviewed); also available on Zenodo: https://doi.org/10.5281/zenodo.24107061. Code a…

Learned image priors are often proposed to replace hand-crafted regularizers in sparse-view computed tomography (CT), yet they are usually judged by PSNR on data resembling their training set. We evaluate one noise-conditioned DnCNN denoiser used as a Plug-and-Play prior against filtered back-projection (FBP), Tikhonov and total-variation (TV) regularization, with every method tuned on validation data and all differences paired. On synthetic 28x28 digit images, the prior beats box-constrained TV by about 3.4 dB at moderate noise (sigma = 0.05, 20 angles), but the advantage shrinks at low noise and reverses under distribution shift: an MNIST-trained prior is 3.1 dB (Fashion-MNIST) and 4.3-4.6 dB (Shepp-Logan phantom) below TV, whereas a Fashion-MNIST-trained prior beats TV by 2.2 dB on Fashion-MNIST, consistent with prior mismatch rather than a failure of PnP itself. In a lesion-insertion test the prior detects lesions worse than TV in distribution despite its higher PSNR, and under mismatch it produces more lesion-like false blobs than box-constrained TV for seven of eight lesion types. On real LoDoPaB-CT slices (patient-disjoint split; 30, 60 and 120 angles; three dose levels; 40 test patients), the prior does not consistently outperform a well-tuned TV in PSNR (-0.93 to +0.33 dB) and has lower SSIM in eight of nine conditions. Its lesion-detection AUC is higher than this TV's in all nine conditions (significant in six) but never significantly higher than that of Hann-filtered FBP, which the PSNR-tuned TV falls below in detection in all nine conditions (seven significant). On non-anatomical phantoms its PSNR falls below TV in all six conditions. PSNR and lesion detectability thus rank the methods differently. Our conclusions concern one small denoiser, and the CT analysis was developed after seeing results, without pre-specified primary comparisons.

0.42
4

MRFoundry: Knowledge-guided agent loops for end-to-end MRI research

eess.IV cs.AI ·2026-11-09 ·Ke Wang, Atakan Topcu, Hossein Momeni, Molin Zhang
code/data
Abstract · 18 pages, including 6 pages of Supporting Information. Code: https://github.com/KeWang0622/MRFoundry

AI agents can write code, use scientific software, and revise computational workflows, opening new possibilities for MRI research. Effective assistance requires connecting acquisition physics, data conventions, specialized tools, and scientific validation. We present MRFoundry, an open-source, extensible package that connects MRI knowledge to agent actions and output checks. Project-local memory preserves decisions and evidence, while reviewed contributions allow researchers to improve shared guidance. Researcher-supervised examples demonstrate skill-guided sequence auditing and acquired-data reconstruction, connecting tool use, output checks, and documented decisions. Alongside MRFoundry, we introduce MRI Agent Bench to compare agents with and without the package across models and MRI task domains. Across 240 paired Core evaluations spanning 24 task types and ten models, all-checks-passed completion increased from 67.5% without MRFoundry to 78.3% with it. Across 134 Hard pairs, completion increased from 36.6% to 44.8%. MRFoundry makes MRI workflow expertise available as reusable guidance that researchers can inspect, adapt, and extend within existing agent and scientific software environments. MRFoundry is openly available at https://github.com/KeWang0622/MRFoundry.

0.41
5

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

eess.IV cs.CV ·2026-11-09 ·Aditya Seelaboyina, Irfan Khan
code/datahot direction
Abstract · 8 pages, 2 figures, 10 tables. Code: https://github.com/adityaseelaboyina/cxr-ensemble-vs-foundation-model

Ensembles of ImageNet-pretrained convolutional networks and Vision Transformers are a common way to improve multi-label chest X-ray classification. We ask whether such an ensemble is still worth its cost when a model pretrained on chest radiographs is available. On the official patient-disjoint split of NIH ChestX-ray14 (25,596 test images, 2,797 patients), we train five ImageNet-pretrained backbones and the EVA-X-S foundation model with validation-only model selection, compare five fusion rules, and estimate every difference with a patient-level paired bootstrap. EVA-X-S alone reached a test macro-AUROC of 0.828; the five-model ensemble reached 0.814 (difference -0.0136, 95% CI -0.0178 to -0.0098) at about 7.8 times the summed backbone latency and ten times the parameters. Averaging the five ImageNet models with EVA-X-S changed AUROC by -0.0056 (-0.0095 to -0.0021). With all five ImageNet backbones trained with the EVA-X-S recipe, their ensemble scored 0.817, still -0.0109 (-0.0142 to -0.0076) below EVA-X-S, and across three seeds EVA-X-S varied by at most 0.001 AUROC. Under the ImageNet models' recipe, however, EVA-X-S fell to 0.798. Our full-stacking configuration never outperformed calibrated averaging. In this setting, the tested ImageNet ensembles did not improve on a single chest X-ray foundation model fine-tuned with its own recipe.

0.38
6

Physics-Informed Generative Augmentation for Open-Set UAV Classification

eess.SP eess.IV ·2026-11-11 ·Michel Kulhandjian, Levon Aslanyan
published
Abstract · Accepted by ICT Express

Open-set recognition of unmanned aerial vehicles (UAVs) from passive 5G radar micro-Doppler signatures is challenging because unknown drone types cannot be anticipated at training time. We propose a physics-informed generative adversarial network (PI-GAN) that conditions spectrogram synthesis on rotor kinematics, forcing the classifier's feature space to encode physically meaningful structure. We compare PI-GAN augmentation against a vanilla conditional GAN (CGAN) and basic data augmentation across three held-out configurations with 1, 2, and 3 unknown classes. Vanilla CGAN augmentation collapses open-set clustering, reducing the adjusted Rand index (ARI) from 0.97 to 0.01, whereas PI-GAN preserves it at 0.97. In a controlled held-out sweep with two unknown classes, PI-GAN achieves an ARI of 0.92 compared to 0.07 for vanilla CGAN. The physics-informed features enable unsupervised separation of mechanically distinct unknown drones without retraining, demonstrating that physics-conditioned generation is the key enabler of open-set capability.

0.38
7

Mutual Colormap Dependence: How Recoloring Biomedical Images Changes Vision-Language Model Answers

eess.IV ·2026-11-11 ·Siddharth Vohra, Runmin Jiang, Min Xu
publishedcode/data
Abstract · Accepted to the FABRIC workshop at WACV 2027. 10 pages, 1 figure, 5 tables. Project page: https://siddvoh.com/mutual-colormap-dependence/

Vision-language models (VLMs) are being built to answer questions about biomedical images, yet they never see the measured intensities, only the colors that a colormap has assigned to them. For questions about image content, the colormap should not change the answer. We call the extent to which it does Mutual Colormap Dependence (MCD), the mutual information between the colormap and a model's answer, which is zero exactly when every colormap yields the same answer distribution. Because VLMs sample their answers, we compare recoloring with a control that uses the same number of calls to ask again about the unchanged gray image, so that ordinary resampling is not mistaken for an effect of the colormap. We test GPT-5.4, Gemini 3.1 Pro, Claude Sonnet 4.6, and Qwen3-VL-235B under six luminance-monotonic colormaps (gray, viridis, plasma, inferno, magma, and cividis) on 50 medical visual-question-answering items from 16 SLAKE images, 64 ChestX-ray14 chest radiographs, and 200 BBBC039 fluorescence-microscopy images for exact nucleus counting. Every prompt tells the model to ignore the colormap. Even so, with three answers per colormap on the chest radiographs, the answers of all four models depend on the colormap (all Holm-adjusted $p \leq 0.002$). For Claude, some colored map overturns the majority answer on 29 of the 64 radiographs, where resampling gray alone overturns about 4, and Qwen's accuracy falls from 0.54 under gray to between 0.32 and 0.41 under the colored maps, mostly because it abstains. With one answer per colormap, recoloring adds disagreement beyond repeated sampling in 5 of 12 model-panel cells under per-cell 95% intervals, and repeating the instruction to ignore color does not reliably reduce it. The colormap is therefore part of what a VLM sees, and it can change the answer.

0.37
8

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37
9

Ultrasound Elastography: Excitation Methods and Low-Cost Alternative

cs.CV eess.IV ·2026-11-11 ·Corin F. Otesteanu
published
Abstract

Ultrasound elastography (or elasticity imaging) is a method that characterizes the tissue mechanical properties with the purpose of aiding the diagnosis of certain pathologies. Many novel clinical applications use the assumption that these tissue properties are changed in the presence of pathological processes. Characterization of tissue mechanical properties is achieved by imaging the response of the tissue to an induced stress or excitation. A plethora of approaches have been used in the scientific community to induce excitation in tissue, which usually require additional tools or devices than are costly. Furthermore these are usually integrated in the imaging pipeline using additional software or hardware for control. An alternative that is simpler, faster to integrate (and low-cost) is proposed in this work, by using readily available smartphones as a source of mechanical excitation. The induced displacements are used to solve the elasticity inverse problem (IP) using a finite element method (FEM) approach. Preliminary elasticity reconstructions of a phantom that mimics tissue are similar to when using a dedicated actuator as means of inducing harmonic displacements, illustrating the feasibility of our low-cost ultrasound elasography approach.

0.36
10

Image Quality and the Reliability of Fabric-Density Measurement: Counting Threads from Smartphone Photos Through a Pick Glass

cs.CV eess.IV ·2026-11-09 ·Anoubhav Agarwaal
publishedbenchmark
Abstract · Accepted at the WVAQ workshop at WACV 2027

Thread density, the threads per inch along and across a woven fabric, is a basic specification that buyers check whenever fabric is sold. Without laboratory instruments, inspectors count it slowly, by eye, through a pick glass, a folding 10$\times$ magnifier with a one-inch window. A smartphone photo through that glass could make the check faster and leave a record. We judge such a photo by what it is used for, as in task-based image quality: it is good if the thread count from it is within $\pm$5% of the true count, a common tolerance in fabric specifications. We introduce PickGlass-TPI: 76 factory scenes of 44 fabric patches, each counted in an open annotation tool by a textile-trained annotator, whose counts are the reference. On it we benchmark frontier and open vision-language models, CNNs, counting specialists and a training-free spectral counter (PG-Lattice). No method agrees with the reference within the tolerance. The best methods are off by about a quarter: a small open model that we tuned only on synthetic images (Molmo2-4B, 25%) is level with the best frontier model, GPT-6.1-sol (27% when asked directly, 25% given four magnified close-ups of the window). Both err less than a non-expert annotator (37%), but only the tuned model also beats, on both error measures, a baseline that guesses each scene's density as the average of the others. PG-Lattice most often repeats its count within 5% across two photos of the same patch, but its misses, like GPT-6.1-sol's errors, are often a factor of two. Even the reference repeats a count across such re-shoots only to a median 9%, so one photo cannot yet be shown to meet $\pm$5%; the image quality that matters is reliability across re-shoots. Generic no-reference quality scores chosen before labeling do not rank PG-Lattice's error, and generative enhancement raises perceptual scores but does not reliably improve the count.

0.35