CS Paper Radar

Daily listing

2026-08-11 · eess.IV

10 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 8

Dual-Domain Cross-Modal Decoding for Clinical Text-Guided Medical Image Segmentation

cs.CV cs.AIeess.IV ·2026-08-11 ·Md Maklachur Rahman, Tracy Hammond
top venuecode/data
Abstract · Accepted at MICCAI 2026 (Main). Final version to appear in the MICCAI 2026 proceedings

Clinical text can narrow down what to segment, but recent text-guided designs emphasize spatial alignment while overlooking frequency content that governs texture and boundaries. We propose Dual-Domain Cross-Modal Decoding (DD-CMD) for clinical text-guided pulmonary infection segmentation, integrating two complementary forms of language guidance during decoding. In the spatial domain, Text-Guided Spatial Cross-Attention (TGSA) aligns multi-scale visual tokens with text semantics and updates features through gated residual fusion. In the frequency domain, Spectral-Text Adaptive Modulation (STAM) applies a 2D DCT to compute learnable band-energy statistics and predicts text-conditioned FiLM parameters to recalibrate decoder channels for frequency-aware decoding. DD-CMD embeds TGSA and STAM into a coarse-to-fine decoder (7x7 to 56x56) and restores full-resolution masks using a lightweight two-stage refinement module. Experiments on QaTa-COV19 and MosMedData+ show that DD-CMD achieves 91.46% Dice / 84.26% mIoU and 81.95% Dice / 69.42% mIoU, respectively, with average gains of +1.96 Dice and +2.67 mIoU over the strongest prior baselines. Code: https://github.com/maklachur/DD-CMD.

0.84

Geometry-Based Compression of Plenoptic Point Clouds

eess.IV cs.CVcs.MM ·2026-08-11 ·Davi R. Freitas, Gustavo L. Sandri, Ricardo L. de Queiroz
Abstract

Plenoptic point clouds (PPC) are novel data structures that represent the light from different viewing directions in order to provide a higher degree of realism to regular point clouds. This is achieved by associating each point to multiple colors instead of a single one. Here, we present a method to efficiently compress the attributes of a PPC, consisting of a Karhunen-Loève transform over the color attributes followed by multiple attribute coders with intra prediction capability. This compression scheme can be incorporated within the MPEG's geometry-based PCC (G-PCC) standard, using any of G-PCC's existing solutions for attribute coding. Compression performance assessment using PPCs of different spatial resolutions reveals competitive results in comparison to existing methods, such as RAHT-based or video-based PCC solutions. We believe our coder to be the new state of the art.

0.50

Uncertainty-Aware Compositional Localization and Placement Assessment of Catheters and Tubes in Chest X-Rays

eess.IV cs.CVcs.LG ·2026-08-11 ·Harshil Lodhiya
Abstract · 21 pages, 8 figures Included declaration for paper is under consideration at Pattern Recognition Letters

Assessing catheter and tube placement on chest X-rays is safety-critical yet tedious and error-prone. Current deep learning methods either classify placement globally -- losing track of which device is where -- or segment all devices into a single mask, making per-device assessment impossible when catheters overlap. We introduce UCompCXR, a compositional framework that detects local catheter fragments, associates them into device instances via graph-based clustering, fuses per-fragment tip predictions through precision-weighted Gaussian estimation, and classifies placement per device. On the RANZCR CLiP dataset (30,083 images, 5-fold patient-level CV with bootstrap CIs), UCompCXR detects 26% more devices than a strong multi-task baseline sharing the same MobileNetV3 backbone, with 75% fewer false positives and well-calibrated tip uncertainty (95% coverage = 0.948). The aggregate tip error rises -- but only because the model finds devices the baseline misses entirely, especially nasogastric tubes. On matched devices, catastrophic localization failures drop substantially. At 2.27M parameters in a single forward pass, the model is deployable on resource-constrained clinical hardware.

0.40

Physics-Informed Implicit Neural Representations for Improved Myocardial Perfusion MRI Quantification

eess.IV cs.AIcs.LG ·2026-08-11 ·Christos Tsepas, Chang Yan, Maximilian Fuetterer, Sebastian Kozerke, Cian M Scannell
publishedcode/data
Abstract · Accepted at the STACOM workshop at MICCAI, Strasbourg 2026

Quantifying myocardial perfusion from cardiac magnetic resonance (CMR) can be achieved by fitting tracer-kinetic models to the dynamic contrast-enhanced MR data. However, fitting the observed data with multi-compartment exchange models, which describe the evolution of the contrast agent in the tissue, to estimate perfusion parameters is a challenging inverse problem that is sensitive to noise and acquisition variability. Previously, physics-informed neural networks (PINNs) have been proposed as an alternative to conventional non-linear least squares fitting methods with promising results for quantitative perfusion CMR. In this work, we extend the previously proposed PINN framework with spatiotemporal implicit neural representations (INRs) to represent the MR signal as a continuous spatiotemporal function and to improve the accuracy, smoothness, and physical consistency of the PINN model. In realistic simulated CMR datasets, our proposed PINN with INRs demonstrates improved robustness and parameter estimation accuracy over the previously established methods. The code is available at https://github.com/q-cardIA/pinn-inr.

0.38

Hardware-Aware Deployment of Joint SAR Compression and Despeckling on FPGA

eess.IV cs.LG ·2026-08-11 ·Cédric Léonard, Francescopaolo Sica, Martin Schulz
code/data
Abstract · Submitted to IEEE Transactions on Geoscience and Remote Sensing (TGRS). 11 pages, 8 figures, 4 tables

Next-generation Synthetic Aperture Radar (SAR) missions will generate data far faster than they can downlink, making onboard data reduction essential for near-real-time Earth observation. Learned Image Compression (LIC) offers better rate-distortion performance than handcrafted codecs used operationally today, and recent work shows that simultaneously despeckling and compressing SAR imagery enables better representation capacity while unlocking higher compression rates. These methods, however, have yet to be confronted with the strict power, compute, and operational constraints of spaceborne systems. In this work, we bridge this gap by deploying a joint SAR Despeckling and Data Compression (DDC) framework on an embedded ZCU102 FPGA-based platform, introducing model adaptations that respect the accelerator's fixed-point arithmetic and limited set of supported operations. We evaluate four model topologies across precision levels and across CPU, GPU, and FPGA platforms, revealing several findings with direct design implications. We find that replacing conventional GDN activation functions with plain ReLU improves quality on SAR, suggesting that design principles established for compression of natural images do not necessarily transfer to SAR imagery. In addition, we demonstrate that residual blocks offer little representational benefit for ten times the compute, and show that the FPGA is the most energy-efficient of the platforms tested. Together, these results set a functioning edge deployment workflow and an evidence-based starting point for onboard SAR compression. The code is available at https://github.com/CedricLeon/SAR_DDC_FPGA.

0.32

Retrieval-Augmented Vision Foundation Models for Robust Leukemia Cell Classification across Multiple Microscopy Datasets

eess.IV cs.CVcs.LG ·2026-08-11 ·Carlos Zamora, Hiram Zuniga, Ulises Orozco-Rosas, Kenia Picos
published
Abstract · Accepted at SPIE Optics + Photonics 2026 for oral presentation. 23 pages, 12 figures, 9 tables

Leukemia cell image classification is challenged by real-world domain shifts from acquisition, staining, illumination, and site protocols, causing single-dataset models to generalize poorly in real clinical scenarios. This work presents a robust framework for leukemia classification across multiple heterogeneous datasets using a two-stage pipeline with a pretrained vision foundation model. Stage 1 performs binary classification (leukemia vs. non-leukemia) and is trained using 122,167 single-cell images. Stage 2 is conditionally applied to Stage 1 positives to perform subtype classification into Acute Lymphoblastic Leukemia (ALL) and Acute Myeloid Leukemia (AML), trained using 69,400 single-cell images. Labels are harmonized across five heterogeneous datasets to enable cross-dataset training, and performance is evaluated on a held-out dataset protocol to assess domain-shift generalization. Within this pipeline, three encoders are benchmarked (DinoBloom, pretrained on single-cell images; BiomedCLIP, pretrained on biomedical data; and CLIP as a general-purpose model) under linear probing, Low-Rank Adaptation (LoRA), and a Retrieval-Augmented Classification (RAC) module that retrieves the top-k most similar cell images to provide cytomorphological grounding. The objective is to quantify how much domain-specific pretraining contributes to performance under domain shift, and whether cost-effective adaptation and retrieval can be a viable alternative to expensive domain-specialized pretraining. The held-out protocol additionally serves as a diagnostic tool, revealing when classification performance is attributable to dataset-specific artifacts rather than to cytomorphological features.

0.28

Uncertainty-Aware and Explainable Ensemble Deep Learning Framework for Multi-Class Skin Lesion Classification

eess.IV cs.AIcs.CVcs.LG ·2026-08-11 ·Rofiqul Islam, Lilatul Ferdouse
Abstract · 5 pages, 3 figures, IEEE AIBThings 2026

Skin cancer diagnosis from dermoscopic images remains challenging due to high intra-class variability, inter-class similarity, class imbalance, and the limited interpretability of deep learning models. This paper proposes an uncertainty-aware and explainable deep learning framework for multi-class skin lesion classification. The framework combines a vision transformer model (MaxViT-Tiny) with CNN-based models (ConvNeXt-Tiny and EfficientNetV2-B0) through deep ensemble learning. Monte Carlo (MC) Dropout estimates predictive uncertainty and identifies unreliable predictions, while Grad-CAM++, an explainable AI (XAI) technique, provides visual explanations by highlighting lesion regions that influence model decisions. Evaluated on the HAM10000 dataset, the framework achieves 96% accuracy and 99% ROC-AUC under uncertainty-aware filtering (entropy < 1.0, confidence >= 0.7), with macro-average precision, recall, and F1-score of 94%, 95%, and 95%, respectively, and 96% weighted-average scores across all three metrics. The results demonstrate accurate, interpretable, and uncertainty-aware skin lesion classification for trustworthy computer-aided diagnosis.

0.07

A Comparison of Whole Slide Image Analysis and Diagnostic Field Selection in Pathology AI under Finite Resources

eess.IV q-bio.QM ·2026-08-11 ·Tatsuaki Tsuruyama
Abstract

An important question in pathology AI is how to allocate limited analytical resources between broad coverage of a whole slide image (WSI) and detailed analysis of selected regions. We compared a minimal WSI-AI model designed for broad search with Diagnostic Field Selection AI (DFS-AI), which uses a coarse overview to select diagnostically relevant fields for detailed analysis. Three minimal models introduced localization information, contextual discrimination, and spatial structure in sequence. In Model I, WSI-AI was favored when coarse localization was uninformative or costly. When coarse observation provided useful ranking information, DFS-AI was favored over an intermediate range of resources; WSI-AI again became preferable when resources allowed nearly complete fine observation. In Model II, background heterogeneity generated distractors. In a WSI control given the same local context as DFS-AI, most of the original DFS advantage was explained by local background correction, while coarse candidate selection provided a smaller additional benefit. In Model III, larger contiguous lesions were easier for WSI-AI to discover but more difficult to characterize completely with a finite budget for fine observation. The DFS advantage for complete characterization persisted when the comparator used the same field sized unit of fine analysis and when success was defined symmetrically as 100%, 90%, or 80% lesion unit coverage. Together, the models support a framework in which the preferred strategy changes with available resources and depends on the information available for selection, its acquisition cost, lesion structure, and the diagnostic endpoint. This framework clarifies when limited pathology AI resources should be devoted to broad WSI coverage and when they should be concentrated on selected Diagnostic Fields.

0.04

Systems & Networking 1

Media-over-Multipath-QUIC for Realtime Video Applications

cs.NI cs.ETcs.MMeess.IV ·2026-08-11 ·Tanya Shreedhar, Zuji Zhou, Nitinder Mohan, Fernando Kuipers
Abstract · In review

Multipath transports place a client's WiFi, cellular, and satellite networks under one connection, yet real-time video gains little from them. The scheduler that assigns packets to paths sees only bytes, so it cannot tell a keyframe that anchors a second of video from an enhancement frame whose loss costs one image. We show that the limiting factor is not a shortage of path diversity but the absence of a channel through which the application can name what the transport cannot see. Media over QUIC Transport (MoQT), already deployed on production CDNs, carries media as named Objects, and relays forward each Object's metadata without interpreting it. The knowledge the scheduler lacks therefore already flows through the subscriber's relay. We present MoMQ, a MoQT extension that turns this metadata into path decisions. Applications and relay operators install declarative rules at the edge relay that match Object metadata and express delivery preferences against labeled paths. The relay evaluates the rules mechanically, so it acts on video semantics while containing no video logic. On a live testbed spanning Starlink and WiFi, four rules cut P99.9 frame completion time from 384.7 ms under the best transport-only scheduler to 114.1 ms and reduce the required playback buffer by 61.5%. MoMQ is the only configuration that meets the 150 ms interactive latency target. Across relays in two countries and subscribers on two continents, the same rules apply unchanged and retain their advantage wherever the paths remain disjoint.

0.04

People & Society 1

Automatic Field-of-View Adjustment for a View-Expansive Microscope via LSTM-Based Gaze and Pipette Motion Interpretation

cs.HC cs.LGcs.ROeess.IV ·2026-08-11 ·Kenta Yokoe, Takuya Hara, Tadayoshi Aoyama
published
Abstract · This is the accepted version of an article published in IEEE Access 13, 182915-182923 (2025). DOI: 10.1109/ACCESS.2025.3624246. Open Access …

Intracytoplasmic sperm injection (ICSI) operators frequently adjust the field-of-view (FOV) during procedures, which interrupts workflow and increases procedure time. Conventional microscopes require manual objective lens switching and illumination adjustments to achieve different FOV sizes. We propose an AI-based automatic FOV adjustment method integrated with a view-expansive microscope. This microscope enables the simultaneous acquisition of a large FOV and high-resolution images using a single objective lens through multiview imaging with galvanometer mirrors and high-speed vision, thereby eliminating the need for physical lens exchanges. Our method utilizes a long short-term memory (LSTM) model to predict the appropriate FOV size based on real-time analysis of the pipette's position and velocity, combined with the operator's gaze position. The AI model is trained using ICSI procedure data from an expert with over five years of micromanipulation experience. Experimental evaluation with novice operators reveals that the proposed automatic FOV adjustment system significantly improves the ICSI procedure speed, reducing the average task completion time from 60.5 to 48.0 s (p < 0.001). The experiments also demonstrate that this improvement enables novice operators to achieve ICSI working speeds equivalent to those of expert operators.

0.62