CS Paper Radar

Daily listing

2026-08-28 · eess.IV

14 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 13

CheXtriev: Anatomy-Centered Representation for Case-Based Retrieval of Chest Radiographs

eess.IV cs.AIcs.CVcs.LG ·2026-08-28 ·Naren Akash, Arihanth Tadanki, Jayanthi Sivaswamy
top venuecode/data
Abstract · Accepted at the 27th International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI 2024)

We present CheXtriev, a graph-based, anatomy-aware framework for chest radiograph retrieval. Unlike prior methods focussed on global features, our method leverages graph transformers to extract informative features from specific anatomical regions. Furthermore, it captures spatial context and the interplay between anatomical location and findings. This contextualization, grounded in evidence-based anatomy, results in a richer anatomy-aware representation and leads to more accurate, effective and efficient retrieval, particularly for less prevalent findings. CheXtriv outperforms state-of-the-art global and local approaches by 18% to 26% in retrieval accuracy and 11% to 23% in ranking quality. The code is available at https://github.com/cvit-mip/chextriev.

0.77

Evidence-Driven Differential Diagnosis of Malignant Melanoma

eess.IV cs.AIcs.CVcs.LG ·2026-08-28 ·Naren Akash, Anirudh Kaushik, Jayanthi Sivaswamy
top venuecode/data
Abstract

We present a modular and multi-level framework for the differential diagnosis of malignant melanoma. Our framework integrates contextual information and evidence at the lesion, patient, and population levels, enabling decision-making at each level. We introduce an anatomic-site aware masked transformer, which effectively models the patient context by considering all lesions in a patient, which can be variable in count, and their site of incidence. Additionally, we incorporate patient metadata via learnable demographics embeddings to capture population statistics. Through extensive experiments, we explore the influence of specific information on the decision-making process and examine the tradeoff in metrics when considering different types of information. Validation results using the SIIM-ISIC 2020 dataset indicate including the lesion context with location and metadata improves specificity by 17.15% and 7.14%, respectively, while enhancing balanced accuracy. The code is available at https://github.com/narenakash/meldd.

0.69

SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation

eess.IV cs.CV ·2026-08-28 ·Niklas Schwarz, Jens Kleesiek, Moritz Rempe
publishedcode/data
Abstract · Accepted to Winter Conference for Applications in Computer Vision 2027, Orlando, Florida

Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression that lacks explicit correspondence constraints. We introduce SCoPE-Reg, combining dual-input state-space slice-volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and $μ$-RegPro, SCoPE-Reg yields mean target registration errors of $0.73$ mm and $2.27$ mm against $1.24$ mm and $2.63$ mm for the best-performing baseline, reduces peak error on CAMUS by 56% ($12.5\to5.5$ mm), and registers $100%$ and $80%$ of frames within $3$mm. On CAMUS at $128^2$ it retains the lowest error at increasing pose-perturbation magnitude. It holds $6.49$ M parameters independent of resolution, sustaining $51$ FPS at $512^2$. By coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, SCoPE-Reg becomes viable at native acquisition resolution during intervention, whereas previous methods had to compromise on accuracy, reliability or frame rate. Supplementary code: https://github.com/TIO-IKIM/SCoPE-Reg.

0.50

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

eess.IV cs.CV ·2026-08-28 ·Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten +3 more
published
Abstract · Accepted as a CaPTion workshop paper at MICCAI 2026

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

0.40

Generative Translation Priors: Bayesian Imaging with Cross-Modality Image Translation

eess.IV cs.CVcs.LG ·2026-08-28 ·Evan Bell, Jiaming Liu, Yifan Chen, Yu Sun
code/data
Abstract · 51 pages, 12 figures. Code is available at https://github.com/Hopkins-CIG/GTP

The ability to leverage images from co-available modalities to inform target-domain reconstruction is highly desirable in imaging algorithms. In this work, we introduce Generative Translation Priors (GTP)--a Bayesian framework that transforms diffusion-based image-to-image translation models into cross-modality image priors for ill-posed imaging inverse problems. GTP incorporates target-domain measurements through likelihood guidance, steering the translation process toward the desired posterior distribution. The framework is grounded in a theoretical analysis of the resulting posterior dynamics, which reveals an intrinsic bias introduced by likelihood guidance. We further characterize this bias and derive a ground-truth-free formulation for its estimation, enabling it to serve as a practical metric for assessing posterior sampling quality. Building on this analysis, we derive two discretized GTP algorithms based on gradient and proximal likelihood guidance, respectively. We validate GTP on computed tomography reconstruction with magnetic resonance side information, and on positron emission tomography reconstruction with computed tomography side information. Experiments demonstrate that GTP effectively incorporates complementary cross-modality information and achieves high-fidelity reconstruction even under severely undersampled measurements.

0.38

Lossy Event Compression: From Event Stream Distortion to Task Performance

cs.CV eess.IV ·2026-08-28 ·Zahra Rezaee, Catarina Brites, João Ascenso
published
Abstract

Event cameras generate asynchronous, sparse data streams with microsecond temporal resolution, but in moderate-to-high motion scenes they can produce as many as hundreds of millions of events per second, creating significant bandwidth and storage challenges. Lossy compression is therefore essential for practical deployment, yet existing event stream distortion metrics fail to reliably predict compression-induced degradation at the task level, forcing codec optimization to rely on expensive task-specific evaluations. To address this gap, this paper introduces two fundamentally different event compression pipelines: i) an aggregation-based pipeline that converts the event stream into polarity-based histogram frames for compression with the conventional image codec JPEG 2000, and ii) a frame-free point cloud-based pipeline that codes events natively as 3D points using the octree-based codec G-PCC. Both pipelines are then assessed within a unified task-driven evaluation framework that relates event stream distortion to downstream application performance across four representative tasks: i) video reconstruction, ii) object detection, iii) optical flow estimation, and a delay-sensitive task iv) asynchronous feature tracking under a reference-relative protocol. Building on this framework, five classification-based distortion metrics are applied to event compression for the first time, to the best of the authors' knowledge, and benchmarked against existing event stream metrics. Experimental results demonstrate that the proposed metrics reliably predict compression-induced task degradation across different coding frameworks. This demonstrates that event stream distortion assessment can be an efficient alternative to repeated task-specific evaluation, providing direct guidance for the development and optimization of future event data coding solutions.

0.35

Patch-Based Diffusion Reconstruction for Accelerated Cardiac Cine

eess.IV eess.SP ·2026-08-28 ·Xuan Lei, Philip Schniter, Juliet Varghese, Rizwan Ahmad
Abstract

Purpose: To develop and evaluate a diffusion-based reconstruction framework for highly accelerated 2D real-time (RT) cine cardiovascular magnetic resonance imaging (CMR). Methods: We trained an unconditional patch-based diffusion model and incorporated it into a reconstruction framework, termed CineDiff, using diffusion posterior sampling for data consistency. CineDiff was evaluated in four settings: (i) 30 retrospectively undersampled breath-held cine at 1.5T and 3T from healthy participants across multiple acceleration rates, (ii) 15 prospectively undersampled free-breathing RT cine at 1.5T and 3T from patients indicated for clinical CMR, and (iii) 10 prospectively undersampled mid-field (0.55T) free-breathing scans, including five from healthy subjects and five from porcine models. For retrospective undersampling, reconstruction quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), learned perceptual image patch similarity (LPIPS), and deep image structure and texture similarity (DISTS). For prospective undersampling, image quality was evaluated by blinded expert scoring on a 5-point Likert scale. Results: In retrospectively undersampled breath-held cine data, CineDiff achieved higher PSNR and SSIM and lower LPIPS and DISTS than the comparison methods across all evaluated acceleration rates. In prospectively undersampled free-breathing RT cine data, CineDiff received higher expert image-quality scores. Qualitatively, CineDiff reduced block-like artifacts and preserved finer anatomical detail compared with traditional compressed sensing and a variational network method, termed CineVN. Conclusion: CineDiff enabled high-quality reconstruction of highly accelerated 2D RT cine CMR. The method also demonstrated robustness to out-of-distribution data, including mid-field and porcine acquisitions.

0.33

Coronary Mask Guided Registration for Continuous Time 4D Cardiac CT Dataset Construction

eess.IV cs.CV ·2026-08-28 ·Yuang Wang, Shuo Wang, Changyu Chen, Dufan Wu, Pengfei Jin +10 more
hot direction
Abstract · 12 pages, 7 figures. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after w…

Objective: Clinical cardiac CT multiphase reconstructions generally provide acceptable image quality in end-diastole (ED) or end-systole (ES) phases, but in other phases may exhibit motion artifacts, especially in the right coronary artery (RCA). This limits ground-truth availability in 4D cardiac CT imaging research. We aim to construct a 4D cardiac CT dataset that is generally suitable to serve as pseudo ground truth. Methods: We propose Coronary Mask Guided Registration (CMGR) to produce a motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequence from the clinical multiphase reconstruction of each patient. For artifact reduction, CMGR uses the ED or ES phase as the reference phase and warps the reference volume with deformation fields to produce the sequence. For motion preservation, CMGR registers the reference phase to each non-reference phase of the multiphase reconstruction. To capture the motion of both the RCA and other cardiac structures in each registration, CMGR regularizes RCA masks and incorporates them into image-domain registration. Time-continuity is achieved by interpolating the deformation fields for non-reference phases to arbitrary times. Results: CMGR outperformed representative image-domain registration methods in capturing RCA motion and providing reasonable RCA shape, and showed competitive performance in capturing whole-heart motion. Additionally, CMGR reduced motion artifacts from clinical multiphase reconstructions, and intermediate CMGR frames generally provided plausible transitions between discrete cardiac phases. Conclusion: CMGR provides an effective approach for constructing continuous-time 4D cardiac CT datasets. Significance: The dataset can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.

0.33

Efficient JPEG Restoration in the Wavelet Domain via Mean Flows

eess.IV cs.CV ·2026-08-28 ·Stefan-Alexandru Asandei, Mihai-Alexandru Radu
Abstract · 9 pages, 2 figures, 6 tables. Code will be released soon

Latest JPEG restoration systems achieve strong quality with large models, yet often remain too slow and expensive for efficient on-device deployment. We present a 65M-parameter generative restorer that attains the lowest LPIPS at QF 10 and 20 on LIVE-1, Urban100, and DIV2K-val while sustaining 8.05 images/s at $1024\times1024$ on a single RTX 3090, roughly $4.9\times$ the reported throughput of one-step SODiff at one-twentieth of its parameters. Trained from scratch, the model replaces the learned VAE encoder-decoder with an exactly invertible two-level Haar transform, predicts a clean wavelet-domain residual through a rank-enhanced linear-attention DiT that estimates compression severity internally, and is optimized with an improved MeanFlow objective that enables inference in one or two network evaluations without distillation. Large pretrained priors remain stronger under severe compression (QF 5), whereas our model prioritizes throughput for deployment-constrained restoration.

0.25

Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction

eess.IV cs.CV ·2026-08-28 ·Dat Tat Mai, Thai Viet Pham, Thu Nguyen Thi Dang, James Jin Kang
Abstract

Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged metrics like PSNR and SSIM miss. We review whether current evaluation practices detect this blind spot. Methods: Following PRISMA 2020, we searched seven databases without date limits, including 263 studies (1995-2026), appraised them using QUADAS-2 and matched instruments, and synthesized narratively. Categories were derived from titles, abstracts, and controlled vocabulary; reported prevalence figures represent floors. Duplicate screening achieved high agreement (Fleiss kappa = 0.877), as did appraisal (0.788; 0.390 where observable). Extraction is unaudited. Results: Only 18 of 263 studies (6.8%) recorded both a fidelity metric and reader assessment on identical data, leaving the central surrogate unmeasured. Reader studies mostly measured inter-reader agreement, which was weak: fastMRI 2020 concordance reached 0.457 and 0.386 (Kendall W), improving only where SSIM diverged. Erasing a 100 mm3 lacunar infarct shifts global PSNR by 0.03 dB under the stated error model. As the corpus grew fivefold, reader assessments dropped from 32% to 18%, recovering to 21%. Generative models - most associated with hallucination (39%) - were among the least reader-evaluated (11.3%), while self-supervised models reached 47% with zero reader evaluation. Only 5% released code and ran reader studies; none evaluated a model observer; no named dataset covered acute stroke or hemorrhage. Conclusions: On these floors, current evaluation practices cannot certify diagnostic safety. We derive five requirements safety-oriented evaluations must meet.

0.21

Multimodal Deep Learning for Uncertainty-Aware Radiation Pneumonitis Risk Prediction

eess.IV ·2026-08-28 ·Jin Yang, Tian Liu, Jing Wang, Sooyun Caroline Tavolacci, Benjamin Tran +5 more
Abstract · 28 pages, 9 figures, 5 tables

Radiation pneumonitis (RP) is a potentially serious complication of thoracic radiotherapy, making reliable risk prediction important for identifying high-risk patients and guiding effective toxicity management. Although deep learning models can predict RP risk, uncertainty quantification remains underdeveloped in radiation toxicity assessment. We developed a Multimodal Bayesian Diffusion Transformer (MM-DiT) that integrates pretreatment computed tomography (CT) and three-dimensional planning dose distributions for RP risk prediction and uncertainty quantification. MM-DiT combines self-supervised multimodal representation learning with Bayesian classification to estimate individual risk and characterize aleatoric, epistemic, and label uncertainty. In independent Mount Sinai Health System (MSHS) and RTOG cohorts, MM-DiT achieved areas under the receiver operating characteristic curve (AUCs) of $0.89$ and $0.86$, respectively, with expected calibration errors of $0.02$ and $0.03$. Incorporating post-treatment CT increased AUC to $0.95$ in MSHS and reduced aleatoric and epistemic uncertainty by approximately $40-45\%$ and $40\%$, respectively. These findings establish a framework for uncertainty-aware radiation toxicity prediction that complements risk estimates with information about predictive reliability. By integrating multimodal learning and uncertainty quantification, MM-DiT may advance more interpretable and trustworthy AI-assisted toxicity assessment and support individualized radiotherapy planning.

0.19

Do Medical Vision Models Reason About Anatomy? Probing the Spatial Inductive Biases of Learned Visual Representations

eess.IV cs.AIcs.CVcs.LG ·2026-08-28 ·Naren Akash, Neeraja Ramanan
Abstract

Interpreting a CT scan means comparing structures on either side, judging how far apart organs sit, and knowing where each one belongs. Medical vision encoders are evaluated on diagnostic accuracy, or through assembled multimodal systems where a failure is hard to attribute, so it remains unclear whether their representations support any of this. We construct SPAR-Bench, eight probes over multi-organ abdominal CT that separate coordinate localization, relational reasoning, and spatial queries, and apply them to five architectural configurations and three medical foundation models, frozen and finetuned. Probes that ask for a comparison within the slice stay at chance, and neither pretraining scale, finetuning, nor architecture closes the gap. Probes that appear solved in domain fall to chance under zero-shot transfer, indicating that their accuracy reflects recall of canonical anatomy rather than computation over the image. Reading the same frozen features with a pooled head rather than the full set of tokens moves relational recovery from 0.7% to 67.8%, so pooled probing understates what a representation holds. Questions the encoders answer well are answered at chance by four open-weight MLLMs. Our results suggest these encoders carry a map of where organs usually lie, and little of the machinery for comparing structures within a particular patient. Code and data will be available at https://spar-bench.github.io.

0.13

Medical Foundation Model Features as Perceptual Loss for Brain MRI Contrast Dose Simulation

eess.IV cs.CV ·2026-08-28 ·Changsheng Fang, Dayang Wang, T. Campbell Arnold, Enhao Gong, Srivathsa Pasumarthi
Abstract · Withdrawn due to regulatory and internal company requirements

Perceptual losses are widely used in medical image synthesis because they encourage agreement in high-level structure beyond voxel-wise intensity similarity. In practice, most perceptual losses are still computed with natural-image backbones such as VGG16 or ResNet50, even when the target domain is magnetic resonance imaging (MRI). This mismatch may weaken supervision for anatomy, contrast enhancement, and acquisition variability. We test whether medical foundation model features provide a more suitable perceptual loss for brain MRI contrast dose simulation. The study has two stages. First, we compare RadImageNet, SegVol, and BrainIAC with ImageNet-pretrained VGG16 and ResNet50 as frozen feature extractors on four public medical imaging benchmarks: thyroid ultrasound, breast ultrasound, anterior cruciate ligament knee MRI, and meniscus knee MRI. RadImageNet achieves the lowest mean rank across the Stage I representation suite and is selected as $φ^\star$. Second, we replace only the VGG16 feature extractor in an existing iterative brain MRI dose simulation framework with $φ^\star$. The generator, reconstruction loss, adversarial loss, auxiliary losses, optimization schedule, and loss weights are kept unchanged. Standard metrics change modestly, with PSNR increasing from 41.63 to 41.74, SSIM from 0.9739 to 0.9754, RMSE decreasing from 0.1384 to 0.1369, and residual-uptake CNR from 0.0085 to 0.0082. The visual results show the main effect: RadImageNet reduces residual enhancement in marked structures, follows a more faithful dose-reduction trajectory, and remains close to the acquired 10% low-dose target. These results support domain-aligned radiology features as a practical perceptual feature space for MRI dose simulation, while leaving clinical equivalence and larger-cohort validation as future work.

Theory & Algorithms 1

Ada-TokenCom: Rate-Adaptive Token Communications via Large-Model-Driven Token Compression and Generation

cs.IT cs.CVeess.IV ·2026-08-28 ·Zijun Zhang, Li Qiao, Mahdi Boloursaz Mashhadi, Zhen Gao, Mehdi Bennis +1 more
Abstract

Token Communications (TokenCom) has recently emerged as a new paradigm in which tokens serve as unified units for communication and computation, enabling efficient multimodal semantic and goal-oriented transmission. In this paper, we develop Ada-TokenCom, a rate-adaptive TokenCom framework based on large autoregressive models, which integrates next-token prediction with arithmetic coding to achieve ultra-low bitrate semantic communication at the token level. We propose a mixed reconstruction/generation scheme, where the transmitter encodes and transmits the highly informative tokens at the beginning of the token sequence leveraging a pre-trained autoregressive large model, while the receiver uses an identical model to predict the rest. Moreover, we design a Lyapunov-based algorithm to dynamically optimize both the source compression rate and the modulation and coding scheme, adapting to time-varying network conditions. Simulation results demonstrate that our proposed Ada-TokenCom framework outperforms both digital and deep joint source-channel coding-based semantic communication baselines.

0.42