CS Paper Radar

Daily listing

2026-10-09 · eess.IV

14 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 1

Physics-Aware Self-Supervised Pretraining on Multi-Domain Raman Spectra

cs.LG cs.CVeess.IV ·2026-10-09 ·Charalampos Davalas, Georgios Levantinos, Anastasios Dimitriou, Nikolaos Papanikolaou, Georgios Th. Papadopoulos +1 more
Abstract

Raman spectroscopy generates large volumes of unlabeled data that are difficult to exploit with conventional supervised learning. This work introduces a multi-domain self-supervised learning framework based on a masked autoencoder (MAE) for learning transferable Raman spectral representations from heterogeneous biological, chemical, forensic, and materials datasets. The proposed pretraining strategy incorporates physics-aware objectives by combining masked intensity reconstruction with a sparse Voigt-profile decoder that models spectral peak structure through differentiable peak centers, widths, and amplitudes. A denoising objective is further included to improve robustness to spectral corruption. The learned encoder is evaluated on substance classification, component identification, concentration estimation, and spectral denoising under linear probing, attention-based probing, end-to-end fine-tuning, and training from scratch. Experimental results show that self-supervised pretraining is most beneficial for challenging tasks with limited labeled data. Attention-based probing also reveals substantially more useful information in the frozen representation than linear probing, indicating that conventional linear evaluation may underestimate representation quality. In addition, the benefits of pretraining become more pronounced with increasing encoder capacity. Overall, the proposed framework demonstrates that physics-aware, multi-domain self-supervised pretraining can improve label efficiency, robustness, and transferability across diverse Raman spectroscopy tasks.

0.20

Language, Vision & Media 13

Can Multimodal Decision Models Classify Breast Ultrasound Images? Benchmarking CLEF and CLEF-Flash Across Prompts and Datasets

eess.IV cs.CV ·2026-10-09 ·Tran Cao Minh, Hai Tran, Ha Minh Tan
Abstract

Multimodal decision models return probabilities over predefined alternatives, offering a structured interface for image classification. This study benchmarks inference with CLEF and CLEF-Flash on 2818 breast ultrasound images from Dataset B, BUSI, and BUS-BRA. Dataset B and BUS-BRA use binary benign-malignant classification, whereas BUSI includes normal, benign, and malignant categories. Model parameters remain unchanged, and original images are submitted without user-defined preprocessing. Three prompts provide minimal labels, an explicit classification task, or sonographic criteria. We report accuracy, macro F1, balanced accuracy, macro precision, throughput, and latency. CLEF-Flash with the clinical prompt achieves the highest accuracy on all three datasets: 74.85% on Dataset B, 66.28% on BUSI, and 51.63% on BUS-BRA. On BUSI, however, CLEF with the task-guided prompt achieves the highest macro F1 (64.51%) and balanced accuracy (68.72%). CLEF-Flash has lower latency in every matched comparison. Clinical instructions improve CLEF-Flash accuracy relative to the minimal prompt but reduce CLEF accuracy on all datasets. Confusion matrices reveal frequent benign-to-malignant errors, particularly on BUS-BRA, where all configurations fall below the 67.63% accuracy of a majority-class predictor. These findings demonstrate dataset-and prompt-dependent performance and motivate class-specific evaluation before applying multimodal decision models to breast ultrasound analysis.

0.51

Radiomics-Based Thyroid Nodule Classification with Label-Conditional Conformal Prediction

eess.IV cs.CVstat.AP ·2026-10-09 ·Laura Testa, Pierpaolo Brutti, Umberto Ferraro Petrillo
published
Abstract · Accepted at the CIBB 2026 conference (https://cibb2026.teralab.ai/)

Thyroid nodule malignancy assessment relies on ultrasound imaging, yet current risk stratification systems suffer from substantial interobserver variability, contributing to a high rate of unnecessary biopsies. We propose a radiomics-based framework combining quantitative feature extraction via PyRadiomics with a Generalized Additive Model (GAM) classifier, selected among six candidates for its favorable trade-off between discriminative performance and interpretability. To complement point predictions with uncertainty estimates, Cross-Conformal Prediction with label-conditional guarantees is applied, flagging ambiguous cases for clinical review rather than forcing a binary decision. Experiments are conducted on TN5000, a publicly available ultrasound dataset of thyroid nodules. After Spearman correlation filtering, 36 features are retained and the GAM achieves an AUC of $0.89$, a sensitivity of $0.83$, and a specificity of $0.82$ on the validation set. At a significance level $ε=0.09$, selected to ensure empirical coverage guarantees on both classes, 63\% of nodules on the test set receive a certain (i.e., single-label) prediction, with conditional precision of $0.94$ for certain malignant and conditional Negative Predictive Value (NPV) of $0.73$ for certain benign cases, while the remaining 37\% are referred to the clinician.

0.47

Model-agnostic Knowledge Augmented Machine Learning for Weakly Annotated Bioimaging Data

eess.IV cs.AIcs.CV ·2026-10-09 ·Jayanie Bogahawatte, Sachith Seneviratne, Simon Maksour, Dzung Do-Ha, Elizabeth Qian +4 more
Abstract

Machine learning models are increasingly used for automated feature extraction from weakly annotated bioimaging data, such as microscopy and cytomorphology images. Due to the sole dependency of automated feature extraction, existing methods yield inconsistent classification performance across weakly annotated datasets. Here, we propose a model-agnostic knowledge augmentation method that enables ML models to exploit domain knowledge beyond what automated feature extraction can capture. The proposed approach improves classification performance across seven ML architectures. When integrated with masked autoencoder-based self-supervised learning, our method achieves the strongest overall performance, improving precision by 2.9% over the next-best method on three in-house microscopy datasets and by an average of 6.8% across three public cytomorphology benchmarks. We perform nucleus-level classification based on mislocalization of TAR DNA-binding protein 43 (TDP-43) from the nucleus to the cytoplasm, a phenotype linked to Amyotrophic Lateral Sclerosis (ALS), using three independent microscopy datasets of motor neurons derived from human induced pluripotent stem cells. Accurate quantification of this phenotype at scale remains challenging and may contribute to inconsistencies across studies. Application of the best-performing model to these microscopy datasets reveals biological interpretations related to ALS, including dose-dependent effects of the proteasomal stressor, MG132, and the oxidative stressor, sodium arsenite (SA), on TDP-43 mislocalization, variable pathology in motor neurons from sporadic and familial ALS donors, and a lack of protection of the pharmacological compounds, edaravone and niclosamide, against SA-induced TDP-43 mislocalization. Together, our pipeline enables in-vitro cellular image analysis to advance understanding of ALS-associated pathology and potential treatments.

0.40

Beyond Discrimination: Evaluating Probability Calibration in Radiomics-Image Fusion for Renal Cell Carcinoma Classification

eess.IV cs.AIcs.CVq-bio.QM ·2026-10-09 ·Yuan Liang, Morgan May, Abraham Campbell, Sourav Bhattacharjee, Simon Caton +1 more
top venue
Abstract · 12 pages. 1 figure. Accepted at the 2026 Irish Conference on Artificial Intelligence and Cognitive Science (AICS 2026). Proceedings forthcom…

Reliable probability estimates are important for the clinical interpretation of machine-learning classifiers, yet radiomics--image fusion models for renal cell carcinoma (RCC) are commonly evaluated primarily by discrimination. Using 396 patients from the KiTS23 dataset, we evaluated whether adding radiomics to four image-model families improved probabilistic performance in addition to discrimination. Seventeen individual models and four probability-average ensembles were assessed using discrimination, probability calibration, and proper scoring measures. Across 12 matched image-only versus fusion comparisons, AUC and AP improved in all 12, while Brier score and negative log likelihood (NLL) improved in 11 of 12 and expected calibration error (ECE) in eight of 12. The 3D MedVAE gated-fusion model achieved the strongest overall individual-model profile. Probability averaging across concatenation, cross-attention, and gated fusion produced favourable point estimates across all five primary metrics relative to image-only models in all four families, although paired-bootstrap support was stronger for Brier score and NLL than for ECE. These findings show that radiomics--image fusion can improve probabilistic prediction quality beyond discrimination, while calibration behaviour varies across image architectures and fusion strategies. We show that our proposed probability-average ensemble models improve discrimination and calibration simultaneously across all architectures in the study.

0.38

Frozen Site-Probe Accuracy Is Not a Standalone Harmonization Score: An Audit of Evaluation Practice for Multi-Site MRI

eess.IV cs.CV ·2026-10-09 ·Muhammad Muqsit Islam, Gloria García Cuenco, José M. Martínez, Pierrick Coupé
code/data
Abstract · 4 pages, 2 figures, 1 table. Submitted to IEEE ISBI 2027. Code and results: https://github.com/muqsitamir/HarmonIt. This work has been submi…

Image-level MRI harmonization is often evaluated with a frozen site probe, a site classifier trained on raw scans and applied unchanged to harmonized ones: a drop in its accuracy is read as removal of site effects. We audit this practice on ABIDE I (1,112 T1-weighted scans, 17 sites) with ten output sets from seven harmonization methods and controls for chance, head shape, intensity, preprocessing and target alignment. We find that this verdict depends on how the probe is trained, even among probes that classify raw scans well: across random seeds, its balanced accuracy on the same CycleGAN outputs ranges from 0.13 to 0.59 (chance: 0.06). Low frozen-probe accuracy can also arise without harmonization: a Gaussian blur, which increases the intensity distance to the target site, lowers this accuracy to chance. Moreover, where the frozen probe fails, probes trained on the harmonized scans still recover the site, even from intensity histograms alone: on HACA3 outputs, the frozen probe scores 0.25, a probe trained on those outputs 0.75, and one using only their intensity histograms 0.71. Low frozen-probe accuracy therefore does not show that site information has been removed. We recommend reporting several probes trained to convergence, probes trained on harmonized scans, and target alignment.

0.33

Desertification Forecasting in Semi-Arid Regions: Using Deep Learning to Probe the Observability Limits of Land Degradation Dynamics

eess.IV cs.LG ·2026-10-09 ·Filipe Moura Da Silva, Cláubio Landney Lima Bandeira
Abstract · 14 pages, 10 figures, 7 tables

Forecasting desertification has received far less attention than mapping it. We use a convolutional LSTM (ConvLSTM) trained on ten annual Earth Observation (EO) variables (2000-2023) over the semi-arid state of Ceará, Brazil, on a 256x206 grid at roughly 2.2 km resolution, to measure how much of the year-to-year evolution of a MapBiomas-derived degradation index (IDV) can be predicted from satellite data. The network predicts a bounded change on top of the last observed state, is trained in two stages (single-step, then recursive rollout) and is evaluated on a contiguous spatial and temporal holdout. State-wide mean IDV rose from 0.238 to 0.350 between 2000 and 2023, about 0.005 per year, but cell-level change is dominated by year-to-year jumps, and a gradient-boosting model given all channels explains only 4.7% of its variance. Against this ceiling, the ConvLSTM lowers RMSE relative to persistence by 1.6% one year ahead and 4.4% four years ahead in a held-out southern band (p < 0.001), beats persistence with a constant drift and reproduces 53-69% of the regional drift. Drift-aware baselines only help from the third year onward, by up to 4.4% in RMSE at six years. An earlier formulation that redrew the whole field each year predicted changes unrelated to the observed ones (correlation -0.06) and produced a spurious decline when run recursively. Channel knockouts suggest that elevation and EVI degrade the forecast, while slope and aspect have no measurable effect. Monte Carlo dropout and stochastic scenario maps convey the uncertainty that the expected-value forecast hides. Under climatological forcing, mean IDV rises from 0.350 in 2023 to 0.370 in 2030. EO-based desertification forecasting is therefore reliable for the regional trend, not for individual cells.

0.31

Beyond Gate Weights: Decision-Level Interpretation of Radiomics-Image Feature Fusion for RCC Classification

eess.IV cs.AIcs.CV ·2026-10-09 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
top venue
Abstract · 12 pages, 1 figure. Accepted at the 2026 Irish Conference on Artificial Intelligence and Cognitive Science (AICS 2026). Proceedings forthcom…

Gate coefficients describe how a fusion layer weights intermediate features, but they do not necessarily reflect the magnitude of branch contributions at the classifier output. We investigate this distinction in a fixed 3D MedVAE--radiomics model for clear cell versus non-clear cell renal cell carcinoma classification from contrast-enhanced CT. Because the model uses a linear classification head, the binary decision logit can be decomposed exactly into a gated image term, a direct radiomics term, and a bias. We define effective radiomics dominance as the direct radiomics term's share of the summed absolute non-bias branch contributions and compare it with structural radiomics weighting. Internally, mean structural radiomics weighting was 0.823, whereas mean effective radiomics dominance was 0.148, with a modest case-wise association (\r{ho} = 0.290). The gated image term retained substantially stronger discriminative ranking information than the direct radiomics term. The same structural-to-effective discrepancy was observed in exploratory external evaluation. Branch-targeted permutation, integrated-gradient, and Shapley-style analyses further identified radiomics descriptors influencing the direct radiomics term. Because radiomics also generates the gate, the gated image term remains radiomics-dependent, so additive branch contribution should not be interpreted as total input influence. These findings show that structural gate weighting and decision-level branch contribution represent distinct aspects of gated feature fusion and should be interpreted separately.

0.28

A Configurable ETC2 Encoder with Learned Search

eess.IV cs.CV ·2026-10-09 ·Ziyu Guo, Haomiao Jiang, Sergey Makeev, Angelo Pesce
unusual
Abstract

ETC2 fixes the texture representation and bit rate, leaving the encoder to trade search time for distortion. We present a configurable CPU encoder in which rules or small neural networks allocate conventional ETC2 searches; these searches construct every encoded block. Configurations span fast-encoder output through broader mode and endpoint searches. On 64 color textures used to evaluate and select configurations, the fastest measured configurations reaching at least Google Etc2Comp's pooled REC709 PSNR at efforts 0-49.5 run 30.7-40.9 times faster. A high-quality configuration exceeds effort-100 PSNR with 64.1% less time. At equal search quotas, learned action ranking and second-search allocation jointly gain 0.124 dB over rule-based choices. At high quality, learning saves time at a small distortion cost. Outputs retain standard ETC2 storage and hardware decoding.

0.24

Stochastic Finite-Transition Learning and Exploration for Accelerated MRI Reconstruction

eess.IV cs.CVeess.SP ·2026-10-09 ·Muhammad Usama Mirza, Esin Öztürk Işık, Tolga Çukur
Abstract

Generative MRI reconstruction maps an initial source distribution to the target image distribution along a learned recovery trajectory. Common generative methods, such as diffusion and flow, typically learn fine-grained local dynamics whose integration defines this global mapping, hence requiring many network evaluations at inference. Existing few-step sampling approaches can lower computational burden by approximating large transformations from local dynamics, albeit at the expense of reconstruction fidelity. FLEX-MRI instead partitions recovery into a small number of finite intervals between retained states defined by progressive changes in k-space support, and directly learns the reconstruction change across each interval. Because such finite transitions can admit multiple plausible outcomes, FLEX-MRI combines support-relaxed finite-transition learning with stochastic exploration. During training, randomized k-space sampling masks define finite-transition targets with varying support, while the prediction loss remains unrestricted by each individual mask. At inference, FLEX-MRI perturbs a random subset of currently estimated k-space coefficients, allowing the learned predictor to stochastically explore alternative transition paths. Each predicted state is then reconciled with the acquired measurements through data consistency. We theoretically show that this stochastic exploration induces nonzero transition-level variation through the learned recovery map and data consistency without requiring an auxiliary generative sampler. Experiments on multi-coil MRI datasets show that FLEX-MRI outperforms competing methods while maintaining computational efficiency comparable to few-step baselines.

0.23

A Miniaturized Wi-Fi HaLow-Based Wireless Imaging Transfer System for Capsule Endoscopy

eess.IV ·2026-10-09 ·Michele Bertozzi, Lorenzo Amelio, Sebastiano Strangio, Nikita J. Greenidge, Benjamin Calmé +3 more
Abstract

Wireless capsule endoscopy is constrained by severe limitations in size, available power, and reliable data transmission through biological tissues. Although recent advances in miniature imaging sensors have improved image quality, the wireless transmission of color images at practical frame rates remains a challenging task under the tight capsule constraints. We present the design and the experimental validation of a miniaturized Wireless Imaging Transfer (WIT) system for capsule endoscopy based on a sub-GHz IEEE 802.11ah (Wi-Fi HaLow) wireless link. In addition, a preliminary in-vivo validation of Wi-Fi HaLow communication is reported, showing that a stable through-body wireless link can be established across biological tissues in a clinically relevant porcine model. These in-vivo results provide direct experimental support for the adoption of sub-GHz Wi-Fi HaLow for capsule endoscopy applications. Experimental results demonstrate stable wireless image transmission at a resolution of 320x320 pixels, with measured end-to-end data rates above 12 Mbps and a transmission energy efficiency of 20.7 nJ/bit. We also report a detailed power consumption analysis, with a breakdown of the contributions from the imaging sensor, illumination, digital processing, and RF transmission. When all active subsystem contributions are considered, including the camera, digital processing, RF transmission, and illumination at 60% LED brightness, the total power consumption is approximately 477 mW, corresponding to a complete-chain energy consumption of approximately 39.6 nJ/bit. Overall, the measured performance confirms that sub-GHz Wi-Fi HaLow provides a promising trade-off among throughput, robustness, and energy efficiency for wireless imaging in capsule endoscopy.

0.22

C$^2$LUE: Clinically Aligned Patient-Level Ultrasound Diagnosis via Evidence-Aware Multi-Instance Learning

eess.IV cs.CV ·2026-10-09 ·Qin-Yi Zhang, Linying Cao, De-Xing Huang, Haichuan Lin, Yi Yang +5 more
Abstract

Patient-level ultrasound diagnosis demands not only high predictive accuracy but also clinically aligned mitigation of asymmetric diagnostic risks. While Multi-Instance Learning (MIL) effectively models routine multi-view exams, standard aggregators often dilute heterogeneous diagnostic cues and optimize solely for global accuracy. This frequently yields undesirable sensitivity-specificity trade-offs. To bridge this gap, we propose C$^2$LUE, a novel MIL framework coupling evidence aware aggregation with risk-aligned regularization. To preserve evidence heterogeneity and prevent unimodal attention collapse, C$^2$LUE employs a multi-query cross-attention mechanism built upon a LoRA-adapted DINOv3 backbone. Multiple latent queries explicitly extract and disentangle diverse morphological patterns from the ultrasound sequence. Furthermore, to improve clinical risk alignment, we introduce a dynamic trade-off regularization objective that penalizes sensitivity-specificity imbalance during training. Rather than leaving the clinical trade-off entirely to post-hoc threshold adjustment, this objective encourages the learned score distribution toward a more balanced operating region. Extensive evaluations on patient-level, biopsy-proven thyroid and breast ultrasound datasets demonstrate that C$^2$LUE consistently outperforms prior alternatives. By uniting strong discrimination with a balanced error profile, C$^2$LUE provides a promising solution for real-world ultrasound screening and diagnosis.

0.21

The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging

eess.IV cs.CVcs.LG ·2026-10-09 ·Fabian Drexel, Bernhard Kainz, Jakob N. Kather, Daniel Rueckert, Lisa C. Adams +2 more
Abstract · 45 pages, 6 figures

Joint-embedding predictive architectures (JEPAs) learn by predicting teacher representations of masked regions from visible context. Point prediction summarizes the conditional target distribution and cannot reproduce variation that the context does not resolve. We call this constraint predictability bias. In computed tomography (CT), recurrent anatomy is predictable from context, whereas the sporadic, localized pathology that determines clinical interpretation often is not. We introduce TAP-JEPA, a ViT-B/3D trained on 113,611 CT volumes that is competitive with state-of-the-art encoders (COLIPRI, Merlin, VoxelFM) in scan-level classification. We then audit the learned predictive pathway by replaying the exact masking, teacher, and predictor computations used during training. Prediction lowers the mean Skill (prevalence-normalized average precision) from 0.388 to 0.271 for pathology, but only from 0.921 to 0.873 for anatomy. Along the teacher direction, separating pathology from matched control regions in the same organ, prediction moves pathology 34.7% toward the controls and controls 13.6% toward pathology, with larger shifts farther from visible context. Replacing visible matched-control representations increases surrounding-target prediction loss more than fully replacing pathology representations across four pathology categories. Downstream, removing all final-layer pathology tokens reduces the decision margin by at most 0.45% in four of seven scan-level probes. Together, these results show that contextual predictability is not a sufficient proxy for clinical relevance in medical representation learning. Training objectives should therefore retain diagnostic features regardless of their predictability from surrounding anatomy.

0.19

Exploring the Latent Structure of AMD Severity Using Retinal Foundation Models

eess.IV cs.CV ·2026-10-09 ·Niccolò Fineschi, Jovana Panic, Atsushi Watanabe, Hideaki Hayashi, Kazuya Nishimura +5 more
published
Abstract · 7 pages, 5 figures. Accepted for publication at IEEE EMBS BHI 2026

Retinal foundation models have demonstrated strong performance across a wide range of ophthalmic tasks, yet relatively little is known about how disease-related information is represented within their learned embeddings and whether this distribution influences downstream prediction performance. In this work, we use Age-related Macular Degeneration (AMD) as a case study to investigate how disease severity is represented within the embedding space of RET-CLIP, a retinal vision-language foundation model, using bilateral fundus images from the AREDS dataset, benchmarked against non-retinal encoders. We first characterize the distribution of AMD severity within the learned representation space and then evaluate how this structure influences classification performance across three clinically relevant task formulations of increasing granularity. Finally, we analyze the most influential latent dimensions combining feature attribution, statistical phenotype association, and qualitative image analyses. Our results show that RET-CLIP represents AMD severity as a continuous spectrum rather than a set of discrete categories, with healthy and advanced disease stages exhibiting clearer separation than intermediate ones. This organization was reflected in downstream performance, which decreased from a balanced accuracy of 0.844 and 0.814 for binary AMD and Late-AMD detection respectively to 0.446 for six-class grading. Furthermore, the most influential latent dimensions were statistically associated to distinct retinal phenotypes, including drusen accumulation, pigmentary alterations, and advanced retinal lesions. These findings suggest that the structure of retinal foundation-model representations influences the difficulty of clinically relevant prediction tasks and demonstrate the potential of representation-level analysis for understanding disease organization and improving interpretability.

0.18