CS Paper Radar

Daily listing

2026-10-13 · eess.IV

13 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 13

Simplifying and Improving On-Policy Distillation for Few-Step Diffusion

cs.CV cs.LGeess.IV ·2026-10-13 ·Jiawei Zhang, Ziyu Wan, Nanye Ma, Long Zhao, Dong Chen +3 more
code/datacommunity pick
Abstract · Project Page: https://zjwfufu.github.io/SMD-Page/

Few-step distillation reduces the sampling cost of diffusion and flow models, but existing approaches often require auxiliary score models or specialized architectures. We show that simple on-policy velocity regression already provides a strong foundation for 4-NFE generation. To represent teacher velocity variation within each coarse transition, we introduce Pivot, a training-only residual proxy that separates local corrections from the student's interval-mean prediction. We further repel the student from weaker teacher predictions, providing a lightweight mechanism for avoiding undesirable modes. The resulting framework, Simplified Matching Distillation (SMD), remains entirely regression-based, requires neither online score estimation nor adversarial training, and leaves the deployed generator unchanged. We evaluate SMD on image generation and editing, 3D generation, video synthesis, and joint audio--video generation, scaling to 33 billion parameters. At 4-NFE, SMD outperforms strong few-step baselines and surpasses multi-step teachers on several benchmarks. It also supports cross-model, multi-teacher, and causal-video distillation.

0.49

Deficit-Driven Stratified Acquisition for Building STRATA-S12: An Open SAR-Optical Corpus for Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-10-13 ·Christian Sanchez-Leon, Dongming Chen, Dongqi Wang
Abstract · v3: substantially revised. The ordering analysis is now a replay over all 2,928,370 real acquisition attempts (deficit-driven vs. round-robi…

Building a co-registered SAR-optical corpus for self-supervised Earth Observation is above all an acquisition problem, yet the main multi-modal datasets are collected opportunistically, with no per-stratum quota control, so the regions and seasons that cloud cover hits hardest end up under-sampled. We present Deficit-Driven Stratified Acquisition (DDSA), an algorithm that casts the construction of a Sentinel-1/Sentinel-2 corpus as a constrained maximum-coverage problem over a land-cover-driven, hemisphere-corrected (class x season x region) stratification of target countries on all six inhabited continents, and solves it online: acquisition is ordered by marginal gain against a per-stratum deficit that the quality gates and a visual review of every accepted pair keep updating during the run. Three results follow from measuring the algorithm on its own product. First, stratum balance is a property of the deficit-driven ordering rather than of run length: replayed over all 2,928,370 real acquisition attempts, failures included, it populates all 192 strata within 0.05% of the attempts, against 4.03% for uniform round-robin effort and 20.5% for a random order. Second, whether a rejected attempt can be recovered is better predicted by how long its cause persists than by the type of defect: cloud rejections are recovered at eta = 18.8% against 41.4% for nodata, consistent with clouds persisting through a season. Third, the repair loop supplies 39.5% of the released pairs at no measurable quality cost, with 89.8% surviving manual review, but it adds yield rather than balance. The quality guarantee has a price: 2,928,370 acquisition attempts produced 740,746 released pairs. We release the corpus, STRATA-S12, with per-pair metadata sidecars aligned with the STAC and PDS4 standards and the FAIR principles, and a pre-registered linear probe confirms it is fit for self-supervised pre-training.

0.45

Deep Learning for Atmospheric Turbulence Mitigation: A Comparison Between GANs and Transformers

eess.IV cs.CV ·2026-10-13 ·Juan S. Carrillo, Jérôme Gilles
publishedhot direction
Abstract · Published in the Journal of Electronic Imaging

Atmospheric turbulence creates complex spatial and temporal distortions that significantly reduce image quality. This work compares two deep learning methods for turbulence reduction: Generative Adversarial Networks (GANs) and Transformer-based models. Both methods are trained and tested on the SOTIS dataset, which includes multi-frame sequences under different turbulence conditions with ground truth references. Our results show an important finding: GAN-based models perform better in severely degraded, low-quality situations, while Transformer-based models achieve better results in moderate to high-quality settings, especially in correcting geometric distortions. We also enhance the Turbulence Mitigation Transformer (TMT) by introducing a refined training strategy, an augmented input design that includes a temporally averaged frame as prior structural information, and a modified loss function that incorporates the Structural Similarity Index (SSIM). These improvements lead to consistent performance gains across various turbulence conditions. Overall, this study provides an in-depth evaluation of deep learning methods for turbulence reduction and offers practical guidance for selecting models in different imaging environments.

0.44

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

eess.IV cs.AI ·2026-10-13 ·Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel +21 more
benchmark
Abstract · 27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

0.37

Focus, Align, and Diffuse: Time-Series-Aware Keyframe Diffusion for Cardiac Dynamic Synthesis from Sparse Observations

eess.IV cs.CV ·2026-10-13 ·Junkai Liu, Haofan Wu, Nay Aung, Joao A. C. Lima, Steffen E. Petersen +1 more
publishedcode/data
Abstract · NeurIPS 2026. Project page: https://cardiofad.github.io/

Dense cardiac dynamics are essential for assessing cardiac function, yet in practice clinicians often observe only extremely sparse measurements. However, recovering full dynamics from such sparsity is a highly ill-posed problem due to the lack of temporal cues. While auxiliary time-series signals like ECG provide physiological guidance, effectively exploiting them is challenging due to the cross-modal representation gap and phase misalignment. In this work, we present CardioFAD, a Focus--Align--Diffuse paradigm that reformulates sparse cardiac dynamic synthesis as a recoverability--alignability anchor discovery problem. Our core insight is that resolving extreme temporal ambiguity requires a compact set of anchor states that are both sufficient to recover the visual trajectory and reliable for ECG--visual alignment. We therefore learn motion-salient keyframes under two complementary principles: trajectory sufficiency, which preserves trajectory-critical intra-modal motion content, and anchor alignment, which promotes consistent inter-modal correspondence at these anchors. We implement the Focus and Align modules optimized by the two aspects. Diffuse then performs two-stage generation by first synthesizing keyframes and subsequently interpolating the remaining frames. Extensive experiments on cardiac MRI and echocardiography videos demonstrate superior visual quality, temporal coherence, and improved functional consistency under the extreme one-shot regime.

0.33

Augmenting Real-time Visualization in Minimally Invasive Surgery with Particle Filtering and Depth-Aware Occlusion Handling

eess.IV cs.RO ·2026-10-13 ·Anuska Sarkar, Partha Acharya, Vishnu Nandury, Kaustav Basu, Subhamoy Mandal
top venue
Abstract · Accept

We present a real-time, hybrid framework for occlusion handling and depth-aware tracking in minimally invasive surgeries (MIS). Occlusions caused by surgical instruments often obscure the region of interest (ROI), affecting surgical precision. To address this, our approach integrates enhanced You Only Look Once (YOLO) based detection, Particle Filtering (PF), and monocular depth estimation using Multiple Depth Estimation Accuracy with Single Network (MiDaS). Occlusion is detected using a distance-based threshold between instruments and ROI. Experimental results demonstrate robust instrument detection with a confidence score of 0.85, effective occlusion event handling, and accurate depth prediction with an MAE of 0.34 cm and RMSE of 0.53 cm. Independent phantom-based validation against stereo depth measurements yielded an MAE of 0.65 cm and RMSE of 0.66 cm. The framework further achieved an occlusion detection accuracy of 81.95\% while maintaining real-time performance at 38.7 FPS. Preliminary surgeon feedback indicates that the proposed visualization framework is clinically relevant and holds promise for future intraoperative image-guided navigation and decision support in MIS.

0.31

Recovery-Oriented Optical System Design Based on Fisher Information

eess.IV physics.optics ·2026-10-13 ·Zhuang Qian, Yan Mo, Hao Tan, Yu Chen, Haibo Wang +3 more
unusual
Abstract · 15 pages, 5 figures, 1 table

Traditional optical system design for imaging applications has long been guided by image quality metrics such as geometrical RMS spot size, wavefront error, and modulation transfer function (MTF). Although these metrics effectively characterize direct imaging performance, they do not necessarily indicate optimal behavior when image restoration is subsequently applied. In modern imaging pipelines, however, optical systems are increasingly combined with physics-based or learning-based restoration methods, making the information transfer properties of the optical system critically important. In this work, we propose a recovery-oriented optical design approach that explicitly links optical system optimization with image restoration performance through an estimation-theoretic framework based on Fisher information. A new design criterion is adopted to ensure that the information encoded by the optical system can be reliably recovered during image restoration. To validate the proposed approach, two dual separated aspheric lenses are designed under identical configurations using conventional RMS-based optimization and the proposed recovery-oriented optimization, respectively. Although the RMS-optimized lens exhibits superior direct imaging quality, it underperforms after image restoration compared to the recovery-oriented design. These results demonstrate that recovery-oriented optical design provides a physically interpretable and effective extension of traditional optical design criteria for imaging systems operating within modern computational imaging pipelines.

0.26

High-resolution retinal matrix imaging via computational motion and aberration correction

eess.IV physics.opticsphysics.app-phphysics.med-ph ·2026-10-13 ·Aymeric Melt, Léo Puyo, Victor Barolle, Claude Boccara, Gereon Hüttmann +1 more
unusual
Abstract · 46 pages, 9 figures

High-resolution optical imaging of the human retina is essential for diagnosing ophthalmic and neurodegenerative diseases. While adaptive optics combined with coherence gating can resolve retinal structures at the cellular scale, it requires complex, costly, and cumbersome hardware to physically correct for ocular aberrations and motion. Matrix imaging offers a powerful digital alternative by leveraging wave linearity to undo aberrations and multiple scattering; however, its in vivo deployment has been hindered by continuous, involuntary eye movements that destroy phase coherence during acquisition. Here, we overcome this fundamental barrier and demonstrate the first in vivo reflection matrix imaging of the human retina using an ultra-simplified optical setup without physical correctors. We introduce a fully computational framework that tracks and compensates for multi-axial ocular motion directly from raw interferometric data, thereby restoring the phase coherence of a multi-spectral distortion matrix. This enables local, high-order aberration correction to achieve diffraction-limited, volumetric imaging of retinal tissues. By shifting the hardware burden to physics-guided numerical computation, this paradigm opens the way for accessible, non-invasive, and high-resolution digital ophthalmology.

0.25

Per-Bundle, Pre-Reconstruction Inversion for Temporal CT: Flux-Compensation Design and Training-Free Empirical-Bayes Estimation

eess.IV ·2026-10-13 ·Guy M Besson
Abstract · v2: title changed from v1 (was "...: Flux-Compensation Design and Multi-Patient Generalization"); corpus results recomputed with the truth-f…

In Temporal computed tomography (TCT) each detector reading sums the photons of up to three rays. Earlier work set the resulting per-bundle limits and tested a learned prior on one patient at one incident count $N_0$; this paper lifts both. N$_0$FC ($N_0$ flux compensation), a bow-tie and tube-current-modulation co-design, equalizes each bundle's detected flux. SNN2 is a per-bundle Poisson maximum-likelihood estimator. V8c is a neural-network corrector trained on 19 patients stratified by water-equivalent diameter (WED). T2bp, a training-free empirical-Bayes post-processor, combines per-bundle Poisson likelihoods with a prior built from the patient's own bundles. Results use that work's Dose Inflation Factor (DIF), charging bias as error. On 23 non-test volumes, N$_0$FC lowers the per-volume median middle-path Cramer-Rao floor, as a DIF, from 23-48 under a flat-fluence (no bow-tie) baseline to 3.3-6.3 at 35-62% of its incident photons, near the equal-attenuation value 13/3 and 1.4-1.7 times below conventional bow-ties; the bow-tie alone achieves this median, and tube-current modulation trims the tail. For bundles with $X_2<6$ (83%), SNN2 attains this floor (median mean-squared-error ratio 1.02); training-free T2bp$\circ$SNN2 lowers the ratio to 0.89 (0.74-1.26). It is best or tied on three of four N$_0$FC test cells (WED 207-342 mm) and trails T2bp$\circ$V8c by 3% on the fourth. V8c beats SNN2 in distribution under baseline acquisition, gains at most 9% under N$_0$FC (losing 14% on the largest in-distribution test patient), and fails on a patient acquired below its training count level. Acquisition co-design removes most of the attenuation-contrast penalty, and training-free estimation attains the resulting limit. The remaining three- to six-fold gap to single-source CT at equal fluence, and the high-attenuation tail, are targets for inter-bundle priors.

0.25

Background2Background: a self-supervised background removal framework for high dimensional microscopy

eess.IV cs.CVphysics.optics ·2026-10-13 ·Guangrui Ding, Haonan Lin, Rong Tang, Bethany Weinberg, Jianpeng Ao +6 more
unusual
Abstract

High-dimensional microscopy captures features across space, time, and spectrum, but complex backgrounds obscure signals. We present Background2Background (B2B), a self-supervised background removal framework leveraging the backgrounds larger correlation relative to the signal. Local pixel shuffling disrupts signal correlations while preserving background structure, transforming signals into effective noise for Noise2Noise-based background removal. Across fluorescence, stimulated Raman scattering and mid-infrared photothermal imaging, B2B achieves over 40-fold background suppression and reveals hidden signatures.

0.22

DoReMe: Dual optimization of Reconstruction and Motion estimation for self-navigated free-breathing abdominal MRI using Gaussian Splatting

eess.IV cs.CVphysics.med-ph ·2026-10-13 ·Majd Helo, Dominik Nickel, Thomas Kuestner
Abstract · 25 pages, 2 tables and 7 figures

Purpose: Free-breathing abdominal MRI is limited by respiratory motion, which introduces image artifacts and k-space inconsistencies. Existing reconstruction approaches often depend on pre-estimated motion fields or external respiratory surrogate signals. We propose a coupled reconstruction-motion estimation algorithm for self-navigated free-breathing acquisition, in which motion is represented by compact Gaussian primitives and jointly refined with the image estimates during iterative reconstruction. Methods: An iterative reconstruction that alternates between data consistency updates and motion modelling was proposed. Respiratory motion was represented using Gaussian primitives. A Gaussian splatting was integrated into the reconstruction algorithm. The method was evaluated on self-navigated free-breathing Cartesian gradient-echo (GRE) acquisition in four healthy volunteers, including retrospective scan shortening experiments, and was compared with regularized compressed sensing (CS) reconstruction. Results: Respiratory motion states were reconstructed in approximately 1.5 min. Compared with CS, the proposed method improved visual image quality, particularly in coronal liver views, and better preserved anatomical structures in retrospectively shortened acquisitions. These findings provide proof of concept for the proposed method. Conclusion: The proposed coupled reconstruction-motion estimation algorithm improved visual image quality compared with CS alone. Gaussian primitives provided a compact and sufficiently flexible representation of nonrigid respiratory motion with practical runtime, supporting further scanner integration and validation in larger cohorts.

0.22

Perceptual Characterization of Scan-induced Artifacts in Dynamic 3D Meshes

eess.IV cs.MM ·2026-10-13 ·Huong Hoang, Truong Nguyen, Pamela Cosman
Abstract

Dynamic meshes reconstructed from real-world scenes often exhibit scan-induced artifacts such as surface jitter and missing geometry, which strongly impact perceived visual quality. Objective assessment remains challenging due to the absence of artifact-free ground truth and limited perceptual understanding of artifact interactions. This paper presents a systematic and controlled perceptual study of scan-induced artifacts in dynamic meshes, focusing on surface jitter and holes. To enable systematic analysis, we introduce a physically grounded artifact synthesis framework in which holes are synthesized using a reconstruction uncertainty model derived from multi-view geometry. The study reveals asymmetric cross-artifact interactions, non-additive integration, and motion-dependent temporal masking. Based on these findings, we propose a compact, perceptually grounded no-reference quality assessment framework that encodes the observed perceptual mechanisms.

0.20

Low-Altitude Agentic Networks: From UAV Connectivity to Workflow-Driven Capability Orchestration

eess.IV ·2026-10-13 ·Baolin Chong, Fuhui Zhou, Qihui Wu, Ran Tu
Abstract

Low-altitude platforms are evolving from connected sensing nodes into autonomous agents capable of bounded task interpretation, skill invocation, and local decision making. Increasing the intelligence of individual unmanned aerial vehicles (UAVs), however, does not resolve the organization problem that arises when mission workflows depend on capabilities distributed across multiple platforms and provider feasibility changes with network, resource, and mobility conditions. We propose low-altitude agentic networking as a task-level networking paradigm and develop a reference architecture that separates workflow logic from executor identity. Within a validated domain-specific workflow space, each ready operation is translated into a capability requirement and dynamically bound to an agent that remains feasible under current conditions. Task contracts and structured evidence govern workflow execution, while routine provider and link changes are handled through workflow-preserving local adaptation before high-level repair is invoked. A trace-calibrated discrete-event case study identifies a bounded operating region: conventional organization remains effective for simple workflows under stable conditions, whereas agentic networking becomes beneficial when workflow dependencies are tightly coupled, capability feasibility changes during execution, and viable local recovery paths remain available.

0.12