CS Paper Radar

High-resolution retinal matrix imaging via computational motion and aberration correction

Aymeric Melt, Léo Puyo, Victor Barolle, Claude Boccara, Gereon Hüttmann, Alexandre Aubry

eess.IV physics.opticsphysics.app-phphysics.med-ph ·submitted 2026-10-13 22:01 UTC · v1
unusual

Abstract

High-resolution optical imaging of the human retina is essential for diagnosing ophthalmic and neurodegenerative diseases. While adaptive optics combined with coherence gating can resolve retinal structures at the cellular scale, it requires complex, costly, and cumbersome hardware to physically correct for ocular aberrations and motion. Matrix imaging offers a powerful digital alternative by leveraging wave linearity to undo aberrations and multiple scattering; however, its in vivo deployment has been hindered by continuous, involuntary eye movements that destroy phase coherence during acquisition. Here, we overcome this fundamental barrier and demonstrate the first in vivo reflection matrix imaging of the human retina using an ultra-simplified optical setup without physical correctors. We introduce a fully computational framework that tracks and compensates for multi-axial ocular motion directly from raw interferometric data, thereby restoring the phase coherence of a multi-spectral distortion matrix. This enables local, high-order aberration correction to achieve diffraction-limited, volumetric imaging of retinal tissues. By shifting the hardware burden to physics-guided numerical computation, this paradigm opens the way for accessible, non-invasive, and high-resolution digital ophthalmology.

Comment
46 pages, 9 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Differentiable Inverse Rendering Recovers Intrinsic Properties from Intravascular Optical Coherence Tomography

cs.CV eess.IVphysics.med-phphysics.optics ·2026-11-09 ·Ajay Manicka, Karim Kadry, Sebastian Ruiz-Lopera, Maryam Alsharqi, Sanjana Arji +5 more
similarity 0.63
Abstract · 27 Pages, 6 Figures, Under Review

Medical images encode intrinsic tissue properties that indicate disease progression, yet these properties remain entangled with the system-dependent physics of image formation. Differentiable inverse rendering asks whether they are recoverable by inverting the imaging system's forward physics rather than through post-hoc correction. We address this in optical coherence tomography (OCT), focusing on the optical attenuation coefficient, a per-pixel marker of pathology and cellular composition. Conventional recovery relies on closed-form inversions limited to simplified light-tissue models, or learned methods coupled to specific imaging configurations. We instead recover per-pixel attenuation from a single OCT image by gradient descent through a differentiable physics-based forward model. We verified the method against analytical solutions, validated it on five in vitro phantoms, and applied it without modification to 29{,}269 clinical intravascular OCT images from 128 patients. The inversion needs no training data or segmentations and is portable across platforms and retrospective archives. Replacing the forward model or recovering another optical parameter leaves the optimization procedure unchanged. We demonstrate per-pixel recovery is tractable because gradient information scales to this high-dimensional problem, where gradient-free methods become intractable. Our work supports quantitative tissue characterization from OCT images and provides a framework for extension across imaging modalities and organ systems.

0.26

Perturbation-Based Reconstruction of Depth-Resolved OCT Attenuation without Requiring a Fully Decayed Signal Tail

eess.IV physics.optics ·2026-11-04 ·Jinglun Yu, Yaning Wang, Shuwen Wei, Jin U. Kang
unusual similarity 0.58
Abstract · 26 pages, 10 figures, including 1 supplementary figure. Submitted to Biomedical Optics Express

Depth-resolved attenuation in optical coherence tomography (OCT) can provide quantitative optical contrast beyond structural imaging. However, conventional reconstruction methods can be biased when the OCT signal does not fully decay within the imaging range or when the distal signal tail is dominated by noise or residual reflections from distal sample or support interfaces. Here, we present a perturbation-based Beer-Lambert framework that combines a zeroth-order exponential estimate with a first-order correction, reducing reliance on the unreliable distal signal tail below the current depth. Numerical A-line simulations, Monte Carlo modeling, multilayer silicone-dye-TiO2 phantoms, and ex vivo bovine retina experiments were used to evaluate the method under finite-depth and heterogeneous imaging conditions. The numerical A-line tests showed reduced depth-dependent error against prescribed attenuation profiles; the Monte Carlo comparisons showed less distal drift relative to model-defined benchmarks, while the phantom profiles were compared with separately acquired single-layer OCT calibration values. In a Monte Carlo component test that withheld vessel-mask and vessel-boundary information from reconstruction and used that information only for post hoc evaluation, the first-order correction recovered 61% of the segmentation-informed target vessel contrast and reduced vessel ROI mean absolute error by 65% relative to the fixed zeroth-order baseline. These results suggest that perturbation-based reconstruction may provide a practical approach for depth-resolved reconstruction of effective OCT attenuation when the fully decayed A-line condition is not satisfied.

0.30

Compact Snapshot Spectral Imaging with Calibration-Free Aperture Diffraction

cs.CV ·2026-08-29 ·Tao Lv, Quan Yuan, Shiqiao Li, Chenglong Huang, Linsen Chen +3 more
unusual similarity 0.56
Abstract · Submitted to IEEE TPAMI. Under Review

Snapshot Spectral Imaging (SSI) provides high-dimensional temporal-spatial-spectral observation to uncover intrinsic physical characteristics. However, its complex system and repetitive calibration requirements hinder edge applications. Here, we propose a compact, cost-effective, calibration-free SSI method, Aperture Diffraction Imaging Spectrometer (ADIS), which consists only of a diffractive lens with a binary mask and a Bayer-filtered sensor, requiring no additional physical footprint compared to standard RGB cameras. ADIS disperses and multiplexes wavelengths, mapping energy to distinct sensor locations, enabling full-resolution recovery from superpixel-level encodings. ADIS directly leverages theoretically computed PSFs to enable calibration-free spectral reconstruction, while tolerating lens-dependent variations across different optical configurations and bridging the gap between simulation and reality. To achieve SSI by solving a sparsely-constrained inverse problem, we introduce the Orthogonal Diffraction-Aware Unfolding Framework (ODAUF) with Voxel Shift Transformer (VST) for improved orthogonal diffraction perception. Integrating VST into ODAUF forms the efficient Orthogonal Diffraction-Aware Unfolding Voxel Shift Transformer (ODAUVST), delivering excellent recovery and reduced parameters. By elaborating on theory, systematic and comprehensive comparing, and demonstrating real SSI results, we validate the superiority of ADIS, achieving calibration-free full-resolution SSI within a commercial camera footprint.

0.25

Learned optical compression for single-pixel quantitative phase imaging

cs.CV physics.opticsphysics.app-ph ·2026-11-01 ·Ary Portes, Yuntian Wang, Che-Yung Shen, Shiqi Chen, Aydogan Ozcan
similarity 0.55
Abstract · 35 Pages, 11 Figures

Quantitative phase imaging (QPI) reveals optical path-length variations in transparent objects but typically relies on spatially resolved intensity measurements. Here we numerically and experimentally demonstrate learned optical compression for single-pixel QPI, jointly optimizing a diffractive encoder and a digital neural decoder to concentrate reconstruction-relevant phase information into a compact measurement vector. A single reconfigurable phase-modulation plane sequentially displays the learned encoding patterns, which are independent of the input object, each yielding one scalar intensity measurement. Operating at a visible wavelength, the experimental system reconstructs quantitative phase images of unknown objects with ~40-fold dimensional compression, using only 2.55% as many intensity measurements as reconstructed pixels. Experimental blind testing on handwritten digits and grating-like phase objects achieves mean Pearson correlation coefficients of 0.945 and 0.848, respectively. Benchmarking under the same measurement budget demonstrates substantially higher reconstruction fidelity than other encoding strategies, highlighting the advantages of learned optical compression. With the optical encoder fixed, decoder-only neural adaptation enables experimental transfer to previously unseen data distributions, extending the utility of the learned measurement representation. These results establish learned optical compression as a measurement-efficient and reusable framework for QPI, integrating phase-information compression into single-pixel intensity measurements while retaining adaptability to new data. This approach paves the way for low-data-rate phase imaging and sensing, with the potential to extend QPI to spectral regions where high-quality detector arrays are costly or unavailable.

0.29

RetiWave-Mamba: A Dual-Stream Network for Retinal Disease Detection based on Multi-scale Context and Feature-Adaptive Mamba Projection

cs.CV ·2026-08-18 ·Cheng Cheng, Jin Hong
published similarity 0.55
Abstract

Retinal diseases are a leading cause of irreversible vision impairment, making early and accurate diagnosis essential for effective treatment. Optical Coherence Tomography (OCT) serves as a critical imaging modality for this purpose, yet its automated analysis is hindered by inherent speckle noise, varying lesion scales, and subtle inter-class similarities. To address these challenges, we propose a novel framework, RetiWave-Mamba, which integrates spatial-frequency domain learning with state-of-the-art state space models. The framework utilizes Discrete Wavelet Transform (DWT) to decompose OCT images into low- and high-frequency streams, enabling decoupled processing of structural context and fine-grained details. For the low-frequency branch, we design a Multi-scale Contextual Localization Module (MCLM), which synergizes multi-scale dilation with spatial attention to expand the global receptive field and precisely localize lesion regions. For the high-frequency branch, we introduce an Attention-Guided High-Resolution Network (AG-HRNet) equipped with an intelligent gating mechanism to suppress noise propagation during multi-scale interactions. Furthermore, a Feature-Adaptive Mamba Projector (FAMP) is incorporated to form complementary channel-wise feature paths and adaptively reweight them using Mamba-generated gates. Extensive experiments on the OCT-C8 dataset demonstrate that our approach achieves a state-of-the-art (SOTA) classification accuracy of 98.38, surpassing existing methods. These results highlight the effectiveness of RetiWave-Mamba in identifying retinal pathologies and support its potential for computer-aided OCT image analysis.

0.30

Universal Drift Correction for Multidimensional Scanning Microscopy

cs.CV cond-mat.mtrl-sci ·2026-09-25 ·Sangjoon Lee, William Millsaps, Dasol Yoon, Caitlyn Obrero, Guoliang Hu +5 more
code/dataunusual similarity 0.54
Abstract

In scanning microscopy, drift causes the specimen to be sampled at positions displaced from the nominal probe positions. This displacement alters the spatial assignment of the recorded signals and biases quantitative measurements across two-dimensional imaging, channel-resolved spectroscopic mapping, and scan-position-resolved diffraction analysis. Here, we extend orthogonal-scan drift correction from 2D images to spectrum images and diffraction datasets. We demonstrate how to recover probe positions using either differently oriented multidimensional scans or structural reference images. The recovered positions are used either to resample the multidimensional data onto a regular grid or to assign each recorded signal to its corrected coordinate. Our method combines affine and non-rigid correction, requires no prior structural model, and is implemented as open-source, GPU-accelerated software that reduces processing times by two to three orders of magnitude, enabling routine and automated drift correction for quantitative multidimensional microscopy.

0.36

An Ultra-Widefield Swept-Source OCTA Dataset and a Polar-Gated Mamba Network for Retinal Vessel Segmentation

cs.CV ·2026-09-11 ·Yang Liu, Yibing Shen, Keming Zhao, Cenk Jiang, Zhenghang Qian +10 more
code/data similarity 0.54
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics. Under review

Ultra-widefield (UWF) swept-source optical coherence tomography angiography (SS-OCTA) enables large-area retinal vascular imaging, yet vessel segmentation at this scale lacks dedicated public benchmarks and comprehensive evaluation for quantitative vascular analysis. We introduce WOIVES, to our knowledge the first publicly available UWF SS-OCTA vessel-segmentation dataset, comprising 206 eyes from 152 participants with a 24x20mm^2 field of view. WOIVES spans emmetropia to high myopia and provides soft probability vessel annotations. We further propose PG-Mamba, a visual state space model that enhances conventional directional scans with two complementary polar-coordinate scan orders. An auxiliary Dynamic FOV Gating module performs spatial modulation at the bottleneck. PG-Mamba outperformed seven competitive approaches on broad segmentation metrics under cross-validation. It achieved the lowest median absolute errors for vessel density, fractal dimension, and vessel length density. WOIVES is publicly available on Zenodo (DOI: 10.5281/zenodo.21904672), and the PG-Mamba code is available at https://github.com/syb1234567/PG-Mamba.

0.36

Low-rank MERA Decomposition of 3D OCT Image Volume for Compression, Denoising, Feature Extraction and Diagnosis of Retinal Diseases

cs.CV ·2026-10-26 ·Ivica Kopriva, Fei Shi, Marija Štanfel, Qin Peng, Jianhao Bao +2 more
similarity 0.53
Abstract · 10 pages, 4 figures, 5 tables

Optical coherence tomography (OCT) is a non-invasive imaging modality used for visualization of retinal tissue. However, OCT volumes are affected by speckle noise, which degrades image contrast and obscures fine structural details. Furthermore, modern clinical practice requires large field-of-view, high-resolution OCT volumes, whose storage and transmission are demanding for archiving and teleophthalmology applications. To address aforementioned challenges, we propose a low-rank multi-scale entanglement renormalization ansatz (MERA) tensor network approximation of 3D OCT image volume, where the image volume is represented as contractions of a top core factor encoding global features and multiple interacting low-rank orthogonal or semi-orthogonal factors modeling inter- and intra-B scan correlations. This representation jointly enables compression, denoising, and feature extraction. Unlike deep learning approaches, the proposed approach is training-free and processes each OCT volume independently. We evaluate the proposed framework on OCT image volumes acquired by two different scanners and demonstrate improved visual quality and reduced retinal layer segmentation errors in comparison with several competing methods. We also extract MERA features from two clinical OCT volume datasets. They are subsequently classified using a Grassmann-manifold nearest-subspace classifier. With the subspace dimension as its only hyperparameter, the classifier is theoretically shown to be robust in small-sample clinical scenario. We demonstrate competitive accuracy of classification of retinal diseases in these small-sample settings, where deep learning methods are often limited by the scarcity of labeled data. The proposed structure-aware model-driven representation learning for high-dimensional data under limited supervision provides good generalization performance while maintaining high interpretability.

0.35