CS Paper Radar

Low-rank MERA Decomposition of 3D OCT Image Volume for Compression, Denoising, Feature Extraction and Diagnosis of Retinal Diseases

Ivica Kopriva, Fei Shi, Marija Štanfel, Qin Peng, Jianhao Bao, Gaowei Li, Xinjian Chen

cs.CV ·submitted 2026-10-26 11:45 UTC · v1

Abstract

Optical coherence tomography (OCT) is a non-invasive imaging modality used for visualization of retinal tissue. However, OCT volumes are affected by speckle noise, which degrades image contrast and obscures fine structural details. Furthermore, modern clinical practice requires large field-of-view, high-resolution OCT volumes, whose storage and transmission are demanding for archiving and teleophthalmology applications. To address aforementioned challenges, we propose a low-rank multi-scale entanglement renormalization ansatz (MERA) tensor network approximation of 3D OCT image volume, where the image volume is represented as contractions of a top core factor encoding global features and multiple interacting low-rank orthogonal or semi-orthogonal factors modeling inter- and intra-B scan correlations. This representation jointly enables compression, denoising, and feature extraction. Unlike deep learning approaches, the proposed approach is training-free and processes each OCT volume independently. We evaluate the proposed framework on OCT image volumes acquired by two different scanners and demonstrate improved visual quality and reduced retinal layer segmentation errors in comparison with several competing methods. We also extract MERA features from two clinical OCT volume datasets. They are subsequently classified using a Grassmann-manifold nearest-subspace classifier. With the subspace dimension as its only hyperparameter, the classifier is theoretically shown to be robust in small-sample clinical scenario. We demonstrate competitive accuracy of classification of retinal diseases in these small-sample settings, where deep learning methods are often limited by the scarcity of labeled data. The proposed structure-aware model-driven representation learning for high-dimensional data under limited supervision provides good generalization performance while maintaining high interpretability.

Comment
10 pages, 4 figures, 5 tables

Closest papers

Nearest neighbours by meaning across the whole index.

RetiWave-Mamba: A Dual-Stream Network for Retinal Disease Detection based on Multi-scale Context and Feature-Adaptive Mamba Projection

cs.CV ·2026-08-18 ·Cheng Cheng, Jin Hong
published similarity 0.66
Abstract

Retinal diseases are a leading cause of irreversible vision impairment, making early and accurate diagnosis essential for effective treatment. Optical Coherence Tomography (OCT) serves as a critical imaging modality for this purpose, yet its automated analysis is hindered by inherent speckle noise, varying lesion scales, and subtle inter-class similarities. To address these challenges, we propose a novel framework, RetiWave-Mamba, which integrates spatial-frequency domain learning with state-of-the-art state space models. The framework utilizes Discrete Wavelet Transform (DWT) to decompose OCT images into low- and high-frequency streams, enabling decoupled processing of structural context and fine-grained details. For the low-frequency branch, we design a Multi-scale Contextual Localization Module (MCLM), which synergizes multi-scale dilation with spatial attention to expand the global receptive field and precisely localize lesion regions. For the high-frequency branch, we introduce an Attention-Guided High-Resolution Network (AG-HRNet) equipped with an intelligent gating mechanism to suppress noise propagation during multi-scale interactions. Furthermore, a Feature-Adaptive Mamba Projector (FAMP) is incorporated to form complementary channel-wise feature paths and adaptively reweight them using Mamba-generated gates. Extensive experiments on the OCT-C8 dataset demonstrate that our approach achieves a state-of-the-art (SOTA) classification accuracy of 98.38, surpassing existing methods. These results highlight the effectiveness of RetiWave-Mamba in identifying retinal pathologies and support its potential for computer-aided OCT image analysis.

0.30

Learning Pathology-Sensitive Representations for Unsupervised Retinal OCT Anomaly Detection

cs.CV cs.LG ·2026-10-23 ·Tania Haghighi, Sina Gholami, Behafarin Emam, Jennifer I Lim, Theodore Leng +3 more
similarity 0.63
Abstract

Deep learning approaches for retinal optical coherence tomography (OCT) predominantly rely on predefined disease categories, limiting their ability to detect rare or previously unseen abnormalities. While visual foundation models provide transferable representations, their effectiveness in identifying pathological deviations from normal retinal anatomy remains insufficiently understood. In this work, we introduce an unsupervised framework for retinal OCT anomaly detection and localization that adapts pretrained visual representations to normal retinal anatomy through anatomy-aware reconstruction and contrastive triplet learning guided by synthetic structural perturbations, without requiring disease-specific annotations. We systematically investigate the influence of pretraining strategies, anatomy-aware representation adaptation, and anomaly scoring mechanisms on the detection and localization of unseen retinal abnormalities. Our findings demonstrate that adapting pretrained representations to normal retinal structure improves anomaly sensitivity, while pixel-space reconstruction errors and feature-space deviations provide complementary signals for identifying pathological changes. These findings underscore the importance of anatomy-aware representation learning and offer insights into developing generalizable retinal anomaly detection frameworks beyond predefined disease categories.

0.30

An Ultra-Widefield Swept-Source OCTA Dataset and a Polar-Gated Mamba Network for Retinal Vessel Segmentation

cs.CV ·2026-09-11 ·Yang Liu, Yibing Shen, Keming Zhao, Cenk Jiang, Zhenghang Qian +10 more
code/data similarity 0.63
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics. Under review

Ultra-widefield (UWF) swept-source optical coherence tomography angiography (SS-OCTA) enables large-area retinal vascular imaging, yet vessel segmentation at this scale lacks dedicated public benchmarks and comprehensive evaluation for quantitative vascular analysis. We introduce WOIVES, to our knowledge the first publicly available UWF SS-OCTA vessel-segmentation dataset, comprising 206 eyes from 152 participants with a 24x20mm^2 field of view. WOIVES spans emmetropia to high myopia and provides soft probability vessel annotations. We further propose PG-Mamba, a visual state space model that enhances conventional directional scans with two complementary polar-coordinate scan orders. An auxiliary Dynamic FOV Gating module performs spatial modulation at the bottleneck. PG-Mamba outperformed seven competitive approaches on broad segmentation metrics under cross-validation. It achieved the lowest median absolute errors for vessel density, fractal dimension, and vessel length density. WOIVES is publicly available on Zenodo (DOI: 10.5281/zenodo.21904672), and the PG-Mamba code is available at https://github.com/syb1234567/PG-Mamba.

0.36

Differentiable Inverse Rendering Recovers Intrinsic Properties from Intravascular Optical Coherence Tomography

cs.CV eess.IVphysics.med-phphysics.optics ·2026-11-09 ·Ajay Manicka, Karim Kadry, Sebastian Ruiz-Lopera, Maryam Alsharqi, Sanjana Arji +5 more
similarity 0.62
Abstract · 27 Pages, 6 Figures, Under Review

Medical images encode intrinsic tissue properties that indicate disease progression, yet these properties remain entangled with the system-dependent physics of image formation. Differentiable inverse rendering asks whether they are recoverable by inverting the imaging system's forward physics rather than through post-hoc correction. We address this in optical coherence tomography (OCT), focusing on the optical attenuation coefficient, a per-pixel marker of pathology and cellular composition. Conventional recovery relies on closed-form inversions limited to simplified light-tissue models, or learned methods coupled to specific imaging configurations. We instead recover per-pixel attenuation from a single OCT image by gradient descent through a differentiable physics-based forward model. We verified the method against analytical solutions, validated it on five in vitro phantoms, and applied it without modification to 29{,}269 clinical intravascular OCT images from 128 patients. The inversion needs no training data or segmentations and is portable across platforms and retrospective archives. Replacing the forward model or recovering another optical parameter leaves the optimization procedure unchanged. We demonstrate per-pixel recovery is tractable because gradient information scales to this high-dimensional problem, where gradient-free methods become intractable. Our work supports quantitative tissue characterization from OCT images and provides a framework for extension across imaging modalities and organ systems.

0.26

Compression of Vision Foundation Models for Retinal OCT via Growing-Neural-Gas Codebooks and Graph-Guided Masked Image Modeling

cs.CV ·2026-10-23 ·Ali Yavari, Tilman Schmoll, Rainer A. Leitgeb, Wolfgang Drexler, Thomas Schlegl
benchmarkhot direction similarity 0.61
Abstract · 31 pages, 2 figures, 8 tables; supplementary material provided as an ancillary file

Vision foundation models for retinal imaging are large and computationally demanding, limiting point-of-care deployment. We ask how much of such a model's downstream utility survives compression into a smaller network. We propose a topology-aware discretization framework that distills a continuous foundation model into a discrete codebook, then uses it as the reconstruction target for masked image modeling (MIM). It combines gradient-free codebook learning via Growing Neural Gas, which yields an adjacency graph over the codes, with a graph-distance soft cross-entropy loss that replaces one-hot MIM targets with topologically graded supervision. With student pretraining on 383 public Duke iAMD optical coherence tomography (OCT) volumes, the pipeline distills an 86M-parameter teacher into a 22M-parameter student with at least 3.6x fewer FLOPs. The student performs close to, and in some settings above, its teacher across three classification and two segmentation benchmarks, with the magnitude and direction of the difference depending on the teacher, task, metric, and student capacity. On the external OLIVES benchmark, it surpasses its MIRAGE teacher on every metric (98.06% vs. 95.22% balanced accuracy). It works with two Vision Transformer (ViT-Base) teachers, retinal (MIRAGE) and natural-image (DINOv3); with the out-of-domain teacher, the student outperforms it on retinal-layer segmentation, indicating that the added value of retina-specific pretraining is task-dependent: largest for segmentation, while a general-domain teacher is competitive for classification. These results yield compact retinal models potentially suitable for deployment, transferring across OCT datasets, devices, and clinical tasks, including three datasets not used in the student's pretraining.

0.36

CNN-Based Retinal OCT Classification: Research Gap Analysis and a From-Scratch Baseline, ED126-A

cs.CV cs.LG ·2026-11-01 ·Shkelqim Sherifi
benchmark similarity 0.60
Abstract · 18 pages, 26 figures

Automated classification of retinal pathologies from Optical Coherence Tomography (OCT) images remains challenging because diagnostically relevant morphological patterns may exhibit substantial inter-class similarity. Although high classification accuracies have been reported on benchmark OCT datasets, cross-study comparison is limited by heterogeneous evaluation protocols and by the limited characterization of compact convolutional neural network (CNN) baselines trained from random initialization. This study addresses this gap through two contributions. First, it provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled benchmarking. Second, it presents ED126-A, a purpose-built four-class CNN baseline trained from scratch under a documented experimental protocol on the Kermany labeled OCT dataset. The model contains 1,241,380 total parameters, including 1,239,460 trainable parameters, and is evaluated using training-dynamics analysis, class-wise performance metrics, confusion-matrix analysis, confidence analysis, t-SNE representation-space visualization, Grad-CAM, hierarchical feature-map analysis, and one-vs-rest ROC/Precision-Recall analysis. On the image-level held-out test set, ED126-A achieved 95.03% accuracy, with a macro-F1 of 0.9205 and a weighted-F1 of 0.9521. The principal class-conditional limitation occurred for Drusen, which attained a recall of 0.9605 but a precision of 0.7493 and an F1-score of 0.8419. The confusion matrix identified Normal to Drusen and CNV to Drusen as major error channels. These results support the use of ED126-A as a documented from-scratch reference baseline and provide an empirical basis for controlled evaluation of transfer learning, increased depth, attention, multi-scale feature fusion, and calibration in subsequent studies.

0.30

Within-Family EfficientNet Scaling under Fixed-Resolution Transfer Learning for Spectral-Domain Optical Coherence Tomography Retinal Disease Classification

cs.CV cs.AIcs.LG ·2026-11-04 ·Shkelqim Sherifi
similarity 0.60
Abstract · 46 pages, 20 figures, 18 tables

Background/Objectives: CNNs perform well in retinal disease classification from spectral-domain optical coherence tomography (SD-OCT), but whether EfficientNet's natural-image scaling hierarchy transfers to medical-image transfer learning at fixed resolution remains unclear. This study evaluates EfficientNet-B0-B7 for four-class SD-OCT classification and accuracy-efficiency trade-offs. Methods: Eight ImageNet-pretrained variants (4.05-64.10M instantiated backbone parameters) were evaluated at 224x224 on the Kermany dataset. Grayscale images were replicated to RGB and processed using model-embedded preprocessing and augmentation. Training comprised frozen-backbone head training followed by partial fine-tuning. Metrics covered classification, discrimination, efficiency, and visual analyses. Results: Test accuracy varied non-monotonically from 95.93% (B0) to 96.95% (B1); B7 achieved 96.73%. B1 had the highest accuracy and Drusen F1 (0.8780), while B7 had Drusen F1 of 0.8720 and the highest Drusen recall (0.9177). Drusen had the lowest F1 across all variants and contributed 82.2% of the summed squared deviation in class-specific F1; class ranking remained Normal > CNV > DME > Drusen. The OCT accuracy ranking differed from the reported ImageNet hierarchy, where B7 ranked first. The accuracy-to-parameter ratio fell from 19.82 to 1.48 percentage points per million total parameters. The final train-test gap had a weak, non-significant association with test accuracy (r = 0.26, p = 0.53). Conclusions: Larger EfficientNet variants did not consistently improve SD-OCT classification. B1 achieved the highest accuracy and Drusen F1, whereas B7 showed a secondary accuracy recovery at greater model size and CPU latency, indicating task and protocol dependent scaling effects. As cross-partition duplicates have not been independently audited, results are conditional on the supplied split.

0.13

RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM

cs.CV cs.LG ·2026-11-09 ·Jaafar M. Al-Ghabban, Mohammad Reza Mohammadi
similarity 0.59
Abstract

Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.

0.25