CS Paper Radar

Daily listing

2026-10-21 · eess.IV

9 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 9

Rethinking Video Storage for AI Training: Breaking Cross-Frame Dependencies for Efficient Random Access

cs.CV eess.IV ·2026-10-21 ·Zetian Song, Qize Yu, Yue Chen, Bohan Zhou, Bowen Ping +8 more
code/data
Abstract · 18 pages, including supplementary material. Project page: https://skywalker-yqz.github.io/codec4AI/ Code: https://github.com/kaname-madoka18…

Large-scale AI training increasingly relies on massive video datasets with random temporal sampling patterns. However, existing video storage paradigms are optimized for sequential playback and employ sophisticated inter-frame reference structures to maximize compression efficiency. When applied to the random-sampling workloads of AI training, these paradigms face substantial decoding-efficiency bottlenecks. Workarounds such as independent JPEG frames and short groups of pictures (GOPs) reduce decoding work at the cost of larger storage and transfer volumes. In this paper, we identify two sources of decode amplification: sequential reconstruction of unrelated frames and reconstruction of the reference chains required by sampled targets. We address both sources by co-designing the decoding schedule and video reference structure. Dependency-aware sparse decoding reconstructs only requested frames and their required references, skipping unrelated reconstruction without transcoding the source videos. Optional offline Dependency-Decoupled Random Access (DDRA) encoding further reduces reference reconstruction by restricting each interior frame to two bounding intra-coded anchors. Together, sparse decoding and DDRA retain inter-frame prediction while bounding reconstruction to at most three frames per requested target, independent of the intra period. Experiments on a large-scale robotics corpus show that, at comparable reconstruction quality, our method achieves $1.45\times$ the loading throughput of LeRobot v3 with 58.7% less media payload.

0.45

AVAtt: A Free-Viewing Eye-Tracking Dataset and Benchmark for Visual Attention on Paintings

cs.CV cs.HCeess.IV ·2026-10-21 ·Mohamed Amine Kerkouri, Marouane Tliba, Aladine Chetouani, Alessandro Bruno
publishedbenchmarkdatasetcode/data
Abstract · Extenstion of 10.1145/3649902.3655656 published at ETRA 2024

Saliency and scanpath models are developed almost exclusively on natural photographs, yet paintings are composed by artists to guide the viewer's eye and differ from photographs in texture, colour and abstraction. We introduce \avatt, a free-viewing eye-tracking dataset on \nImages{} paintings spanning sixteen art movements and five centuries, with \nScanpaths{} scanpaths and \nFixations{} fixations from \nParticipants{} participants (\spPerImageMin--\spPerImageMax{} observers per painting). For every painting we release individual scanpaths with fixation timing and eye--screen distance, fixation maps, saliency maps smoothed at one degree of visual angle, temporal saliency videos and rich art metadata. We benchmark classic and deep saliency models against human agreement, revealing substantial headroom for art-aware models, and rank 44 scanpath-similarity measures, including a new language-free family of image-encoder metrics built on ten CNN, ViT and self-supervised encoders. With controls that remove viewing biases, we show that faces are fixated \faceEnrich$\times$ more than expected and within half a second, that local structure draws the eye, that composition rules fitted from image content predict where people look, and that art style shapes how much viewers agree. Dataset, code and a Python package are available at: https://huggingface.co/datasets/Amine-CV/AVAtt.

0.42

TernScope: Model-Hardware Co-Design for Efficient Ternary Endoscopic Segmentation

eess.IV cs.ARcs.CV ·2026-10-21 ·Zhuoyu Wu, Wenhui Ou, Qiawei Zheng, Xuhong Qiu, Wenqi Fang +1 more
code/data
Abstract · 5 pages, 4 figures, 3 tables. Code and experimental results: https://github.com/ReaganWu/TernScope

Edge medical segmentation must reconcile small model size, high accuracy, and fast inference. TernScope addresses this tradeoff through model--hardware co-design, learning a compact segmentation network whose low-bit operators also simplify hardware execution. Split-channel large-kernel blocks preserve spatial context with limited computation, while branch fusion removes redundant inference paths. Ternary Progressive Quantization-aware Training (TPQ) then adapts the fused network from deep to shallow layers, through the decoder, and finally to the input and prediction layers. All 25 convolutions use ternary weights and 8-bit activations, enabling packed storage and multiplier-free computation. The resulting model uses 0.2483 M parameters and 0.0949 GMACs while retaining competitive segmentation accuracy on in-domain and external datasets. Under the same 45 nm technology, TernScope reduces compute-array area by 88.46% compared with the original Gemmini, a systolic-array accelerator with 8-bit $\times$ 8-bit multipliers. These results demonstrate a path from accurate lightweight medical segmentation to compact low-bit hardware.

0.39

Region-Aware Multi-View Inspection Using Deep Learning and Domain-Informed Decision Fusion

cs.CV cs.LGeess.IV ·2026-10-21 ·Srivishnu Ethirajulu Krishnaraj, Rishikesh R. Chopade
Abstract · 10 pages, 4 figures, 10 tables

Automated optical inspection of precision components with tiny surface defects remains challenging when different regions of the same component exhibit different defect characteristics and, therefore, different acceptance criteria. This paper presents a region-aware, dual-model inspection framework that combines instance segmentation of localized seat-region defects with image-level classification of global shaft-region anomalies. Rather than treating these two model detections as sufficient evidence for component rejection, a deterministic decision fusion layer that formalizes industrial Standard Operating Procedures is applied to the model outputs to make the final component level decision. A PLC-synchronized imaging system acquires 18 seat and 18 shaft images over a full 360-degree rotation to provide multi-view circumferential coverage. The framework was evaluated on 380 automotive fuel injector needles, covering representative operational defect types, using identical model predictions in all configurations. Direct model-output aggregation via simple union logic (where any single-view detection flags a rejection) identified all 104 non-conforming components but produced a component level false rejection rate of 57.6%. Inclusion of a complete decision layer maintained the observed non-conforming (NOK) recall of 100% while reducing the false rejection rate to 10.9%, corresponding to an 81.1% reduction in false-positive component decisions. The results demonstrate that formalized manufacturing acceptance criteria can complement sensitive visual models by translating frame-level detections into practical and traceable component-level decisions.

0.27

Geometric Algebra for Neural Networks: A Survey

eess.IV stat.ML ·2026-10-21 ·Tao Zhong, Kaison Fong, Keqin Wang, Christine Allen-Blanchette
surveyunusual
Abstract · 38 pages, 5 figures

Geometric algebra (GA) unifies geometric primitives and transformations in a single algebraic framework. Neural networks designed around this framework often represent features as multivectors and constrain layer operations to respect the algebraic structure, enabling principled treatment of geometric transformations and, in many cases, built-in equivariance. This survey reviews geometric algebra neural networks, including their building blocks, equivariant properties, application domains, empirical performance, and software support. We provide an algebra-selection guide, an empirical comparison of GA-based and other equivariant architectures, and a failure-mode analysis covering training pathologies, deployment constraints, and performance limitations. Across the surveyed literature, the strongest evidence for GA-based architectures appears in settings with explicit geometric symmetries and heterogeneous geometric entities; evidence for broader advantages in parameter efficiency, interpretability, and dense prediction is comparatively limited and uneven. We therefore conclude that geometric algebra neural networks are not universally superior to well-tuned non-GA equivariant baselines, and outline open problems in algebra selection, numerical stability, scalable implementation, and reproducible evaluation.

0.27

Unified Projection-Domain Material Decomposition for Energy-Integrating and Photon-Counting CT

eess.IV physics.med-ph ·2026-10-21 ·Dale Black, Surya Naidu, Hamidreza Khodajou-Chokami, Sabee Molloi
theory
Abstract · 27 pages, 10 figures, 6 tables

Objective: To develop a unified and efficient method for projection-domain material decomposition in spectral computed tomography (CT) that incorporates an arbitrary number of spectral measurements, independent of the acquisition mechanism, without reducing the measurements to two effective energies. Approach: A nested optimization method was developed for two-material basis decomposition from K>=2 spectral measurements. It extends an existing two-measurement univariate method by replacing its polynomial approximation with profile minimization of the Poisson negative log-likelihood, reducing the inversion to two one-dimensional searches that use all measurements without spectral rebinning. The method was evaluated in simulation for energy-integrating (GE Revolution Apex Elite, Siemens SOMATOM Flash) and photon-counting (Siemens NAEOTOM Alpha) CT. Main results: The method recovered line integrals with noiseless iodine errors below 3e-6 g/cm^2 and noise within 3% of the Cramer-Rao lower bound (CRLB). Virtual monoenergetic images (VMIs) agreed, at 70 keV and above, with reference CT numbers and, on all three systems, with vendor VMIs of physical scans (mean absolute error 6-22 HU). For photon counting, four measurements instead of two reduced the iodine CRLB by 19% and image noise by 8-16% at every VMI energy, and lowered the regression error at 70 keV and above. Iteration and tolerance settings changed CT numbers by less than 0.04 HU, and decomposition took 0.34-0.67 s per million rays on an A100 GPU. Significance: The method provides fast, accurate decomposition for any spectral CT acquisition mechanism and number of measurements, so one method can serve every scanner in a virtual imaging trial.

0.25

A Contrastive Learning Framework for Label-Efficient Gastric Cancer Detection and Intra-Tumour Progression Analysis

eess.IV ·2026-10-21 ·Aleakhya Pandeti, Pranav M. Pawar, Mithun Mukherjee, Raja Muthalagu
Abstract · 20 pages, 11 figures

Gastric Cancer is among the leading causes of cancer-related mortality worldwide. The complexity and variability of histopathological images pose significant challenges for both pathologists and computer-based diagnostics, creating a growing need for machine learning approaches capable of capturing meaningful representations from limited labelled data. Selfsupervised Contrastive Learning (CL) has demonstrated promising results in natural image analysis; however, its application to gastric cancer histopathology remains underexplored. This paper proposes an integrated CL framework built on a ResNet50 encoder trained under the NT-Xent objective, without reliance on ImageNet pre-training, to learn discriminative and staining-invariant representations from H&E-stained tissue patches. The learned embeddings are transferred to a supervised downstream classifier for binary tumour/normal (TUM/NOR) detection, achieving a test accuracy of 83.13%, an AUC-ROC of 0.9087, and an Average Precision of 0.9063 - competitive with recent supervised and weakly-supervised approaches on comparable histopathology benchmarks. Beyond binary diagnosis, the framework applies K-Means clustering to tumour embeddings to identify four geometrically separable pseudo-stage clusters, confirmed by a Random Forest classifier achieving 97% accuracy and a mean Dice coefficient of 0.97, demonstrating the capacity of CL representations to encode progression-relevant morphological variation without stage-level annotations. Grad-CAM explainability is integrated throughout to ensure model transparency. The complete system is deployed via a Streamlit clinical interface. Compared to recent state-of-the-art methods the proposed framework operates with substantially fewer labelled samples while additionally providing unsupervised progression stratification and interpretable outputs, addressing a gap not covered by existing approaches.

0.24

Equivariant Experience Replay for Continual Learning in Imaging Inverse Problems

eess.IV ·2026-10-21 ·Guixian Xu, Jin Zhu, Jinglai Li, Junqi Tang
Abstract · 16 pages

In this work, we propose Equivariant Experience Replay, a new paradigm for achieving continual learning of deep networks for solving ill-posed imaging inverse problems. Inspired by recent advances on unsupervised learning methods such as equivariant imaging/splitting, we find the exploitation of group-symmetry structure is particularly relevant and effective in continual learning setting for ill-posed inversion tasks. We therefore propose this new experience replay scheme, which is tailored for such inverse problems. Our numerical study demonstrates the superiority of our method compared to existing continual learning methods for inverse problems in medical imaging and image processing.

0.22

SciFusion: Physics-Guided Compositional Diffusion for Multimodal 3D Scientific Image Generation

eess.IV cs.LG ·2026-10-21 ·Luoxi Wang, Alessio Quercia, Hanno Scharr, Arya Bangun
Abstract

Existing 3D generative approaches are typically developed for individual imaging modalities, requiring substantial modality-specific data and limiting their ability to exploit shared structure across scientific imaging domains. We present SciFusion, a multimodal framework for unified 3D scientific image generation built on a latent diffusion backbone, with two key contributions. First, we introduce a compositional conditioning scheme that factorizes each modality into domain, object, and contrast representations. Sharing these factors across related modalities enables knowledge transfer across heterogeneous imaging domains and allows the factors to be recombined at inference time to synthesize unseen domain-object-contrast compositions in a zero-shot manner. Second, we incorporate domain-specific physics-informed objectives: Fourier spectral consistency for MRI, Radon projection consistency for CT, and multislice diffraction consistency for electron microscopy, to encourage generated samples to respect modality-dependent image formation processes. Extensive experiments across 15 medical and scientific imaging modalities demonstrate that SciFusion improves generation fidelity and cross-domain generalization over modality-specific and flattened multimodal conditioning strategies, while enabling zero-shot synthesis of unseen compositions without training on those target compositions. These results demonstrate that compositional, physics-guided conditioning provides a scalable framework for unified 3D scientific image generation, particularly for emerging modalities where large-scale training data are difficult to obtain.

0.19