CS Paper Radar

Daily listing

2026-10-23 · eess.IV

8 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 8

An exploration of plug-and-play flow matching for full-waveform inversion on breast imaging

eess.IV math.NA ·2026-10-23 ·Cristina Garcia-Cardona, Siting Liu, Fatma Terzioglu, Shanyin Tong, Lu Zhang
Abstract

Full-waveform inversion (FWI) reconstructs sound-speed fields from measured waveforms, by solving an optimization problem that minimizes the discrepancy between measured waveforms and those predicted by a numerical wave-propagation model. However, choosing suitable regularization for this optimization is challenging because it must stabilize the inversion while preserving relevant structures, prompting us to investigate whether priors learned from representative sound-speed images can improve reconstruction. In this work, we adapt plug-and-play flow matching (PnP-Flow) to FWI by alternating waveform-misfit updates with updates from a pretrained flow prior. We explore the effectiveness of PnP-Flow reconstruction by comparing it with total-variation (TV) regularization using noiseless transmission-only plane-wave data. Separate flow priors are trained on two circular-inclusion model families with constant and spatially varying backgrounds. We evaluate the method both on these in-distribution circle models and under substantial distribution shift by transferring the Gaussian-circle prior and reconstruction settings to breast phantom patches without retraining or retuning. Using the same number of waveform-misfit updates, the proposed PnP-Flow framework generally improves circle reconstruction accuracy and recovers breast lesion contrast more accurately than TV baselines.

0.32

Investigating the trackability of landmarks in NBI and WLI

eess.IV cs.CV ·2026-10-23 ·Jonas Below, Piermarco Gerli, Anna Jötten, Dennis Eggert, Axelle Felicio-Briegel +3 more
Abstract · Accecpted at CURAC conference 2026

Reliable visual tracking of anatomical landmarks in endoscopic video is a key prerequisite for computer-assisted interventions in laryngeal surgery. While Narrow Band Imaging (NBI) is clinically established for enhancing vascular contrast, its effect on automated tracking relative to conventional White Light Imaging (WLI) remains unexplored. We present a quantitative comparison of landmark trackability in NBI and WLI using a forward-backward error framework applied to 61 endoscopic videos from 39 patients. Two regions of interest are evaluated: the vocal folds (VF) and mucosa with a prominent vascular pattern (MPVP). We compare a classical feature-based tracker (CSRT) against learning-based point trackers (CoTracker3-Online and TrackOnR) across both modalities. NBI consistently reduced the forward-backward error in both regions, reaching statistical significance for the vocal folds, while failure rates stayed low. These findings indicate that NBI can improve tracking robustness in laryngeal endoscopy, with implications for motion analysis, navigation, and robotic assistance.

0.24

IAR: An Interaction-Aware Approach to Post-Seek Recovery in Adaptive HLS Streaming

eess.IV cs.MM ·2026-10-23 ·Mahdi Naseri Majd, Amirfarhad Farhadi
unusual
Abstract

After an unbuffered seek, an adaptive bitrate (ABR) player has little forward buffer at the new position, while its controller may retain a bandwidth estimate from earlier downloads. An expensive first request can delay resumption; later requests may interrupt playback while the buffer rebuilds. We introduce Interaction-Aware Recovery (IAR), a temporary layer around the hls.js ABR controller. After an unbuffered seek, IAR discounts the inherited estimate (γ=0.15) to set a representation ceiling. Normal adaptation continues below it until 8 s of forward buffer has been rebuilt. In a 200-run paired study spanning four network profiles, ten seek positions, and five strategies, a conservative first request reduced resume delay by a paired median of 2.008 s relative to standard hls.js. Keeping a low ceiling through recovery reduced later interruption under stronger degradation but lowered early presented bitrate. IAR and Fixed-Low-Recovery both used L0 in this campaign, so the results did not show an additional benefit from deriving the ceiling from inherited bandwidth. In 60 additional runs under a fixed Moderate profile, we reset the estimator to six controlled scalar priors. IAR's ceiling changed from L0 to L1 and L2 at the predicted thresholds. Resume and recovery times increased at those transitions; presented bitrate varied non-monotonically and was highest at L2. No stalls occurred. These reset-created priors do not reproduce complete, naturally evolved exponentially weighted moving average (EWMA) histories. The results show the benefits and presented-quality costs of conservative post-seek recovery, without establishing an advantage for a history-derived ceiling over a fixed low ceiling.

0.24

Fully-Automated Multi-Modal Registration of Timelapse Zebrafish OCT+LS Images

eess.IV ·2026-10-23 ·Mahshid Babeli Nia, Leah A. Lewis, Mohammad Mobarak Karim, Manmohan Singh, Arne C. Lekven +3 more
Abstract

Optical coherence tomography (OCT) and light sheet (LS) fluorescence microscopy provide complementary views of tissue morphology and molecular expression, offering a powerful approach for studying embryonic development. However, longitudinal integration of OCT+LS images is challenging because the modalities differ substantially in contrast, spatial resolution, field of view, and visible anatomical features, while embryo growth and movement introduce additional misalignment over time. These challenges stem from both the scale and multimodal nature of the OCT and LS image stacks. We present a fully automated three-dimensional rigid registration framework for aligning OCT and LS volumes of developing zebrafish embryos acquired from 21 to 48 hours post fertilization (HPF). The method does not require pre-existing segmentations or cross-modal feature correspondences, which are often unreliable because OCT and LS capture fundamentally different tissue properties. Registration performance was evaluated across developmental time points using mean target registration error (mTRE) and compared across multiple similarity metrics and optimization methods. Normalized cross-correlation combined with particle swarm optimization produced the most accurate and consistent registration, achieving the lowest mTRE at every evaluated time point compared with the alternative methods. The registration establishes spatial correspondence between OCT tissue morphology and LS fluorescence signals throughout development, enabling integrated longitudinal analysis of structural and molecular changes in living embryos.

0.23

Real Time Motion Detection in Video Inspired by Photonic Time Stretch

cs.CV eess.IVphysics.optics ·2026-10-23 ·Callen MacPhee, Yiming Zhou, Bahram Jalali
Abstract

Motion perception is fundamental to computer vision and physical AI, and plays a central role in robotics, autonomous vehicles, human-computer interaction, and video compression. Traditional approaches such as background subtraction, frame-differencing and optical flow algorithms often struggle in complex or dynamic scenes, typically sacrificing spatial resolution for computational tractability. Here we introduce MoViD (Motion estimation via Virtual dispersion and phase Detection), a physics-inspired algorithm grounded in the principles that govern photonic time stretch - a highly successful ultrafast realtime data acquisition platform. Drawing inspiration from the optical physics therein, MoViD treats video as a collection of optical time series waveforms associated with pixels. Motion of an object through a pixel broadens the time series spectrum and, after group delay dispersion, induces a temporal phase that exists only if there is motion. Spatiotemporal group delay dispersion templates, corresponding to dielectric functions, classify specific motion trajectories. Unlike conventional empirical phase-based motion-analysis pipelines that require narrow-band spatial channelization and pyramid reconstruction, the physics-based MoViD operates directly on the broadband video signal, vastly increasing its computational speed. The resulting algorithm achieves unprecedented performance in both motion characterization and motion magnification, providing full-resolution motion mapping in real time at nearly 200 frames per second at 4K resolution and 70 frames per second for 8K video - orders of magnitude faster than classical optical flow approaches or learning-based methods. Notably, such extreme performance enables real time motion analysis at ultrahigh resolution for motion detection and compensation in robotics and other autonomous devices.

0.22

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

eess.IV cs.CV ·2026-10-23 ·Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian +10 more
Abstract · 36 pages, 7 main figures, 2 supplementary figures. Under review at Medical Image Analysis

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

0.21

Matching Particle-Arrival Rates for Low-Count Image Denoising

eess.IV cs.CV ·2026-10-23 ·Huazhen Liu, Zipei Yan, Jizhou Li
Abstract

Low-count imaging arises when limited illumination or dose yields only a few detected particles in microscopy, such as photons or electrons, causing measurements to be dominated by signal-dependent Poisson shot noise. Supervised denoisers typically require paired clean and noisy observations, whereas many self-supervised approaches exploit spatial or temporal redundancy without directly estimating the underlying particle-arrival process. We introduce PARM, a self-supervised denoising framework based on particle-arrival-rate matching. By modeling particle accumulation over exposure as a Poisson counting process, PARM identifies the conditional particle-arrival-rate field with the posterior mean of the latent clean rate. Poisson thinning then splits each observation into complementary lower-exposure views that provide self-supervised rate targets for one another. In implementation, the network estimates the normalized spatial allocation of the conditional rate, while the observed total count determines its global particle mass. Experiments on synthetic data, natural-video sequences corrupted with Poisson noise, and real low-dose electron microscopy demonstrate leading or competitive performance while effectively preserving fine structures. PARM therefore provides a statistically grounded approach to low-count image denoising when clean references are unavailable.

0.19

Beyond Visible Speakers: Context-Aware Active Speaker Detection with Speaker Registration

cs.SD cs.CVcs.MMeess.AS+1 ·2026-10-23 ·Pu Wang, Hugo Van hamme
Abstract · Submitted to IEEE ICASSP 2027

Active speaker detection (ASD) relies on audiovisual correspondence between speech and visible faces, yet this correspondence becomes unreliable in crowded scenes, or when visual evidence is unavailable. We introduce ROAM-ASD-C and ROAM-ASD-CR to extend ROAM-ASD with contextual and identity-aware reasoning. ROAM-ASD-C jointly reasons across simultaneously visible candidates, allowing other faces to provide complementary evidence when the target observation is ambiguous or incomplete. ROAM-ASD-CR incorporates registered-speaker representations derived from enrollment speech, allowing detection of whether a speaker is active even when that speaker is not visually observed. ROAM-ASD-C achieves state-of-the-art performance across five ASD benchmarks: 96.8% mAP on AVA, 98.9% on WASD, 88.8% on UniTalk, 98.7% on Talkies, and 99.5% on ASW. It also improves ROAM-ASD by up to 13.3 mAP under 75% target-track visual removal.

0.07