CS Paper Radar

Daily listing

2026-11-01 · eess.IV

6 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 6

OpenULF: A Modular Toolkit Enables Data-Driven Ultra-Low-Field MRI with both Classical and Quantum Sensors

eess.IV cs.CVphysics.med-ph ·2026-11-01 ·Hanhan Wu, Yuchen Yuan, Weiwen Jiang
publishedcode/data
Abstract · 8 pages, 6 figures, 3 tables. Accepted for publication in the 44th IEEE International Conference on Computer Design (ICCD 2026). Code availa…

Ultra-low-field (ULF) Magnetic Resonance Imaging (MRI) offers a portable, low-cost alternative to conventional scanners by operating at field strengths below 10 mT. At these fields, two sensor technologies compete: quantum SQUID (Superconducting Quantum Interference Device) sensors, which provide high sensitivity but require cryogenic cooling, and classical induction coils, which are inexpensive and room-temperature but produce weaker signals. With conventional physics-based imaging, both suffer from low signal-to-noise ratios (SNR). Data-driven reconstruction has overcome similar limits in related inverse problems, but its use for ULF-MRI has been hindered by a lack of open datasets, benchmarks, and flexible simulators. To close this gap, we present OpenULF, a modular, open-source simulation toolkit that generates paired training data and supports end-to-end machine-learning (ML) reconstruction. OpenULF integrates a Bloch-equation-validated physics simulator, calibrated SQUID and coil receiver models, reconstruction ML networks, and an automated design-space exploration engine. Architecturally, a receiver abstract base class, a typed HDF5 contract that decouples physics from learning, and a resumable sweep engine make sensors, models, and datasets independently substitutable. Using OpenULF, we train 774 models across four anatomical datasets and conduct three design-space explorations. The effectiveness of ML reconstruction depends strongly on the dataset and the sensor. We identify a SQUID-to-coil crossover near 450 $μ$T and demonstrate that sensor hardware and ML model capacity can be traded off during system design. Sensor and reconstruction choices must therefore be co-designed: the best sensor is set by the dataset and field strength, not by SNR.

0.48

Cross-Dataset Generalization of Glaucoma Detection CNNs: Effects of Operating Threshold, Multi-Source Training, and Color Normalization

eess.IV cs.CV ·2026-11-01 ·Al-Amin Rahman, Saifuddin Ahmed, Resalat Ahmed
Abstract · 17 pages, 10 figures, 11 tables

Deep learning models for glaucoma detection are usually tested on images from the same dataset used for training. That says little about how they will work at a new hospital or with a new camera. We fine-tuned five ImageNet-pretrained CNNs (ResNet50, DenseNet121, MobileNetV2, EfficientNet-B0, InceptionV3) with identical settings on one of three public fundus datasets (ACRIMA, ORIGA, RIM-ONE DL). Each was tested on a held-out part of its own dataset and on the other two datasets in full. We used three random seeds and report mean and SD over seeds. Mean in-domain AUC was 0.913 and cross-source AUC was 0.702, a drop of 0.211 (SD 0.030; 95% CI 0.135 to 0.286). After correction for multiple comparisons we found no evidence that any architecture did better, though three seeds give low power. At thresholds set on the source validation data, specificity fell from 0.870 to 0.506 and sensitivity from 0.831 to 0.726. Resetting the threshold on 10% of the target images raised specificity to 0.670 but lowered sensitivity to 0.609, and balanced accuracy rose only from 0.616 to 0.639. Training on two sources together did not help (held-out AUC 0.695 versus 0.702). LAB reference normalization (cross-source AUC 0.755) and strong color augmentation (0.754) gave similar gains, cutting the drop to about 0.16. Ben Graham normalization (0.733) and CLAHE (0.712) helped less, and gray-world (0.696) did not help. The two best methods raised specificity but lowered sensitivity. On G1020, used only for testing, AUC stayed near 0.5 in every condition, and networks trained within G1020 were also close to chance. Strong in-domain results do not show that a glaucoma model will work on new data. Normalization and color augmentation reduce the drop but do not remove it. Studies should report external validation and check the operating threshold, not only AUC.

0.35

Resampling-based batch reweighting for ComBat harmonization of MRI radiomic features in a multi-scanner glioma cohort

eess.IV physics.med-ph ·2026-11-01 ·Rifa Sajda Tasnim, Yushuf Sharker, Md Forhad Hossain, Rakibur Rahman, Enamul Hoque Bhuiyan
published
Abstract · Original article. Submitted to Journal of Magnetic Resonance Imaging (JMRI)

Radiomic features derived from magnetic resonance imaging (MRI) are sensitive to scanners; therefore, they require harmonization across scanners. In a radiomic feature dataset, some batches may be severely underrepresented compared to the others e.g., the Erasmus Glioma Database, which may provide harmonized features biased towards the larger batches in the dataset. We investigated whether reweighting underrepresented scanner batches before empirical-Bayes ComBat estimation improves feature harmonization and reduces residual scanner association while retaining grade-related information. In this retrospective, the Erasmus Glioma Database included 733 eligible patients acquired at a single center across nine vendor-by-field-strength configurations. Structural MRI acquired at 1 T, 1.5 T, and 3 T; four structural MRI sequences were analyzed. From four structural MRI sequences, 428 features were computed using an IBSI-compliant PyRadiomics implementation. The sample sizes of some scanner batches were very small compared to others, which may produce unequal precision and shrinkage of batch-effect estimates. We proposed a data augmentation approach to overcome the limitation of ComBat. We provided exploratory evidence, along with confirmatory Kruskal-Wallis tests with a Benjamini-Hochberg correction to assess the proposed method. Before harmonization, 392/428 features (91.6%) differed significantly across scanner batches (median eta-squared=0.463). Standard ComBat reduced this to 13/428 (3.0%), whereas batch-augmented ComBat reduced it to 8/428 (1.9%); the median residual effect size was <0.001 for both harmonized conditions. Batch augmentation appeared to be a useful strategy to improve the performance of ComBat for feature harmonization under severe batch-size imbalance.

0.32

Learning to read residual images for single-pixel photography

eess.IV cs.AI ·2026-11-01 ·Hongjun An, Shuaizhe An, Tong Tian, Zhe Sun
Abstract · first submit

Continuous video scales in cost with camera count, resolution and recording duration, yet many monitoring tasks seek events rather than complete images and can operate on a compact single-pixel measurement stream. Recovering a chosen interval as video is then desirable, but at 0.24\% of the pixel count the scene correlation image looks like noise and per-clip optimization takes minutes. Correlating the residual of an estimate with the coding patterns nevertheless gives a residual image, the gradient of a centered measurement loss. Lifted through a pretrained video decoder, its agreement with the true error exceeds that of control decoders. Video-latent inversion (VLI) then outperforms frame-wise image-latent reconstruction at 1{,}000 bucket values. Measurement-Gradient-Conditioned Video Flow (MGV-Flow), trained once to read the lifted residual image with preceding frames, reconstructs five frames in 1.55\,s at 22.9\,dB median PSNR, against 398\,s and 18.1\,dB for VLI, with the largest gains in high-motion scenes. Directional fidelity ranks 30 coding configurations and selects one needing a third fewer bucket values. On a physical system, MGV-Flow outperforms per-frame reconstruction without retraining. A sliding window over the bucket-value stream yields 3.2 frames per second on one RTX~4090 and, in theory, 20 frames per second on a data-centre accelerator. Demonstrations are available at https://cavedweller509.github.io/MGV-Flow.

0.29

Event-Based Optical Flow Constraint via Time-Sliced Plane Fitting

cs.CV eess.IV ·2026-11-01 ·Masaki Koike, Yusuke Kameda, Shunichi Sato, Takayuki Hamamoto
published
Abstract · 5 pages, 5 figures, 1 table. Accepted for publication at IEEE VCIP 2026 (2026 IEEE International Conference on Visual Communications and Ima…

Event-based optical flow estimation using spatiotemporal planar approximation inherently assumes constant velocity and tends to average out temporal velocity variations. In this paper, we propose a flow estimation method that extends this planar approximation along the temporal axis. The resulting event-based optical flow constraint allows existing variational optical flow formulations to model temporal motion variation. Specifically, we partition the space-time volume into sub-intervals and apply a two-step planar approximation to track object edges consistently. Moreover, a spatial compensation mechanism and a temporal regularization term are incorporated to compensate for edge displacements and temporally stabilize the flow estimation, respectively. The experimental results show that modeling temporal motion variation improves flow estimation accuracy over conventional methods.

0.28

Task-driven sparse-view planar X-ray computed tomography for axial metrology

eess.IV cs.CV ·2026-11-01 ·Yibin Tian, Shuming Yang, Wolfgang Heidrich
Abstract

Computational imaging can reduce the acquisition burden when the system is designed around task-relevant information rather than complete image recovery. We investigate this framework for sparse-view planar X-ray tomography (XCT) of layered objects, using measurement of the axial termination gap (ATG) of back-drilled printed-circuit-board (PCB) vias as a representative task. Instead of using 3D reconstruction, the proposed method estimates ATG directly from polychromatic projection data through a physics-based sensitivity model. A gated hierarchical estimator first fits ATG together with radiometric perturbations and selectively introduces global geometry and specimen-warp models only when a reduced chi-squared adequacy test and Bayesian information criterion justify the added degrees of freedom. The same low-dimensional perturbation model is incorporated into marginalized Fisher-information analyses, yielding task-specific conditional and calibration-aware Cram'er-Rao bounds. Numerical experiments show that, under a fixed total photon budget, task-driven metrology changes little over 12-64 views, while reconstruction-driven metrology is strongly view-dependent with much larger errors. The direct estimator also follows the expected photon-limited scaling. These results demonstrate a computational sensing strategy in which XCT acquisition, physical modeling, and inference are evaluated according to the quantitative information required by the task rather than for general-purpose volumetric image fidelity.

0.25