CS Paper Radar

Daily listing

2026-11-20 · eess.IV

13 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 13

The UNIFESP Chest CT Fatty Liver Dataset

eess.IV cs.CV ·2026-11-20 ·Augusto Sarquis Serpa, Mariana Ramos Scolari, Eduardo Moreno Judice de Mattos Farina, Eduardo Caminha Nunes, Felipe Matsuoka +2 more
code/dataunusual
Abstract · 7 pages, 3 figures, 2 tables. Presented in part as a poster at the EuSoMII Annual Meeting 2022

Hepatic steatosis is common, usually asymptomatic, and frequently visible on CT examinations performed for other reasons, including chest CT, in which the upper abdomen is partly included. We describe the UNIFESP Chest CT Fatty Liver Dataset, a public collection of 285 unenhanced CT studies (344 series, 99,883 images) from 264 patients examined at a single academic center in Brazil: 152 patients with chest CT and 112 patients with abdominal CT. Each patient has a binary label for the presence of hepatic steatosis, assigned by a radiology resident who compared the attenuation of three regions of interest in the liver with one in the spleen. Images are provided in de-identified DICOM format. The dataset was used in the UNIFESP Chest CT Fatty Liver Competition, hosted on Kaggle in 2022, with 226 patients for training and 38 patients with chest CT for testing. In a technical validation, the criterion of liver attenuation lower than spleen attenuation, measured automatically, agreed with the labels in 206 of the 226 training patients (91%). The dataset is available at https://www.kaggle.com/competitions/unifesp-fatty-liver.

0.44

Underwater Spectral Recovery via Multi-View Hyperspectral Imaging

eess.IV cs.CV ·2026-11-20 ·Jonathan Sterckx, Alice James, Avishkar Seth, Laurens Diels, Michiel Vlaminck +3 more
Abstract · Preprint. Code and data can be shared upon publication. 27 pages (15 main, 12 appendix), 12 figures

Underwater imaging suffers from wavelength-dependent absorption and scattering that distort scenes and obscure spectral signatures. While RGB restoration improves visual clarity, the outputs remain broadband and tied to the sensor's color space. We introduce a physically grounded framework that lifts underwater restoration to continuous spectral radiance using multi-view hyperspectral imaging. By representing continuous spectra via low-rank basis functions and leveraging multi-distance observations, our framework jointly constrains scene radiance and water parameters. We employ a robust sparse-to-dense pipeline: water parameters are estimated from consistent multi-view matches and then applied globally to invert the light transport model across the full images. Validated on physics-based synthetic data rendered via the Mitsuba 3 spectral path tracer, our method recovers physically meaningful radiance spectra and, as a downstream application, outperforms standard image restoration baselines.

0.36

Quality-Control Policies Shape Model Behaviour in Computational Pathology

eess.IV cs.CV ·2026-11-20 ·Mario Parreño Centeno, Yu Guan, Pedro Montero Pavón, Sanna Palosaari, Juha Väyrynen
Abstract · 50 pages, 7 main figures, 22 supplementary figures, 1 table; includes supplementary methods and results, and 5 ancillary data files

Quality-control policies determine which image regions are used by computational pathology models, but their effects are difficult to isolate when quality estimation and input selection are coupled. We make these policies explicit, configurable and testable. We introduce PathQC-3C, comprising 1,661 densely annotated regions from 1,194 haematoxylin and eosin whole-slide images across 32 cancer/tissue categories, and TileNet, a framework that separates dense tissue/background/artefact estimation from task-specific input-selection policies. We evaluated the default predictor across three held-out cohorts and against harmonised quality-control comparators, assessed policy decisions in a blinded single-pathologist audit, and tested alternative policies in three downstream settings. In retrospective CAMELYON16 multiple-instance learning, background-aware selection improved the pooled out-of-fold area under the receiver operating characteristic curve from 0.758 to 0.839 compared with random sampling from the same exhaustive candidate pool under a fixed tile budget. In weak-label lung classification, strict artefact exclusion reduced the pre-matching candidate pool by approximately 43%, with small metric-dependent differences after matching training-set size and patient contribution. PathQCAug, which composites real artefact components during tumour-stroma model adaptation, improved macro Dice on high-artefact tiles under severe held-out composited artefacts across three training seeds and outperformed random-erasing and clean-tissue controls. Separating quality estimation from policy execution provides an auditable way to control which image content enters computational pathology models; the appropriate policy is task specific, and clinical utility remains to be established.

0.35

EID-Net: Endoscopic Illumination-aware Degradation Correction Network

eess.IV cs.CV ·2026-11-20 ·Junzhi Liu, Yinghao Zeng, Yang Liu, Huafeng Li, Xiaosong Li
code/data
Abstract · 7 pages, 5 figures

Endoscopic images captured under complex illumination conditions often suffer from spatially non-uniform exposure degradation, including local under-exposure, over-exposure, and illumination-induced color variation. These degradations are usually entangled with tissue structures, making it challenging for general-purpose low-light enhancement and image restoration methods to improve visibility while preserving local structural and chromatic cues. In this paper, we propose EID-Net, an endoscopic illumination-aware degradation correction network for structure-preserving endoscopic illumination correction. Rather than treating illumination correction as a global intensity adjustment, EID-Net explicitly extracts an endoscopy-oriented degradation prior from the input image to characterize illumination-related variations in a unified representation. This prior is then introduced into the decoder through an illumination-modulated transposed attention mechanism, where it adaptively guides feature aggregation by modulating the key-value feature subspace. Extensive experiments on CEC, Endo4IE, EndoVis17, and EndoVis18 datasets demonstrate that EID-Net performs favorably against recent endoscopic enhancement and general image restoration methods. The code is available at https://github.com/JUNZHIlius/EID-Net.

0.33

From Tokens to Pixels: Training-Free Guided Upsampling of Frozen CARL Features for Hyperspectral Imaging

eess.IV cs.CV ·2026-11-20 ·Dominik Fromme, Ellen Markowski, Tim Streckert, Jörg Thiem
benchmark
Abstract · 17 pages, 16 figures, 5 tables. Code and result tables: https://gitlab.fb10.fh-dortmund.de/fb10-opensource/CARL-tokens-to-pixels

Camera-agnostic foundation models such as CARL map spectral images from arbitrary sensors into a shared feature space, but deliver their features only on a token grid at one eighth of the input resolution. The usual bilinear interpolation blurs material boundaries over about one token and rounds off corners. We investigate how much spatial accuracy image-guided upsampling recovers for frozen CARL features without training the encoder or the upsampler. We compare joint bilateral upsampling (JBU), a guided filter and the pretrained AnyUp, each with the hyperspectral image or an RGB rendering as the guide. A hyperspectral ColorChecker dataset acquired specifically for this study, with model-independent reference geometry measured to sub-pixel precision, serves as the evaluation benchmark. JBU with the hyperspectral guide raises the Boundary IoU from 13 to 67 % and reduces the effective edge width of the features from 38 to 4 px, close to the resolution of the raw spectra. The effect occurs in all 24 patches of the ColorChecker and replicates on an additional recording. On placenta and oral cavity images, the feature edges also become markedly qualitatively sharper. For sharp, high-contrast boundaries, JBU is the most accurate and most economical method. On tissue with softer transitions, the pretrained AnyUp yields qualitatively sharper contours. An analysis of 78 simulated band configurations shows that the gain persists in every configuration as long as the head matches the configuration. Image-guided upsampling is thus a simple, training-free step for applications that use CARL frozen with linear heads.

0.33

Dem2TA: Beyond Pixels, Towards Perception

eess.IV cs.CV ·2026-11-20 ·Ping Chen, Zhongwei Lin, Xiang He, Xiangming Wang, Kai Zhang +5 more
Abstract · 16 pages

Task-oriented image signal processors (ISPs) adapt RAW-to-RGB processing for downstream perception. However, explicit demosaicing is often simplified, kept fixed, or optimized primarily for reconstruction quality, leaving this stage insufficiently integrated into task adaptation. We propose \textbf{Dem2TA}, a framework that incorporates fidelity-supervised demosaicing into the adaptation of the perception pipeline. Starting from a pretrained demosaicing model, we jointly adapt the reconstruction frontend and downstream network using reconstruction and task supervision, together with complementary semantic and task representation alignment. We then freeze the adapted frontend and jointly optimize a lightweight local ISP with the downstream model to refine task-specific rendering without changing the reconstructed linear RGB. Experiments on synthetic RAW detection and box-prompted segmentation demonstrate the effectiveness of representation-guided joint adaptation and subsequent local rendering. Evaluation on a manually verified real-capture dataset further supports transfer beyond synthetic inputs. Compared with TA-ISP on the same adapted foundation, Dem2TA improves detection AP by 0.46 points and segmentation IoU by 1.06 points on synthetic COCO RAW, and segmentation IoU by 0.63 points on real captures.

0.29

Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRI

eess.IV cs.CV ·2026-11-20 ·Anika Knupfer, Maximilian Lindholz, Maria Camila Bustos-Vivas, Joseph V. Hajnal, Bodo Rosenhahn +1 more
Abstract · 11 pages, 6 Figures

Clinical MRI typically acquires the organ of interest as consecutive stacks of 2D slices in different orientations. Reconstruction methods such as SVRTK and NeSVoR fuse them into one volume and down-weight what does not fit, although in living tissue the change during the scan is often the signal itself and can contain clinically relevant physiological information, such as fetal motion and uterine contraction. We propose an analysis-by-synthesis decomposition that explains every acquired voxel through its exact acquisition geometry as a static anatomy shared by all stacks, a rigid and smooth non-rigid motion per stack, and a sparse transient field per stack for changes during one acquisition only. A robust reweighting keeps such changes out of the anatomy. The model is fitted per subject without training data, with one configuration for all datasets. On a digital phantom with known ground truth, static changes are kept entirely in the anatomy, and the transient field of the stack that saw a transient recovers 68% of it at 12mm radius. From identical inputs, the anatomy predicts held-out stacks better than SVRTK and NeSVoR on uterine (NCC 0.897 against 0.874 and 0.863, 123 patients) and on prostate MRI from unseen sites and scanners (0.847 against 0.795 and 0.757, 85 patients), and on fetal brain MRI as well as SVRTK and better than NeSVoR (0.771 against 0.763 and 0.747, 83 fetuses). The transient fields flag corrupted fetal slices with an AUROC of 0.94 against expert raters. As the input of a frozen anomaly detector trained on healthy subjects only, the anatomy localizes radiologist-delineated uterine lesions better than the SVRTK and NeSVoR volumes (AUROC 0.76 against 0.71 and 0.71, 37 patients).

0.29

Particle picking with an earth mover's seminorm

eess.IV ·2026-11-20 ·Dvir Moshe, Amit Moscovich, Amit Singer, Ayelet Heimowitz
Abstract

Particle picking is a key step in single-particle cryo-electron microscopy. It is a challenging task where tomographic projections of proteins and other macromolecules are identified in extremely noisy images. In this work, we introduce a particle picker based on a seminorm defined in terms of a fast wavelet approximation to the earth mover's distance. Our picker is template-free, self-supervised and does not require any prior knowledge of the molecules of interest other than their approximate size. We test it on three public datasets and show that it achieves state-of-the-art reconstructions.

0.23

InterBand-EMG: A Cross-Band Foundation Model for Generalizable Hand-Pose Estimation

cs.CV cs.ROeess.IV ·2026-11-20 ·Zongheng Guo, Tao Chen, Dalong Du, Yijian Yang, Heng Liu +11 more
Abstract · 25 pages, 8 figures

Surface electromyography (sEMG) enables continuous hand-pose estimation, but learning representations that generalize across users and movements remains challenging. We introduce InterBand-EMG, which combines band-specific quantization with cross-band reconstruction and structured masked code prediction to learn transferable EMG representations for hand-pose tracking. We also introduce SynapMyo, an eight-channel EMG-to-pose dataset comprising 1,227.74 hand-hours from 499 users across 68 movement categories. Experiments on emg2pose and SynapMyo show that InterBand-EMG outperforms state-of-the-art baselines in joint-angle accuracy across all three generalization settings on both datasets. The source code and the SynapMyo dataset will be publicly released upon acceptance of this paper.

0.21

Learned Score-Based Turbo Message Passing for Compressive Image Recovery

eess.IV ·2026-11-20 ·Peihang Li, Hao Jiang, Xiaojun Yuan
Abstract

Score-based generative models have been incorpo-rated into message passing algorithms for compressive image recovery, providing a prior for the denoising module in message passing. Score-based generative models assume the input signal to be a clean signal perturbed by independent and identically distributed (i.i.d.) Gaussian noise. Yet, this assumption often fails during message passing, leading to slow convergence and limited reconstruction quality. In this letter, we propose the learned score-based turbo message passing (LSTMP) algorithm to overcome this limitation. By employing a deep unfolding framework, LSTMP unrolls the iterative process into a neural network, enabling the denoiser to adapt to complicated noise distributions inherent in the iterative updates. Furthermore, by treating the denoiser as an iterative solver, we incorporate the likelihood information of compressed measurements into the neural network of the denoiser, resembling the message passing between linear and nonlinear modules in STMP. Experiments on the FFHQ dataset show that LSTMP achieves convergence in no more than three iterations while delivering high-ffdelity re-constructions, signiffcantly outperforming the existing baselines.

0.20

FM4SAR-Bench 1.0: Towards A Fair Benchmark for Evaluating Foundation Models for SAR Image Interpretation

eess.IV cs.CVcs.LG ·2026-11-20 ·Mingyao Chen, Yongxiang Liu, Tianpeng Liu, Yuchen Yong, Jie Zhou +8 more
benchmark
Abstract

Foundation models have advanced SAR image interpretation but created a heterogeneous, fragmented model ecosystem. Existing models differ substantially in their input, training data, objectives, architectures, and release policy, yet the field lacks a unified taxonomy and comparative framework. Current evaluations rely primarily on task-specific benchmarks, which are ill-suited to fair comparison among models with fundamentally different input-output formats and task paradigms, and often overlook data transparency, reproducibility, interpretability, and deployment readiness. Limited SAR data accessibility also means high reported performance does not guarantee access to training data, code, or weights, limiting reproduction, benchmarking, and deployment. To address these issues, we propose a systematic taxonomy and hierarchical evaluation framework for SAR-related foundation models: five rating levels, six dimensions, and fine-grained criteria, with separate protocols for VFMs and VLMs. Beyond overall ratings, it yields interpretable multidimensional capability profiles and supports user-defined weighting, so rankings follow user priorities. Utilizing a fixed auxiliary multimodal large language model in combination with human review, we conduct a systematic meta-analysis and multidimensional assessment of 76 VFMs and 40 VLMs. In terms of SAR benchmark task performance under our framework, SAR-native VLMs do not significantly outperform remote sensing VLMs pretrained on mixed multimodal corpora in which SAR is one of several modalities. This lack of clear advantage is largely due to data availability: large-scale, high-quality, public annotated SAR data remain scarce, restricting both model and training-data scale for SAR-native models. The framework provides a structured basis for requirement-aware model selection and remains extensible as new models emerge.

0.19

Feasibility of Multifrequency Neural Network-Based Wave Inversion in Ultrasound Time-Harmonic Elastography

eess.IV cs.CV ·2026-11-20 ·Héloïse Bustin, Tom Meyer, Paul Spiesecke, Jakob Jordan, Anja Hennemuth +1 more
Abstract

Ultrasound time-harmonic elastography (THE) is a non-invasive imaging technique that measures soft-tissue stiffness. Relying on the same principle of time-harmonic shear wave excitation as established magnetic resonance elastography (MRE), THE offers full field-of-view stiffness mapping at short acquisition times and sub-second temporal resolution across organs. However, reconstruction of shear wave speed maps from acquired tissue wavefields remains challenging due to speckle noise and sparse spatial coverage of the lateral component. Deep learning methods have shown promising results for image reconstruction in transient-based ultrasound elastography modalities but remain unexplored in THE. In MRE, MF-ElastoNet, a 2D multifrequency neural network-based wave reconstruction method trained on synthetic physics-based wave data, has shown high generalizability across dynamic ranges and resolutions. We investigated the potential of a multifrequency neural network-based wave inversion for THE, by performing a first feasibility analysis. To this end, we adapted the processing pipeline of MF-ElastoNet from MRE to THE. We tested our approach on THE acquired phantom data from the algorithms for mapping elastic modulus Challenge, as well as on in vivo liver THE in 4 healthy volunteers and 14 patients with focal liver lesions, including benign focal nodular hyperplasia, and malignant hepatocellular carcinoma and adenocarcinoma. MF-ElastoNet was successfully adapted to THE with in vivo liver testing. Compared with k-MDEV, the state-of-the-art wave inversion method for THE, Bland-Altman analysis showed a mean bias of -0.02 m/s (95% limits of agreement: -0.36 to 0.33 m/s).

0.19

Duplicate- and Patient-Overlap Leakage in Brain MRI Tumor Classification: A Multi-Model Evaluation

eess.IV cs.CV ·2026-11-20 ·Xin Li, Samson Oluwadare
benchmark
Abstract · 14 pages, 6 figures, 2 table

Background. Repeated MRI images and distinct slices from the same patient can both compromise evaluation of brain tumor classifiers. Objective. We audited image duplication and examined how patient overlap relates to discrimination, probability error and model ranking. Methods. The Cheng/Figshare dataset contains 3,064 contrast-enhanced T1 MRI slices, three tumor classes and 233 recorded patient IDs. The dataset author advised treating the IDs as individuals, but original DICOM records were unavailable for verification. Four CNN architectures were trained under image-level and recorded-ID-disjoint protocols with five folds matched on size and class counts (40 original runs). A patient-cluster bootstrap quantified uncertainty. The extension added 60 split-seed runs, 40 training-seed runs and 72 fixed-test sibling-exposure runs with class-matched other-patient controls. Results. We found no exact duplicate images and little evidence of cross-patient near-duplicates among screened pairs. Image-level minus recorded-ID-disjoint balanced accuracy ranged from +0.0318 to +0.0462 across models. Expected calibration error and multiclass Brier scores were lower on the image-level evaluation sample. The balanced-accuracy difference persisted across new seeds for ResNet50 and DenseNet121, but their original ranking reversal did not replicate. Only ResNet50 in fold 2 passed Holm correction in the five-test exposure family. All 16 correlated exploratory subgroup estimates were positive, with no consistent dose-response. Conclusions. Patient overlap was associated with higher apparent performance on this benchmark. Fixed-test comparisons could not isolate patient identity from shared anatomy or acquisition characteristics. No independent external clinical validation was performed.

0.17