CS Paper Radar

Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRI

Anika Knupfer, Maximilian Lindholz, Maria Camila Bustos-Vivas, Joseph V. Hajnal, Bodo Rosenhahn, Jana Hutter

eess.IV cs.CV ·submitted 2026-11-20 11:50 UTC · v1

Abstract

Clinical MRI typically acquires the organ of interest as consecutive stacks of 2D slices in different orientations. Reconstruction methods such as SVRTK and NeSVoR fuse them into one volume and down-weight what does not fit, although in living tissue the change during the scan is often the signal itself and can contain clinically relevant physiological information, such as fetal motion and uterine contraction. We propose an analysis-by-synthesis decomposition that explains every acquired voxel through its exact acquisition geometry as a static anatomy shared by all stacks, a rigid and smooth non-rigid motion per stack, and a sparse transient field per stack for changes during one acquisition only. A robust reweighting keeps such changes out of the anatomy. The model is fitted per subject without training data, with one configuration for all datasets. On a digital phantom with known ground truth, static changes are kept entirely in the anatomy, and the transient field of the stack that saw a transient recovers 68% of it at 12mm radius. From identical inputs, the anatomy predicts held-out stacks better than SVRTK and NeSVoR on uterine (NCC 0.897 against 0.874 and 0.863, 123 patients) and on prostate MRI from unseen sites and scanners (0.847 against 0.795 and 0.757, 85 patients), and on fetal brain MRI as well as SVRTK and better than NeSVoR (0.771 against 0.763 and 0.747, 83 fetuses). The transient fields flag corrupted fetal slices with an AUROC of 0.94 against expert raters. As the input of a frozen anomaly detector trained on healthy subjects only, the anatomy localizes radiologist-delineated uterine lesions better than the SVRTK and NeSVoR volumes (AUROC 0.76 against 0.71 and 0.71, 37 patients).

Comment
11 pages, 6 Figures

Closest papers

Nearest neighbours by meaning across the whole index.

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI

cs.CV ·2026-08-19 ·Arnaud Boutillon, Naomi Clarke, Tomas Woodgate, Daniel West, Alina Schneider +6 more
similarity 0.65
Abstract

Fetal cardiac MRI (fCMR) provides valuable diagnostic information complementary to echocardiography, particularly for complex congenital heart disease (CHD). Dynamic cine imaging captures cardiac motion essential for assessment of cardiac function; however, the reconstruction of 3D+time cine volumes from 2D+time acquired slices remains challenging due to unpredictable fetal motion and the absence of automated and robust processing tools suitable for clinical deployment. We present the SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientation. The proposed SVR algorithm achieves a tenfold reduction in reconstruction time relative to existing frame-wise approaches ($4.8 \pm 1.0$ vs $49.0 \pm 14.1$ min, $p < 0.0001$) while improving the reconstruction quality. Thoracic segmentation performance using ensemble aggregation exceeded inter-rater agreement (Dice $84.7 \pm 3.9\%$ vs $81.4 \pm 7.7\%$, $p<0.05$), while anatomical reorientation achieved a success rate of $90.1\%$. End-to-end evaluation on a large held-out clinical cohort ($n = 121$) demonstrated fully automatic processing in $82.6\%$ of cases with a mean runtime of $7.1 \pm 1.3$ min, compatible with clinical deployment. The complete SPARC pipeline is publicly available as a Docker container https://hub.docker.com/r/aboutill/sparc and is currently deployed at our institution as a clinical research tool.

0.37

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.64
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Learning Where and How Much to Sample: Volume-Adaptive k-Space Acquisition for Accelerated MRI

cs.CV ·2026-11-18 ·Reyhaneh Neshatavar, Mohsen Yavartanoo, Kyoung Mu Lee
similarity 0.63
Abstract

Magnetic resonance imaging (MRI) is an essential medical imaging technique, but its high costs and long acquisition times can limit accessibility. Accelerated MRI reduces acquisition time through k-space undersampling, yet conventional methods often rely on predefined sampling patterns and uniform slice budgets, overlooking anatomical variations and inter-slice relationships. In this paper, we propose a volume-adaptive k-space acquisition framework that jointly learns where and how much to sample across an entire MRI volume. Using only acquired auto-calibration signal (ACS) measurements, our method exploits volume-wide anatomical information to adaptively allocate sampling budgets across slices while identifying informative k-space lines. A learned joint slice--frequency refinement module coordinates sampling decisions while preserving an exact total volume-level acquisition budget. To reconstruct the acquired measurements, we design a sensitivity-aware synchronous cross-slice reconstruction network that estimates coil sensitivities from ACS measurements and progressively refines neighboring-slice reconstructions while enforcing hard k-space data consistency. Both networks are jointly optimized using reconstruction-based supervision without requiring fully sampled k-space at inference. Experiments on knee and brain MRI across multiple contrasts and acceleration factors demonstrate the adaptive behavior of our acquisition framework and evaluate its reconstruction performance.

0.23

CATCH: Counterfactual Anatomical Tissue Inpainting with Conditional Haar Diffusion

cs.CV cs.AI ·2026-09-01 ·Simon Winther Albertsen, Hjalte Bjoernstrup, Said Djafar Said, Mostafa Mehdipour Ghazi
published similarity 0.62
Abstract · Accepted at the 15th BraTS Workshop in MICCAI 2026

BraTS local synthesis replaces masked regions in T1-weighted brain MRI with plausible tumor-free tissue while preserving observed anatomy. We present CATCH, conditional 3D diffusion in an invertible Haar-wavelet domain. Its denoiser receives noisy target coefficients, voided-image coefficients, and a signed mask; tumor-excluded wavelet reconstruction and a hole-focused loss guide training, and hard compositing preserves observed voxels. We compare fixed masks, tumor-component augmentation, and a weighted mixture of tumor-derived, irregular-blob, and ellipsoidal masks. Of 25 development cases, five prespecified cases select each arm's checkpoint and all 25 of their trajectory aggregations; a separate 75-case internal set compares the frozen pipelines and selects a weighted mixture for organizer evaluation. Five-trajectory averaging yielded internal SSIM/PSNR/MSE (mean$\pm$SD) of $0.80\pm0.13$, $19.18\pm1.80$dB, and $0.010\pm0.005$. As the sole officially evaluated pipeline, weighted mixture yielded $0.772\pm0.119$, $20.89\pm3.27$dB, and $0.0098\pm0.0054$ on the 219-case BraTS 2026 validation set. Against compute-matched random augmentation internally, it improved SSIM by 0.019 (95% bootstrap CI: 0.013-0.025), PSNR by 0.95dB, and MSE by 0.003; all three paired comparisons remained significant after Holm correction. Results favor the complete weighted-mixture policy within CATCH; absent official fixed- and random-pipeline scores and a directly comparable external baseline limit broader conclusions.

0.30

FM-Recon: Exploring Foundation Model Features for Accelerated Cardiac Cine MRI Reconstruction

cs.CV cs.AI ·2026-11-16 ·Donghang Lyu, Marius Staring, Ruochen Gao, Jochen Keupp, Hildo J. Lamb +1 more
similarity 0.61
Abstract

Foundation models have demonstrated strong feature extraction capabilities across various medical imaging tasks, yet their potential for MRI reconstruction remains largely unexplored, particularly within unrolled reconstruction networks and under artifact-corrupted inputs. In this work, we explore whether and how features from pretrained foundation models can benefit accelerated cardiac cine MRI reconstruction. To this end, we propose FM-Recon, a framework that refines and integrates extracted features from frozen image encoder of foundation models into an unrolled reconstruction network. Through extensive experiments on the CMRxRecon2023 dataset, we systematically evaluate foundation model features across different reconstruction settings. Our results show that foundation models can extract informative representations from artifact-corrupted inputs and improve reconstruction performance, particularly at moderate acceleration factors. These findings demonstrate the potential of foundation model features for accelerated MRI reconstruction and provide insights into their effective integration into unrolled reconstruction networks.

0.13

VariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly Detection

cs.CV ·2026-10-30 ·Arnela Hadzic, Martin Urschler, Cosmin I. Bercea
published similarity 0.61
Abstract · Accepted for WACV 2027

Reconstruction-based anomaly detection no longer fails at reconstruction. Generative models produce high-quality pseudo-healthy reconstructions, and the remaining difficulty is the step of scoring residuals. The residual between a scan and its reconstruction has two indistinguishable sources, genuine pathology and the anatomical variation that separates one healthy brain from another. Scoring against a single reconstruction treats both as anomalous, inflating false positives where healthy anatomy varies most while small or subtle lesions are lost in the surrounding reconstruction error. We identify the missing quantity as the predictive variance, how much a healthy reconstruction can vary at each location. We introduce VariaFlow, which estimates this variance from an ensemble of mask-guided restorations under an unconditional flow matching prior, each started from a different noise initialization, and which normalizes the residual by the resulting standard deviation. Few-step flow matching keeps the ensemble computationally affordable, and restoring at two spatial scales captures lesions of different size. Across three brain MRI datasets spanning stroke and tumor, VariaFlow is trained once on healthy anatomy and generalizes across all three, attaining the highest AUROC (0.94, 0.80, 0.78) on each and the highest AUPRC on both cross-domain datasets, exceeding the strongest baseline by 37% and 50%. Under domain shift, the same baseline drops by up to 52% in AUPRC, whereas VariaFlow stays more stable and achieves the best small-lesion Dice on all three datasets.

0.29

One Block Is Enough: LoopMR for Accelerated MRI Reconstruction

eess.IV cs.CV ·2026-11-11 ·Yimeng He, Yibin Xie, Yi Zheng, Yifan Gao, Lixia Wang +5 more
code/data similarity 0.61
Abstract · 10 pages, 7 figures, 6 tables. Code: https://github.com/hym97/LoopMR

Deep-learning unrolled networks are the leading approach to accelerated MRI reconstruction. State-of-the-art models such as PromptMR+ learn a distinct block for every cascade, so their size grows with the number of cascades. Sharing one block across iterations avoids adding parameters, but earlier shared-weight models typically used a tiny block and produced worse images than models with distinct weights. Therefore, it remained unclear whether weight sharing itself or the choice of block was the problem. Recent advances in looped transformers, which reuse the same block across layers, show that they can match or outperform their distinct-weight counterparts on several tasks. Motivated by this, we propose LoopMR, which reuses a single Restormer block at every iteration as its core. Besides the current image estimate, the block receives data-consistency inputs and latent images. On four datasets covering the brain (CC359), knee (fastMRI), heart (CMRxRecon2023) and carotid (in-house), LoopMR significantly outperforms E2E-VarNet, PromptMR and PromptMR+ in PSNR and SSIM at every acceleration factor (p < 0.01), with about 1/9 of PromptMR+'s parameters (10.3M versus 92.9M). It also keeps its lead at unseen acceleration factors and on an unseen dataset. With our transformer block, the shared model matches or outperforms its distinct-weight counterpart at 6, 12 and 24 iterations. At a fixed number of iterations, shared transformer blocks match or outperform their distinct-weight versions, while shared CNN blocks perform worse. These results suggest that looping one well-chosen block can outperform stacking distinct cascades in MRI reconstruction, with a fraction of the parameters.

0.24

Uncertainty-Aware 3D Residual Wavelet Diffusion for Ultra Low-Field MRI Super-Resolution

cs.CV ·2026-09-21 ·Rui W. Yeow, Millie Beament, Fred Dick, Raha Razin, Martina Bocchetta +4 more
published similarity 0.61
Abstract · 11 pages, 3 figures, 1 table. Accepted at SASHIMI 2026 (MICCAI 2026 workshop). This is the version submitted for peer review

Ultra low-field MRI expands global access to neuroimaging but produces scans with low signal-to-noise ratio, reduced contrast, and thick slices. While regression-based super-resolution can recover anatomical detail for segmentation, it returns a single deterministic estimate that gives no indication of regions where the low-field input leaves anatomy underdetermined. Generative diffusion models offer an alternative by sampling the posterior distribution of plausible high-field images, quantifying this anatomical ambiguity. However, applying them to 3D whole-brain MRI is restricted by memory bottlenecks, slow sampling, and scanner domain shifts. We propose a 3D residual wavelet diffusion model that combines three ideas to overcome these hurdles. A lossless wavelet reparameterisation shrinks the spatial grid to fit a whole brain on a single GPU, residual shifting accelerates sampling by starting from the low-field input, and domain randomisation promotes scanner generalisation without paired training data. As the high-field reference is not a voxel-aligned ground truth, we evaluate downstream volumetric agreement. On a healthy cohort (n=19) imaged at 0.064T and 3T, our method matches a leading general-purpose regression approach in volumetric accuracy while additionally generating per-voxel uncertainty maps highlighting underdetermined regions. Furthermore, on a pilot dataset (n=11) of participants with cognitive impairment, disease-relevant atrophy is preserved rather than normalised towards a healthy prior. Our framework brings whole-brain posterior sampling to low-field super-resolution without sacrificing volumetric accuracy.

0.35