CS Paper Radar

Coordinated Dynamic Operation of Integrated Electrolyzer-Compressor Systems

Amin Salehi, Janne Seppanen, Mahdi Pourakbari-Kasmaei

eess.SY ·submitted 2026-08-12 11:16 UTC · v1

Abstract

The increasing interaction between power and hydrogen sectors highlights the importance of coordinated operation of electrolyzers and electric-driven compressor stations (EDCSs). This becomes particularly of higher importance under transient disturbances. However, coordinated dynamic interactions of these coupled subsystems remain largely unexplored. This article addresses such gap by developing a dynamic model for an integrated electrolyzer-EDCS system and designing appropriate PID control schemes to address the potential disturbances affecting either component. To this end, linearized models of the electrolyzer and EDCS are first derived to enable systematic controller design. Then, two PID controllers, representing conservative and fast-tracking designs, are developed to coordinate the system response. The developed coordinated model is examined and verified under four different cases. The results demonstrate the effectiveness of the proposed model under disturbances from the compressor driver or the electrolyzer. Controlling the electrolyzer flow in response to EDCS disturbances coordinates system dynamics and mitigates undesirable transient fluctuations. Conversely, under electrolyzer disturbances, regulating the EDCS torque eliminates inconsistent responses in pressure, flow, and rotational speed, while preventing hazardous transient undershoots and overshoots. Overall, the proposed framework guarantees transient stability and operational reliability of the integrated electrolyzer-EDCS system.

Closest papers

Nearest neighbours by meaning across the whole index.

Unit-to-Plant Stability Shaping of Multi-Electrolyzer ReP2H Plants via Interface Design and Dispatch

eess.SY math.OC ·2026-08-24 ·Miao Zhang, Yiwei Qiu, Xiaoyu Wang, Linlin Wu, Yi Zhou +3 more
similarity 0.56
Abstract

Alkaline water electrolysis (AWE) units supplied by insulated gate bipolar transistor rectifiers (IGBT-Rs) may experience oscil-lations caused by coupling between rectifier control and electro-lyzer (ELZ) dynamics. Because this risk varies with unit loading and power allocation, production-oriented dispatch may place a multi-ELZ renewable power-to-hydrogen (ReP2H) plant near or exceed its stability boundary. This paper proposes a stability-oriented framework for control design and plant production dis-patch. A three-port admittance model links the ac port, dc link, and electrolysis stack. Unit-level dc-port analysis quantifies the effects of loading, temperature, Buck bandwidth, and dc-link capacitance, while plant-level aggregation evaluates how unit commitment and power allocation affect stability. Results show that higher loading reduces stability, whereas larger dc-link ca-pacitance and higher Buck bandwidth improve it. Under the same plant loading, different power allocations result in different plant-level stability margins, with balanced allocation generally providing a larger margin than concentrated allocation. The plant-level model thus distinguishes the stability margins of ad-missible schedules. Hardware-in-the-loop (HIL) tests validate these trends and the proposed redistribution rule. The resulting operating regions and dispatch rules can be used to screen unit commitment and power allocation decisions in plant production scheduling.

0.23

Power Management of Electrically Driven Centrifugal Compressors for Flexible Operation

eess.SY ·2026-11-13 ·Alp Albay, Tak Lam Fok, Niklaus Hung, Maiken Omtveit, Mehmet Mercangöz
unusual similarity 0.53
Abstract

We present a control strategy for power management of a variable-speed 15MW (rated power) centrifugal compressor, and investigate how quickly it can follow a reduced electrical power reference without entering surge. We use a Greitzer-Gravdahl type model scaled to industrial size with rate-limited valve actuators as a simulation environment and propose an advanced regulatory control structure using feedback control loops with dynamically scaled feedforward mechanisms and a structure of min/max selectors. In simulated experiments, a 6MW power reduction from varying initial operating points on a 12MW iso-power line is delivered at rates of up to 10MW/s, i.e.to 90% in 0.54s, without opening the recycle valve. Depending on the initial operating point, a large power reduction can be delivered at once or with a restricted ramp rate. The stroking rate of the discharge side valve is identified as the limiting factor for how fast the power can be reduced in the studied configuration. A limited sensitivity study on the impact of rotor inertia for power shedding performance is also provided.

0.25

A Closed-Loop Model of an Anion Exchange Membrane Electrolyser Based on Operational Data

eess.SY ·2026-09-16 ·Maiken Borud Omtveit, Lisa Marie Dannappel, Shi You, Kjetil Uhlen
similarity 0.52
Abstract · 5 pages, IEEE ISGT 2026

The main contribution of this work is to identify model parameters for an Anion Exchange Membrane (AEM) system directly from measured operational data, enabling their use in power system studies. Due to the relatively low technology readiness level (TRL) of AEM electrolysers, only limited literature reports operational parameters supported by openly available experimental data. By capturing the realistic dynamic behaviour and power consumption of the AEM electrolyser, this model allows for more accurate evaluation of system topologies and control strategies for green hydrogen production. This paper presents a model of an AEM electrolyser based on experimental data from Enapter modules installed in the Power-to-X (PtX) Laboratory at the Technical University of Denmark [1]. The model comprises a polarisation curve and a model of current dynamics during operation. It is validated against operational data and can be applied in grid-balancing studies as well as in assessments of how electrolyser dynamics influence the power system. The results suggest that the AEM technology is suitable for services such as smoothing wind farm power output and provide system services to support frequency balancing. The findings highlight the importance of considering the constraints of the process when designing for flexible load operation, and consideration of the interaction between the power control and process control systems.

0.18

Modeling and Parametrization of Large-scale Hydrogen Electrolyzers for Transient and Frequency Stability Analysis

eess.SY ·2026-10-29 ·Mahmoud K. Abdelhamid, Lukas Sigrist, Álvaro Ortega
similarity 0.52
Abstract

Hydrogen Electrolyzers (HEs), particularly Proton Exchange Membrane (PEM)-based systems, are flexible loads capable of providing grid ancillary services and enhancing the stability of renewable-dominated power systems due to their fast electrical response. However, the literature often lacks clear guidance on the structure, modeling, and parametrization of large-scale HEs for transient and frequency stability analyses. This paper presents a detailed configuration for utility-scale HE plants, using the stack as the fundamental unit, supported by a realistic parametrization based on commercial components. Furthermore, this work extends the Generalized ESS Model (GEM), a linearized state-space model previously utilized with other converter-interfaced energy storage systems, to PEM HEs for the first time. To facilitate plant scalability, a robust method for scaling GEM matrices across different capacities is proposed. Finally, a measurement-based methodology is developed to estimate the GEM parameters and subsequently extract the equivalent electrical circuit parameters. Comprehensive simulations on the WSCC system under various disturbances validate the accuracy of the derived GEM, the effectiveness of the scaling approach, and the robustness of the parameter identification methodology.

0.23

Beyond Higher-Pulse Rectification: Operational Harmonic Coordination in Renewable P2H Systems

eess.SY math.OC ·2026-09-03 ·Yangjun Zeng, Yiwei Qiu, Jie Zhu, Yi Zhou, Tao Wu +4 more
similarity 0.51
Abstract

Thyristor rectifiers (TRs) are cost-effective electrolysis power supplies for renewable power-to-hydrogen (ReP2H) systems, but their harmonics may violate grid-code limits. In contrast to conventional solutions that rely on higher-pulse (such as 24-pulse) rectifiers, this paper proposes an operational harmonic coordination scheme that enables low-cost 12-pulse TRs to meet harmonic requirements through coordinated operation. First, a harmonic model quantifies the effects of rectifier transformer (RCT) tap positions and electrolytic currents, enabling harmonic cancellation among multiple electrolyzers (ELZs). A two-layer framework then coordinates hydrogen production and harmonic mitigation. Hourly scheduling determines ELZ commitment within the harmonic feasible region under renewable uncertainty using stochastic programming and a modified progressive hedging algorithm, while minute-level dispatch tracks renewable power and mitigates harmonics. A decomposition algorithm separates production dispatch from harmonic mitigation to improve computational efficiency. Case studies based on real-life projects show that the proposed method increases profit by 31% over current-only regulation. Annual simulations further show that coordinated 12-pulse TRs can replace 24-pulse rectifiers for harmonic compliance by exchanging additional RCT tap actions for lower transformer investment, reducing rectification-stage cost by 37.5%.

0.21

Grid Integration of Gigawatt-Scale Hydrogen Hubs: A Multi-Timescale Stability Analysis and Connection Requirements for Weak Grid Environments

eess.SY ·2026-08-17 ·Mohamed Shamseldein
publishedcode/data similarity 0.46
Abstract

The global transition toward green hydrogen is driving the deployment of gigawatt-scale electrolysis centers, introducing a novel, converter-dominated load class to the bulk power system. Unlike conventional industrial loads, these facilities utilize extensive power electronics interfaces with fast dynamics comparable to Inverter-Based Resources (IBRs). This paper presents a comprehensive grid impact assessment of large-scale hydrogen hubs, focusing on harmonic injection, voltage stability in low Short Circuit Ratio (SCR) environments, and frequency response capabilities. Adopting a "full-spectrum" open-source modeling approach, the study utilizes PandaPower for large-scale steady-state contingency assessment; ANDES for electromechanical dynamic simulations to evaluate Fast Frequency Response (FFR); and ParaEMT for high-fidelity electromagnetic transient analysis of harmonic distortion and Low Voltage Ride-Through (LVRT). A critical finding of this study is that standard load models, including the generic PERC1 (data center) model, are insufficient for hydrogen hubs. The paper recommends specific structural modifications to the PERC1 model - specifically regarding process safety latches and restart voltage thresholds - to accurately capture the risk of prolonged plant tripping. Based on these findings, the paper proposes a set of standardized connection requirements to ensure secure integration.

0.57

Locally homogeneous PID gain-scheduling for motion control systems

eess.SY ·2026-11-16 ·Andrey Polyakov, Michael Ruderman
unusual similarity 0.45
Abstract

A method for upgrading linear PID controller to a locally homogeneous PID regulator is developed. The homogeneous PID shares the gains with linear PID while the tuning of local homogeneity degrees could allow better regulation quality comparing with the linear algorithm. The homogeneous algorithm is obtained by means of the scaling the gains of the linear controller dependently of the current value of the output and its derivative. The linear algorithm can be recovered from the homogeneous one by assigning zero homogeneity degree. The tuning scheme for the homogeneous controller is suggested and illustrated experimentally in comparison with a standard PID control, which is robustly designed by the loop-shaping around the critical frequency range. The experiments are accomplished on a linear-motion stage system with voice-coil-motor and noisy contactless output measurements.

0.28

Multi-time-scale Control of Power Systems

eess.SY math.OC ·2026-10-26 ·Emiliano Dall'Anese, John W. Simpson-Porco, Florian Dorfler, Saverio Bolognani, Sairaj Dhople
survey similarity 0.43
Abstract · Submitted for publication

The power grid has been dominated by large synchronous generators and clearly separated control layers. Today, power-electronics energy conversion interfaces are rapidly being deployed calling for another look at system-level control hierarchies. This article examines how multi-time-scale modeling, feedback control, and feedback optimization can help reinterpret the traditional organically grown hierarchy of primary control, automatic generation control, and economic dispatch, and enable new approaches for control of contemporary power systems. Beginning with an overview of power system models and conventional operational practices, the article develops connections to modern control architectures that can coordinate heterogeneous resources, account for operational constraints, and exploit faster actuation without overlooking first-principles physics.

0.28