CS Paper Radar

Label-Free Deep-Tissue Peripheral Nerve Detection with a Handheld Multimodal OCT Probe and NerveDetNet

Yihan Wang, Ruilin You, Shaobai Li, Jiabin Chen, Bofan Song, Anh D. Le, Rongguang Liang

cs.CV physics.opticsphysics.med-ph ·submitted 2026-08-13 22:34 UTC · v1

Abstract

Peripheral nerves buried beneath intact tissue are difficult to visualize during surgery and remain inaccessible to white light wide-field imaging and other surface optical imaging methods. Existing OCT nerve studies have largely relied on exposed nerves or polarization contrast with limited depth penetration, restricting their value for subsurface intraoperative guidance. Here, we introduce, to our knowledge, the first label-free framework for detecting peripheral nerves beneath unopened tissue and resolving their depth using intensity-based OCT structural signatures alone. The framework combines a handheld multimodal probe, integrating swept-source OCT with co-registered white light and autofluorescence imaging, with a ``confirm-then-capture'' workflow designed for practical surgical use. To enable efficient analysis of sparsely sampled OCT volumes, we develop NerveDetNet, a lightweight 2.5D segmentation network that recovers weak and spatially displaced nerve signals by incorporating spatial context, frame-order information, and shift-tolerant correlations across frames through a dedicated nerve feature correlation module. In ex vivo tissue experiments, NerveDetNet consistently outperformed six representative 2D baselines across all frame spacings, achieving a Dice score of 0.725 under the sparsest sampling condition while using approximately half the model parameters. End-to-end validation demonstrated localization of nerves invisible at the surface and depth-resolved detection up to 1.3--1.4~mm below the tissue surface, with OCT derived depth maps overlaid directly onto the surgical view. Together, these results establish a practical label-free approach for subsurface nerve visualization that supports intraoperative compatibility, enables efficient sparse-volume analysis, and provides depth-resolved guidance without tissue opening, contrast agents, or nerve exposure.

Closest papers

Nearest neighbours by meaning across the whole index.

AxonSynth: Domain-Randomized Synthetic Data for Zero-Shot 3D Axon Segmentation in Light-Sheet Microscopy

cs.CV ·2026-09-25 ·Edward Gaibor, Kyriaki-Margarita Bintsi, Chiara Mauri, Emine Özen, Carmen Luz Leiva Ureta +7 more
published similarity 0.60
Abstract · 11 pages, 2 figures, 2 tables. Accepted at SASHIMI 2026, held with MICCAI 2026

Accurate segmentation of axons in 3D microscopy data is important for analyzing white-matter organization, but dense ground truth labels are expensive to obtain. Existing supervised axon segmentation methods rely on target-domain annotations and can be brittle when tissue type, species, modality, or acquisition conditions change. We present AxonSynth, a domain-randomized synthetic-data framework for training 3D axon segmentation models without manually annotated real training volumes. AxonSynth generates dense synthetic axon labels with orientation priors that reflect realistic fiber configurations and renders them with randomized density, contrast, bias fields, blur, and noise. A three-class 3D U-Net is trained to predict background, axon sheath and intra-axonal space. We evaluate zero-shot transfer on 10 held-out light-sheet microscopy (LSM) patches from macaque and human brain samples labeled with one of three axonal markers, comparing against calibrated thresholding and Frangi filtering using overlap, corrected detection, false-positive, and topology metrics. On macaque samples, AxonSynth achieved the best corrected Dice and corrected precision (0.826 and 0.851), compared with 0.765 and 0.754 for thresholding and 0.685 and 0.762 for Frangi. On human samples, corrected Dice was comparable to thresholding (0.857 vs. 0.868), while component-count error decreased from 22,504 to 3,377. Across all held-out patches, AxonSynth reduced component-count error in 10/10 patches and Euler-characteristic error in 8/10. These results show that synthetic-label domain randomization can reduce dependence on manual axon annotation while supporting synthetic-to-real 3D segmentation.

0.44

OCTN: Neural OCT Representations for Robot-Guided Precision Intervention

cs.RO ·2026-09-06 ·Ravi Prakash, Ryan P. McNabb, Patrick J. Codd, Shan Lin
code/data similarity 0.59
Abstract

Optical coherence tomography (OCT) offers compact, contactless, micron-scale imaging suitable for intraoperative guidance, but native OCT volumes are discretely sampled, anisotropic, and currently inefficient for downstream geometric reasoning and robot integration. We present OCTN (pronounced "octane"), an implicit neural representation framework that converts volumetric OCT scans into a continuous, differentiable, and spatially faithful tissue-intensity field. OCTN uses a two-stage hybrid training strategy that combines supervision from acquired voxels with inter-slice interpolations, preserving B-scan fidelity while improving continuity in sparsely sampled regions. For versatility, we first show that OCTN enables fast volumetric reasoning by storing the learned tissue representation natively on the GPU, supporting intensity-based spatial queries with up to 43x speedup over conventional CPU processing. We then demonstrate OCTN-enabled OCT-guided robotic laser surgery where the continuous tissue representation supports implicit surface discovery and surface-constrained path planning via multiple optimization strategies, including Newton- and SGD-based optimization. Next, OCTN enables reconstruction of dense volumetric structure from sparsely acquired B-scans, while reducing acquisition time by 4x and preserving clinically relevant structures. Across the newly generated Duke TissueOCT dataset and public OCT datasets, OCTN achieves robust, high-fidelity reconstruction with PSNR > 30 dB and training time < 10 s, while preserving surface consistency within 10 $μ$m Chamfer distance relative to baseline reconstruction. The TissueOCT dataset and code are publicly available at raprakashvi.github.io/octn

0.20

CRISP: Corneal Confocal Microscopy Real-Time Image Stitching Pipeline

cs.CV ·2026-09-07 ·Qincheng Qiao, Puli Zhang, Jian Zhou, Xinguo Hou
code/data similarity 0.59
Abstract · 7 pages, 2 figures. Code: https://github.com/SummerColdWind/CRISP

Morphology of the sub-basal nerve plexus (SNP) reflects peripheral nerve health, and corneal confocal microscopy (CCM) provides an important means for in vivo, real-time, non-invasive observation of the SNP. However, mainstream CCM devices offer a limited field of view per frame, whereas the SNP is spatially non-uniform; discrete image sampling is therefore sensitive to sampling location and frame selection, which limits the reproducibility and clinical adoption of CCM as a quantitative assessment tool. Wide-field stitching can reconstruct larger SNP mosaics by integrating sequentially acquired CCM images, but existing methods largely rely on offline post-processing, additional hardware, or specific acquisition protocols, and lack open-source real-time solutions for conventional CCM video streams. This paper presents CRISP (Corneal confocal microscopy Real-time Image Stitching Pipeline), an open-source real-time SNP wide-field stitching framework for conventional CCM examination video streams. CRISP excludes defocused and discontinuous segments via focus-aware gating, propagates poses through local pairwise registration, and maintains non-redundant spatial coverage with a sparse anchor map; when local temporal continuity is interrupted, the system completes relocalization and subgraph merging through global appearance retrieval followed by geometric verification. The framework prioritizes low-latency coverage feedback during examination while outputting accepted frames, poses, and anchor information to initialize offline fine stitching. To our knowledge, CRISP is the first open-source real-time SNP wide-field stitching framework released for conventional CCM video streams. By lowering the barrier to adoption and reproduction of wide-field stitching, CRISP may help move SNP wide-field imaging from a research tool into routine clinical examination workflows.

0.43

InnerLogic-Surg: An Open Surgical Foundation Model via Continual Pretraining

cs.CV cs.AI ·2026-11-05 ·Kun Yuan, Hao Ding, Yiqing Shen, Gasper Podobnik, Benjamin Killeen +3 more
benchmark similarity 0.58
Abstract

Vision foundation models are the backbone of modern surgical image analysis, yet most surgical systems still rely on encoders pretrained on natural images or on specialist models trained from scratch on comparatively small datasets. Pretraining encoders on large amounts of surgery-specific data has the potential to generally enhance the performance of surgical image analysis methods simply by providing stronger backbones. Here we present InnerLogic-Surg, an open family of surgical vision encoders (21M--300M parameters) obtained by continually pretraining a transformer-based image encoder on millions of surgical images curated from 11,965 internet-sourced surgical videos spanning ~2,900 hours and more than fifteen procedure types. Our training recipe inherits DINOv3's pretraining stage to preserve representation ability after surgical adaptation, and additionally applies a learned feature-upsampling module for high-resolution dense prediction at low token cost. Across a benchmark covering workflow, instrument and anatomy recognition, segmentation, detection, and monocular depth, under the same architecture, the largest InnerLogic-Surg model achieves the best linear-probe performance in all 20 surgical tasks. We demonstrate that surgical continual pretraining yields transferable representations that generalize across procedures, anatomical regions, and task types, showing our surgical image encoders as a promising and scalable alternative to the procedure-specific representation learning approaches that have traditionally dominated surgical computer vision.

0.25

CNsEMD: An Expert-Annotated Multi-Field-Strength MRI Dataset and a Hyperspherical Manifold Network for Multimodal Cranial Nerve Parcellation

cs.CV ·2026-09-07 ·Lei Xie, Junxiong Huang, Guoqiang Xie, Jiawei Zhang, Jiahao Huang +7 more
benchmarkdataset similarity 0.58
Abstract

Cranial nerves (CNs) play essential roles in sensory, motor, and autonomic functions. Accurate CN parcellation from multimodal magnetic resonance imaging (MRI) is crucial for neuroanatomical analysis and neurosurgical planning. However, accurate CN parcellation remains extremely challenging because CNs are very small, exhibit low image contrast, and have slender tubular morphologies and complex anatomical trajectories. Moreover, the lack of publicly available, expert-annotated datasets has impeded the development and fair benchmarking of learning-based CN analysis methods. In this work, we introduce CNsEMD, an expert-annotated multimodal dataset for CN parcellation. It comprises data from 202 subjects acquired on 3T, 5T, and 7T MRI scanners. We further propose the projective hyperspherical manifold network (PHM-Net), which learns cross-modal representations by capturing angular relationships in a shared hyperspherical embedding space. Rather than performing multimodal fusion in Euclidean space, the proposed Hyperspherical cross-modal interaction (HCI) module enables bidirectional feature exchange between T1-weighted (T1w) and direction-encoded color (DEC) representations on a unit hypersphere. The Magnitude-preserving projective hyperspherical orientation representation (PHOR) captures the axial nature of DEC orientations while preserving diffusion magnitude. The hyperspherical prototype segmentation head (HPSH) further extends angular similarity to voxel-wise classification using normalized voxel embeddings and learnable class prototypes. Extensive experimental results on the CNsEMD dataset demonstrate the effectiveness of our PHM-Net against state-of-the-art methods. CNsEMD establishes a reproducible benchmark for multimodal CN imaging, while PHM-Net provides a geometry-consistent solution for CN parcellation across diverse MRI acquisitions.

0.16

Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow Integration

cs.CV ·2026-10-15 ·Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
top venue similarity 0.56
Abstract · This version was submitted to MICCAI 2026 for review, see journal reference for published version

Markerless intraoperative tracking of spinal anatomy via RGB-D sensors is a promising alternative to invasive bone-anchored fiducials, yet no existing clinical dataset provides independent subsurface ground truth for validating these methods. We address this gap with a clinically viable pipeline that derives per-vertebra 6-DoF pose from routine intraoperative C-arm fluoroscopy, co-registered to the RGB-D camera frame through a multimodal fiducial array detectable in both imaging modalities. Critically, the pipeline requires no additional radiation, instrumentation, or deviation from standard surgical workflows, relying solely on the fluoroscopic images already acquired during routine level checks. A calibrated transform chain links the vertebral pose recovered via multi-view 2D-3D CT-to-fluoroscopy registration to the RGB-D coordinate frame, enabling direct comparison of any markerless registration estimate against a subsurface reference. Ex vivo validation against optically tracked ovine vertebrae confirms end-to-end accuracy of 2.06 +- 0.29 mm and 3.35 +- 0.93 degrees, sufficient to serve as independent ground truth for methods with substantially larger errors. We demonstrate the pipeline's utility by evaluating two markerless registration strategies on clinical data spanning 11 vertebrae across 1,500 frames from three surgical sequences: the first such evaluation against an independent subsurface reference in a clinical setting. The proposed framework provides reusable infrastructure for benchmarking emerging markerless tracking methods on real surgical data.

0.42

Uncovering the Invisible in Routine Radiology: Cross-Modal Detection of MRI-Verified Soft-Tissue Pathologies from CBCT via Physics-Guided 3D Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-11-17 ·Evgeny Alves Limarenko
similarity 0.56
Abstract

Routine X-ray modalities like cone-beam computed tomography (CBCT) are optimized for high-contrast mineralized tissues, leaving soft-tissue abnormalities buried beneath photon noise and below human visual perception. Thus, detecting non-calcified pathologies requires secondary magnetic resonance imaging (MRI). We demonstrate that sub-visual radiographic signatures of soft-tissue pathology are physically preserved within routine CBCT scans and can be extracted for opportunistic screening using a targeted, physics-guided deep learning pipeline, even under extreme paired-data scarcity. Using the temporomandibular joint (TMJ) as a model system (N = 212 paired CBCT-MRI joints), we address the severe overfitting of high-capacity 3D networks through a two-stage framework. First, we employ a frozen full-grid 3D masked autoencoder (BertsWin) pre-trained on 6,550 unlabeled CBCT volumes via the GradientConductor (GCond) optimizer and an anatomy-aware objective (PhysLoss) redirecting gradient flow into the [-300, 300] HU soft-tissue window. Second, automated localization of the condylar zenith drives a deterministic 3D cropping that eliminates 81% of background osseous variance. Evaluated via a patient-isolated 3x10-fold stratified cross-validation protocol, a statistically robust sub-visual signal for MRI-verified synovial effusion (ROC AUC = 0.793) emerges exclusively from representations pre-trained with the PhysLoss and GCond regime. Crucially, only this setup captures true 3D anatomical chirality (p < 0.001) and high intra-patient structural consistency (0.791) over inter-patient noise; conversely, identical architectures pre-trained with standard L2 loss or unmasked variance decomposition (MVC) collapse to random guessing. These findings establish a generalizable paradigm for repurposing routine, low-contrast radiographic scans into opportunistic screening tools for occult soft-tissue disease.

0.18

NeuroRefiner: Morphology-Aware Multi-Agent Refinement for 3D Fluorescence Microscopy Neuron Segmentation

cs.CV cs.AI ·2026-08-10 ·Haiyang Yan, Jinyue Guo, Yanchao Zhang, Bingqing Wang, Zhenchen Li +4 more
top venue similarity 0.56
Abstract · Accept by ECCV 2026

Accurate 3D neuron segmentation in fluorescence microscopy is critical for neuroscience. However, the sparse and elongated morphology of neurons poses significant challenges to existing segmentation methods. These methods struggle to preserve both local details and global topology, leading to fragmented results. To address this, we propose NeuroRefiner, a multi-agent system that formalizes the human expert workflow involving iterative global observation and local editing. Specifically, NeuroRefiner comprises three collaborative agents dedicated to diagnosing topological errors, generating correction instructions, and validating refinement quality. To facilitate agent instruction-guided segmentation refinement, we propose TopoRefineNet, a dedicated 3D U-Net-based tool that leverages cross-modality feature fusion to generate refined masks. Through multi-round agent reasoning and voxel-level editing, NeuroRefiner produces topologically more accurate segmentations with enhanced interpretability. Experiments on the BigNeuron, CWMBS, and ZBFWB datasets demonstrate that NeuroRefiner outperforms state-of-the-art methods, notably achieving a 3.02% improvement in F1 score on the challenging ZBFWB dataset.

0.34