CS Paper Radar

CRISP: Corneal Confocal Microscopy Real-Time Image Stitching Pipeline

Qincheng Qiao, Puli Zhang, Jian Zhou, Xinguo Hou

cs.CV ·submitted 2026-09-07 11:00 UTC · v2
code/data

Abstract

Morphology of the sub-basal nerve plexus (SNP) reflects peripheral nerve health, and corneal confocal microscopy (CCM) provides an important means for in vivo, real-time, non-invasive observation of the SNP. However, mainstream CCM devices offer a limited field of view per frame, whereas the SNP is spatially non-uniform; discrete image sampling is therefore sensitive to sampling location and frame selection, which limits the reproducibility and clinical adoption of CCM as a quantitative assessment tool. Wide-field stitching can reconstruct larger SNP mosaics by integrating sequentially acquired CCM images, but existing methods largely rely on offline post-processing, additional hardware, or specific acquisition protocols, and lack open-source real-time solutions for conventional CCM video streams. This paper presents CRISP (Corneal confocal microscopy Real-time Image Stitching Pipeline), an open-source real-time SNP wide-field stitching framework for conventional CCM examination video streams. CRISP excludes defocused and discontinuous segments via focus-aware gating, propagates poses through local pairwise registration, and maintains non-redundant spatial coverage with a sparse anchor map; when local temporal continuity is interrupted, the system completes relocalization and subgraph merging through global appearance retrieval followed by geometric verification. The framework prioritizes low-latency coverage feedback during examination while outputting accepted frames, poses, and anchor information to initialize offline fine stitching. To our knowledge, CRISP is the first open-source real-time SNP wide-field stitching framework released for conventional CCM video streams. By lowering the barrier to adoption and reproduction of wide-field stitching, CRISP may help move SNP wide-field imaging from a research tool into routine clinical examination workflows.

Comment
7 pages, 2 figures. Code: https://github.com/SummerColdWind/CRISP

Closest papers

Nearest neighbours by meaning across the whole index.

Label-Free Deep-Tissue Peripheral Nerve Detection with a Handheld Multimodal OCT Probe and NerveDetNet

cs.CV physics.opticsphysics.med-ph ·2026-08-13 ·Yihan Wang, Ruilin You, Shaobai Li, Jiabin Chen, Bofan Song +2 more
similarity 0.59
Abstract

Peripheral nerves buried beneath intact tissue are difficult to visualize during surgery and remain inaccessible to white light wide-field imaging and other surface optical imaging methods. Existing OCT nerve studies have largely relied on exposed nerves or polarization contrast with limited depth penetration, restricting their value for subsurface intraoperative guidance. Here, we introduce, to our knowledge, the first label-free framework for detecting peripheral nerves beneath unopened tissue and resolving their depth using intensity-based OCT structural signatures alone. The framework combines a handheld multimodal probe, integrating swept-source OCT with co-registered white light and autofluorescence imaging, with a ``confirm-then-capture'' workflow designed for practical surgical use. To enable efficient analysis of sparsely sampled OCT volumes, we develop NerveDetNet, a lightweight 2.5D segmentation network that recovers weak and spatially displaced nerve signals by incorporating spatial context, frame-order information, and shift-tolerant correlations across frames through a dedicated nerve feature correlation module. In ex vivo tissue experiments, NerveDetNet consistently outperformed six representative 2D baselines across all frame spacings, achieving a Dice score of 0.725 under the sparsest sampling condition while using approximately half the model parameters. End-to-end validation demonstrated localization of nerves invisible at the surface and depth-resolved detection up to 1.3--1.4~mm below the tissue surface, with OCT derived depth maps overlaid directly onto the surgical view. Together, these results establish a practical label-free approach for subsurface nerve visualization that supports intraoperative compatibility, enables efficient sparse-volume analysis, and provides depth-resolved guidance without tissue opening, contrast agents, or nerve exposure.

0.04

ARCOS: Zero-shot Boundary Localization for Corneal Layer Segmentation Across Optical Coherence Tomography Devices

cs.CV ·2026-09-03 ·Nuno Vivas Brás, Benjamin Memmi, Maëlle Bouhassane, Cristina Georgeon, Vincent Borderie +2 more
similarity 0.58
Abstract · 18 pages, 9 figures, 7 tables

Accurate segmentation of corneal layers in optical coherence tomography (OCT) is essential for quantitative assessment of corneal morphology, including layer thickness and structural changes associated with disease or surgery. However, automatic segmentation remains challenging because corneal interfaces are thin, affected by speckle noise, and variable across acquisition devices. In this work, we propose ARCOS, a patch-based zero-shot boundary localization framework for corneal layer segmentation in clinical anterior-segment OCT images. Rather than performing conventional region classification, the method predicts boundary heatmaps for the main corneal interfaces from overlapping native-resolution patches. Patch-level predictions are stitched across the full B-scan and converted into boundary locations to obtain continuous, anatomically ordered layer segmentations. The network combines multi-scale feature fusion with a self-conditioned refinement module that uses intermediate boundary information to improve local heatmap predictions while preserving spatial detail. The method was evaluated on clinical OCT images acquired from multiple devices and compared with representative segmentation baselines using boundary localization and derived thickness metrics. The proposed method achieved an off-by-one boundary localization accuracy of 95.1% and a mean absolute boundary error of 0.514 pixels on the matched-device test set. In zero-shot cross-device evaluation, it maintained an average off-by-one accuracy of 84.3% and a mean absolute boundary error of 0.855 pixels across unseen acquisition devices, outperforming the baseline models. Thickness estimates derived from the predicted boundaries showed low error across corneal regions, supporting the method's use for quantitative corneal OCT analysis.

0.28

MicroSplat: Towards Automating 3D Small-Scale Reconstruction

cs.RO ·2026-09-28 ·Roman Mineyev, Robert Azarcon, Suvrat Jain, Chuizheng Kong, Shreyas Kousik
similarity 0.55
Abstract

Reconstructing sub-millimeter detail of small objects underpins tasks such as circuit-board defect detection, specimen digitization, and archiving. 3D Gaussian Splatting (3DGS) makes photorealistic reconstruction possible from posed images alone, but macro optics violate two conditions it depends on. The field of view (FOV) and the depth of field (DoF) shrink to millimeters, so viewpoint error can take a sample out of frame, and only a thin focal plane is sharp in frame. Existing automated macro-capture rigs handle the shallow DoF with per-view focus stacking, but typically rely on classical photogrammetry and offline, human-in-the-loop processing. We present MicroSplat, which generates a 3DGS using a low-cost consumer microscope on a manipulator arm. After a single up-front object-localization step, the system runs unattended. It performs calibration, plans collision-free viewpoints, captures and fuses a focal stack at each viewpoint, segments the object across all views, and optimizes a 3DGS model warm-started with the arm's own poses. We further compare against blur-aware 3DGS methods, which infer sharp scenes from defocused images, and find that measuring sharpness with a controlled focal sweep outperforms inferring it. We provide real and synthetic datasets (including robot and camera parameters) and the fitted 3DGS reconstructions.

0.28

Automatic Field-of-View Adjustment for a View-Expansive Microscope via LSTM-Based Gaze and Pipette Motion Interpretation

cs.HC cs.LGcs.ROeess.IV ·2026-08-11 ·Kenta Yokoe, Takuya Hara, Tadayoshi Aoyama
published similarity 0.55
Abstract · This is the accepted version of an article published in IEEE Access 13, 182915-182923 (2025). DOI: 10.1109/ACCESS.2025.3624246. Open Access …

Intracytoplasmic sperm injection (ICSI) operators frequently adjust the field-of-view (FOV) during procedures, which interrupts workflow and increases procedure time. Conventional microscopes require manual objective lens switching and illumination adjustments to achieve different FOV sizes. We propose an AI-based automatic FOV adjustment method integrated with a view-expansive microscope. This microscope enables the simultaneous acquisition of a large FOV and high-resolution images using a single objective lens through multiview imaging with galvanometer mirrors and high-speed vision, thereby eliminating the need for physical lens exchanges. Our method utilizes a long short-term memory (LSTM) model to predict the appropriate FOV size based on real-time analysis of the pipette's position and velocity, combined with the operator's gaze position. The AI model is trained using ICSI procedure data from an expert with over five years of micromanipulation experience. Experimental evaluation with novice operators reveals that the proposed automatic FOV adjustment system significantly improves the ICSI procedure speed, reducing the average task completion time from 60.5 to 48.0 s (p < 0.001). The experiments also demonstrate that this improvement enables novice operators to achieve ICSI working speeds equivalent to those of expert operators.

0.62

Braided Vision Transformer for Stroke Detection in Multi-view Retinal Fundus Imaging

cs.CV ·2026-08-12 ·Aysen Degerli, Mika Hilvo
similarity 0.54
Abstract

Stroke remains a leading cause of mortality and morbidity worldwide, emphasizing the importance of its accurate and immediate assessment. Retinal fundus imaging has emerged as a promising modality for stroke assessment, as the retina reflects cerebrovascular and neurological risk factors. Contrary to conventional neuroimaging techniques, retinal fundus imaging offers a non-invasive, cost-effective, and portable alternative for rapid screening. This paper explores the feasibility of retinal fundus imaging for stroke and transient ischemic attack (TIA) detection using macula-centric and optic nerve head-centric views captured from both eyes. Our study introduces, to the best of our knowledge, the first vision transformer model for retinal fundus imaging in stroke assessment, offering a novel approach for capturing retinal patterns. Thereby, we propose the Braided Vision Transformer (BViT) model, which extracts representative features from the given multi-view images while simultaneously capturing inter-view relationships across both eyes, enabling a more informative understanding of retinal biomarkers associated with cerebrovascular events. Experiments conducted on our collected Stroke-Data dataset demonstrate that BViT achieves an AUC score of 0.75 for stroke detection, outperforming regular vision transformers.

0.04

TransGHOST: Real-Time, Synthesis-Free Reconstruction of Instrument-Occluded Regions in Ophthalmic Microsurgery

eess.IV cs.AIcs.CVcs.RO ·2026-11-10 ·Niran Nataraj, Maina Sogabe, Masamichi Yamashita, Norihiko Ito, Kenji Kawashima
similarity 0.54
Abstract · 20 pages, 10 figures, 11 tables

Intraoperative scene perception in ophthalmic microsurgery is limited by instrument occlusion: when a tool enters the high-magnification field, it conceals tissue from both the surgeon and the perception components of robot-assisted systems that process the video. Generative inpainting can remove the occluder but replaces the missing image content with synthesis, which is unsuitable when visual provenance matters. Many video inpainters also depend on future frames and cannot operate online. We present TransGHOST, a causal reference-guided reconstruction pipeline whose non-generative safe mode operates in real time. Every restored value is obtained by resampling a recorded frame using geometric transforms fitted only to visible regions. The system provides per-pixel confidence and provenance and marks unsupported pixels as abstentions. We evaluate TransGHOST on a new veterinary clinical corpus of canine cataract surgery with pixel-level instrument and anatomy labels. Only the occluded region is scored, and each scoring target is verified to differ from the reference supplied to the system. Safe mode reaches 31.89 dB masked PSNR and 0.915 masked SSIM at 51.7 ms median and 85.5 ms 95th-percentile latency. On a pre-declared held-out cohort using instrument cutouts excluded from segmentation training, it reaches 29.83 dB masked PSNR, while matched-mask evaluation on validation shows a 3.45 dB advantage over LaMa. Region-aware reference selection improves masked PSNR by 3.60 dB over recency when candidate references can themselves be occluded. Reference-age analysis further defines the operating interval for the brief, repeated occlusions targeted by TransGHOST.

0.26

CasDeblurGS: Cascaded 2D-to-3D Multi-View Consistency for 3D Gaussian Splatting from Two Blurry Images

cs.CV ·2026-08-11 ·Haeyun Choi, Minhyuk Jang, I-Gil Kim
publishedcode/data similarity 0.53
Abstract · Accepted to the ECCV 2026 MUSTCV Workshop. Project page: https://haeyun-choi.github.io/Cascaded2D3D_page/

Free-viewpoint 3D scene media is increasingly important for immersive applications, yet practical capture often suffers from severe view sparsity and motion blur. Although neural rendering has advanced sparse-view synthesis, existing blur-aware methods typically require substantial multi-view redundancy, accurate camera poses, or costly per-scene optimization. We address a stringent yet practical setting: reconstructing a coherent 3D scene from only two motion-blurred images with known intrinsics, without input-view poses, auxiliary sharp images, or per-scene test-time optimization. To this end, we propose CasDeblurGS, a cascaded framework that progressively recovers reliable cross-view information from local 2D correspondences to global 3D guidance. Stage 1 constructs locally reliable guidance through occlusion-aware correspondence filtering, while Stage 2 aggregates the intermediate restorations into a provisional pose-free 3D Gaussian representation whose input-view re-renders provide dense global guidance for final restoration. The resulting views enable a more coherent 3D representation and higher-quality novel-view synthesis. Experiments on real-world and synthetic Deblur-NeRF scenes show consistent gains over strong baselines, improving PSNR by 1.19 dB and 2.11 dB, respectively. Progressive ablations, cross-view correspondence visualization, and camera reprojection analysis further demonstrate improvements in both rendering quality and multi-view geometric consistency.

0.36

CGDD-Net: Context-Guided Dynamic Detail Modeling for Retinal Vessel Segmentation

cs.CV ·2026-10-04 ·Xincheng Li, Xiaoqi Sheng, Xinyu Zhang
code/data similarity 0.52
Abstract

Accurate retinal vessel segmentation requires features that capture vascular geometry while preserving information for fine-scale reconstruction. We propose CGDD-Net, a context-guided dynamic detail modeling network that connects adaptive feature extraction to a shared decoder pathway. Context-Guided Scale-Adaptive Deformable Encoding (CSDE) combines fixed-grid convolution with deformable local attention to capture vascular patterns at multiple spatial extents. Spatially Adaptive Multi-Kernel Gating (SAMG) selects receptive-field responses at each location. Dynamic Cross-Scale Detail Fusion (DCDF) aligns the gated intermediate features and compresses them into an eight-channel representation, which is reused at three decoder resolutions together with selected encoder skips. This design consolidates intermediate information before decoding instead of transferring each middle-stage feature through a separate direct skip. On DRIVE, CHASE\_DB1, STARE, and HRF, CGDD-Net achieves AUC values of 0.9824, 0.9938, 0.9895, and 0.9874, with F1 scores of 0.8323, 0.8102, 0.8510, and 0.8157, respectively. The complete model contains 1.96 million trainable parameters. In cumulative ablations, the full model improves F1 over the internal baseline by 2.48, 0.61, and 3.49 percentage points on DRIVE, CHASE\_DB1, and STARE. Twelve directed cross-dataset experiments further characterize transfer without target-domain adaptation. The results support shared intermediate detail delivery as an effective, parameter-compact architecture for retinal vessel segmentation. Code is available at \url{https://github.com/lixincheng-xcl/CGDD-Net}.

0.18