Abstract

Accurate segmentation of corneal layers in optical coherence tomography (OCT) is essential for quantitative assessment of corneal morphology, including layer thickness and structural changes associated with disease or surgery. However, automatic segmentation remains challenging because corneal interfaces are thin, affected by speckle noise, and variable across acquisition devices. In this work, we propose ARCOS, a patch-based zero-shot boundary localization framework for corneal layer segmentation in clinical anterior-segment OCT images. Rather than performing conventional region classification, the method predicts boundary heatmaps for the main corneal interfaces from overlapping native-resolution patches. Patch-level predictions are stitched across the full B-scan and converted into boundary locations to obtain continuous, anatomically ordered layer segmentations. The network combines multi-scale feature fusion with a self-conditioned refinement module that uses intermediate boundary information to improve local heatmap predictions while preserving spatial detail. The method was evaluated on clinical OCT images acquired from multiple devices and compared with representative segmentation baselines using boundary localization and derived thickness metrics. The proposed method achieved an off-by-one boundary localization accuracy of 95.1% and a mean absolute boundary error of 0.514 pixels on the matched-device test set. In zero-shot cross-device evaluation, it maintained an average off-by-one accuracy of 84.3% and a mean absolute boundary error of 0.855 pixels across unseen acquisition devices, outperforming the baseline models. Thickness estimates derived from the predicted boundaries showed low error across corneal regions, supporting the method's use for quantitative corneal OCT analysis.

Comment
18 pages, 9 figures, 7 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Automated 2D and 3D Segmentation of AMD and DME Lesions in OCT

cs.CV ·2026-08-27 ·Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri
similarity 0.58
Abstract

Age-related macular degeneration (AMD) and diabetic macular edema (DME) are leading causes of vision loss, and optical coherence tomography (OCT) is the standard modality for detecting and monitoring the subtle lesions that drive treatment decisions. Most deep-learning segmentation work for OCT is validated only in-domain, leaving generalization to clinical data collected under different acquisition protocols largely untested. This work develops and systematically ablates four lesion-segmentation pipelines -- 2D and 3D variants for AMD and DME -- reaching Dice scores of 0.76 to 0.82 with strong volumetric and surface calibration (r vol, r surf greater than or equal to 0.97 across all four pipelines) on an in-domain validation set. The ablation process establishes a full-volume, calibration-aware adoption standard that catches mechanisms an ordinary slice-level evaluation would keep, and identifies ensemble composition as the most consistent driver of improvement. To test generalization, the models are evaluated on OLIVES, an external clinical cohort with no lesion-level ground truth, using a proxy-metric framework built around biomarker AUROC, central subfield thickness (CST) correlation, and longitudinal concordance. Predictions track clinical biomarkers outside the training distribution, though less strongly than in-domain -- evidence for, not validation of, automated lesion-burden tracking as a clinical tool.

0.25

CNN-Based Retinal OCT Classification: Research Gap Analysis and a From-Scratch Baseline, ED126-A

cs.CV cs.LG ·2026-11-01 ·Shkelqim Sherifi
benchmark similarity 0.58
Abstract · 18 pages, 26 figures

Automated classification of retinal pathologies from Optical Coherence Tomography (OCT) images remains challenging because diagnostically relevant morphological patterns may exhibit substantial inter-class similarity. Although high classification accuracies have been reported on benchmark OCT datasets, cross-study comparison is limited by heterogeneous evaluation protocols and by the limited characterization of compact convolutional neural network (CNN) baselines trained from random initialization. This study addresses this gap through two contributions. First, it provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled benchmarking. Second, it presents ED126-A, a purpose-built four-class CNN baseline trained from scratch under a documented experimental protocol on the Kermany labeled OCT dataset. The model contains 1,241,380 total parameters, including 1,239,460 trainable parameters, and is evaluated using training-dynamics analysis, class-wise performance metrics, confusion-matrix analysis, confidence analysis, t-SNE representation-space visualization, Grad-CAM, hierarchical feature-map analysis, and one-vs-rest ROC/Precision-Recall analysis. On the image-level held-out test set, ED126-A achieved 95.03% accuracy, with a macro-F1 of 0.9205 and a weighted-F1 of 0.9521. The principal class-conditional limitation occurred for Drusen, which attained a recall of 0.9605 but a precision of 0.7493 and an F1-score of 0.8419. The confusion matrix identified Normal to Drusen and CNV to Drusen as major error channels. These results support the use of ED126-A as a documented from-scratch reference baseline and provide an empirical basis for controlled evaluation of transfer learning, increased depth, attention, multi-scale feature fusion, and calibration in subsequent studies.

0.30

CRISP: Corneal Confocal Microscopy Real-Time Image Stitching Pipeline

cs.CV ·2026-09-07 ·Qincheng Qiao, Puli Zhang, Jian Zhou, Xinguo Hou
code/data similarity 0.58
Abstract · 7 pages, 2 figures. Code: https://github.com/SummerColdWind/CRISP

Morphology of the sub-basal nerve plexus (SNP) reflects peripheral nerve health, and corneal confocal microscopy (CCM) provides an important means for in vivo, real-time, non-invasive observation of the SNP. However, mainstream CCM devices offer a limited field of view per frame, whereas the SNP is spatially non-uniform; discrete image sampling is therefore sensitive to sampling location and frame selection, which limits the reproducibility and clinical adoption of CCM as a quantitative assessment tool. Wide-field stitching can reconstruct larger SNP mosaics by integrating sequentially acquired CCM images, but existing methods largely rely on offline post-processing, additional hardware, or specific acquisition protocols, and lack open-source real-time solutions for conventional CCM video streams. This paper presents CRISP (Corneal confocal microscopy Real-time Image Stitching Pipeline), an open-source real-time SNP wide-field stitching framework for conventional CCM examination video streams. CRISP excludes defocused and discontinuous segments via focus-aware gating, propagates poses through local pairwise registration, and maintains non-redundant spatial coverage with a sparse anchor map; when local temporal continuity is interrupted, the system completes relocalization and subgraph merging through global appearance retrieval followed by geometric verification. The framework prioritizes low-latency coverage feedback during examination while outputting accepted frames, poses, and anchor information to initialize offline fine stitching. To our knowledge, CRISP is the first open-source real-time SNP wide-field stitching framework released for conventional CCM video streams. By lowering the barrier to adoption and reproduction of wide-field stitching, CRISP may help move SNP wide-field imaging from a research tool into routine clinical examination workflows.

0.43

Comparative Evaluation of Deep Learning Models for Geographic Atrophy Segmentation in En Face OCT Images

cs.CV ·2026-11-09 ·Utkarsh Doshi, Adarsh Gadari, Sharat Chandra Vupparaboina, Joseph DeCicco, Giulia Gregori +7 more
similarity 0.57
Abstract · 30 pages, 11 figures

Background: Geographic atrophy (GA) is an advanced form of age-related macular degeneration (AMD). It causes irreversible vision loss due to progressive degeneration of the retinal pigment epithelium (RPE) and photoreceptors. Accurate segmentation of GA in en-face image is crucial for early diagnosis, monitoring disease progression, and developing personalized treatment strategies. However, existing deep learning approaches are typically evaluated using single architectures and single-device datasets, limiting insight into relative performance and cross-device robustness. Methods: We trained and systematically compared five deep learning architectures for GA segmentation: Nested U-Net, ResU-Net, nnUnet, Swin-Unet and MedSegDiff model, together with a thresholding based classical baseline. The models were trained on a dataset of en-face OCT images derived from 269 OCT volumes from two different devices, following a three-step preprocessing technique involving normalization and inpainting to enhance the quality of the en-face images. Results: On the fixed held-out validation set comprising OCT scans from both Cirrus (R) (Carl Zeiss Meditec, Inc., USA) and Spectralis (R) (Heidelberg Engineering, Germany) devices, nnUnet achieved the highest mean Dice similarity coefficient (DSC) of 0.8882 +/- 0.0033. The other models yielded the following Dice scores: Nested U-Net (0.7932 +/- 0.0423), ResU-Net (0.8453 +/- 0.0074), Swin-Unet (0.6886 +/- 0.0294), and Diffusion model (0.7959 +/- 0.0242). Conclusions: nnUnet framework, demonstrated most reliable performance for GA segmentation in en-face OCT under limited data conditions. It offers the best balance of accuracy, stability, and efficiency for GA quantification.

0.20

Optic Disc Segmentation in Fundus Images: From Classical Image Processing and Deformable Models to Modern AI

eess.IV cs.CV ·2026-08-18 ·Buket D. Barkana
similarity 0.57
Abstract

Accurate localization and segmentation of the optic disc (OD) are important for retinal image analysis and glaucoma assessment, yet remain challenging due to variations in illumination, pathology, vascular interference, and poorly defined boundaries. This structured methodological review examines the evolution of OD segmentation from classical image-processing and deformable models to contemporary artificial intelligence (AI)-based approaches. A structured literature search and study-selection process was used to identify representative studies spanning major methodological developments. The review first summarizes commonly used fundus-image datasets, then organizes classical methods by principal mechanisms, including intensity and thresholding, histogram and entropy analysis, morphology, geometric and Hough-transform methods, filtering and feature operators, texture- and region-based approaches, and active-contour and level-set models. This paper pays particular attention to the assumptions, strengths, limitations, and complementary roles of these methods in OD localization and boundary delineation. Representative AI approaches are subsequently examined to illustrate the transition from handcrafted features and explicitly defined priors to learned representations, Transformer-based segmentation, boundary- and shape-aware learning, promptable segmentation, and retinal foundation models. Across these methodological generations, several core segmentation principles persist, including region-of-interest localization, multiscale representation, geometric and anatomical constraints, and boundary regularization, although their implementation has shifted from predefined operators to learned modules, losses, prompts, and pretrained representations. The review further identifies boundary ambiguity, anatomical variability, domain shift, and cross-dataset generalization as continuing challenges.

0.27

Within-Family EfficientNet Scaling under Fixed-Resolution Transfer Learning for Spectral-Domain Optical Coherence Tomography Retinal Disease Classification

cs.CV cs.AIcs.LG ·2026-11-04 ·Shkelqim Sherifi
similarity 0.55
Abstract · 46 pages, 20 figures, 18 tables

Background/Objectives: CNNs perform well in retinal disease classification from spectral-domain optical coherence tomography (SD-OCT), but whether EfficientNet's natural-image scaling hierarchy transfers to medical-image transfer learning at fixed resolution remains unclear. This study evaluates EfficientNet-B0-B7 for four-class SD-OCT classification and accuracy-efficiency trade-offs. Methods: Eight ImageNet-pretrained variants (4.05-64.10M instantiated backbone parameters) were evaluated at 224x224 on the Kermany dataset. Grayscale images were replicated to RGB and processed using model-embedded preprocessing and augmentation. Training comprised frozen-backbone head training followed by partial fine-tuning. Metrics covered classification, discrimination, efficiency, and visual analyses. Results: Test accuracy varied non-monotonically from 95.93% (B0) to 96.95% (B1); B7 achieved 96.73%. B1 had the highest accuracy and Drusen F1 (0.8780), while B7 had Drusen F1 of 0.8720 and the highest Drusen recall (0.9177). Drusen had the lowest F1 across all variants and contributed 82.2% of the summed squared deviation in class-specific F1; class ranking remained Normal > CNV > DME > Drusen. The OCT accuracy ranking differed from the reported ImageNet hierarchy, where B7 ranked first. The accuracy-to-parameter ratio fell from 19.82 to 1.48 percentage points per million total parameters. The final train-test gap had a weak, non-significant association with test accuracy (r = 0.26, p = 0.53). Conclusions: Larger EfficientNet variants did not consistently improve SD-OCT classification. B1 achieved the highest accuracy and Drusen F1, whereas B7 showed a secondary accuracy recovery at greater model size and CPU latency, indicating task and protocol dependent scaling effects. As cross-partition duplicates have not been independently audited, results are conditional on the supplied split.

0.13

EA-LiteUNet: An Edge-Adaptive and Resource-Efficient U-Net for Boundary-Sensitive Dermoscopic Image Segmentation

cs.CV cs.AI ·2026-08-16 ·Wang Jiangtao, Nur Intan Raihana Ruhaiyem, Fu Panpan, Yang Yu, Huang Yan
similarity 0.55
Abstract · 29 Pages,13 figures, 8 tables

Accurate boundary delineation remains a persistent challenge in dermoscopic image segmentation because of blurred lesion margins, heterogeneous textures, and complex background artifacts. From a signal-processing perspective, lesion boundaries represent high-frequency components that are highly susceptible to aliasing, noise amplification, and information loss. Consequently, repeated downsampling and feature transformations in conventional convolutional architectures often lead to severely degraded boundary representations. To address these limitations, we propose EA-LiteUNet, an edge-adaptive and computationally efficient U-Net variant specifically designed for boundary-sensitive medical image segmentation. The architecture integrates three core mechanisms: (1) boundary-aware representation learning to suppress aliasing and preserve high-frequency structural details; (2) attention-guided feature modulation to selectively enhance boundary-relevant responses across multi-scale features; and (3) a resource-adaptive inference strategy to dynamically balance segmentation accuracy and computational efficiency. Extensive evaluations across three public dermoscopic datasets demonstrate that EA-LiteUNet consistently achieves superior boundary precision. Specifically, on the ISIC 2018 dataset, the method significantly reduces the 95% Hausdorff Distance (HD95) to 12.89 pixels while maintaining a robust Dice score of 92.08%. Notably, this strong performance is achieved with an ultralightweight configuration of merely 0.29M parameters and 1.17 GFLOPs. Ablation studies further validate the complementary effects of these components, confirming their contribution to enhanced boundary fidelity and stable optimization.

0.10

Beyond Accuracy: Uncertainty-Guided Boundary Refinement for Reliable Biomedical Image Segmentation

cs.CV cs.LG ·2026-09-11 ·Anima Kujur
similarity 0.55
Abstract

Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.