CS Paper Radar

Grid-Constrained State-Adaptive Particle Swarm Optimization: A Discrete and Efficient Heuristic Solver for Precise Harmonic Programming

Guangze Chen, Zhenbin Zhang, Yafei Yin

eess.SY ·submitted 2026-08-23 12:38 UTC · v1

Abstract

Harmonic programmed pulse width modulation (HPPWM), offering flexible harmonic regulation, is a promising solution for high-power energy conversion systems. However, most existing methods solve HPPWM in a continuous space while ignoring the finite timer resolution of practical digital controllers. This leads to a potential optimality deviation during deployment. Motivated by this, this paper proposes a Grid-Constrained State-Adaptive Particle Swarm Optimization (GCSA-PSO) strategy. By matching the solution space with practical timer constraints, GCSA-PSO directly searches for implementable pulse sequences in the discrete solution space, thereby improving deployment consistency while reducing the search burden. Moreover, a state-adaptive evaluation strategy is developed to assign different cost evaluations according to particle states, avoiding unnecessary evaluations and improving computational efficiency. Experimental data confirm that, compared with the classical method, the proposed method reduces the computational time while achieving higher control accuracy under practical digital-controller deployment.

Comment
10 pages, 9 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Optimal Allocation of Grid-Forming Frequency Shaping Control

eess.SY ·2026-09-21 ·Zhaomin Lyu, Ding Zhang, Yan Jiang
similarity 0.52
Abstract

Various inverter-based control strategies have been proposed to improve frequency security for power systems with high renewable penetration. Among them, the grid-forming frequency shaping control is particularly promising due to its ability to shape the post-contingency aggregate system frequency dynamics into first-order with prescribed rate of change of frequency (RoCoF) and steady-state frequency deviation. Moreover, the shaped aggregate dynamics depends on the harmonic sum of all inverter transfer functions rather than on their distribution. In light of this, here we explore how to allocate shaping control resources to minimize the transient control effort needed to achieve ideal coherent dynamics. We formulate it as a constrained optimization problem by tackling two main difficulties. First, we make the squared $\mathcal{H}_2$ norm legitimate quantification of transient control cost under step power imbalances through a system transformation. Second, we simplify the $s$-domain constraint for Nadir elimination into a standard constraint that is easy to implement in optimization. The resulting non-convex optimization problem can be solved by existing successive convexification method. The effectiveness of the allocation has been verified on the modified Icelandic Power Network test case.

0.28

Beyond Higher-Pulse Rectification: Operational Harmonic Coordination in Renewable P2H Systems

eess.SY math.OC ·2026-09-03 ·Yangjun Zeng, Yiwei Qiu, Jie Zhu, Yi Zhou, Tao Wu +4 more
similarity 0.51
Abstract

Thyristor rectifiers (TRs) are cost-effective electrolysis power supplies for renewable power-to-hydrogen (ReP2H) systems, but their harmonics may violate grid-code limits. In contrast to conventional solutions that rely on higher-pulse (such as 24-pulse) rectifiers, this paper proposes an operational harmonic coordination scheme that enables low-cost 12-pulse TRs to meet harmonic requirements through coordinated operation. First, a harmonic model quantifies the effects of rectifier transformer (RCT) tap positions and electrolytic currents, enabling harmonic cancellation among multiple electrolyzers (ELZs). A two-layer framework then coordinates hydrogen production and harmonic mitigation. Hourly scheduling determines ELZ commitment within the harmonic feasible region under renewable uncertainty using stochastic programming and a modified progressive hedging algorithm, while minute-level dispatch tracks renewable power and mitigates harmonics. A decomposition algorithm separates production dispatch from harmonic mitigation to improve computational efficiency. Case studies based on real-life projects show that the proposed method increases profit by 31% over current-only regulation. Annual simulations further show that coordinated 12-pulse TRs can replace 24-pulse rectifiers for harmonic compliance by exchanging additional RCT tap actions for lower transformer investment, reducing rectification-stage cost by 37.5%.

0.21

Water as a Battery: Using Hydropower Flexibility to Support the Grid

eess.SY ·2026-10-25 ·Chinmay Morankar, Abdullah Al Mehadi
published similarity 0.51
Abstract

This study presents a two-layer optimization framework to determine the optimal sizing of PV, wind, and battery storage co-located with existing hydroelectric plants to support rapidly increasing data center loads while minimizing cost, grid reliance, and transmission upgrades. The outer layer uses Particle Swarm Optimization (PSO) to select capacity combinations, while the inner layer performs rolling-horizon dispatch simulations to model hourly energy balance among PV, wind, hydro, and BESS, considering operational constraints. Two case studies were analyzed. At The Dalles Dam (Oregon), favorable wind resources and land availability enabled deployment of 111.2 MW PV and 117.9 MW wind, with no BESS required. Hydro flexibility allowed the system to meet the load with minimal grid support. In contrast, Conowingo Dam (Maryland) faced land constraints and limited renewables to 130 MW PV, leading to higher grid dependence. Co-locating hydro with renewables significantly enhances reliability and cost effectiveness by leveraging hydro's dispatchability to balance daily and seasonal variable generation from PV + Wind, reducing the need for storage or costly grid imports. This analysis provides a framework to meet the 99.9% availability targets of this new load type on the grid with sustainable energy resources.

0.32

On the Structural Optimization of Industrial Control Systems Using Metaheuristic Algorithms

eess.SY ·2026-10-10 ·Ruslan Zakirzyanov
published similarity 0.49
Abstract

The paper addresses the synthesis of a cost-optimal hardware architecture of the automated process control system (APCS) for continuous processes. The problem is formalized as the search for a minimum-cost rooted tree of devices subject to constraints on the number of I/O channels, the types and number of communication interfaces, the information capacity of processors, the regulation time and the reliability. The signals are grouped by control rooms. The problem is NP-hard, and a hybrid method is proposed that combines a deterministic hierarchy construction with a modified ant colony optimization (ACO) for device-type selection, enhanced by an adaptive heuristic. On ten instances the method is compared with a genetic algorithm (GA), particle swarm optimization (PSO), simulated annealing (SA) and CP-SAT over 30 runs each. By the best found cost the hybrid ACO outperforms GA, PSO and SA on all instances with more than 100 IOs (by 14-38 %) and runs 9-14 times faster. By the median cost, however, the deterministic-greedy baselines are more reliable (GA attains the best Friedman rank) because the cost of the ACO runs is highly variable. All differences are confirmed by the Friedman and Wilcoxon tests. The method targets the early-design search for the cheapest feasible architecture and synthesizes one within minutes at industrial scale (A up to 1086).

0.34

Real-Time Operation Strategy of Virtual Power Plants With Optimal Power Disaggregation Among Heterogeneous Resources

eess.SY ·2026-08-27 ·Qixin Chen, Ruike Lyu, Hongye Guo, Xiangbo Su
publishedhot directionhighly cited similarity 0.48
Abstract · Accepted by Applied Energy

The virtual power plant (VPP) can aggregate flexible resources on the demand side to provide frequency regulation for the grid, helping address the supply-demand balance challenges. When deploying regulation, the VPP disaggregates the requested power adjustment in real time among its internal heterogeneous resources. Achieving optimal power disaggregation in this process is challenging due to the temporal coupling characteristics of the resources, the uncertain regulation signals, and the requirement for fast response. Therefore, existing research relies on heuristic methods, such as proportional disaggregation, and fails to leverage the heterogeneity of multiple resources. Here, we propose an optimal operation strategy for VPPs to provide regulation, exploiting the complementary characteristics of heterogeneous resources by prioritizing the use of low-cost resources while considering temporal coupling. To reduce the computational overhead of online deployment, we further propose a fast disaggregation algorithm to eliminate the reliance on optimisation solvers. We conducted case studies on the operation of a VPP composed of resources including thermostatically controlled loads and industrial production processes. The results verified the reduced operation cost and increased profit of the VPP under the proposed strategy, with only milliseconds of online computation time. We believe that our work can help better exploit demand-side flexibility.

0.62

Battery Energy Storage Sizing in PV Ramp-Rate Smoothing using Constraint-Aware Reinforcement Learning-Based Controller

eess.SY ·2026-11-13 ·Arash Omidi, Tanmay Mishra, Mads R. Almassalkhi
benchmark similarity 0.47
Abstract

This paper presents a constraint-aware reinforcement learning (CARL) controller for battery energy storage system (BESS) sizing and photovoltaic (PV) ramp-rate smoothing. Rapid PV power fluctuations caused by cloud transitions can introduce operational and stability challenges in power systems. To mitigate these impacts, grid codes impose ramp-rate limits (RRL) on PV power injected to the grid. BESSs can support such grid codes by absorbing or supplying power during rapid variations. However, the extent to which BESSs can reduce PV-induced variability depends on (i) the BESS power and energy capacities; and (ii) the adopted controller. Thus, BESS sizing and controller design are coupled. Conventional moving-average control can increase battery usage due to filter-induced lag, while ramp-rate control is reactive and does not account for the long-term impact of actions on battery state of charge and future ramp events. Optimization-based methods can reduce BESS requirements by anticipating future PV variations, but their performance depends on accurate PV forecasts. To address these limitations, the CARL controller learns a causal state-feedback policy from historical PV data without requiring forecasts during deployment. Ramp-rate, converter-power, and state-of-charge constraints are incorporated into a causal feasibility interval that guarantees feasible actions by definition. A full-horizon input-convex neural network (ICNN)-based optimization is developed as a noncausal benchmark for the minimum achievable BESS requirements. Evaluation using three real-world PV datasets shows that, at a 10\%/min ramp-rate limit, CARL reduces peak BESS power by 8.7--10.4\% and energy capacity by 47.5--62.6\% relative to conventional ramp-rate control while maintaining the grid-codes compliance.

0.20

Do Bio-Inspired Algorithms Save Energy in Data Centres? Separating Server Packing from Migration Search in Virtual Machine Consolidation

cs.DC cs.ETeess.SY ·2026-10-25 ·Yichiet Aun, Yu Hang Woo
similarity 0.47
Abstract · 38 pages, 8 figures, 6 tables. Data, source and analysis scripts: doi:10.5281/zenodo.23632346. Submitted to Simulation Modelling Practice an…

Energy-efficient virtual machine (VM) consolidation matters as data centre electricity demand rises. Bio-inspired metaheuristics, including ant colony optimisation (ACO), particle swarm optimisation (PSO), and genetic algorithms, have reported substantial energy savings. However, these improvements are commonly evaluated against conventional allocation policies that differ in both initial VM placement and subsequent migration optimisation, making it difficult to determine the contribution of metaheuristic search. This study reproduces an existing consolidation implementation in CloudSim Plus and introduces a matched control that retains the same initial packing and empty-host deactivation mechanisms but excludes migration search. ACO, PSO, and a modified genetic algorithm (MGA) are evaluated across two fleet configurations and four workload regimes, with ten stochastic replications per condition. The matched control achieves energy savings of 0.8-81.4% relative to the spreading baseline, the amount available falling sharply as load rises, without migrations or incomplete workload execution. Across 24 comparisons, metaheuristic search increases energy consumption in 11 cases, produces identical outcomes in seven, and reduces consumption in six. Of these, ten increases and five reductions remain statistically significant after Holm correction. Five of the six apparent reductions coincide with unfinished tasks and disappear after normalisation by delivered computational work. Only ACO under light heterogeneous load retains a 3.22-percentage-point improvement (95% CI 2.96-3.47). These findings demonstrate that initial packing and host deactivation account for most of the measured energy savings in the examined implementations, highlighting the importance of matched control conditions and workload-completion measures for reliable evaluation of VM consolidation algorithms.

0.32

Grid-Mode-Aware Model Predictive Control of Hybrid Energy Storage Systems for AI Data Center Power Smoothing

eess.SY ·2026-09-03 ·Xin Chen
similarity 0.46
Abstract

To facilitate the grid-friendly integration of highly variable AI data center loads, this paper proposes a grid-mode-aware model predictive control (G-MPC) framework for managing a hybrid energy storage system (HESS) to smooth grid-side power demand. The framework optimally coordinates a battery energy storage system (BESS) and a supercapacitor (SC) by solving a multi-step optimization problem in a receding-horizon manner. In particular, band-pass filter dynamics are directly embedded in the G-MPC formulation to extract and suppress grid-side power components associated with vulnerable grid oscillatory modes, thus mitigating load-induced grid oscillations. The resulting G-MPC optimization jointly minimizes violations of grid-side power-envelope, ramp-rate, and modal-power requirements and the degradation and power-ramping costs of the BESS and SC, while satisfying power limits, state-of-charge limits, and other operational constraints. To enable real-time implementation, a fix-and-re-optimize algorithm is developed to solve each G-MPC problem efficiently while preventing simultaneous charging and discharging. Extensive simulations demonstrate the effectiveness, flexibility, and computational efficiency of the proposed framework. The results also highlight the importance of explicitly suppressing power components associated with vulnerable grid modes, rather than merely reducing overall load variations, to effectively mitigate grid oscillations.

0.40