CS Paper Radar

Design of a Biomimetic Joint-Covering Skin with Tissue-Like Structure to Enhance Proprioception in a Musculoskeletal Humanoid

Akihiro Miki, Shun Hasegawa, Yoshimoto Ribayashi, Kento Kawaharazuka, Kei Okada

cs.RO ·submitted 2026-08-24 14:27 UTC · v2
published

Abstract

Proprioception in musculoskeletal humanoids is typically estimated primarily from muscle sensing, while the role of cutaneous deformation around joints remains insufficiently explored. In biological systems, mechanoreceptors distributed within soft tissue complement muscle feedback and support reliable joint state estimation. This study presents the design of a biomimetic joint-covering skin with a tissue-like layered structure that integrates pressure- and stretch-sensitive elements within the joint-covering tissue. The proposed skin is implemented on the musculoskeletal humanoid Musashi-W, and its independent proprioceptive capability as well as its integration with muscle sensing are evaluated. Experimental results show that the proposed skin alone achieves joint angle estimation with an average error of approximately 3 degrees. Furthermore, integration with muscle sensing improves estimation accuracy. Owing to its joint-covering structure, the skin may mechanically mitigate the influence of external disturbances on the muscles, and the integration of multiple modalities suggests the possibility of contributing to the identification of external stimuli that are difficult to interpret using muscle sensing alone. This work presents a design methodology for biomimetic joint-covering skin and demonstrates that such tissue-structured skin can serve as an effective approach for extending proprioceptive systems in musculoskeletal humanoids.

Comment
Accepted at IROS 2026, website - https://poyotamu000.github.io/musashiw-joint-covering-skin/ YouTube - https://www.youtube.com/watch?v=L9xU2wMkRRg

Closest papers

Nearest neighbours by meaning across the whole index.

Elbow Angle Guidance System Based on Surface Haptic Sensations Elicited by Lightweight Wearable Fabric Actuator

cs.HC cs.RO ·2026-08-11 ·Kenta Yokoe, Tadayoshi Aoyama, Yuki Funabora, Masaru Takeuchi, Yasuhisa Hasegawa
published similarity 0.59
Abstract · This is the accepted version of the paper published in Proc. 2024 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), …

The demand for wearable haptic devices has rapidly increased for various applications. However, many haptic devices interfere with the wearer's activities and movements. In addition, several haptic devices fail to elicit intuitive haptic sensations by adjusting to the natural posture of the wearer. To address these issues, we propose an elbow angle guidance system using a lightweight wearable fabric actuator. The proposed actuator is made of fabric and has two McKibben-type artificial muscles attached to it, rendering it extremely lightweight and facilitating the delivery of surface haptic sensations to intuitively induce elbow extension and flexion. The surface haptic sensation elicited by the fabric actuator is adjusted to natural body movements without interfering with the wearer's movements. Moreover, the proposed system measures and guides the elbow angle by changing the intensity of the surface haptic sensation delivered to users in real time. The accuracy of the proposed system is demonstrated through experiments involving human participants.

0.65

Robotic Physical Comparison of Biologically Motivated and Counterfactual Sensory Arrangements using Biomimetic Skin

cs.RO ·2026-10-19 ·Akihiro Miki, Shun Hasegawa, Yoshimoto Ribayashi, Yuta Sahara, Kento Kawaharazuka +1 more
publishedcode/data similarity 0.57
Abstract · Published in Bioinspiration & Biomimetics (IOP Publishing). Project page: https://poyotamu000.github.io/biomimetic-skin-sensory-arrangements…

Human skin contains diverse mechanoreceptors, including Merkel cells and Pacinian corpuscles, each localized in specific regions. Although their spatial organization is known to be shaped by molecular signaling and neural induction during development, experimentally examining its functional significance under controlled conditions in living systems remains challenging. In particular, physically comparing alternative receptor arrangements that do not occur biologically is difficult. In this study, we developed a layered biomimetic robotic skin designed to mimic key structural features of human skin tissue by embedding receptor-analog sensors within compliant soft media. Using this platform, we implemented both biologically motivated and counterfactual sensory arrangements and quantitatively evaluated their performance across three passive tactile tasks: detection of weak contacts, a two-point discrimination-like assessment, and texture identification. Arrangements reflecting key features of the biologically motivated sensory organization exhibited higher performance than the alternative configurations examined. This study addresses a biological question concerning how spatial organization influences tactile function by presenting a biomimetic robotic approach that enables physical and empirical comparison of biologically motivated and counterfactual sensory arrangements that are difficult to investigate in living systems.

0.61

Knit-Structure Effects on Electromechanical Metrics and Their Correlation with Joint-Angle Estimation Error in Knitted Strain Sensors

cs.HC ·2026-10-05 ·Annika Eloranta, Zhuchenyang Liu, Iiro Naulapaa, Iida Arvola, Yao Zhang +3 more
similarity 0.55
Abstract · 10 pages

Knitted resistive strain sensors show strong promise for joint motion sensing in sports and rehabilitation, but the linkage between sensor design and in situ performance remains unclear. We investigate how knit structure and machine settings (e.g., stitch size) shape electromechanical properties and which metrics predict sensing performance during bending. Sensors spanning seven common knit structures at two stitch sizes were fabricated, characterized under uniaxial cyclic tension, and evaluated on a joint emulating bending rig. Joint-angle estimation was assessed with machine learning models, and correlations with electromechanical metrics were analyzed. Experimental results show that, among six common metrics, gauge factor and baseline resistance are largely set by knit structure, while working range, linear range, hysteresis, and cyclic stability vary only modestly across designs. Gauge factor correlates negatively and baseline resistance positively with joint-angle estimation error, mainly in lower-sensitivity designs, whereas the other metrics have weak or no predictive value. These results support using uniaxial tensile tests to screen out weak designs, while underscoring the need for joint-relevant evaluation and application-specific metrics to identify top performers.

0.40

Anticipatory Textile MMG-Strain Sensing for Confirm-Then-Assist Soft Knee Exosuits

cs.RO ·2026-10-11 ·Zheng Ma, Xiao Jin, Zhenhua Yu
similarity 0.52
Abstract · 8 pages, 9 figures, 4 tables

Soft wearable robots must commit to assistance around movement onset, when the available signals are ambiguous. Surface electromyography (sEMG) detects neuromuscular drive early but degrades under sweat and electrode shift, and kinematic sensors respond only once the limb moves. This letter presents a knitted textile interface that co-samples a three-channel mechanomyography (MMG) array and an anterior strain sensor on a single synchronous 500 Hz clock. Across five participants, MMG activation preceded strain-detected knee motion during sit-to-stand by per-channel medians of 322-344 ms. Sampled on the same clock, the sign of the strain slope resolved movement direction on 649 of 650 completed transitions with no training or per-participant calibration, raising four-class balanced accuracy from 90.3% to 95.6%. The fused signals drove a two-stage confirm-then-assist policy for a soft pneumatic knee. Across 240 trials in four participants, the onboard controller entered the assist state on 78 of 80 sit-to-stand trials and on none of the 80 isometric co-contractions. It also entered the assist state on 27 of 80 stand-to-sit trials and left it at the hold timeout, motivating an antagonistic flexor gauge to resolve this direction at onset. Co-sampling muscle acoustics with textile strain on one clock lets the inflation command be issued around movement onset.

0.37

Haptic Probing for Subsurface-Aware Force Distribution on Layered Soft Tissue

cs.RO ·2026-11-17 ·Lei Shi, Xiaoyu Wang, Cheng Zhou, Yongjian Liu, Jing Wang +3 more
position similarity 0.52
Abstract

Force-regulated contact with layered soft tissue fails most often where the subsurface composition changes: controllers infer the substrate from the loading signal alone, so the estimate guiding them lags the change---more acutely, we argue, over compliant than over bone-backed tissue. We remove that lag with a separate haptic channel. Under a light preload, a brief low-amplitude excitation lets the local dynamic admittance discriminate muscle from bone-backed tissue relative to a per-subject baseline, before task force is applied---active haptic sensing used to commit a control decision rather than to characterise tissue. A force- and tactile-driven distribution law then consumes that regime throughout execution: an instantaneous allocation equalises pressure across the engaged fingertips, while the regime sets the admissible pressure and hence the area the hand must recruit to deliver the target force---making patch area a controlled variable rather than a by-product. Probing, switches and recruitment are priced in a partitioned passivity budget, so safety monitoring cannot suppress the probe and a refused recruitment forfeits force tracking rather than the pressure bound. We report force tracking and pressure uniformity over curved, migrating contact on three human subjects, with regime labels from anatomical landmarks.

0.21

A Wearable Pneumatic Device for Continuous, Closed-Loop, Bidirectional Tactile Interaction

cs.RO ·2026-09-01 ·Cosima du Pasquier, Aliyah Smith, Serin Huber, Joshua Phelps, Ilana A. Cohen +3 more
similarity 0.52
Abstract

We present a system of two wearable pneumatic haptic devices that supports continuous, closed-loop, bidirectional tactile interaction at perceptually relevant force and temporal scales. A single device can contain up to twelve pressure sensing channels connected to textile-based pneumatic pouches. Each channel in a device can be used as a sensor, an actuator, or both. As an actuator with integrated sensing, the channel generates stable skin indentation through local closed-loop control. As a sensor, a channel can be mounted (or worn) on any surface, including on a robot gripper or on the human body, and used to measure touch interactions with the environment or a human user. A distributed architecture supports sustained pressure output, rapid dynamic response, and wireless pairing of identical devices in a system to transmit and reproduce tactile pressure signals in real time. Device-level characterization demonstrates force bandwidth exceeding 30 Hz, rapid and well-damped step responses, and extended pressure retention compared to prior compact pneumatic platforms. Human studies show that pressure-based fingertip feedback enables discrimination of force and stiffness, improves teleoperated manipulation by reducing applied pressures by up to 23.1% and task duration by up to 27.4%, and lowers subjective mental workload by 18.8%, particularly under visually constrained conditions. By unifying tactile sensing and haptic feedback within a single pneumatic modality, the device provides a practical foundation for bidirectional touch interaction in teleoperation.

0.14

Intuitive Directional Sense Presentation to the Torso Using McKibben-Based Surface Haptic Sensation in Immersive Space

cs.HC cs.RO ·2026-08-10 ·Kenta Yokoe, Tadayoshi Aoyama, Yuki Funabora, Masaru Takeuchi, Yasuhisa Hasegawa
top venue similarity 0.52
Abstract · This is the accepted version of an article published in IEEE Transactions on Haptics 18(1), 244-254 (2025). DOI: 10.1109/TOH.2024.3522897. O…

In recent years, systems that utilize immersive space have been developed in various fields. Immersive spaces often contain considerable amounts of visual information; therefore, users often fail to obtain their desired information. Therefore, various methods have been developed to guide users toward haptic sensations. However, many of these methods have limitations in terms of the intuitive perception of haptic sensation and require practice for familiarization with haptic sensation. Fabric actuators are wearable haptic devices that combine fabric and McKibben artificial muscles to provide wearers with surface haptic sensation. These sensations can be provided to a wide area of the body with intuitive perception, instead of only to a part of the body. This paper presents a novel air pressure adjustment method for whole-body motion guidance using surface haptic sensations provided by a wearable fabric actuator. The proposed system can provide users with a directional sense without visual information in an immersive space. The effectiveness of the proposed system was evaluated through subject experiments and statistical data analysis. Finally, a directional sense presentation was conducted for users performing micromanipulations in a mixed-reality space to demonstrate the applicability of the proposed system for teleoperation.

0.73

Contact-Constrained Lower-Limb Joint-Offset Calibration for Humanoid Robots

cs.RO ·2026-09-02 ·Kaixiang Lu, Haiyu Lan, Chunxiao Qiao, You Li, Chengyuan Luo +3 more
top venue similarity 0.52
Abstract

Accurate joint encoder offsets are essential for kinematic consistency in humanoid lower limbs, yet existing calibration methods typically require external motion-capture systems or fiducial targets. We present a self-contained calibration framework exploiting only onboard joint encoders and a pelvis-mounted IMU during static double-support contact. The inter-foot transform from forward kinematics must stay constant when both feet are fixed; minimizing its posture-dependent dispersion yields a nonlinear least-squares problem over the 12-dimensional offset vector. A Hessian eigenstructure analysis shows that parallel pitch axes induce a rotational coupling. Orientation residuals then observe only the pitch-offset sum, while translation and posture diversity set the remaining numerical observability. For the A3 pitch-to-roll-to-yaw ordering, hip-roll and hip-yaw excitation reduce hip-pitch coupling. A standing-posture knee prior then anchors the remaining weak pitch-chain decomposition. Simulation and real-machine injection tests show consistent recovery, and on held-out recordings calibration reduces foot-height RMS residuals from 4.26 to 2.20 mm on A3 and from 8.03 to 1.43 mm on A2. An independent LiDAR-inertial reference checks the pitch-coupled channel. Removing an injected pitch offset moves the leg-odometry vertical drift back toward the LiDAR trajectory. A few static double-support stances thus provide contact-consistent corrections for well-excited directions. Individual offsets in the weak pitch chain remain prior-dependent.

0.44