CS Paper Radar

Spatiotemporal Distillation via Recurrent Bottlenecks for Aortic Tracking

Dexter Wen Jie Teo, Nairouz Shehata, Herve Lombaert

eess.IV cs.CVcs.LG ·submitted 2026-08-24 22:37 UTC · v1
published

Abstract

Cardiac cine-MRI serves as a direct visual indicator of cardiovascular hemodynamics by capturing the continuous wall motion of the aorta. Quantifying these dynamic structural changes across the cardiac cycle is essential for measuring aortic distensibility, a primary marker of arterial stiffness. However, standard 2D segmentation networks focus on each frame independently. Consequently, when rapid systolic flow temporarily obscures the aorta's boundaries, this lack of continuous context results in frame-to-frame tracking dropouts and boundary inconsistencies. Spatiotemporal ($2\text{D}+t$) networks can enforce temporal consistency across the sequence but suffer from a scarcity of expert annotations. To address this, we present a semi-supervised spatiotemporal ($2\text{D}$ to $2\text{D}+t$) knowledge distillation framework exploiting the cardiac cycle. The framework distills a spatial teacher's expertise into a spatiotemporal student network by executing a dynamic latent interception, pairing a recurrent spatiotemporal bottleneck with a residual spatial bypass. Our model selection strategy applies a baseline validation threshold ($\text{DSC} \ge 0.50$) prior to selecting the epoch that maximizes anatomical consistency. This strategy enables the spatiotemporal student model to achieve superior surface tracking accuracy ($\text{NSD@1mm} = 92.3\% \pm 0.2\%$) and high structural reliability ($\text{Frac}_{2\text{CC}} = 99.2\% \pm 0.6\%$), reducing population-wide structural anomalies by over 56\% compared to a 2D nnU-Net baseline.

Comment
Accepted at the 17th Statistical Atlases and Computational Models of the Heart (STACOM) Workshop, MICCAI 2026. Springer LNCS

Closest papers

Nearest neighbours by meaning across the whole index.

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.65
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

EchoDiST: Self-distillation-based joint learning for diffusion-conditioned echocardiographic myocardial motion estimation

cs.CV ·2026-10-08 ·Feiyue Qi, Xingyue Wei, Jianwen Luo
similarity 0.65
Abstract · 19 pages, 14 figures

Motion estimation in echocardiography is essential for quantitative assessment of cardiac function and myocardial mechanics, but remains challenging due to image artifacts, limited image information, speckle decorrelation, and the scarcity of ground-truth displacement fields. Anatomy-guided approaches can provide structural information, yet often rely on expert-labeled myocardial segmentations. We propose EchoDiST, a framework for unsupervised echocardiographic myocardial motion estimation that integrates self-distillation-based joint learning with a diffusion-conditioned motion estimation network. Here, unsupervised motion estimation refers to learning without ground-truth displacement fields. The self-distillation strategy jointly optimizes anatomical segmentation and myocardial motion estimation under limited anatomical annotations. Diffusion-based conditioning is used during training with stochastic perturbations, while inference requires only a single deterministic forward pass without iterative reverse-diffusion sampling. EchoDiST was evaluated on three echocardiographic datasets, including two external test datasets under cross-view and cross-dataset settings. Compared with seven representative learning-based methods, EchoDiST consistently improved anatomical alignment, myocardial strain assessment, and motion-derived functional and cardiac-phase assessment. These gains were statistically significant across the evaluated tasks and datasets. Overall, EchoDiST provides an effective approach for reliable myocardial motion estimation under limited anatomical supervision and supports downstream quantitative assessment of cardiac function.

0.21

Scribble Once, Segment the Sequence: Bidirectional Temporal Consistency for Weakly Supervised Segmentation in Echocardiography Sequences

eess.IV cs.CV ·2026-11-16 ·Vincent Li Weixin, Chen Jingkun, Vicente Grau
similarity 0.64
Abstract

Temporal medical image segmentation relies on pixel-wise annotations, which are prohibitively expensive for long image sequences. Existing weakly-supervised methods reduce the annotation burden per frame but still require repeated annotations across the sequence. Furthermore, sparse supervision can result in temporally unstable representations. Addressing both challenges requires a model that can leverage strong spatial priors from large-scale pretraining while minimizing reliance on dense annotations. Frozen 2D vision foundation models provide a promising basis for this by offering transferable spatial representations with low trainable parameters. However, their lack of explicit temporal modeling limits their ability to propagate reliable information across anatomical sequences. To address this, we present a weakly-supervised framework for temporal segmentation from a single scribble-annotated frame, with all remaining frames left unlabeled. The framework combines parameter-efficient adaptation of DINOv3 encoders present in the mean-teacher architecture. Furthermore, a set of complementary losses, including a temporal loss helps generate reliable segmentation priors for the unlabeled frames. This formulation decouples annotation costs from sequence length while retaining the transferable spatial knowledge of the pretrained encoder. Extensive experiments on the publicly available CAMUS and CardiacNet datasets demonstrate that our approach outperforms other scribble-supervised methods. These results show that accurate and temporally consistent segmentation can be achieved from extremely sparse supervision, substantially reducing annotation requirements for temporal echocardiographic segmentation and providing a practical framework for scalable clinical deployment.

0.16

Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations

cs.CV ·2026-09-03 ·Hinrich Rahlfs, Julio Garcia, Chiara Manini, Markus Hüllebrand, Sebastian Schmitter +11 more
code/data similarity 0.62
Abstract · Submitted to Journal of Cardiovascular Magnetic Resonance

Automated aortic segmentation in 4D flow MRI is essential for reproducible hemodynamic assessment but is limited by scarce dense annotations and high computational demands. We developed a fully automated 4D (3D+time) U-Net for segmenting the ascending aorta, arch, and proximal descending aorta, using a parameter-efficient hybrid 4D kernel to capture temporal context and sparse 4D labels derived from existing 2D expert contours and centerlines, thereby avoiding the need for dense 4D annotations. Training comprised 268 scans from 8 centers and 2 vendors, with evaluation on an internal test set (32 scans) and an external post-contrast set (30 scans; different site, protocol, and annotator), compared against frame-wise 3D networks and two semi-automatic references. Against time-resolved annotations, the 4D U-Net achieved Dice scores of 0.927 (internal) and 0.911 (external), versus 0.919/0.847 for the 3D U-Net, 0.893 for static PC-MRA, and 0.808 for registration-based propagation; differences were small in systole but pronounced in diastole. Agreement with expert contours for peak velocity, net flow, axial and circumferential wall shear stress, and diameters was excellent (ICC >=0.954 internal, >=0.980 external), while semi-automatic references performed worse. The method thus provides reproducible, time-resolved aortic segmentation for automated hemodynamic analysis and generalizes across multicenter, multivendor, and independent post-contrast data. The model is publicly available.

0.45

One Frame, Full Heartbeat: ECG-Free 4D Cardiac Cine MRI Synthesis via Radial-Decomposed Flow Matching

cs.CV ·2026-10-06 ·Shiyi Wang, Ruochen Sun, Xiang Li, Peirong Liu, Fangxu Xing
benchmark similarity 0.61
Abstract

Cine cardiovascular magnetic resonance (CMR) captures the cardiac cycle as a four-dimensional (4D) sequence, but standard acquisition requires electrocardiogram (ECG) gating and repeated breath holds. Visual realism alone does not establish accurate patient-specific ejection fraction (EF) or ventricular volumes. We present PhaseFlow3D, a generative framework that synthesizes a complete 4D cine sequence from a single end-diastolic (ED) three-dimensional (3D) volume without ECG. To capture asymmetric systolic and diastolic dynamics, it represents the cardiac cycle as a piecewise linear phase anchored at ED and end-systolic (ES) time points. At inference, a population-level canonical template supplies this phase without patient-specific temporal information. A phase-conditioned rectified flow model generates a cardiac motion trajectory in latent space. Radial Contraction Decomposition converts each latent state into a 3D displacement field, combining a physics-informed radial component for centripetal myocardial contraction with an image-conditioned residual for rotation and out-of-plane motion. Each frame is generated by directly warping the ED volume, bypassing variational autoencoder decoding. On the combined ACDC and M&Ms benchmark, PhaseFlow3D achieves the lowest EF mean absolute error, the only positive left-ventricular volume-curve $R^2$, and the best distributional quality among compared methods. Ablations confirm each component's contribution. Downstream evaluations demonstrate the utility of the synthesized sequences and displacement fields for segmentation, pathology classification, label propagation, and myocardial strain analysis.

0.23

CardioTrace: Motion-Aware Cine Synthesis via Coupled Tracing and Segmentation

cs.CV ·2026-11-13 ·Zhi Chen, Le Zhang
hot direction similarity 0.60
Abstract

Cardiac cine MRI provides time-resolved visualization of cardiac motion and is essential for evaluating ventricular function and anatomy. In routine clinical acquisition, however, cine sequences are frequently temporally sparse or degraded by arrhythmia, motion, and scan-time constraints, which can hinder reliable quantification and downstream analysis. We present CardioTrace, a motion-aware cine synthesis framework that generates a full cardiac cine sequence from limited input while explicitly modeling and tracing cardiac motion. CardioTrace couples two complementary pathways: a pixel-translation branch that directly predicts cine frames in a residual formulation, and a flow-field branch that estimates time-resolved deformation fields from a reference phase to provide interpretable motion correspondences across frames. To further preserve anatomical plausibility, a segmentation branch supervises clinically meaningful cardiac structures at key phases, and a cross-branch consistency objective encourages the synthesized appearance dynamics to follow the explicit motion guidance, mitigating temporal drift and unrealistic shape transitions over long sequences. The framework also supports prompt-style conditioning to incorporate auxiliary patient or acquisition information, improving robustness across heterogeneous multi-center data. Experiments on public cardiac cine MRI datasets demonstrate that CardioTrace improves perceptual quality and temporal coherence over representative GAN- and diffusion-based baselines, while better preserving ventricular morphology throughout the cardiac cycle. \textit{Our codes are available after review}.

0.17

CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

cs.CV physics.med-ph ·2026-11-10 ·Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
similarity 0.60
Abstract · Under review

Objective: To improve the spatial and temporal resolution of aortic 4D flow MRI through a unified deep learning framework for post-acquisition super-resolution (SR) of reconstructed velocity vector fields. Methods: We propose CURRENT, a recurrent neural network that performs spatial and temporal SR with a single network architecture. Supervised training was conducted using paired low- and high-resolution datasets generated by embedding computational fluid dynamics simulations of aortic flow into in vivo thoracic MRI backgrounds, followed by controlled spatial and temporal downsampling. CURRENT was evaluated for two-fold spatial and temporal SR against 4DFlowNet and for two-fold spatiotemporal SR against sequential spatial and temporal SR pipelines based on 4DFlowNet. Image-based and k-space-based quantitative metrics were considered and conventional interpolation were used as baselines. In addition, the impact of CURRENT's spatiotemporal SR on physics-informed relative pressure estimation was assessed. Finally, the ability of CURRENT to generalize from synthetic training data to in vivo acquisitions was investigated. Results: CURRENT achieved superior spatial SR performance and comparable temporal SR performance to dedicated 4DFlowNet models while providing a unified solution for both tasks. Simultaneous spatiotemporal SR using CURRENT yielded more accurate relative pressure estimates than either spatial or temporal SR alone and outperformed sequential 4DFlowNet-based spatial and temporal SR approaches. Furthermore, the proposed model demonstrated promising generalization to in vivo 4D flow MRI data despite being trained exclusively on synthetic datasets. Conclusion: CURRENT provides a unified framework for spatial and temporal SR of 4D flow MRI. The proposed approach has the potential to enhance physics-based analysis and broaden the applicability of accelerated 4D flow MRI.

0.17

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

eess.IV cs.AIcs.CV ·2026-09-09 ·Thierry Judge, Nicolas Duchateau, Andreas Østvik, Havard Dalen, Bjørnar Grenne +4 more
similarity 0.60
Abstract · STACOM 2026, 10 pages

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

0.37