CS Paper Radar

Coverage Planning for Robotic Tooth Preparation in Densely Constrained Environments

Yunwen Li, Chen Chen, Xiangjie Yan, Chang Shu, Jianxia Hou, Shiji Song, Xiang Li

cs.RO ·submitted 2026-08-25 07:16 UTC · v1

Abstract

Tooth preparation refers to the controlled removal of tooth structure to create an optimal substrate for fixed restorations and is a core procedure in restorative dentistry. Automating this task is particularly challenging for robots because the dental bur must operate within a densely constrained intraoral workspace, where even sub-millimeter deviations can compromise outcomes or damage adjacent structures. This paper presents a novel robotic system for autonomous full-crown tooth preparation. The proposed framework includes: 1) an anatomy-aware toolpath planning algorithm that conforms precisely to a technician-designed preparation model while protecting adjacent teeth, and 2) a clearance-oriented end-effector yaw assignment strategy that allows intraoral access while reducing the risk of soft-tissue interference. Together, these features enable the robot to accurately mill the irregular tooth surface with an average geometric deviation of 0.117 mm (RMSE), achieving both restoration quality and clinical safety. A series of simulations and phantom-head experiments validate the system's feasibility and effectiveness.

Closest papers

Nearest neighbours by meaning across the whole index.

Autonomous Precision Milling of Biological Structures via Generic Anatomical Priors and Active Boundary Perception

cs.RO eess.SY ·2026-09-11 ·Enduo Zhao, Xiaofeng Lin, Yifan Wang, Yuhan Song, Weihan Li +2 more
similarity 0.51
Abstract · ver 2. 18 pages, 12 figures. Submitted to IEEE Transactions on Automation Science and Engineering (T-ASE) for possible publication

Autonomous precision milling of biological structures is challenged by incomplete knowledge of target geometry, local material thickness, and critical internal boundaries. Subject-specific preoperative models can address geometric and thickness variations, but static models cannot determine boundary status encountered during execution, while repeated target-specific imaging limits scalability. This article presents a state-adaptive autonomous milling framework that assigns complementary roles to generic anatomical priors and active boundary perception. A generic anatomical prior provides conservative global guidance and is transformed through semantic-guided registration and hybrid vision-force calibration into robot-executable guidance for individual targets. As milling approaches uncertain boundaries, the robot actively probes the remaining structure and uses relative stiffness changes to estimate boundary status and structural detachability. A state-adaptive controller governs transitions between active perception and spatially selective incremental refinement, repeating this cycle until the termination criterion is satisfied. Hierarchical experiments on biological surrogates and in vivo mouse cranial window creation demonstrate accurate anatomical prior transfer, reliable boundary adaptation, and autonomous precision milling of biological structures.

0.29

Anatomy-Aware Dexterity-Driven Design Optimization of Surgical Continuum Robots

cs.RO cs.AI ·2026-09-25 ·Tony Qin, Peter Connor, Khoa Dang, Carter Hatch, Caleb Rucker +2 more
similarity 0.49
Abstract

Performing complex medical procedures with continuum robots requires careful selection of their geometric design parameters. The robot should have high dexterity in the specific anatomical environment of its procedure. This work presents a design optimization method that considers both dexterity and anatomy. We introduce the Reachable Volumetric Dexterous Solid Angle (RVDSA) metric as our objective, which measures the ability of a robot's end effector to reach the points in a goal volume from different directions via collision-free paths from a start configuration. We present a computationally efficient motion planner to compute this objective function for a given robotic design, and we use an asymptotically optimal simulated annealing optimizer to compute an optimized design. We applied our new method to optimize the design of a bimanual dexterous sheaths robot for performing procedures on cancerous polyps in colon anatomies, achieving a 78% higher RVDSA on average than optimizing for 3D voxel coverage alone.

0.31

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.49
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30

Towards Vacuum-Assisted Robotic Needle Interventions: From Fluid Aspiration to Tissue Biopsy

cs.RO ·2026-11-18 ·Sheena Shabana, Laxmi Nag Laxminarayan Nagesh, Marta Vallejo, Karen Donaldson, Maria Koskinopoulou
similarity 0.48
Abstract · 8 pages, 8 figures, Submitted to the 2027 IEEE International Conference on Robotics and Automation (ICRA)

Robotic ultrasound-guided needle interventions have primarily focused on target localization and accurate needle placement, while the subsequent acquisition of diagnostic material remains comparatively underexplored. Moreover, pleural fluid aspiration and tissue biopsy are typically addressed as separate procedures, despite sharing common requirements for ultrasound guidance, safe access, and sample transport. This work presents a unified robotic framework for ultrasound-guided fluid and tissue extraction using a single vacuum-assisted end effector. The proposed system combines force controlled ultrasound scanning, semantic target identification, automated needle deployment, and procedure specific material acquisition. A coaxial needle assembly and shared pump assisted pathway enable direct pleural fluid aspiration, while controlled cannula actuation provides the additional cutting action required for solid-tissue acquisition. End-to-end evaluation using a Franka Emika Panda robot over 50 phantom trials achieved successful extraction in 23/25 pleural fluid aspiration trials (92\%) and 22/25 tissue acquisition trials (88\%). Following successful tissue-target access, acquisition and transport were completed in all 22 trials.

0.32

Contact-Stable Deformable Tissue Simulation Using Implicit Integration and Live-Pose Grasp Constraints for Laparoscopic Surgery Robot Policy Evaluation

cs.RO ·2026-09-22 ·Juahn Oh, Dongho Yee, Jinseok Lee, Jiyul Lee, Yechan Seo +7 more
hot direction similarity 0.47
Abstract · Submitted to IEEE ICRA 2027

Closed-loop evaluation of surgical robots requires tissue that deforms, can be grasped and lifted, and reproduces the anatomy in which the robot will operate. We present a simulator in which this tissue is reconstructed from a fixed-view RGB-D recording of the surgical field, composited to remove the instruments, closed into watertight volumes and tetrahedralised; the pipeline was applied unchanged to three specimens of two species (thirteen organs, 146,061 tetrahedra, no inverted elements). For one specimen, the organs are placed in a bimanual cell in which two Franka FR3 arms operate motorised instruments through 6 mm trocars. The core contribution is the numerical and contact design that keeps this cell stable: implicit integration, simulation meshes separate from collision meshes, numerical guards, and a grasp constraint captured at the live tissue pose. In 45 repeated grasp-lifts, a friction grasp held the tissue in 0 of 15 trials and each constraint grasp in 13 of 15; on displaced tissue, a rest-pose constraint produced one-step snaps of up to 17.8 mm, which live-pose capture eliminates. Against the recording, front-surface depth error is 1.33 to 1.41 mm, organ silhouette IoU is 0.80, and in five grasp-lifts reproduced from video the landmark displacement RMSE is 11.8 mm against 14.2 mm for a static prediction. Biofidelity is not claimed; the environment is intended for closed-loop feasibility, safety, contact and policy screening.

0.32

Detection is solved, delineation is not: what governs tooth segmentation on panoramic radiographs

cs.CV cs.LG ·2026-09-18 ·Muhammad Rehan, Moaz Amjad, Syed Danial Ahmed, Mariam Adnan, Haider Ali
code/data similarity 0.47
Abstract · 15 pages, 6 figures, 5 tables. Code: https://github.com/Rehan000/opg-tooth-segmentation

Automatic tooth segmentation and FDI numbering on panoramic radiographs underpins computer-assisted dental diagnosis, yet which factors govern performance remains unclear. We assemble a corpus of 1,422 panoramic radiographs containing 42,142 expert-delineated tooth polygons across the 32-class FDI taxonomy, annotated by 30 dental practitioners and independently reviewed by two others, and use it to isolate input resolution, architecture and anatomical priors under a single evaluation protocol. First, resolution dominates: across a controlled 640/1024/1280 ablation, mask mAP50-95 rises 0.656 -> 0.710 -> 0.717 while mAP50 stays flat at ~0.982. Both gains are significant under a paired bootstrap over images (p < 0.001, p = 0.024); neither mAP50 change is distinguishable from zero. Added resolution buys boundary precision, not detection. Second, architecture is nearly irrelevant in-domain: a query-based transformer with 2.1x the parameters is statistically equivalent to a one-stage detector (95% CI [-0.0064, +0.0064]), only marginally better under domain shift, 5.5x slower on CPU and not executable under standard ONNX runtimes. Third, three targeted interventions fail: a LoRA-adapted self-supervised encoder underperforms, a promptable foundation segmenter degrades masks by 39%, and globally optimal anatomical label assignment yields +0.0007 despite correcting a constraint violated in 40% of out-of-domain predictions. Zero-shot transfer to an independent multi-centre cohort, verified overlap-free, costs 62% of mask mAP50-95 but only 18% of mAP50, reproducing the dissociation. Decomposing masks along the tooth axis localises the residual error to the apical third. Boundary precision is therefore the binding constraint, and effort is better directed at resolution and acquisition diversity than at architectural novelty.

0.36

AgenTeeth: A Model-Agnostic Framework for Suppressing Hallucination in Frozen Vision-Language Models on Dental X-Rays via Tool Evidence Injection

cs.CV ·2026-09-15 ·Ahmed Rafid, Fariya Ahmed, Rumman Adib, Mehedi Ahamed, Ajwad Abrar +1 more
similarity 0.47
Abstract · 10 pages, 2 figures, 5 tables

Vision-language models (VLMs) remain largely unreliable on panoramic dental radiographs and can rely on learned anatomical priors rather than evidence in the image. This is particularly problematic for tooth localization and spatial reasoning, and fine-tuned dental VLMs can retain the same spatial biases. We present AgenTeeth, a model-agnostic, tool-augmented framework that grounds frozen VLMs using seven specialized dental vision experts. A question-aware orchestrator selects the relevant tools, whose detections are mapped to FDI tooth numbers or anatomical regions and returned as structured findings together with annotated image overlays. A fresh synthesis call then answers the question using this evidence, without fine-tuning the underlying VLM. On MMOral-OPG-Bench, AgenTeeth improves four backbone VLMs by 12.9-23.0 percentage points over their baselines. Our strongest configuration reaches 65.66% on open-ended VQA, compared with 45.35% for OralGPT-Plus. The advantage also holds at matched scale: a frozen Qwen2.5-VL-7B-Instruct with AgenTeeth reaches 48.11%, exceeding OralGPT-Plus built on the same backbone after supervised fine-tuning and reinforcement learning for tool use. We release the framework, all seven expert models, and a dentist-annotated dataset for alveolar bone-loss detection in panoramic radiographs.

0.13

Supervised Autonomous Bimanual Suction and Cauterization for Bleeding Control in Low Grade Splenic Trauma

cs.RO ·2026-10-30 ·Francis Fan, Mackenzie A Eagleson, Yvonne Zhang, Hongting Pan, Lujia Yang +8 more
similarity 0.46
Abstract

Uncontrolled hemorrhage remains a leading cause of preventable trauma mortality. Timely intervention is not always available, making autonomous systems that can aid in bleeding control a promising alternative. Given the safety-critical nature of the task, supervised autonomy, in which the system executes the technical steps while a human retains oversight, represents a necessary intermediate step toward this goal. In this work, we present a supervised autonomous bimanual robotic framework for injury cauterization (eletrosurgical coagulation) in low-grade splenic trauma. The system integrates real-time bleeding segmentation, markerless tool keypoint tracking, and deep tool-tissue contact detection to coordinate two robotic arms for synchronized suction and cauterization. Evaluated on a novel, cannulated ex vivo splenic hemorrhage model, the system achieved an average bleeding surface cauterization coverage of 82.9% across seven distinct injuries. This work demonstrates the feasibility of using a supervised autonomous bimanual system to deliver targeted coagulation across an injury site.

0.51