CS Paper Radar

Towards Vacuum-Assisted Robotic Needle Interventions: From Fluid Aspiration to Tissue Biopsy

Sheena Shabana, Laxmi Nag Laxminarayan Nagesh, Marta Vallejo, Karen Donaldson, Maria Koskinopoulou

cs.RO ·submitted 2026-11-18 11:40 UTC · v1

Abstract

Robotic ultrasound-guided needle interventions have primarily focused on target localization and accurate needle placement, while the subsequent acquisition of diagnostic material remains comparatively underexplored. Moreover, pleural fluid aspiration and tissue biopsy are typically addressed as separate procedures, despite sharing common requirements for ultrasound guidance, safe access, and sample transport. This work presents a unified robotic framework for ultrasound-guided fluid and tissue extraction using a single vacuum-assisted end effector. The proposed system combines force controlled ultrasound scanning, semantic target identification, automated needle deployment, and procedure specific material acquisition. A coaxial needle assembly and shared pump assisted pathway enable direct pleural fluid aspiration, while controlled cannula actuation provides the additional cutting action required for solid-tissue acquisition. End-to-end evaluation using a Franka Emika Panda robot over 50 phantom trials achieved successful extraction in 23/25 pleural fluid aspiration trials (92\%) and 22/25 tissue acquisition trials (88\%). Following successful tissue-target access, acquisition and transport were completed in all 22 trials.

Comment
8 pages, 8 figures, Submitted to the 2027 IEEE International Conference on Robotics and Automation (ICRA)

Closest papers

Nearest neighbours by meaning across the whole index.

Integrated Respiratory Sensing and Gated Control for Autonomous Needle Insertion Via CT Bore Robotic Arm

cs.RO ·2026-10-21 ·Emma Huang, Moira Bohley, Krishna Jamakhandi, Rebecca Fellbaum, Sophia Tang +8 more
unusual similarity 0.58
Abstract

Currently, CT-guided lung biopsy is a highly manual procedure requiring patient breath-holding, iterative manual needle insertions, and repeated CT confirmation scans to accurately target a tumor. Automating this process within the CT bore--without relying on manual needle placement or patient breath-holding--has the potential to reduce procedure time, patient discomfort, and radiation exposure. In this work, we present an integrated sensing and control system capable of performing a gated needle insertion within the CT bore. The experiments demonstrate the system's ability to track and predict patient breath cycles, perform autonomous respiratory-gated needle insertion, and detect breath cycle anomalies.

0.24

A Master-to-Simulation Interface with Demonstration-Trajectory Guidance for Vascular Intervention

cs.RO ·2026-10-14 ·Mingyu Zou, Shuxiang Guo, Sheng Cao, Pengcheng Li, Jian Guo +2 more
similarity 0.54
Abstract · 6 pages, 3 figures, submitted to IEEE journals

Robotic vascular intervention can reduce radiation exposure to physicians and improve manipulation stability, but effective guidance remains challenging because conventional fluoroscopic images provide limited spatial information. This paper developed a vascular intervention interactive system that connects a real robotic master controller with the SOFA(Simulation Open Framework Architecture) physical simulation platform and reused successful operation trajectories as visual guidance in physical phantom experiments. Experiments were conducted to validate the master-to-SOFA control loop and to compare three guidance conditions: no guidance, centerline guidance, and successful-trajectory guidance. The control validation results showed reliable command delivery under velocity-mode operation. In the physical phantom experiment, centerline guidance showed no obvious improvement over no guidance. In contrast, successful trajectory guidance provided a clear performance benefit. Compared with the no-guidance condition, it reduced task completion time, collision number, rollback number, and rotation number by approximately 66.8%, 34.3%, 55.6%, and 66.7%, respectively. These results indicate that successful trajectories obtained under instrument-vessel interaction can provide practical guidance cues, offering a simple and effective visual assistance strategy for robotic vascular intervention experiments.

0.32

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.54
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30

Physically Constrained Kinematic Calibration for High-Precision Robotic Needle Guidance

cs.RO eess.SYmath.OC ·2026-10-30 ·Prabhu Nithin Gollapudi, Andreas Maier, Franziska Mathis-Ullrich, Water Zhao, Jia Wang +1 more
similarity 0.54
Abstract · 6 pages, 4 figures, 4 tables

Percutaneous needle insertion is a common practice in minimally invasive procedures whose clinical success depends on accurate needle placement. However, achieving the necessary precision is a challenge for manual operators. Robotic assistance can improve targeting accuracy and reduce operator dependence, but residual millimeter-scale errors persist because nominal kinematic models do not fully represent the physical manipulator. This paper presents a robust bound-constrained kinematic calibration method designed to improve positional accuracy for a 6-Degree-of-Freedom (6-DoF) robotic needle-guidance manipulator. The approach uses physically plausible parameter ranges to regularize a compact 19-parameter geometric identification model. By treating these bounds as active optimization constraints rather than mere numerical safeguards, the framework effectively mitigates parameter coupling and overfitting, ensuring highly stable parameter identification. In simulation, the proposed method reduced end-effector Root Mean Square Error (RMSE) from 3.422 mm to 0.690 mm (a 79.8% improvement). In benchtop hardware experiments, the calibrated model achieved sub-millimeter validation accuracy, including 0.865 mm RMSE in experimental trajectory validation and 0.610 mm RMSE in a coordinate-lattice verification task. These results demonstrate that physically constrained kinematic calibration can enhance robotic needle-targeting accuracy, establishing a high-precision foundation for future clinical applications.

0.38

Supervised Autonomous Bimanual Suction and Cauterization for Bleeding Control in Low Grade Splenic Trauma

cs.RO ·2026-10-30 ·Francis Fan, Mackenzie A Eagleson, Yvonne Zhang, Hongting Pan, Lujia Yang +8 more
similarity 0.53
Abstract

Uncontrolled hemorrhage remains a leading cause of preventable trauma mortality. Timely intervention is not always available, making autonomous systems that can aid in bleeding control a promising alternative. Given the safety-critical nature of the task, supervised autonomy, in which the system executes the technical steps while a human retains oversight, represents a necessary intermediate step toward this goal. In this work, we present a supervised autonomous bimanual robotic framework for injury cauterization (eletrosurgical coagulation) in low-grade splenic trauma. The system integrates real-time bleeding segmentation, markerless tool keypoint tracking, and deep tool-tissue contact detection to coordinate two robotic arms for synchronized suction and cauterization. Evaluated on a novel, cannulated ex vivo splenic hemorrhage model, the system achieved an average bleeding surface cauterization coverage of 82.9% across seven distinct injuries. This work demonstrates the feasibility of using a supervised autonomous bimanual system to deliver targeted coagulation across an injury site.

0.51

Interactive 3D Cutaway Visualization for Subsurface Target Localization in Robot-Assisted Surgery

cs.RO ·2026-11-02 ·Yuxin Chen, Wenxuan Wang, Wanwen Chen, Qi Zeng, Septimiu E. Salcudean
similarity 0.52
Abstract

Purpose: Blended augmented reality (AR) overlays can provide ambiguous depth cues in which subsurface anatomy floats above the tissue surface. We investigate whether an interactive 3D cutaway visualization can improve robot-assisted target localization. Methods: We propose Virtual Box, an interactive 3D cutaway interface that allows users to independently manipulate the viewing perspective to inspect subsurface targets. In a controlled, counterbalanced within-subject tissue phantom study, 15 engineering students used Virtual Box and a depth-enhanced blended AR overlay to position a da Vinci instrument at virtual targets in a water tank. We used registered 3D transrectal ultrasound to measure 3D localization error and depth error. We also collected completion time and subjective ratings. Results: Virtual Box reduced mean 3D error from 12.92 to 4.96 mm (61.6% reduction) and depth error from 9.48 to 2.07 mm (78.2% reduction; both p < 0.001). Spatial understanding, depth perception, and confidence ratings were higher (all unadjusted p < 0.001), but completion time increased from 21.64 to 32.58 s (p = 0.008). Overall workload did not differ significantly. Conclusion: Virtual Box improved localization accuracy and perceived spatial understanding in this controlled task, with additional completion time, supporting further evaluation for surgical navigation.

0.28

Simulating Vein Compressibility for Ultrasound-Guided Femoral Access: Speed, Accuracy, and Phantom Validation

cs.RO ·2026-11-09 ·Amit Manicka, Laurent Coulon, Darwin Ang, Michael Loushin, Timothy M. Kowalewski
similarity 0.52
Abstract · Submitted to the Journal of Medical Robotics Research (JMRR) for the International Symposium of Medical Robotics 2027 (ISMR 2027) 11 Pages (…

In ultrasound-guided femoral access, probe pressure deforms the tissue and changes the vascular anatomy a robot observes. A simulator must reproduce these mechanics fast enough for robotic interaction, yet the computational effort needed for a clinically meaningful signal like vein collapse before artery is unclear. We test the feasibility of a physics-based simulation in NVIDIA's Isaac Sim for Healthcare, with Stable Neo-Hookean tissue solved by Vertex Block Descent on one GPU. A simulation of a low-fidelity cylindrical benchtop phantom with known geometry and mechanical properties, pressed by a robot, predicted its artery within 5 percentage points at every depth. It matched the vein within 3 points through 11 mm of a 25.4 mm press and followed the collapse behavior of the low-fidelity physical phantom. Across element size, time step, and solver iterations, wall clock time per frame scaled linearly with solver work, but accuracy did not improve with more work. The chosen setting reduced solver time per frame by a factor of 976, from 29,700 ms to 30.4 ms, while remaining within 1.03 points of the finest reference setting. The physics solver alone took 30.4 ms per frame, while the full stack, including ultrasound and graphics rendering, took 56.4 ms per frame. Finally, when seeded with realistic literature-based mechanical properties, the digital leg model compressed the vein far more than the artery at every setting, reproducing the expected clinical signal of vein collapse before artery, which is used to distinguish them. In total, these results suggest that the NVIDIA Isaac Sim platform may be suitable for augmenting reinforcement learning training or online simulation for autonomous femoral access with ultrasound.

0.22

Helping Hand: A Continuum Robotic Grasper for Traction in Single-Channel Endoscopic Submucosal Dissection

cs.RO ·2026-11-11 ·Bendavid Maimon, Thompson Wong, Aedan Mangan, Sukjun Kim, Michael C. Yip +1 more
similarity 0.51
Abstract · 7 pages, 9 figures

Endoscopic submucosal dissection (ESD) is a minimally invasive approach for removing large polyps from the colon and offers many benefits compared to other surgical approaches. However, ESD is technically very challenging to perform, leading to limited adoption by physicians. We propose the Helping Hand, a two-segment continuum robotic grasper that, together with an electrosurgical knife, enables tissue traction and cutting within a single 3.7 mm working channel. We achieve this functionality by creating a slot at the base of the Helping Hand that lets the electrosurgical knife extend out, enabling countertraction and cutting through one instrument lumen. We evaluate the Helping Hand's workspace and its ability to provide traction forces from different starting configurations. Finally, we demonstrate the full workflow by isolating and removing tissue in an ex vivo chicken thigh, illustrating the potential for the Helping Hand to help improve ESD procedures.

0.22