CS Paper Radar

Helping Hand: A Continuum Robotic Grasper for Traction in Single-Channel Endoscopic Submucosal Dissection

Bendavid Maimon, Thompson Wong, Aedan Mangan, Sukjun Kim, Michael C. Yip, Tania K. Morimoto

cs.RO ·submitted 2026-11-11 15:51 UTC · v1

Abstract

Endoscopic submucosal dissection (ESD) is a minimally invasive approach for removing large polyps from the colon and offers many benefits compared to other surgical approaches. However, ESD is technically very challenging to perform, leading to limited adoption by physicians. We propose the Helping Hand, a two-segment continuum robotic grasper that, together with an electrosurgical knife, enables tissue traction and cutting within a single 3.7 mm working channel. We achieve this functionality by creating a slot at the base of the Helping Hand that lets the electrosurgical knife extend out, enabling countertraction and cutting through one instrument lumen. We evaluate the Helping Hand's workspace and its ability to provide traction forces from different starting configurations. Finally, we demonstrate the full workflow by isolating and removing tissue in an ex vivo chicken thigh, illustrating the potential for the Helping Hand to help improve ESD procedures.

Comment
7 pages, 9 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Selectively Actuated Fiberbots for High-precision Minimally Invasive Surgery

cs.RO ·2026-10-08 ·Jinshi Zhao, Libaihe Tian, Alex Ranne, Qindong Zheng, Yue Li +7 more
similarity 0.63
Abstract · 7 pages, 7 figures

Long, slender instruments are essential for minimally invasive surgery (MIS), but achieving precise distal manipulation becomes increasingly difficult when actuation extends along the entire instrument. Here, we present an electrothermally actuated fiber-based robot designed for MIS procedures, in which Joule heating is concentrated in the distal active segment. The fiber is fabricated using a thermal drawing process and uses embedded metallic wires for thermal actuation. This robotic fiber, 1.9 mm in diameter and 1.2 m in length, can precisely manipulate surgical laser fibers with positional precision below 100 $μ$m. The compact size of the fiber robot allows it to pass through the working channel of a flexible endoscope, while keeping both devices mechanically uncoupled to allow independent motion. A phantom demonstration combining the robotic fiber with a da Vinci instrument conceptually demonstrated its compatibility with existing endoscopic systems for clinical applications. Our robotic fiber enables precise distal motion and holds the potential to improve clinical outcomes by enhancing precision in MIS procedures.

0.33

Contact-Stable Deformable Tissue Simulation Using Implicit Integration and Live-Pose Grasp Constraints for Laparoscopic Surgery Robot Policy Evaluation

cs.RO ·2026-09-22 ·Juahn Oh, Dongho Yee, Jinseok Lee, Jiyul Lee, Yechan Seo +7 more
hot direction similarity 0.61
Abstract · Submitted to IEEE ICRA 2027

Closed-loop evaluation of surgical robots requires tissue that deforms, can be grasped and lifted, and reproduces the anatomy in which the robot will operate. We present a simulator in which this tissue is reconstructed from a fixed-view RGB-D recording of the surgical field, composited to remove the instruments, closed into watertight volumes and tetrahedralised; the pipeline was applied unchanged to three specimens of two species (thirteen organs, 146,061 tetrahedra, no inverted elements). For one specimen, the organs are placed in a bimanual cell in which two Franka FR3 arms operate motorised instruments through 6 mm trocars. The core contribution is the numerical and contact design that keeps this cell stable: implicit integration, simulation meshes separate from collision meshes, numerical guards, and a grasp constraint captured at the live tissue pose. In 45 repeated grasp-lifts, a friction grasp held the tissue in 0 of 15 trials and each constraint grasp in 13 of 15; on displaced tissue, a rest-pose constraint produced one-step snaps of up to 17.8 mm, which live-pose capture eliminates. Against the recording, front-surface depth error is 1.33 to 1.41 mm, organ silhouette IoU is 0.80, and in five grasp-lifts reproduced from video the landmark displacement RMSE is 11.8 mm against 14.2 mm for a static prediction. Biofidelity is not claimed; the environment is intended for closed-loop feasibility, safety, contact and policy screening.

0.32

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.56
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30

Design and Modeling of a Single-Port Three-Arm Robotic Tool for Minimally Invasive Neurosurgery

cs.RO ·2026-09-22 ·Nazia H. Dana, Harith S. Gallage, Ismail A. Auta, Dhanvi Yuvaraj, Ronghuai Qi
similarity 0.54
Abstract · 6 pages, 11 figures, submitted to IEEE ROBIO 2026

Surgical robots require highly dexterous and compact robotic systems capable of operating effectively within confined anatomical spaces. However, due to limited access provided by a single incision, the miniaturization and maneuverability of these robots still need to be improved. In this paper, we propose the design and modeling of a single-port three-arm robotic tool containing one major cannula (7.14 mm outer diameter (OD)) and three steerable minor cannulas (1.93 mm OD). By integrating the proposed 12 degrees-of-freedom (DoFs) steerable robotic tool with a 7-DoF robotic arm, this robotic system can potentially achieve multi-arm manipulation capability. We present the design of the steerable robotic tool consisting of tendon-driven joints controlled by a compact actuation system, derive the kinematic model, and validate both the static and kinematic models through experiments. The performance is evaluated with the root mean square error (RMSE) and mean absolute error (MAE) computed between the experimental data and the kinematic model.

0.40

Anatomy-Aware Dexterity-Driven Design Optimization of Surgical Continuum Robots

cs.RO cs.AI ·2026-09-25 ·Tony Qin, Peter Connor, Khoa Dang, Carter Hatch, Caleb Rucker +2 more
similarity 0.54
Abstract

Performing complex medical procedures with continuum robots requires careful selection of their geometric design parameters. The robot should have high dexterity in the specific anatomical environment of its procedure. This work presents a design optimization method that considers both dexterity and anatomy. We introduce the Reachable Volumetric Dexterous Solid Angle (RVDSA) metric as our objective, which measures the ability of a robot's end effector to reach the points in a goal volume from different directions via collision-free paths from a start configuration. We present a computationally efficient motion planner to compute this objective function for a given robotic design, and we use an asymptotically optimal simulated annealing optimizer to compute an optimized design. We applied our new method to optimize the design of a bimanual dexterous sheaths robot for performing procedures on cancerous polyps in colon anatomies, achieving a 78% higher RVDSA on average than optimizing for 3D voxel coverage alone.

0.31

ColoACT: Multi-Cue Action Chunking for Smooth Autonomous Colon Navigation on a Self-Propelled Endoscopic Robot

cs.RO ·2026-10-01 ·Jian Hu, Shujing He, Leixin Chang, Zongze Li, Ding Huang +2 more
code/data similarity 0.54
Abstract

Autonomous colonoscopic navigation can reduce operator burden and the risk of loop formation or tissue trauma, but remains challenging due to deformable anatomy, weak-texture and specular endoscopic visuals, and contact-rich viscoelastic interactions. Existing methods either rely on geometry-driven pipelines, which are efficient and interpretable yet brittle due to manually engineered features and switching logic, or adopt learning-based policies, whose inferred depth/geometry can become temporally inconsistent or overly smooth under weak texture and specular highlights while simulation-trained variants (e.g., deep reinforcement learning) may further suffer from a sim-to-real gap. We propose ColoACT, an autonomous navigation system that integrates an RGB-D-E based Action Chunking Transformer policy (ColoACT policy) for a compact self-propelled Bevel-Gear-Based Endoscopic Robot (BGER). The ColoACT policy augments RGB with estimated relative depth and a gradient-based pseudo-elevation map to enhance fold-ridge saliency and other high-frequency geometric cues, and enables smooth continuous control of the BGER by predicting overlapping action chunks and fusing them via temporal ensembling. In different \textit{ex-vivo} porcine colons (approximately 60 cm), our system achieves success rates of 85.4\% and 72.5\% in straight and curved segments, respectively, and achieves 70\% success in 90-degree turns and 60\% in double-bend sequences, with feasibility further demonstrated in challenging triple-bend segments. The project page is available at: https://Adamhu1.github.io/ColoACT/.

0.24

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

cs.RO ·2026-09-27 ·Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh +7 more
similarity 0.54
Abstract · Submitted to IEEE ICRA 2027

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

0.32

The Cartesian Hand: In-Hand Manipulation with All-Linear Fingers

cs.RO ·2026-09-22 ·Boxi Xia, Bokuan Li, Ryan Shin, Zijiang Yang, Jiaxun Liu +1 more
code/datahot direction similarity 0.53
Abstract · 9 pages, 7 figures

Robotic manipulation has increasingly pursued human-like dexterous hands with many articulated degrees of freedom, offering rich manipulation capabilities at the cost of mechanical and control complexity. At the other extreme, parallel grippers are simple and robust, but provide little ability to manipulate an object after grasping it. Operating articulated objects such as threaded containers, manufacturing tools, and laboratory instruments often requires a second gripper, an external fixture, or coordinated arm motion. We introduce the Cartesian Hand, a 7-DoF end-effector that rethinks dexterous manipulation by combining independent grasping and relative manipulation within a single end-effector using only linear motion. Two independently actuated parallel grippers hold different parts of an object, while four translating fingertips generate relative motion between the grasped parts. Its configuration-independent fingertip kinematics allow manipulation to be composed from simple linear motion primitives. The Cartesian Hand is particularly suited to objects structured around common mechanisms such as threads, pivots, linear guides, plungers, and triggers. We demonstrate cap opening and closing, pipetting, pumping, two-handle manipulation, screwdriving, trigger actuation, and in-grasp reorientation across 35 objects spanning laboratory, manufacturing, and household settings. The same manipulation procedures transfer from a fixed-base robot arm to a humanoid, where we demonstrate bimanual laboratory manipulation using two Cartesian Hands. These results show that versatile in-hand manipulation capability can emerge from a mechanically simple architecture when independent grasping and relative motion are designed directly into the end-effector. We will open-source all software and hardware design. Our website is https://generalroboticslab.com/cartesian_handv1.

0.41