CS Paper Radar

Design and Modeling of a Single-Port Three-Arm Robotic Tool for Minimally Invasive Neurosurgery

Nazia H. Dana, Harith S. Gallage, Ismail A. Auta, Dhanvi Yuvaraj, Ronghuai Qi

cs.RO ·submitted 2026-09-22 21:54 UTC · v1

Abstract

Surgical robots require highly dexterous and compact robotic systems capable of operating effectively within confined anatomical spaces. However, due to limited access provided by a single incision, the miniaturization and maneuverability of these robots still need to be improved. In this paper, we propose the design and modeling of a single-port three-arm robotic tool containing one major cannula (7.14 mm outer diameter (OD)) and three steerable minor cannulas (1.93 mm OD). By integrating the proposed 12 degrees-of-freedom (DoFs) steerable robotic tool with a 7-DoF robotic arm, this robotic system can potentially achieve multi-arm manipulation capability. We present the design of the steerable robotic tool consisting of tendon-driven joints controlled by a compact actuation system, derive the kinematic model, and validate both the static and kinematic models through experiments. The performance is evaluated with the root mean square error (RMSE) and mean absolute error (MAE) computed between the experimental data and the kinematic model.

Comment
6 pages, 11 figures, submitted to IEEE ROBIO 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Design and Validation of an Antagonistic Tendon-Driven Dexterous Robotic Hand with Bidirectional Operation

cs.RO ·2026-09-28 ·Chunghyeon Lee, Hyukjun Kwon, Sungeon Kim, Saehyun Moon, Seokhwan Jeong
similarity 0.59
Abstract

Dexterous robotic hands typically reproduce human hand morphology but inherit its one-sided grasping workspace, requiring wrist or arm reorientation to grasp from the opposite side. Existing reversible hands generally rely on non-anthropomorphic, soft, or task-specific finger arrangements, whereas conventional five-digit anthropomorphic hands remain designed primarily for palmar-side grasping. This paper presents an anthropomorphic, human-scale (200 mm length), lightweight (220 g), 3D-printed, 17-DoF robotic hand built on a bidirectional antagonistic tendon-routing mechanism, in which flexion/extension (except the coupled joint) and abduction/adduction at joints are actively driven without passive return springs. The proposed routing mechanism allows all degrees of freedom to cross their neutral configuration and form grasp closures on either the palmar or dorsal side. Experimental evaluation demonstrates an average motor-to-joint transmission error of 3.0%, an average joint transmission bandwidth of 13.2 Hz, a maximum fingertip force of 29 N, and a positioning repeatability up to 0.15 mm. The hand further achieves a Kapandji score of 8, successfully performs all 33 GRASP Taxonomy grasp types, and performs palmar- and dorsal-side grasping tasks, validating bidirectional operation in a compact, human-scale platform.

0.34

TinyARM-X: A Series of Open-Source, Configurable, and Transparent Torque-Controlled Desktop-Scale Robotic Manipulators

cs.RO ·2026-11-18 ·Nicolas Kosanovic, Jean Chagas Vaz
similarity 0.58
Abstract · 9 pages, 5 figures. Submitted to a robotics Journal. Reviews have not come in yet

Visuomotor policies have demonstrated that imprecise low-cost robots can autonomously complete complex manipulation tasks. However, most inexpensive manipulators rely on compact and rigidly position-controlled servos for actuation, which complicate simulation, operation, and safety. This work introduces TinyARM-X, a framework for easily manufacturable, configurable, and torque-controllable low-cost (<350 USD) serial manipulators. By using a single hardware/software architecture, a <7 Degree of Freedom (DoF) TinyARM can be manually reconfigured to an operational >3 DoF robot within 10 min. Actuator modeling and dynamic compensation enable torque-controlled applications like mixed-reality impedance control teleoperation and simulator force feedback rendering. Experiments include mechanical benchmarking and real-world force-aware telemanipulation. The TinyARM-7 has a payload of 33.5 g, a max speed of 0.77 m/s, and a reach of 210 mm. Moreover, with dynamic compensation, the robot has a backdrive-breakaway force of 1.4 N and a backdrive-running force of 0.7 N. Additionally, Cartesian-Impedance Control (CIC) attains a translational stiffness of >15 N/m. Lastly, the TinyARM-X stack is open-sourced to disseminate accessible desktop-scale torque-controlled robotic manipulation to the community.

0.22

Design and Characterization of a Unified Continuum Robot Actuation Platform

cs.RO ·2026-10-14 ·Yunti Xu, Aedan Mangan, Miheer Potdar, Alex Lu, Tania K. Morimoto
similarity 0.58
Abstract

Continuum robots enable dexterous access to confined spaces in applications such as minimally invasive surgery and industrial inspection. However, their actuation systems are often custom-designed for specific robot architectures and tasks, limiting reuse across publications, institutions, and applications. This paper presents a unified actuation platform that decouples actuation hardware and software from continuum robot design. The platform provides modular actuation across continuum robot classes, scales to a large number of degrees of freedom (DOFs), and integrates with conventional serial manipulators for hybrid architectures. We validate the platform on an open-sourced surgical robotic system and experimentally characterize the actuation modules, achieving sub-millimeter translational accuracy and less than $5^\circ$ rotational error over ranges of $30$~mm and $180^\circ$, respectively. We further demonstrate the platform in two surgical use cases: teleoperation of a continuum camera in a constrained environment and bimanual manipulation using $2.53$~mm concentric-tube-robot-based forceps alongside a conventional wristed instrument. All hardware designs and ROS-based software are open-sourced to facilitate reuse and further research in continuum and surgical robotics.

0.31

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

cs.RO ·2026-09-27 ·Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh +7 more
similarity 0.58
Abstract · Submitted to IEEE ICRA 2027

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

0.32

Contact-Stable Deformable Tissue Simulation Using Implicit Integration and Live-Pose Grasp Constraints for Laparoscopic Surgery Robot Policy Evaluation

cs.RO ·2026-09-22 ·Juahn Oh, Dongho Yee, Jinseok Lee, Jiyul Lee, Yechan Seo +7 more
hot direction similarity 0.57
Abstract · Submitted to IEEE ICRA 2027

Closed-loop evaluation of surgical robots requires tissue that deforms, can be grasped and lifted, and reproduces the anatomy in which the robot will operate. We present a simulator in which this tissue is reconstructed from a fixed-view RGB-D recording of the surgical field, composited to remove the instruments, closed into watertight volumes and tetrahedralised; the pipeline was applied unchanged to three specimens of two species (thirteen organs, 146,061 tetrahedra, no inverted elements). For one specimen, the organs are placed in a bimanual cell in which two Franka FR3 arms operate motorised instruments through 6 mm trocars. The core contribution is the numerical and contact design that keeps this cell stable: implicit integration, simulation meshes separate from collision meshes, numerical guards, and a grasp constraint captured at the live tissue pose. In 45 repeated grasp-lifts, a friction grasp held the tissue in 0 of 15 trials and each constraint grasp in 13 of 15; on displaced tissue, a rest-pose constraint produced one-step snaps of up to 17.8 mm, which live-pose capture eliminates. Against the recording, front-surface depth error is 1.33 to 1.41 mm, organ silhouette IoU is 0.80, and in five grasp-lifts reproduced from video the landmark displacement RMSE is 11.8 mm against 14.2 mm for a static prediction. Biofidelity is not claimed; the environment is intended for closed-loop feasibility, safety, contact and policy screening.

0.32

Ultra-Low-Impedance Robotic Gripper for High-Bandwidth and Transparent Physical Interaction

cs.RO ·2026-08-10 ·Joon Lee, Ari Choi, Seokhwan Jeong
published similarity 0.55
Abstract · ICRA 2026 (Late Breaking Result Poster)

Conventional robotic grippers often use high-ratio transmissions to generate grasping torque and external force sensors to measure physical interaction. High-ratio transmissions increase friction, reflected inertia, and mechanical impedance, while external sensors add hardware complexity. To address these trade-offs, this study proposes a novel 9-DOF, three-fingered Differential Direct-Drive (DDD) gripper that combines DD motors with a low-ratio (1:2) differential transmission. The mechanism centralizes actuator mass at the base to minimize moving-link inertia, while the differential architecture couples two motors in parallel to amplify torque during flexion. Experiments show that the prototype delivers a nominal grasping force of approximately 18 N and a fingertip force of 4.7 N, while maintaining a low motor contribution to system inertia (0.236%) and low passive mechanical impedance, with a maximum measured value of 50.1 N/m when the motors are unpowered. The proposed hardware addresses the trade-offs among torque, physical transparency, and kinematic dexterity, providing a foundation for high-bandwidth interaction and sensorless proprioceptive force estimation.

0.19

PACT: Pose-Robust Actuation Co-Design for Tendon-Driven Robotic Hands

cs.RO ·2026-11-03 ·Prashant Kumar, Rachael Granberry, Taylor Niehues, Andrew A. Stanley, Gabe Pirie
similarity 0.55
Abstract

Humanoid robotic hands must provide sufficient force, speed, and backdrivability within a human-scale envelope. Tendon-driven transmissions address this challenge by relocating actuators to the palm and forearm, but routing paths, moment arms, and capstan dimensions jointly determine both force capability and joint speed, so selecting them sequentially satisfies one requirement at the expense of the other. This paper presents a pose-robust actuation co-design for tendon-driven robot hands (PACT) framework that optimizes tendon routing, moment arms, and capstan dimensions under pose-dependent force requirements and drivetrain-bandwidth constraints. A feasible-force formulation enforces actuator bounds and equilibrium at all joints, while a max-min objective maximizes task-force coverage at the weakest pose. Applied to a four-degree-of-freedom finger, the framework produces an asymmetric N + 1 tendon topology using quasi-direct-drive actuators. Across eight poses, the design achieves task-force coverage of 0.88-1.00 and a predicted 5 Hz minimum isolated-joint flexion/extension bandwidth within a 70th-percentile human-size envelope. Prototype measurements deviate from predictions by up to 24.5%, primarily due to unmodeled transmission losses. These results indicate that co-designing routing with the drivetrain can meet pose-dependent force requirements without relaxing the bandwidth constraint, paving the way for human-sized robotic hands with human-level performance.

0.08

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery

cs.RO ·2026-10-07 ·Charles DeLorey, Michael Brockdorff, Adam Metcalf, Benjamin Calmé, Pietro Valdastri +1 more
similarity 0.55
Abstract · 9 pages, 12 figures

Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.

0.17