CS Paper Radar

Integrated Respiratory Sensing and Gated Control for Autonomous Needle Insertion Via CT Bore Robotic Arm

Emma Huang, Moira Bohley, Krishna Jamakhandi, Rebecca Fellbaum, Sophia Tang, Sean Tutton, Albert Hsiao, Alexander Norbash, Changwei Chen, Derek Chen, Ananya Rao, Lizzie Peiros, Michael C. Yip

cs.RO ·submitted 2026-10-21 21:08 UTC · v1
unusual

Abstract

Currently, CT-guided lung biopsy is a highly manual procedure requiring patient breath-holding, iterative manual needle insertions, and repeated CT confirmation scans to accurately target a tumor. Automating this process within the CT bore--without relying on manual needle placement or patient breath-holding--has the potential to reduce procedure time, patient discomfort, and radiation exposure. In this work, we present an integrated sensing and control system capable of performing a gated needle insertion within the CT bore. The experiments demonstrate the system's ability to track and predict patient breath cycles, perform autonomous respiratory-gated needle insertion, and detect breath cycle anomalies.

Closest papers

Nearest neighbours by meaning across the whole index.

Towards Vacuum-Assisted Robotic Needle Interventions: From Fluid Aspiration to Tissue Biopsy

cs.RO ·2026-11-18 ·Sheena Shabana, Laxmi Nag Laxminarayan Nagesh, Marta Vallejo, Karen Donaldson, Maria Koskinopoulou
similarity 0.58
Abstract · 8 pages, 8 figures, Submitted to the 2027 IEEE International Conference on Robotics and Automation (ICRA)

Robotic ultrasound-guided needle interventions have primarily focused on target localization and accurate needle placement, while the subsequent acquisition of diagnostic material remains comparatively underexplored. Moreover, pleural fluid aspiration and tissue biopsy are typically addressed as separate procedures, despite sharing common requirements for ultrasound guidance, safe access, and sample transport. This work presents a unified robotic framework for ultrasound-guided fluid and tissue extraction using a single vacuum-assisted end effector. The proposed system combines force controlled ultrasound scanning, semantic target identification, automated needle deployment, and procedure specific material acquisition. A coaxial needle assembly and shared pump assisted pathway enable direct pleural fluid aspiration, while controlled cannula actuation provides the additional cutting action required for solid-tissue acquisition. End-to-end evaluation using a Franka Emika Panda robot over 50 phantom trials achieved successful extraction in 23/25 pleural fluid aspiration trials (92\%) and 22/25 tissue acquisition trials (88\%). Following successful tissue-target access, acquisition and transport were completed in all 22 trials.

0.32

Contact-Adaptive Robotic Ultrasound Probe Control for Tissue Exploration and Continuous Task-Relevant Visualization Using Robot-Free Image-Motion Demonstration

cs.RO ·2026-09-27 ·Seong Jeong, Minsung Kim, Dongho Yee, Juahn Oh, Yechan Seo +6 more
hot direction similarity 0.51
Abstract · Submitted to IEEE ICRA 2027

Robotic ultrasound commonly targets standardized views, predefined scanning protocols, or expert-scan reproduction. We target a different role: while a clinician performs the primary procedure, a robotic assistant maintains a clinician-selected view so that changing tissue remains observable. We present contact-adaptive robotic ultrasound monitoring derived from robot-free demonstrations. Sonologger clamps a six-axis inertial sensor to the clinician-operated probe and records synchronized ultrasound and probe-frame relative rotations without a robot, camera, or tracker. Rather than imitating trajectories, the recordings measure which probe axis and sign the clinician uses to correct an image offset. A measured image latency is removed before still-move-still segmentation yields relative-rotation labels; translation is excluded from control because of inertial drift. These measurements parameterize the Demonstration-Informed Image-Motion Controller (DIMC), an interpretable, non-learned controller combined with beam-axis force regulation and an independent safety supervisor with 5 N forced retreat. On a dynamic bladder phantom, DIMC acquired and held a task-relevant view in 7 of 7 blind, pose-paired trials versus 1 of 7 for a static hold (McNemar p = 0.031), and retained the view during syringe-driven hydro-distension while the supervisor bounded the force excursion. The framework offers an operational representation of ultrasound context for contact-adaptive intraoperative monitoring; clinical validation remains future work.

0.29

Anatomy-Aware Prediction of Bronchoscopic Accessibility from 3D CT

cs.CV ·2026-09-29 ·Linkai Peng, Cuiling Sun, Bin Wang, Jamie Rowell, Catherine Gao +8 more
top venuebenchmark similarity 0.50
Abstract · Accepted in MICCAI 2026

Pre-operative planning for bronchoscopy is critical for the diagnosis of lung lesions. Current accessibility assessment relies on subjective manual inspection of CT scans, which is time-consuming and prone to inter-observer variability. In this paper, we formalize bronchoscopy accessibility prediction as a novel supervised learning task and present the first end-to-end framework to address it. We propose an Anatomy-Aware Mixture-of-Experts (MoE) model that integrates specialized modules: a CT Expert for local morphological features, a Lobe Expert for anatomical priors, and a Path Geometry Expert that encodes the sequential constraints of the bronchial tree. To support this task, we curated the first clinical dataset of 438 cases with pre-operative CT scans and documented procedural outcomes. Experimental results demonstrate that our method achieves an AUROC of 0.8052, significantly outperforming both state-of-the-art baselines and experienced human experts. This work establishes a new benchmark for computer-aided interventional planning in pulmonary medicine. Our data and code will be publicly available at https://nubagcilab.github.io/BronchoAccess/.

0.37

A Master-to-Simulation Interface with Demonstration-Trajectory Guidance for Vascular Intervention

cs.RO ·2026-10-14 ·Mingyu Zou, Shuxiang Guo, Sheng Cao, Pengcheng Li, Jian Guo +2 more
similarity 0.49
Abstract · 6 pages, 3 figures, submitted to IEEE journals

Robotic vascular intervention can reduce radiation exposure to physicians and improve manipulation stability, but effective guidance remains challenging because conventional fluoroscopic images provide limited spatial information. This paper developed a vascular intervention interactive system that connects a real robotic master controller with the SOFA(Simulation Open Framework Architecture) physical simulation platform and reused successful operation trajectories as visual guidance in physical phantom experiments. Experiments were conducted to validate the master-to-SOFA control loop and to compare three guidance conditions: no guidance, centerline guidance, and successful-trajectory guidance. The control validation results showed reliable command delivery under velocity-mode operation. In the physical phantom experiment, centerline guidance showed no obvious improvement over no guidance. In contrast, successful trajectory guidance provided a clear performance benefit. Compared with the no-guidance condition, it reduced task completion time, collision number, rollback number, and rotation number by approximately 66.8%, 34.3%, 55.6%, and 66.7%, respectively. These results indicate that successful trajectories obtained under instrument-vessel interaction can provide practical guidance cues, offering a simple and effective visual assistance strategy for robotic vascular intervention experiments.

0.32

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.48
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30

Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal Sounds

cs.SD ·2026-10-27 ·Shang-Ran Huang, Fu-Shun Hsu, Ji-Chang Huang, Chuan Chen, Shou-Zen Fan +3 more
similarity 0.48
Abstract

Tracheal auscultation is recommended by clinical practice guidelines, and required by some U.S. state regulations, for monitoring ventilation during procedural sedation and monitored anesthesia care. However, continuous auscultation with a conventional stethoscope is impractical, susceptible to ambient noise, and difficult to interpret. We developed the Artificial Intelligence Respiratory MOnitoring Device (Airmod), an FDA-cleared software as a medical device (510(k) K242798) that continuously monitors tracheal sounds and estimates breath-to-breath respiratory rate in real time. In this paper, we describe its software architecture and key processing modules. Ambient noise is suppressed by active noise control, using a normalized least-mean-square adaptive filter with a dual-microphone electronic stethoscope. A multiclass convolutional bidirectional gated recurrent unit (CNN-BiGRU) model detects inhalations and exhalations in 15-s inference windows. It was trained on HF_Tracheal_V2, a new database of 373 continuous tracheal sound recordings (8,521 min; 107,644 labeled inhalations) from 369 subjects under sedation. To handle continuous acoustic streaming, Airmod runs inference on overlapping 15-s windows. It refines the detected inhalations by removing incomplete events, low-energy false positives, and double counts, concatenates them into a history list, and estimates respiratory rate from the mean period of the last three breaths. On the test set, at the default 2-s prediction interval with refinement enabled, inhalation detection achieved a sensitivity of 0.828, a positive predictive value of 0.832, and an F1-score of 0.830. Airmod also broadcasts the noise-cancelled tracheal sound and displays a real-time spectrogram to help clinicians recognize respiratory abnormalities.

0.21

BronchoTop: Bronchoscopy Navigation via RGB-Only Topological Localization

cs.CV ·2026-09-23 ·Clara Tomasini, Ana Cristina Murillo, Luis Riazuelo
unusual similarity 0.48
Abstract

Accurate localization of the bronchoscope within the bronchial tree is essential for clinicians to be able to reach target lesions, perform biopsies and avoid misidentification of airway segments during diagnostic and therapeutic procedures. However, existing navigation systems typically rely on patient-specific CT scans or additional external sensors, increasing cost, setup time and patient radiation exposure. This work presents BronchoTop, a real-time, RGB-only framework for topological bronchoscopy localization that eliminates the need for patient-specific data. BronchoTop estimates scope location relative to a generic airway model through four modules: lumen detection and tracking, lumen-branch label association, probabilistic scope location estimation, and switch verification. By using only standard bronchoscopy video input, BronchoTop provides practical, real-time navigational assistance to physicians. Evaluation on phantom, simulated and real data demonstrates state-of-the-art accuracy, improving existing approaches performance by over 20% on real bronchoscopy sequences. BronchoTop is the first published framework including both the localization algorithms as well as all the real data used, together with code to generate additional simulations, encouraging and facilitating further developments and benchmarking. The results highlight BronchoTop's potential to enhance procedural safety, efficiency and accessibility in clinical and robotic bronchoscopy.

0.32

Contrast-Free Autonomous Navigation of Untethered Endovascular Microrobots Using Single-Plane Fluoroscopy

cs.RO ·2026-08-31 ·Husnu Halid Alabay, Tuan-Anh Le, Ping Wang, Hakan Ceylan
similarity 0.48
Abstract · 34 pages, 9374 words

Reliable three-dimensional (3D) navigation of magnetically actuated untethered microrobots remains a major barrier to clinical translation. X-ray fluoroscopy is the standard real-time imaging modality for endovascular procedures, but single-plane fluoroscopy provides only a two-dimensional (2D) projection, eliminating depth information and complicating autonomous navigation. Recovering this information through biplane imaging or repeated contrast-enhanced angiography increases procedural complexity, radiation exposure, or contrast burden. Here, we introduce VISTA (Virtual Integration for Spatial Tracking and Autonomy), a digital twin framework enabling contrast-free autonomous navigation under single-plane fluoroscopy. VISTA reconstructs vascular anatomy as a 3D digital twin, discretizes the vessel centerline into navigation milestones, and assigns the detected 2D robot position to the nearest projected milestone. Consecutive milestones define the local vessel orientation used to generate magnetic actuation commands, converting single-plane fluoroscopic observations into topology-constrained navigation states without requiring contrast injection during navigation. VISTA is demonstrated across anatomically distinct vascular phantoms under continuous flow and within the inferior vena cava of a live rat in vivo. Compared with conventional fluoroscopic human-in-the-loop control, VISTA reduced navigation time by up to 62%, corrective actuation commands by up to 98%, and radiation exposure by up to 57%. These results establish VISTA as a digital twin-guided framework for contrast-free autonomous navigation of untethered endovascular microrobots using widely available single-plane fluoroscopy.

0.31