CS Paper Radar

Measuring the Installed Base: Nordic Health Dataset Catalogues Against HealthDCAT-AP Release 7

Fabio Rovai

cs.DL cs.CY ·submitted 2026-08-27 21:23 UTC · v1

Abstract

The European Health Data Space requires member states to publish machine readable descriptions of the health datasets available for secondary use, and the European Commission publishes HealthDCAT-AP as the metadata profile those descriptions are meant to satisfy. The profile has been designed and validated against curated examples, never against the catalogues already live. We report that measurement for the Nordic region. On 25 August 2026 the 11 Nordic national catalogues harvested by the European data portal held 2,811 dataset descriptions carrying the EU health theme, and none satisfies all eight properties HealthDCAT-AP Release 7 makes mandatory on a dataset. Three of the eight are present on exactly zero records across five countries. Set beside the portal's own quality assessment, which validates DCAT-AP and never mentions the health profile, this is not a health extension skipped on top of sound generic practice: no Nordic catalogue reaches the assessment's top rating band, 5 of the 11 are reported at zero per cent DCAT-AP compliant, and the properties surviving in both layers are the ones a human types into a form, not the ones needing a value bound to a controlled vocabulary. Two further results follow. Finland contributes 2,259 descriptions to the European portal of which 1,146 carry a theme, and not one uses the EU theme authority vocabulary, so a European health filter returns no Finnish dataset at all. Separately, the authority namespace answers HTTP 200 with a well formed empty document for terms it never defined, letting 1,238 datasets across the wider portal carry theme IRIs that resolve to nothing while passing any status code check. We publish the vocabulary, the shapes and the harvesters, record every verdict as a dated observation rather than a property of the dataset, and report the five errors this discipline caught before publication.

Closest papers

Nearest neighbours by meaning across the whole index.

OmniSynth: A Meta-Evaluation Framework for Benchmarking the Quality of Missingness-Inclusive Synthetic Health Data

cs.DB ·2026-11-09 ·Annabel Zhu, Océane Doremus, Ariel Guerra-Adames, Marta Avalos-Fernandez, Emmanuel Lagarde +2 more
similarity 0.56
Abstract · Accepted to the BIBM'26 ARRL-Health'26 Workshop

Synthetic data are an emerging solution to the reproducibility crisis in machine learning for health, driven by data privacy restrictions surrounding electronic health records. Yet no consensus exists on how to evaluate synthetic health data quality, existing metrics functionally overlook missingness despite its prevalence in clinical data, and benchmarking frameworks have never been empirically validated. We introduce OmniSynth, a modular Python benchmarking suite that evaluates synthetic tabular data across fidelity, missingness similarity, utility, and privacy - the first framework to explicitly evaluate missingness as a distinct dimension of synthetic data fidelity. OmniSynth further proposes a meta-evaluation procedure that stress-tests evaluation performance under controlled degradation scenarios, providing a systematic characterization of how an evaluation framework behaves across datasets, sample sizes, and variable types. Applying this procedure to OmniSynth in two health datasets (Pima Indians Diabetes; MIMIC-IV-ED), we found that scores responded monotonically to degradation, three of four novel missingness metrics captured induced missing data patterns, and individual metric contributions to the scoring system were empirically justified.

0.20

How Well Do Benchmarks Evaluate LLMs' Use for Personal Health Informatics?

cs.HC ·2026-11-10 ·Fatemeh Mirhosseini, Yasaman S. Sefidgar
benchmark similarity 0.55
Abstract

Benchmarking is a valuable technique for advancing the capabilities of Large Language Models (LLMs), including in personal health informatics. There are growing efforts on benchmark creation for personal health data activities. However, it is unclear whether and how well these efforts align with needs and considerations of personal health informatics process. Addressing this need, we first analyzed 53,587 tasks across eight benchmarks related to personal health informatics and characterized the space of benchmark design. We then contrasted our observations of design choices with personal informatics theories and empirical knowledge. We find significant mismatches between existing benchmark design and domain guidelines and understanding. This lack of alignment limits the utility of the evidence current benchmarks offer about LLM capabilities. We use domain knowledge to highlight capabilities benchmarks should include and discuss opportunities our work enables for taking a human-centered and domain-driven approach to benchmark design.

0.38

Extending the W3C Data Privacy Vocabulary to Cover the German Health Data Use Act - Lessons Learned

cs.CY ·2026-10-27 ·Julian Flake, Christian Henke, Alessandra S. Kuntz, Matthias Löbe, Harshvardhan J. Pandit +1 more
published similarity 0.53
Abstract

Finding, sharing, and reusing data requires common interoperable vocabularies to adequately describe machine-actionable data policies. Semantic Web standards are a proven way to express such information describing data access and reuse. Narrative descriptions get a stable and agreed meaning by formal definitions of terms that have a globally unique identifier. The Data Privacy Vocabulary (DPV) represents a community standard for privacy, data protection, and related topics. DPV uses modular namespaces to define jurisdictions, such as "EU", and to represent concepts from laws within that jurisdiction, such as the General Data Protection Regulation (GDPR) and the European Health Data Space (EHDS). In this work, we present the creation of a DPV extension representing the German Health Data Use Act (Gesundheitsdatennutzungsgesetz (GDNG)) that has been set into force in March 2024. The GDNG regulates sharing and using health data for secondary use, such as research purposes and policymaking. It builds the German legal foundation for the future EHDS as the European initiative and regulation providing rules for sharing of health data within Europe. The parallel development of the EHDS and GDNG extensions resulted in many shared concepts, which contributed to an overarching extension: the DPV sector health extension. It sets the foundation of aligned privacy terms for future EHDS member states looking to build a national vocabulary aligned with the EHDS. All extensions were released as draft extensions with the latest DPV version 2.3, released 25th of February 2026.

0.33

TRACER, a time-to-event EHR foundation model for disease detection across health systems

cs.CE cs.LG ·2026-10-29 ·Mara Pleasure, Ekaterina Redekop, Vedrana Ivezic, Rushikesh Kulkarni, Aaron Chin +2 more
similarity 0.52
Abstract

Foundation models trained on longitudinal electronic health records (EHRs) can predict clinical diagnoses years in the future, making them a potential tool for disease screening. We developed TRACER (Temporal Risk Assessment with Clinical EHR Representations), a decoder-based foundation model pretrained on data from over 4.5 million patients from four health systems, and evaluated it on 16 incident diseases at 1-, 2-, and 5-year horizons in more than 2 million patients from two health systems excluded from model development. In contrast to typical evaluations that focus on global metrics (e.g., AUROC), we measured performance at the low false-positive rates that are realistic for screening. We found that TRACER retained its discrimination in external health systems, and at 95% specificity, the patients it flagged were up to eight times more likely to be diagnosed within a year than unselected patients. Evaluating at this operating point also revealed what global metrics alone did not: detection and false-alert burden varied across diseases and health systems, even when discrimination appeared stable. Our results illustrate the potential of foundation models for screening and underscore the need for evaluation in health systems excluded from development to assess disease detection and false-alert burden at levels appropriate for intended clinical use.}

0.16

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

cs.LG ·2026-08-13 ·Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala +1 more
benchmark similarity 0.52
Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

0.04

A Comparative Framework for Evaluating Foundation Models on Tabular Data: A Case Study in Healthcare

cs.LG cs.CY ·2026-08-26 ·Majid Lotfian Delouee, Sjors G. J. G. In 't Veld, Martijn C. Schut
similarity 0.50
Abstract · 32 pages

Tabular data is the most common format in clinical practice, encompassing laboratory results, medication records, diagnostic codes, and patient demographics. As foundation models for tabular data have grown in number and variety, a practical question has become harder to answer: which model should a clinician or data scientist actually choose for a given task, and why? Existing surveys catalogue what these models can do, but they stop short of providing a structured way to compare them against the specific demands of a real application. We introduce \system{}, a comparative evaluation framework that scores and ranks tabular foundation models (TFMs) across six clinically meaningful dimensions: how well a model generalizes to new datasets, how effectively it protects patient privacy, how much data it needs to perform well, how it scales with growing datasets and feature spaces, how interpretable its predictions are to clinicians, and how fairly it performs across patient subgroups. Each dimension is broken down into measurable sub-components, and groups of sub-components can optionally be combined into supplementary compound scores, called super-metrics, that provide a diagnostic view of how a model performs across several dimensions simultaneously. To show how the framework works in practice, we apply it to two healthcare use cases, screening for iron deficiency and predicting heart failure, demonstrating how the same set of metrics leads to different model rankings depending on what matters most in each clinical context. We also provide a taxonomy of 45 TFMs organized by their underlying architecture, which serves as a reference for researchers and practitioners looking to navigate this rapidly expanding field.

0.24

A Multimodal Type 2 Diabetes Registry on DHIS2: A Design and Feasibility Study with the AI-READI Dataset

cs.CY cs.DB ·2026-10-30 ·Saptarshi Purkayastha, Aiswarya Nandan Perumbilly, Zhenan Yin, Sherri L. Bucher
code/data similarity 0.50
Abstract

Care for type 2 diabetes increasingly draws on continuous glucose monitors, wearable devices, home sensors, clinical records and retinal images, yet few open platforms have been shown to hold all of these for the same person. We asked three questions of DHIS2, the open-source health information system that ministries of health in about 80 countries run nationally: whether an unmodified Tracker program can represent these modalities together (RQ1), which design choices its row-per-event data model forces for dense sensor streams (RQ2), and what a bulk loader must do to load such data correctly (RQ3). We designed a registry of 27 program stages and 445 data elements, loaded the AI-READI dataset of 2,280 participants into it, and verified the result field by field against the source files. The program held every loaded modality in 8.09 million events. Dense streams were stored as hourly summaries aligned across modalities; electrocardiograms, diagnoses and 118,480 retinal images were stored as one event per record. The event model ruled out storing raw readings, and hourly summaries reduced the wearable and glucose volume about 26-fold. An audit of the loader found defects that shared one pattern: a failure that looked like success. We state five lessons for DHIS2 Tracker clients that address this pattern. Verification of all 64.9 million stored values found four defects, all missing, duplicated or artifactual records rather than wrong values, and none after their repair; an independent recomputation of the glucose summaries agreed on all 464,210 values compared. The paper offers implementation guidance for DHIS2 implementers and for users of AI-READI; it does not evaluate clinical use. Analytics at this scale, use by clinicians and live device feeds remain to be shown.

0.37

Explainable Transformer Models for Clinical Prediction Tasks on Structured Electronic Health Records

cs.LG ·2026-08-20 ·Jun Ni Du, Lukas Adamek, Maxim Kryukov, Flavio Dormont, Ziv Bar-Joseph +2 more
top venuebenchmark similarity 0.50
Abstract · Accepted at MLHC 2026; to appear in Proceedings of Machine Learning Research (PMLR)

Predictive models over structured electronic health records (EHRs) remain central to machine learning for healthcare, but few have jointly emphasized quantitative laboratory information and interpretability with respect to input medical events. We present BERT-LER, a BERT-style model for coded EHR timelines pretrained and fine-tuned from a de-identified EHR dataset of 75 million patients, that encodes laboratory test results as discrete tokens while retaining graded information through percentile-based binning, paired with Integrated Gradients for token-level attributions grounded in the input EHR sequence. We benchmark our approach on the public EHRShot benchmark suite and on an asthma severity progression study based on real-world data. This addresses a methodological gap in EHR foundation-style modeling by unifying laboratory value representation and explainability in a single framework, while assessing whether both predictive performance and explanations generalize beyond standard clinical prediction tasks. Across EHRShot and asthma tasks, BERT-LER achieves predictive performance that is competitive with, and on laboratory-related tasks often exceeds, publicly available benchmark models, and provides attributions that align with clinically known risk factors. Our architecture and explainability approach can be applied to many therapeutic areas and prediction tasks using language models trained on structured EHRs.

0.42