FISICA: A Deployed Service for Plantar-Pressure and Posture Assessment with Ontology-Grounded Recommendation

Juhwan Song, Heejung Kim, Juntae Noh, Jonghak Ryu, Huiju Park, Junseong Lee, Dohyeon Ahn, Byungwoo Jo

cs.CV cs.HCcs.IR ·submitted 2026-08-29 15:39 UTC · v1
unusual

Abstract

FISICA is a body-assessment and recommendation service running in production. One standing session with two photographs returns foot-loading measures, posture coordinates, a driven 3D avatar, a visual report, and ranked shoe and exercise candidates. Measurement comes from a purpose-built scale carrying 634 force-sensitive elements on a 1 cm grid and four load cells, and a rule-based evaluator controls every recommendation while a language model only explains the stored result. The method contribution is the avatar. Instead of mapping a measured angle onto a rig through a tuned gain, we measure the avatar with the same function used on the subject and solve until the two agree, on a sampling-invariant spinal metric that separated a normal from a kyphotic record by 7.2 degrees against 0.9 degrees for a single-joint formulation. In production, general APIs respond at a 0.023 s median, plantar-pressure analysis at 0.45 s, and recommendation at 2.16 s to 2.26 s with the rule-based portion under one second in every trial. The served keypoint graph reaches 0.960 PCK@0.2 on public data, and the catalog holds 699 shoes with 10,500 typed facts. An approved study supplies the radiographic reference for the validation still ahead.

Comment
31 pages, 17 figures, 25 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury

cs.CV ·2026-10-04 ·Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland +1 more
datasetcode/data similarity 0.55
Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset

0.30

Real-Time Musculoskeletal Surrogates for Pediatric Cerebral Palsy: a Credibility Pilot

cs.CV cs.AI ·2026-08-28 ·Mohammad Arif Ul Alam
similarity 0.53
Abstract

Real-time musculoskeletal (MSK) surrogates could support personalized rehabilitation for children with cerebral palsy (CP), but their credibility depends on subject-wise evaluation, low inference latency, and calibrated uncertainty. We develop a subject-conditioned causal neural surrogate using OpenSim-derived static parameters, temporal joint kinematics, true muscle capacities, and training-only perturbations. On a real pediatric CP gait dataset comprising nine children, we use leave-one-subject-out validation on six development subjects and evaluate a frozen configuration once on three locked test subjects. The surrogate accurately reproduces musculotendon lengths (R-square = 0.92 in development validation and approximately 0.95 on locked subjects; nRMSE < 8%) while requiring only sub-millisecond to few-millisecond neural inference, well below a 100 ms interactive-rehabilitation target. In contrast, direct muscle-force estimation remains unstable at this small, heterogeneous scale: pooled metrics can overstate within-subject, per-muscle accuracy. A Monte Carlo credibility pilot further shows that propagating only +/-5% anthropometry and muscle-capacity variation produces severely overconfident nominal 90% intervals (approximately 4% force coverage and below 1% MT-length coverage). These results establish a leakage-free evaluation and credibility framework for pediatric MSK surrogates, while identifying force modeling and epistemic uncertainty as the central next challenges for clinically credible digital twins.

0.24

Video-Based Markerless Motion Capture for Clinical and Rehabilitation Biomechanics: A PRISMA-ScR Scoping Review of Validated Architectures, Clinical Readiness, and Emerging Methods

cs.CV physics.med-ph ·2026-09-16 ·Florian Delaplace, Elodie Piche, Frédéric Chorin, Raphael Zory
similarity 0.53
Abstract

Background.. Video-based markerless motion capture promises movement analysis without the cost, space and skin-marker constraints of optoelectronic systems, with particular potential for clinical and rehabilitation settings. Whether validated pipelines yet deliver clinically acceptable biomechanics, and how they relate to the underlying computer-vision research, remains unclear. Methods. We conducted a scoping review following the PRISMA extension for Scoping Reviews, with a registered protocol and searches of PubMed, Scopus and IEEE Xplore (January 2015 to February 2026; the computer-vision scan was updated to July 2026). A dual-tier design paired a primary corpus of validated biomechanical studies with a complementary, curated and deliberately non-exhaustive corpus of emerging computer-vision work, used qualitatively. We charted study characteristics, pipeline architecture, validation methods and joint-angle accuracy. Results. We included 117 studies, most published from 2024 onward and conducted on healthy adults walking in a laboratory. Pipelines formed five architectural families across monocular and multi-camera modalities; most reported raw joint angles without biomechanical refinement. Sagittal lower-limb agreement clustered around 5 to 6{\textdegree}, generally short of clinical acceptability, while out-of-plane kinematics, kinetics, and pathological or older populations were rarely validated. Emerging computer-vision building blocks (foundation-model mesh recovery, differentiable inverse kinematics, video-based kinetics) were almost absent from validated studies. Conclusions. Video-based markerless capture is not yet interchangeable with marker-based systems for clinical joint kinematics, and it remains barely validated where rehabilitation needs it most: older and pathological populations, out-of-plane kinematics, and kinetics. Mapping this evidence gap onto emerging computer-vision advances, we propose hypothesis-generating design guidelines, not a validated method, to steer the next generation of pipelines toward accessible, clinically meaningful movement analysis.

0.33

Beyond Cross-Modal Reconstruction: Participant-Level Evaluation of sEMG-Kinematic Coupling in Post-Stroke Gait

cs.LG ·2026-11-18 ·Rafsan Jany, Md Rafid Islam, Mohammad Fahim Islam, Hafiz Abdur Rahman
similarity 0.52
Abstract

Accurate cross-modal reconstruction is often treated as evidence of physiological coupling, although it may simply reflect temporal patterns shared across participants. We tested whether frozen bidirectional models captured subject-specific neuromuscular coupling between electromyographic activity and gait kinematics in 82 held-out able-bodied and 43 post-stroke participants. Complete source-modality removal and cross-participant source substitution, along with a cycle-position-age-sex template baseline, were applied. Learned bilateral asymmetry was also compared with transparent waveform and derivative asymmetry for predicting Performance-Oriented Mobility Assessment (POMA) scores in the case of repeated nested cross-validation. Complete source removal increased reconstruction RMSE by 6.90% for electromyography-to-kinematics and 11.38% in the reverse direction. In contrast, cross-participant substitution increased RMSE by only 1.68% and 1.67%, respectively, while the template reduced RMSE by 2.89% and 0.55%. For POMA prediction, walking speed, age, and sex achieved an MAE of 3.693, compared with 4.229 and 4.427 after adding absolute and signed learned asymmetry, respectively. In all of the 20 repeated evaluations, all asymmetry representations performed worse than the covariate baseline. No localized learned feature remained significant after covariate adjustment and false-discovery-rate correction. The model mainly relied on shared gait-phase patterns, with no clear subject-specific coupling or added clinical value. Participant-level controls are therefore needed before reconstruction accuracy is treated as evidence of individualized physiology.

0.20

Novel Ex-vivo Calf Brain Model with Integrated Sub-Skull Force Sensors to Access Simulated Neurosurgical Procedures

cs.RO eess.SY ·2026-09-13 ·Hamad Binhammad, Matheus Ballestero, Mohammed Babgi, Seana Shaka, Nima Hemati +7 more
similarity 0.51
Abstract

Surgical tissue manipulation demands precision; however, tool-tissue manipulation force magnitudes under realistic conditions are rarely quantified. To address this gap, we proposed and validated a portable ex-vivo force-sensing platform that measures tool-tissue interaction forces across the skull-brain interface during simulated neurosurgery. The system involves fresh calf brain tissue, used as a biological surrogate for brain parenchyma, placed in a 3D-printed human skull model equipped with a 6 degree-of-freedom force/torque sensor and a real-time data acquisition system. Five validation protocols assessed the accuracy and dynamic fidelity of the platform against ground-truth measurement, static accuracy and linearity using calibrated weights (0.5-50 g), minimum detectable force, spatial consistency across different anatomical regions, effect of surgical draping, and long-duration stability. Across protocols, measured forces showed excellent agreement with reference loads (correlation R = 0.9997), with RMSE < 0.005 N and mean relative error under 2%. The platform reliably detected low-magnitude forces down to 1 g (9.8 mN), while surgical drapes introduced no meaningful signal distortion and prolonged recordings exhibited minimal drift. Overall, the proposed framework provides objective, high-fidelity force quantification for skill training and performance assessment using fresh calf brain tissue and may serve as a foundation for force-based evaluation across other surgical procedures. Future work will integrate clinically used surgical instruments to increase procedural realism and will progress toward clinical trials to evaluate usability, educational impact, and translational relevance in practice-adjacent settings.

0.25

A Personalized Dynamic Balance Evaluation Paradigm for Hip Exoskeleton-Assisted Walking under Unexpected Ground Perturbations

cs.RO cs.LGeess.SY ·2026-09-13 ·Yun Chen, Oluwasegun T. Akinniyi, Qiang Zhang
published similarity 0.51
Abstract · 8 pages, 6 figures. Accepted to the 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026)

Hip exoskeletons may improve recovery from unexpected gait perturbations, yet personalizing assistance remains difficult because balance is multidimensional and human-in-the-loop experiments are small-sample and noisy. We present a participant-specific composite balance cost that integrates seven biomechanical sub-metrics spanning margin of stability, center-of-mass dynamics, and whole-body angular momentum. The sub-metrics are converted to direction-aligned, dimensionless cost features, and nonnegative fusion weights are learned on the simplex. Coupled with an empirical-Bayes hierarchical model, the learned-composite selector estimates each tested condition's posterior probability of being best, P(best), and a high-probability candidate set with size $K_{0.8}$. The framework was evaluated with three participants walking at 1.1 m/s during unilateral belt-slip perturbations across 46 hip-assistance conditions. In the full-budget analysis (B = 4 repeats per condition), the selector concentrated 80% of the posterior probability within 1 to 5 of 46 conditions, compared with 2 to 12 for equal-weight fusion and 4 to 37 for principal component analysis fusion. This smaller candidate set could shorten personalization experiments and limit participants' exposure to repeated perturbations in future studies. Selected-condition trials showed lower observed composite costs than no-torque trials, with nominal p < 0.05 for P2 and P3. Leave-one-repeat-out refits yielded positive mean held-out rank correlations for all participants and moderate stability of the learned weights and candidate sets. These proof-of-concept results support participant-specific composite balance evaluation for candidate selection in perturbation-based human-in-the-loop experiments.

0.45

Autonomous Telerehabilitation via Skeletal Motion Prediction and Joint-Level Performance Assessment

cs.CV cs.LG ·2026-08-12 ·Lara Pereira, João Ruivo Paulo, Pedro Santos, Paulo Peixoto
published similarity 0.50
Abstract · Accepted at IEEE RO-MAN2026

Autonomous rehabilitation systems must not only recognize human motion but also provide structured feedback to support users without continuous therapist supervision. This paper presents a telerehabilitation pipeline that integrates skeleton-based exercise quality assessment and short-term motion prediction into a two-module system operating on marker-free RGB video. A self-attentive Bidirectional LSTM performs exercise quality classification using MMD-NCA metric learning, while a graph-based motion prediction module computes per-joint position errors between predicted and observed poses, generating spatially localized deviation signals. Each module is evaluated independently on established benchmarks: the classifier achieves 96.45% mean-class accuracy on squat sequences from the PROZIS dataset, and the adopted STARS predictor achieves a mean MPJPE of 75.8 mm at 560 ms on Human3.6M, outperforming graph and recurrent baselines across all prediction horizons. The framework is designed for eventual deployment in assistive robotics and home-based rehabilitation contexts; end-to-end integration and clinical validation are important directions for future work. By combining motion recognition and prediction in a single system, this work contributes a step toward autonomous, feedback-driven telerehabilitation, for more accessible and scalable rehabilitation solutions.

0.23

Biomechanical 3D Body: Self-Supervised Distillation of Biomechanical Pose from a 3D Body Foundation Model

cs.CV ·2026-08-30 ·R. James Cotton, J. D. Peiffer, Lucinda Williamson, John Leske, Georgios Pavlakos
publishedcode/data similarity 0.50
Abstract · Accepted to the ECCV 2026 Workshop MoCha

State-of-the-art monocular body recovery methods predict mesh vertices and angles on the corresponding kinematic tree, but their outputs lack biomechanically defined joint angles that downstream applications like clinical and biomechanical analyses require. We extend an existing foundation model, SAM-3D-Body, with an additional biomechanical prediction head that, from a single RGB image, regresses the joint angles and scales of a biomechanical model. Training this model presents a challenge, as there are limited datasets of paired images and biomechanical fits. To overcome this, we supervise biomechanical outputs with in-loop optimized targets from a Levenberg-Marquardt solver performing inverse kinematics fits against markers from the mesh predictions. This allows distilling the biomechanical head from the mesh head, even from unlabeled images. To make this work with GPU-optimized biomechanical models in MuJoCo, the entire model was implemented in JAX using Equinox. We trained this distilled output head on the publicly released SAM-3D-Body dataset. We then validated this model on biomechanical fits to two publicly available marker-based datasets, MoVi and BioCV, as well as movements from a clinical cohort captured with multiview markerless motion capture. The resulting model outperforms existing models for direct regression of biomechanics from images while only slightly underperforming the state-of-the-art monocular biomechanics method that performs more costly inference-time optimization of entire trajectories.

0.51