Novel Ex-vivo Calf Brain Model with Integrated Sub-Skull Force Sensors to Access Simulated Neurosurgical Procedures

Hamad Binhammad, Matheus Ballestero, Mohammed Babgi, Seana Shaka, Nima Hemati, Rothaina Saeedi, Aiden Mazidi, Bianca Giglio, Rukun Dou, Houssem-Eddine Gueziri, Amir Hooshiar, Rolando F. Del Maestro

cs.RO eess.SY ·submitted 2026-09-13 00:11 UTC · v1

Abstract

Surgical tissue manipulation demands precision; however, tool-tissue manipulation force magnitudes under realistic conditions are rarely quantified. To address this gap, we proposed and validated a portable ex-vivo force-sensing platform that measures tool-tissue interaction forces across the skull-brain interface during simulated neurosurgery. The system involves fresh calf brain tissue, used as a biological surrogate for brain parenchyma, placed in a 3D-printed human skull model equipped with a 6 degree-of-freedom force/torque sensor and a real-time data acquisition system. Five validation protocols assessed the accuracy and dynamic fidelity of the platform against ground-truth measurement, static accuracy and linearity using calibrated weights (0.5-50 g), minimum detectable force, spatial consistency across different anatomical regions, effect of surgical draping, and long-duration stability. Across protocols, measured forces showed excellent agreement with reference loads (correlation R = 0.9997), with RMSE < 0.005 N and mean relative error under 2%. The platform reliably detected low-magnitude forces down to 1 g (9.8 mN), while surgical drapes introduced no meaningful signal distortion and prolonged recordings exhibited minimal drift. Overall, the proposed framework provides objective, high-fidelity force quantification for skill training and performance assessment using fresh calf brain tissue and may serve as a foundation for force-based evaluation across other surgical procedures. Future work will integrate clinically used surgical instruments to increase procedural realism and will progress toward clinical trials to evaluate usability, educational impact, and translational relevance in practice-adjacent settings.

Closest papers

Nearest neighbours by meaning across the whole index.

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery

cs.RO ·2026-10-07 ·Charles DeLorey, Michael Brockdorff, Adam Metcalf, Benjamin Calmé, Pietro Valdastri +1 more
similarity 0.61
Abstract · 9 pages, 12 figures

Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.

0.17

Haptic Probing for Subsurface-Aware Force Distribution on Layered Soft Tissue

cs.RO ·2026-11-17 ·Lei Shi, Xiaoyu Wang, Cheng Zhou, Yongjian Liu, Jing Wang +3 more
position similarity 0.58
Abstract

Force-regulated contact with layered soft tissue fails most often where the subsurface composition changes: controllers infer the substrate from the loading signal alone, so the estimate guiding them lags the change---more acutely, we argue, over compliant than over bone-backed tissue. We remove that lag with a separate haptic channel. Under a light preload, a brief low-amplitude excitation lets the local dynamic admittance discriminate muscle from bone-backed tissue relative to a per-subject baseline, before task force is applied---active haptic sensing used to commit a control decision rather than to characterise tissue. A force- and tactile-driven distribution law then consumes that regime throughout execution: an instantaneous allocation equalises pressure across the engaged fingertips, while the regime sets the admissible pressure and hence the area the hand must recruit to deliver the target force---making patch area a controlled variable rather than a by-product. Probing, switches and recruitment are priced in a partitioned passivity budget, so safety monitoring cannot suppress the probe and a refused recruitment forfeits force tracking rather than the pressure bound. We report force tracking and pressure uniformity over curved, migrating contact on three human subjects, with regime labels from anatomical landmarks.

0.21

Proprioceptive Finger Force Estimation for Reliable Box Manipulation

cs.RO ·2026-10-28 ·Junha Cha, Chanwoo Kim, Kisang Park, Yeoncheol Jang, Doyoung Kim +3 more
code/data similarity 0.58
Abstract · Project page: https://finger-force-estimation.pages.dev/

Reliable box manipulation requires successful placement without damage, which depends on maintaining sufficient contact force without excessive loading. We hypothesize that per-finger force feedback improves manipulation reliability relative to open-loop finger commands. To this end, we present Finger External-Force Estimation from Proprioceptive SignaLs (FEEL), an uncertainty-aware residual method that estimates per-finger external force magnitude from proprioceptive histories. Our method combines a calibrated virtual-spring estimate with a residual distribution predicted by a Mixture Density Network (MDN) and requires no dedicated contact sensors during deployment. The estimated force is used for continuous per-finger adaptation, while predictive uncertainty is evaluated as an empirical signal of ambiguity in proprioceptive force estimation. Across ten fingers and contact forces spanning 0-20 N, our method achieves a mean RMSE of 0.251 N, reducing the error by 92.8% relative to the virtual spring and by 9.4% relative to an end-to-end MDN. In box pick-and-place, force adaptation maintains task success at 10/10 and increases both damage-free outcomes and reliability from 7/10 to 10/10. The project page is available at https://finger-force-estimation.pages.dev/

0.35

Mechanical behaviour of the intact brain-skull interface under tension, compression and shear

cs.CE ·2026-11-12 ·Sajjad Arzemanzadeh, Karol Miller, Ron Kikinis, Adam Wittek
similarity 0.58
Abstract

The brain-skull interface governs the boundary/contact conditions of the brain in computational head models, yet its mechanical behaviour remains poorly characterised experimentally. We characterised the brain-skull interface by testing brain-skull complex samples (skull bone, meninges and brain tissue in their native arrangement) excised from 19 sheep cadaver heads under uniaxial tension and compression at strain rates of 0.002, 0.02 and 0.2 s$^{-1}$ and simple shear at 0.02 s$^{-1}$. Histology confirmed that the meningeal layers remained intact and attached to the brain and skull after excision. We acquired magnetic resonance images of every sample, reconstructed their geometry and developed a sample-specific finite element model of each experiment. We represented the brain tissue using a second-order Ogden hyperelastic model and the brain-skull interface using a cohesive zone model. Using inverse finite element analysis, we first calibrated the brain tissue parameters for each subject. Keeping these parameters fixed, we then identified the interface parameters from the corresponding brain-skull complex specimen. The brain tissue shear modulus increased with strain rate from 0.94 $\pm$ 0.16 kPa at 0.002 s$^{-1}$ to 1.60 $\pm$ 0.30 kPa at 0.2 s$^{-1}$. In contrast, the interface properties (maximum normal traction 2.35 $\pm$ 0.81 kPa, maximum tangential traction 4.14 $\pm$ 0.97 kPa, and fracture energy 0.35 $\pm$ 0.14 N m$^{-1}$) showed no significant dependence on strain rate or loading mode. In all samples, failure occurred within the subarachnoid space. Neither a rigid brain-skull connection nor frictionless sliding contact with separation reproduced the measured mechanical response or failure mode of the brain-skull interface. Our experimentally derived cohesive zone model provides a realistic representation of the brain-skull interface for computational head models.

0.32

Single-View RGB-D Force--Deformation Estimation for Robotic Manipulation of Elasto-Plastic Materials

cs.RO ·2026-11-11 ·Dezhi Sun, Marijn van Hilten, Kenan Niu
published similarity 0.57
Abstract · 7 pages. Accepted at IEEE ROBIO 2026

Persistent deformation complicates elasto-plastic manipulation by coupling physical interaction with spatially distributed shape changes. We investigate the force--deformation relationship using a standard robot, a single eye-in-hand RGB-D camera, and intrinsic force estimates. A 7-DoF Franka Emika FR3 performs normal indentations while an Intel RealSense L515 captures pre- and post-contact surfaces. Point-cloud processing localizes deformation and estimates displaced volume. Force--volume characterization includes 27 measurements over nine force levels. A compact multilayer perceptron (MLP), trained on 52 force--volume pairs at four levels, achieves a held-out RMSE of 1.857 N and $R^2=0.440$. A separate comparison shows lower error for a quadratic model at 16 N and for the MLP at 19 and 23.5 N. An eight-step experiment at 4 N per interaction demonstrates cumulative deformation localization from the second indentation onward. These results establish a practical measurement basis for deformation-aware manipulation using intrinsic force estimates and single-view geometry.

0.22

Design and Validation of a Robotic Knee Exoskeleton with Musculoskeletal Simulation-Derived Biological Torque Control

cs.RO ·2026-10-30 ·Rajiv V. Joshi, Jimin An, Ilseung Park, Dawit Lee, Inseung Kang
code/data similarity 0.56
Abstract · 8 pages, 5 figures, 2 tables

Data-driven controllers have enabled lower-limb robotic exoskeletons to adapt assistance to the user across many tasks. A leading example is biological torque control, which estimates the user's own joint moment from onboard sensors and assists in proportion to that estimate. However, its estimators are trained on data recorded with the target device, so deploying the controller on new hardware requires collecting new data. Existing open-source efforts release hardware, software, or controllers separately, so this data collection must still be repeated on the assembled device. Here, we present an open-source knee exoskeleton, built from off-the-shelf components and widely available fabrication tools, with a biological torque controller derived entirely from simulation. A muscle-driven imitation policy reproduces squatting motions from an open biomechanics dataset, and the resulting knee moments are distilled into an estimator that uses only onboard sensors, so no training data are recorded on the device. In seven able-bodied participants, assistance reduced peak biological knee extension moment by 21.5% and peak vastus medialis activation by 26.7% during squatting, relative to squatting without the exoskeleton (p<0.05). Our results demonstrate that a biological torque controller derived from simulation can transfer to physical hardware without device-specific data collection. Because the hardware and training pipeline are released together, research groups can train and compare knee exoskeleton controllers on shared hardware without additional data collection overhead.

0.22

Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury

cs.CV ·2026-10-04 ·Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland +1 more
datasetcode/data similarity 0.55
Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset

0.30

Object-Centered Reconstruction for Vision-Based 3D Force Estimation

cs.RO ·2026-09-20 ·Zhonghao Zhang, Mingyeung Wu, Hao Yang, Ayberk Acar, Alan Kuntz +1 more
similarity 0.55
Abstract

Excessive force may damage tissue and increase the risk of anastomotic leakage in robotic colorectal surgery. Although the da Vinci 5 provides force sensing, this capability is unavailable on earlier da Vinci systems and many other surgical robotic platforms. In this work, we present a vision-based pipeline for estimating 3D interaction forces from soft-tissue deformation in stereo endoscopic video. We dynamically reconstruct the tissue point cloud in an object-centered coordinate frame, track tissue points with geometric constraints, and predict the 3D force vector with a neural network. We progressively evaluate the pipeline on rubber-glove phantoms, ex vivo porcine colons, and in vivo colorectal surgical video sequences. Under varying tissue orientations and positions within the endoscopic view, as well as different camera viewpoints, the proposed method achieves average root mean square error (RMSEs) of 0.77 N and 1.30 N on the phantom and porcine colon, respectively. Compared with the camera-frame representation, the object-centered representation reduces average RMSE by 51.3% and 56.7%, while geometry-constrained tracking reduces RMSE by 19.8% and 25.3% compared with CoTracker. We further qualitatively demonstrate the feasibility of vision-based force estimation on an in vivo colorectal surgical sequence, as a step toward clinical translation of vision-based, sensorless force estimation.

0.18