CS Paper Radar

Mechanical behaviour of the intact brain-skull interface under tension, compression and shear

Sajjad Arzemanzadeh, Karol Miller, Ron Kikinis, Adam Wittek

cs.CE ·submitted 2026-11-12 02:43 UTC · v1

Abstract

The brain-skull interface governs the boundary/contact conditions of the brain in computational head models, yet its mechanical behaviour remains poorly characterised experimentally. We characterised the brain-skull interface by testing brain-skull complex samples (skull bone, meninges and brain tissue in their native arrangement) excised from 19 sheep cadaver heads under uniaxial tension and compression at strain rates of 0.002, 0.02 and 0.2 s$^{-1}$ and simple shear at 0.02 s$^{-1}$. Histology confirmed that the meningeal layers remained intact and attached to the brain and skull after excision. We acquired magnetic resonance images of every sample, reconstructed their geometry and developed a sample-specific finite element model of each experiment. We represented the brain tissue using a second-order Ogden hyperelastic model and the brain-skull interface using a cohesive zone model. Using inverse finite element analysis, we first calibrated the brain tissue parameters for each subject. Keeping these parameters fixed, we then identified the interface parameters from the corresponding brain-skull complex specimen. The brain tissue shear modulus increased with strain rate from 0.94 $\pm$ 0.16 kPa at 0.002 s$^{-1}$ to 1.60 $\pm$ 0.30 kPa at 0.2 s$^{-1}$. In contrast, the interface properties (maximum normal traction 2.35 $\pm$ 0.81 kPa, maximum tangential traction 4.14 $\pm$ 0.97 kPa, and fracture energy 0.35 $\pm$ 0.14 N m$^{-1}$) showed no significant dependence on strain rate or loading mode. In all samples, failure occurred within the subarachnoid space. Neither a rigid brain-skull connection nor frictionless sliding contact with separation reproduced the measured mechanical response or failure mode of the brain-skull interface. Our experimentally derived cohesive zone model provides a realistic representation of the brain-skull interface for computational head models.

Closest papers

Nearest neighbours by meaning across the whole index.

Modeling Fat-shift for Improved Head Segmentation from MRI Scans using a Probabilistic Model

cs.CV ·2026-10-31 ·Merle Diedrichsen, Koen Van Leemput, Douglas N. Greve, Oula Puonti, Axel Thielscher
unusual similarity 0.58
Abstract

Personalized computational head models for biophysical simulations rely on accurate whole-head segmentations from T1-weighted (T1w) magnetic resonance imaging (MRI) scans. While T1w scans provide excellent contrast for intracranial anatomy, extracerebral tissues have partly almost no signal (compact bone) and also suffer from the so-called chemical shift artifact, which affects the fatty tissues in MRI and causes them to spatially shift in the frequency encoding direction of the scan. This artifact occurs primarily in two structures of the head: the spongy bone, a fatty compartment inside the compact bone, and the subcutaneous fat, located directly underneath the skin. The frequency-encoding direction is often set in the superior-inferior direction, causing the fatty tissues to shift down and, as a result, making the skull appear thinner than it actually is. Existing segmentation methods do not model this artifact, consequently leading to inaccurate labeling of the skull and scalp, which introduces a bias in biophysical simulations. The direction and magnitude of the fat-shift can be determined from the scan parameters, thus making it possible to explicitly model the shift and to recover the correct anatomy. This study introduces a probabilistic model that uses variational inference to segment head and brain structures from a T1w scan while accounting for the fat-shift artifact. The proposed Fat-shift-informed Label Optimization of the Whole head (FLOW) method reconstructs extracerebral anatomy more accurately than a fat-shift-agnostic segmentation approach while maintaining high segmentation accuracy in all other structures. FLOW-based fat-shift corrected segmentations significantly reduce bias in electric field simulations compared to a segmentation method that does not model the shift.

0.27

Novel Ex-vivo Calf Brain Model with Integrated Sub-Skull Force Sensors to Access Simulated Neurosurgical Procedures

cs.RO eess.SY ·2026-09-13 ·Hamad Binhammad, Matheus Ballestero, Mohammed Babgi, Seana Shaka, Nima Hemati +7 more
similarity 0.58
Abstract

Surgical tissue manipulation demands precision; however, tool-tissue manipulation force magnitudes under realistic conditions are rarely quantified. To address this gap, we proposed and validated a portable ex-vivo force-sensing platform that measures tool-tissue interaction forces across the skull-brain interface during simulated neurosurgery. The system involves fresh calf brain tissue, used as a biological surrogate for brain parenchyma, placed in a 3D-printed human skull model equipped with a 6 degree-of-freedom force/torque sensor and a real-time data acquisition system. Five validation protocols assessed the accuracy and dynamic fidelity of the platform against ground-truth measurement, static accuracy and linearity using calibrated weights (0.5-50 g), minimum detectable force, spatial consistency across different anatomical regions, effect of surgical draping, and long-duration stability. Across protocols, measured forces showed excellent agreement with reference loads (correlation R = 0.9997), with RMSE < 0.005 N and mean relative error under 2%. The platform reliably detected low-magnitude forces down to 1 g (9.8 mN), while surgical drapes introduced no meaningful signal distortion and prolonged recordings exhibited minimal drift. Overall, the proposed framework provides objective, high-fidelity force quantification for skill training and performance assessment using fresh calf brain tissue and may serve as a foundation for force-based evaluation across other surgical procedures. Future work will integrate clinically used surgical instruments to increase procedural realism and will progress toward clinical trials to evaluate usability, educational impact, and translational relevance in practice-adjacent settings.

0.25

TRACE: Artifact-Robust Statistical Shape Modeling from Imperfect Surface Scans - A Case Study in Craniosynostosis 3D Photography

cs.CV cs.AI ·2026-08-22 ·Sanjay Bhandari, Nawazish Khan, Alzbeta Novotna, Tiffany Jeong, Loretta Bowman +5 more
published similarity 0.50
Abstract · Accepted at ShapeMI workshop at MICCAI 2026

Craniosynostosis severity analysis increasingly relies on statistical shape models (SSMs) to quantify cranial morphology, but most existing workflows depend on computed tomography or heavily curated three-dimensional (3D) photographs. Raw clinical 3D photographs provide a radiation-free and repeatable alternative, yet often contain shoulders, hands, hair, clothing, scanner noise, and incomplete boundaries that corrupt correspondences. We introduce the Template-constrained Robust Artifact-aware Correspondence Estimation (TRACE) framework, an unsupervised method for constructing SSMs directly from artifact-contaminated clinical 3D head photographs. TRACE predicts sparse anatomically corresponding head-surface control points from the raw point cloud, refines them through a coarse-to-fine Surface-Aware Deformation cascade, and uses thin-plate spline warping to deform a clean template mesh into a subject-specific head reconstruction. This template-constrained formulation keeps dense correspondences on clinically relevant head anatomy while suppressing non-head artifacts. The correspondence module is decoupled from the point-cloud encoder, enabling the same deformation pipeline to be paired with different backbones, including PointNet, DGCNN, and Point Transformer V3. Across all backbones, TRACE substantially improves surface sampling, topology preservation, and shape-model quality over prior SSM methods, providing a scalable foundation for photograph-based craniosynostosis shape analysis and a framework that may extend to other artifact-contaminated surface scans when an appropriate clean template is available.

0.42

A$^3$PreCore: Robust Rigid Registration for Native FLAIR-Space Brain-Mask Transfer

cs.CV eess.IV ·2026-10-14 ·Elmira Mirzabeigi, Zahra Khalilzad, Taylor Snowden-Richardson, Jesus Eduardo Lugo Arce, Jodie R. Gawryluk +2 more
unusual similarity 0.48
Abstract

Reliable brain-mask transfer into native fluid-attenuated inversion recovery (FLAIR) space can fail when T1-to-FLAIR rigid registration is unstable. We developed A$^3$PreCore, a six-degree-of-freedom rigid-registration strategy that aligns the full bias-corrected T1-weighted image to native FLAIR using normalized mutual information while preserving the established T1-space anatomical mask. We also introduced extended quantitative quality control (E-QC), which characterizes mask extent, field-of-view-relative position, FLAIR intensity support, boundary support, inferior morphology, and pairwise geometric disagreement. In 78 participants with paired T1-weighted and FLAIR imaging, A$^3$PreCore was compared with fsl_anat and the Brain Extraction Tool (BET). Gross rigid-body misregistration occurred in 21/78 fsl_anat outputs (26.9%) and 0/78 A$^3$PreCore outputs (exact two-sided McNemar p=9.54 x 10^-7). Among 57 participants without gross fsl_anat misregistration, A$^3$PreCore preserved close agreement (median Dice=0.993; median paired Delta NMI=-0.00007, p=0.429). A$^3$PreCore remained broadly concordant with BET (median Dice=0.955), with less inferior and extracranial extension in representative comparisons. Method-blinded neuroscientists ranked A$^3$PreCore first in 35/40 participants (87.5%). E-QC additionally exposed severe orientation-related disagreement not evident from global descriptors or centroid displacement alone. These findings support A$^3$PreCore as a robust native-FLAIR brain-mask transfer strategy and E-QC as a complementary framework for multidimensional mask characterization and participant-specific geometric quality control.

0.22

Modelling the human-exoskeleton interaction interface - Benchmarking MuJoCo's deformable model

cs.RO ·2026-11-18 ·Lisette Masselink, Xiaolong Zhu Thomas George Thuruthel, Mohamed Irfan Refai
similarity 0.46
Abstract

The human-exoskeleton interaction interface, consisting of the exoskeleton attachment and the underlying human soft tissue, can affect the transfer of assistance. MuJoCo's \textit{flexcomp} has been previously used to model the soft tissue, but its accuracy has not been benchmarked against a finite element model. We benchmarked the \textit{flexcomp} Saint Venant-Kirchhoff (StVK) and Stable Neo-Hookean (SNH) models against COMSOL's Yeoh model in three cases: \textit{case 1}) spherical indentation, \textit{case 2}) compression, and \textit{case 3}) compression of a thigh. We compared force and strain energy as a function of indentation depth, hysteresis and computation time. MuJoCo's models capture force trends with a correlation of 0.97-0.99, but showed a stiffer response, which could be attributed to the volumetric locking of the linear finite elements. The MuJoCo models systematically underestimated hysteresis as MuJoCo's Rayleigh damping could not substitute a viscoelastic model. Moreover, MuJoCo's computational advantage was speed dependent: it was 2-2.5 times faster for spherical indentation, but COMSOL was faster for the other cases, which have more degrees of freedom and contacts. Although MuJoCo's \textit{flexcomp} offers a combination of soft-tissue modelling and multibody dynamics, the limitations regarding the stiffening and hysteresis should be addressed to be used for the analysis of the human-exoskeleton interaction interface.

0.27

Vision Tomography: Towards Portable 3D Bidirectional Face-Skull Inference from Visual Data

cs.CV ·2026-10-27 ·Zidu Wang, Meng Xu, Miao Xu, Hengyuan Ma, Jiankuo Zhao +3 more
code/data similarity 0.45
Abstract · Submitted to TIP, under review

Traditional computed tomography (CT) can capture paired 3D face and skull geometry, but it remains costly, fixed in location, and exposes patients to radiation. For applications such as remote diagnostics, digital healthcare, forensic identification, missing-person investigation, and archaeological analysis, there is an urgent need for a portable, safe, and accessible solution to capture 3D skull geometry. In this work, we introduce Vision Tomography (VT), a concept and framework capable of reconstructing paired 3D face-skull geometry from various visual modalities, and also enabling joint manipulation of 3D facial and skull geometry. To achieve this, we first construct a dataset of over 200 samples, where each case includes a CT-based skull, a CT-based face, and a high-fidelity textured face scan. Secondly, we propose a novel dense ray matching registration method that ensures topological consistency across face, skull, and their tissue correspondences. Building on this registration, we introduce the 3D Bidirectional Face-Skull Morphable Model (BFSM) as the foundation of Vision Tomography, which enables shape inference between the face and skull through a shared coefficient space, while also modeling tissue thickness variation to support one-to-many facial reconstructions from the same skull, reflecting individual facial changes such as age or body fat. Finally, we demonstrate the effectiveness of Vision Tomography across various forensic and medical applications, including paired 3D face-skull reconstruction from images or sketches and predicting surgical outcomes with joint face-skull editing. Extensive experiments confirm the robustness and accuracy of our method. Vision Tomography is available at https://github.com/wang-zidu/BFSM

0.35

Tensor-based Brain Surface Modeling and Analysis

cs.CV q-bio.NC ·2026-09-03 ·Moo K. Chung, Keith J. Worsley, Steve Robbins, Alan C. Evans
top venuehighly cited similarity 0.45
Abstract

We present a unified computational approach to tensor-based morphometry in detecting the brain surface shape differences between two clinical groups based on magnetic resonance images. Our approach is novel in a sense that we combined surface modeling, surface data smoothing and statistical analysis in a coherent unified mathematical framework. The cerebral cortex has the topology of a 2D highly convoluted sheet. Between two different clinical groups, the local surface area and curvature of the cortex may differ. It is highly likely that such surface shape differences are not uniform over the whole cortex. By computing how such surface metrics differ, the regions of the most rapid structural differences can be localized. To increase the signal to noise ratio, diffusion smoothing based on the explicit estimation of Laplace-Beltrami operator has been developed and applied to the surface metrics. As an illustration, we demonstrate how this new tensor-based surface morphometry can be applied in localizing the cortical regions of the gray matter tissue growth and loss in the brain images longitudinally collected in the group of children.

0.74

Concurrent two-scale topology optimization of printable bone scaffolds via rectified-flow generation and exact latent-space refinement

cs.LG physics.comp-ph ·2026-10-18 ·Reza T Batley, Sourav Saha
benchmarkunusual similarity 0.45
Abstract

Bone scaffolds must reconcile a macroscale mechanical response with microscale geometric feasibility, yet conventional approaches to their design restrict attainable constitutive properties. This work presents a concurrent two-scale topology optimization framework; a conditional rectified flow generates periodic lattice microstructures, which are then refined in latent space by exact finite-element homogenization sensitivities. The resulting unit-cell geometries and their spatial assignments are jointly optimized under mechanical and feature-size constraints. In a distal rabbit femur benchmark, all eight flow-started refinements produce printable cells with maximum relative errors under 1\% across six prescribed engineering moduli. Constructing the implant from a single tiled cell reproduces intact whole-femur compliance within 0.1\% and regional strain energy within 0.35\% under four loading conditions. In human femoral reconstruction, multiscale concurrent optimization produces a cortical mid-shaft scaffold with porosity 63\% while satisfying the compliance constraint within 2\% under walking and stair-climbing loads. It achieves an 84\% porosity on a proximal cancellous scaffold with strain-energy deviations below 0.25\% under the same loads. Analysis of the learned representations reveals distinct architectural families in latent space. Further, the attention heads of the rectified-flow transformer specialize for spatial shifts -- learning the analogue of a finite-difference stencil -- and coordinate symmetries, with ablations showing their influence on generated topologies. These results establish a route to printable, mechanically constrained scaffold designs. The framework is general enough for extending to many other multiscale structural design applications including topology-microstructure co-design in metal additive manufacturing.

0.22