Exposing the Invisible: Detecting Stealthy Parameter-Based Cyber-Attacks on Inverter Synchronization Loops

Zaint A. Alexakis, Michal M. Drewniak, Charalambos Konstantinou

eess.SY ·submitted 2026-08-31 10:48 UTC · v1

Abstract

The increasing integration of Internet-of-Things (IoT) technologies for monitoring and control of inverter-based resources (IBRs) has expanded the attack surface, enabling stealthy manipulation of controller parameters through vulnerable supervisory control interfaces. Phase-locked loops (PLLs) emerge as prime targets, as they interact with all control loops and critically influence the dynamic response of grid-following (GFL) converters. This paper analyzes the underlying threat model to elucidate the mechanisms enabling such stealthy behavior and conducts a thorough stability and transient response analysis to characterize how PLL tampering can degrade system performance without necessarily destabilizing the system. The results reveal critical interactions among frequency estimation, control, and synchronization that can significantly reduce stability margins. To counter the stealthy nature of these attacks, a modified PLL is proposed that exposes gain variations through shifts in its equilibrium points while preserving conventional PLL performance. Experimental results validate the effectiveness of the proposed approach in detecting PLL cyber-attacks.

Closest papers

Nearest neighbours by meaning across the whole index.

Attack-Resiliency Analytics for Wide-Area Control Systems in Smart Grids

eess.SY ·2026-09-29 ·Mohammad Zakaria Haider, Prabin Mali, Nur Imtiazul Haque, Muhammad Nadeem, Sumit Paudyal +1 more
similarity 0.63
Abstract

Wide-area monitoring, protection, and control (WAMPAC) systems damp inter-area oscillations in large interconnected grids, but their reliance on synchronized PMU measurements carried over wide-area networks exposes them to false data injection (FDI) attacks. This paper presents an attack-resiliency analytics framework that formally models the coupled dynamics of the wide-area damping loop, automatic generation control, and the governor and excitation systems, and formulates the optimal stealthy FDI attack as a mixed-integer linear program (MILP). The anomaly detection model (ADM) enters as a replaceable constraint set: either a static bad-data detection (BDD) rule or a boundary learned from benign operation calibrated to a common false-positive rate. On the IEEE 39 and 118 bus systems, with reference dynamics validated on an OPAL-RT hardware-in-the-loop testbed, the optimal attack with wide-area access attains 3.3 and 8.1 times the benign objective and reaches a 0.5Hz frequency excursion more than twice as fast as an attack confined to automatic generation control. Learned boundaries reduce the attack objective by 15.5 55.0% and prevent over-frequency relay trips in all configurations, with feasible stealthy attacks remaining in every case, and residual risk tracks the width of the learned boundary rather than the detector family.

0.31

System-Level Factors Influencing AGC Cyber-Attack Success and RAS Vulnerability in Multi-Area Grids

eess.SY ·2026-10-30 ·Abdulmannan Ajabnoor, Zhi Jin Zhang, Maryam Saeedifard, Dominic Groß
published similarity 0.61
Abstract

Automatic generation control (AGC) stabilizes frequency and scheduled power exchanges among interconnected areas, yet its reliance on communication networks introduces cyber-vulnerabilities. This work examines coordinated AGC cyber-attacks in the presence of remedial action schemes (RAS) and identifies operating conditions under which an attacker can drive grid frequency beyond safe limits while evading RAS. A feedback-based attack policy is used to manipulate AGC signals and steer system frequency toward unsafe trajectories. Then, a large nested-loop parametric sweep---spanning attacked-area inertia relative to its interconnected neighboring area, AGC capacity versus maximum tie-line transfer, AGC update rate, load damping, and bi-directional power transfers---generates over 1.45 million scenarios. These are classified using a decision tree to establish guidelines to distinguish successful from unsuccessful attacks based on frequency deviations. The resulting vulnerability guidelines are validated on a three-area system using phasor-domain simulations with IEEE 9-bus area models, detailed turbine--governor dynamics, and under/over-frequency load and generation shedding. Results show that specific combinations of AGC capacity, inertia distribution, and pre-attack tie-line loading increase the likelihood of successful attacks, offering operators actionable criteria for identifying vulnerable operating conditions.

0.41

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

eess.SY ·2026-08-11 ·Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun
similarity 0.57
Abstract

The rapid growth of large language model (LLM) services is expanding AI data centers (AIDCs), increasing electricity demand and associated carbon emissions. Renewable energy integration can mitigate these impacts but also strengthens the coupling between AIDC loads and inverter-interfaced generation, creating cross-domain cyber-physical vulnerabilities. Specifically, adversarial AI requests alter AIDC power demand, whereas inverter control tampering modifies source-side dynamics, and their combined impact on system stability varies with generation forecast and demand response uncertainties. To this end, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework under computing-power coordinated attacks. First, the framework maps adversarial AI requests to AIDC power variations and represents uncertainties in attack-induced demand responses and photovoltaic (PV) forecasts through confidence-weighted realizations. Then, impedance based stability analysis combines these realizations with bounded inverter parameter tampering to construct attack reachable domains and identify critical attack time windows. Furthermore, a separate criterion identifies fixed coordinated attack vectors that retain destabilizing capability throughout each selected window. Case studies demonstrate that, unlike either attack component applied alone, coordinated attacks within identified critical windows induce sustained inverter frequency oscillations with peak absolute deviations exceeding 20% of nominal frequency, whereas the evaluated out-of-window response remains bounded. The proposed method further identifies critical attack windows and the associated coordinated attack vectors.

0.04

DC Voltage Control Dominated Oscillations in Electromechanical Frequency Range - Insights from Synchronous Coefficient Reduction Effect of IBR Plants and Network Interactions

eess.SY ·2026-11-09 ·Qiang Fu, Siqi Bu
top venue similarity 0.57
Abstract

Large-scale integration of inverter-based resources (IBRs) is widely known to cause subsynchronous oscillations. This paper investigates a distinct class of oscillations that occur in the electromechanical frequency range (EFR), referred to as EFOs, and are dominated by the DC voltage control (DVC) loops of grid-following IBRs rather than synchronous generator-like controls or phase-locked loops (PLLs). Although open-loop oscillation modes of DVC loops are subsynchronous, the corresponding closed-loop dominant oscillation mode related to DVC can shift downward into the EFR without retuning the control parameters. This frequency shift is caused by network-mediated interactions among the IBRs, which introduce a negative synchronous coefficient into the DVC oscillation loop. This synchronous coefficient reduction effect (SCRE) becomes stronger as the IBR plant scale increases and/or as the minimum eigenvalue of the network admittance matrix decreases. Furthermore, a complex vector-based stability analysis method is proposed, and a stability criterion for DVC-EFOs is derived. Finally, the analytical conclusions are validated using a practical power system configuration implemented in Simulink. The SCRE differs from traditional explanations, in which the open-loop oscillation modes are already located in the EFR, and provides new insight into DVC-dominated oscillations in the EFR for integration of IBR plants.

0.42

Hierarchical Sensor-Spoofing Defence Framework for Networked DC Microgrids via Cyber-Physical Coordination

eess.SY ·2026-08-13 ·Mengxiang Liu, Xin Zhang, Shiyi Zhao, Ruilong Deng
top venue similarity 0.55
Abstract · IEEE TSG

In parallel to the cyber attack that manipulates the reference points of distributed energy resources (DERs) by maliciously accessing the remote monitoring and control system, the vulnerability of voltage/current sensors to electromagnetic interference (EMI) in the physical domain has been widely discussed. Existing research efforts against sensor spoofing attacks can be classified into physical prevention and cyber detection/mitigation. These defence methods each have strengths and weaknesses in balancing cost, security, and performance in a single DER, yet systematic research on their multi-layer efficient coordination across DERs remains limited. Towards this end, this paper proposes a hierarchical framework to detect and mitigate sensor spoofing attacks in networked microgrids (NMGs) via {multi-layer cyber-physical coordination}. It requires only to deploy physical prevention technologies at critical points, i.e., the local points of common coupling (PCC) of MGs, such that cyber detection/mitigation algorithms can be adopted based on the secured sensor readings to counter sensor spoofing attacks in DERs. The framework employs an MG-DER coordinated proactive detection scheme to strategically trigger parameter perturbations, under which the intelligent sensor spoofing attacks can be {effectively} disclosed. Afterwards, mitigation schemes based on MG-DER coordination are activated to recursively and accurately estimate sensor biases. Experiments on a cyber-physical DC NMG testbed confirm the framework's effectiveness across diverse attack scenarios.

0.29

Transient Triggering Grid-Forming Synchronization Control Under Voltage and Frequency Dips

eess.SY ·2026-09-30 ·Dewan Mahnaaz Mahmud, Vinu Thomas, Bogdan Marinescu, Mickaël Hilairet
benchmark similarity 0.55
Abstract

Grid-forming (GFM) inverters are gaining attention as a promising alternative for conventional synchronous generators in the modern power systems. Unlike conventional synchronous generators, GFM inverters have limited overcurrent capability that makes them vulnerable during large disturbances. During disturbances i.e., voltage and frequency dips, GFM inverters are pushed into current-limited operation to protect the semiconductor switches. This causes the internal angle of the GFM inverters to accelerate and lose synchronism with the rest of the grid. To address this limitation, this article proposes a transient triggering grid-forming (TTGFM) synchronization control to enhance the synchronization stability performance under voltage and frequency dips. This method uses two feedback signals; terminal voltage and the difference between unsaturated and saturated power to adjust the internal angle which is generated by power synchronization loop (PSL) of the GFM inverters. These two signals manipulates the internal reference angle generation that act as a virtual braking mechanism. This mechanism limits the angle acceleration during voltage and frequency dips without requiring an extra supervisory signal or parameters to tune. The proposed method is benchmarked against two state-of-the-art synchronization enhancement schemes and validated through high-fidelity electromagnetic transient (EMT) simulations with a grid dynamic equivalent (GDE) model in MATLAB/Simulink\textsuperscript{\textregistered}. An analytical framework is developed to derive the synchronization instability mechanism and the critical limits of the stability margins. Generalization of the GDE model further shows that the TTGFM control is not restricted to a single configuration but is applicable to any standard benchmark system.

0.23

Covert System Identification Under Timing Constraints: A Static Linear Model and Its Detectability Implications

eess.SY cs.CR ·2026-11-09 ·Victor Mattos, Guilherme Sobreira, Amit Bhaya, Alan Oliveira de Sá, Charles B. Prado +3 more
published similarity 0.55
Abstract · Presented at the 27th International Symposium on Measurement and Control in Robotics (ISMCR 2026), Rio de Janeiro, Brazil. Proceedings forth…

This paper studies covert system identification in cyber-physical systems, where an attacker infers plant dynamics while attempting to remain stealthy. We introduce a lightweight static linear model in which the time to execute a setpoint change is proportional to the commanded speed difference. On a Siemens PROFINET testbed this gain captures the drive's ramp response accurately but not its terminal overshoot. That omitted transient becomes the attacker's main exposure: on real traces, the residual left by the linear masking procedure is detected by two anomaly monitors, Process-Aware Stealthy-Attack Detection (PASAD) and the CUSUM change detector. Across the cascade identification and staircase attack strategies defined in the paper, the stealth boundary relates to the plant's own settling transients, a structural limit for this class of models under the adopted detector-calibration regime. Comparison against dynamic models obtained by N4SID, trained at multiple excitation amplitudes, shows that the evaluated N4SID models do not improve stealth over the structure-informed ramp model. Since per-cycle computation is negligible for both procedures, the binding trade-off is not inference cost but whether the attacker can acquire and refresh a model without injecting detectable perturbations.

0.29

Enhancing Transient Stability of VSG-Controlled Converters Under Grid Frequency Disturbances

eess.SY ·2026-11-13 ·B. Li, Y. Zhang, X. Wang, S. Yang, Z. Hao +1 more
similarity 0.54
Abstract

Strong damping feedback can substantially improve the transient synchronization stability of renewable energy converters employing virtual synchronous generator (VSG) control. However, conventional damping feedback uses the nominal frequency as its reference. When the frequency of a weak grid deviates from nominal, strong damping tends to keep the VSG frequency near nominal. This can sustain a frequency difference between the VSG and the grid and compromise transient synchronization. To address this problem, this paper proposes a complex-frequency-based method to estimate the grid reference frequency from local terminal measurements. The estimated frequency replaces the nominal reference in the VSG synchronization loop, so that damping acts on the frequency difference between the VSG and the real grid. Controller hardware-in-the-loop tests validate the effectiveness of the proposed method under grid frequency disturbances and its robustness to grid parameter uncertainty and adverse grid conditions.

0.26