CS Paper Radar

PyDoseRT Proton: A GPU Pencil-Beam Engine with a Convolutional Residual-Correction Network for Fast Proton Dose Calculation

Lukas Zimmermann, Hermann Fuchs, Attila Simkó, Gerd Heilemann

cs.CV physics.med-ph ·submitted 2026-09-01 10:11 UTC · v1

Abstract

Architecture category. Hybrid method: a physics-based analytical pencil-beam (PB) dose engine followed by a 3-D convolutional residual-correction network (RepVGG-U-Net). We addressed the DoseRAD2026 proton dose-prediction task with PyDoseRT Proton, a GPU-accelerated engine implemented in PyTorch and augmented by a learned residual toward Monte Carlo (MC) accuracy. A double-Gaussian PB kernel was calibrated to GATE/Geant4 integrated depth doses in water in two stages: a classical per-energy curve fit, then a gradient-based fit of the full 3-D dose through the PyTorch physics engine as it retains a differentiable execution path for gradient-based optimization of dose-dependent objectives. The engine computes each beamlet on a beam's-eye-view (BEV) lattice with variance-preserving Gaussian splitting, an analytic nuclear halo, and a Fermi-Eyges heterogeneity term, then rotates the result into the patient frame. Additionally, a compact residual U-Net predicts an additive correction in BEV space. It is conditioned on voxelwise material-label embeddings, a discrete energy embedding and spot size. The same model was used for all anatomical sites (thoracic and abdominal). It was trained with a patient-space L1 objective emphasizing the scored high-dose region and multi-scale BEV deep supervision. The submitted CT configuration obtained preliminary-test beamlet MAE 0.0066, image-z IDD distance 0.0025, plan MAE 0.0049, 98.30\% gamma pass rate (1\%/1 mm), and DVH error 0.460.

Comment
DoseRAD 2026 report - Team DoseHappens

Closest papers

Nearest neighbours by meaning across the whole index.

BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction

cs.CV physics.med-ph ·2026-09-04 ·Chen Cheng, Michael Ferraro, James Grover, David E J Waddington, Emily Hewson
similarity 0.69
Abstract · 14 pages, 5 figures

To enable accurate and rapid photon control point and proton beamlet dose calculation in the DoseRAD2026 challenge, we present BEAM3R, a dose estimation framework operating in beam's-eye-view (BEV). Our core innovation combines a Mamba-3 state-space depth-sequence core with physics-based transport conditioning to model long-range depth transport without expensive 3D convolutions. BEAM3R shares a 2D CNN encoder-decoder architecture for photon and proton dose tasks, processing per-plane BEV slices. Proton beamlets are conditioned on water equivalent thickness and remaining range, encoding the parameters determining Bragg peak position. Photon models use a bidirectional Mamba-3 core to capture dose contributions from materials downstream of the calculation point, while the proton model uses a forward core with learned energy-prefix tokens and a Bragg-peak refinement module. To reduce interpolation artifacts and support high spatial resolution, we introduce axial grid alignment of BEV lattices with CT slices and an implicit super-resolution representation via sub-pixel phase packing, evaluated by a differentiable Triton-accelerated resampler that reconstructs packed cubic B-spline coefficients directly in CT space. For MRI-based tasks, synthetic CTs (sCT) are generated by a patch-based conditional GAN with a SwinUNETR backbone. On the preliminary DoseRAD2026 test set, CT-to-photon and CT-to-proton models achieved 1%/1 mm local gamma pass rates of 96.8% and 96.0%, with stratified plan-level MAEs of 0.0041 and 0.0079. Substituting sCT reduced gamma pass rates to 89.7% for photon and 75.4% proton plan level doses, with stratified plan-level MAEs of 0.0093 and 0.0336. Standardised runtimes were 23.4 s and 18.4 s for CT-to-photon and CT-to-proton prediction, increasing to 39.7 s and 42.8 s for the corresponding MRI-based pipelines.

0.19

Optimization of Deep Learning Model for Denoising Dose Profiles in Proton Therapy

eess.IV q-bio.QM ·2026-09-30 ·Junaid Jawaid, Matteo Spezialetti, Gabriele Libardi, Giovanni Stilo, Filippo Mignosi
similarity 0.68
Abstract

Proton therapy offers a dosimetric advantage over conventional radiotherapy through the Bragg peak, enabling precise dose delivery to the tumour while sparing surrounding tissue. Monte Carlo (MC) simulation provides the most accurate dose calculation but is computationally expensive for clinical workflows. A promising compromise is to simulate with a reduced number of primary histories and recover a high-quality dose distribution through a deep learning denoising step. In this work, we take a 3D multiscale U-Net from recent literature as a case study and investigate two improvements critical for clinical deployment. First, we replace the standard MSE training objective with a differentiable $γ$-index-based loss, extended to native 3D operation, and demonstrate that directly optimising the clinical evaluation metric yields a mean Gamma Passing Rate of 99.47\% at 2mm/2\% and 95.67\% at 1mm/1\% on the test set, compared to 92.10\% and 71.13\% for MSE. Second, we apply L1-norm structured filter pruning to reduce the model's memory footprint, achieving a 13.3\% parameter reduction with negligible performance loss under partial pruning, and 20\% reduction under full-block pruning after fine-tuning.

0.09

Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning

cs.CV physics.med-phcs.LG ·2026-08-27 ·Ankit Bhattacharjee, Sougata Maity, Santam Chakraborty, Indranil Mallick
code/data similarity 0.61
Abstract · The paper consists of 22 pages, 4 figures, 6 tables. The end-to-end pipeline of Dose-PlanNet will soon be made available on the GitHub repos…

Automating prostate radiotherapy treatment planning is dosimetrically complex, particularly for extreme hypofractionated regimens. In this study, we introduce Dose-PlanNet, a physics-guided 3D deep learning architecture designed to predict dose distributions. This model's performance was evaluated on a cohort of patients treated in a prospective trial where two different dose fractionation regimens were employed. Dose-PlanNet achieved comparable target coverage ($D_{95}$), though statistical analysis revealed a marginal reduction in target homogeneity ($p<0.001$) offset. However the model achieved statistically significant improvements in high-dose organ-at-risk sparing ($p<0.001$). When evaluated against strict Prospective Randomized protocol volumetric constraints, automated plans met prespecified clinical acceptance criteria in $11$ out of $14$ Moderate Hypofraction Arm plans and $9$ out of $12$ Stereotactic Body Radiation Therapy Arm plans. This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy workflows while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.

0.36

Learning the Dose Manifold: A Latent Diffusion Framework for Volumetric Dose Prediction in Automated Radiotherapy Treatment Planning

cs.CV ·2026-10-19 ·J. Boyer-Chammard, R. Vauclin, M. C. Biston, P. Maury, M. Gau +5 more
similarity 0.59
Abstract · 27 pages, 7 figures plus graphical abstract

Automated treatment planning (ATP) aims to reduce the unwarranted inter-planner variability of manual planning, while improving treatment quality and efficiency. Most ATP pipelines rely on the prediction of the achievable three-dimensional dose distribution for a given anatomy and the subsequent optimization of machine parameters to reproduce it. Diffusion-based methods are largely slice-wise due to the high dimensionality of radiotherapy data, and assume a one-to-one mapping between anatomy and optimal dose despite the multi-objective nature of treatment planning. They are evaluated on their ability to match reference doses and rarely on their integration in ATP frameworks. We present LaDose, a latent diffusion framework for fully volumetric dose prediction. An autoencoder learned on dose distributions, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU. Prescription values are represented as exact scalar vectors that bypass the image encoder, avoiding resampling and latent compression. Multiscale classifier-free guidance allows for the modulation of clinical trade-offs at inference, without retraining or additional labeled data. On 900 clinically delivered head-and-neck volumetric modulated arc therapy plans from five centers, LaDose reached a median absolute error of 1.18 Gy (1.4--1.8\% of the prescription) and was the only one of six frameworks free of systematic bias with respect to the reference distribution. Guidance scales acted predictably on target coverage and organ-at-risk sparing. Integrated with direct aperture optimization, the pipeline generated plans in 15.2 minutes; in a blinded review, senior clinicians rated 14 of 15 plans acceptable without editing.

0.12

DoseBridge: Denoising Diffusion Bridge Model for Dose Prediction in Lung Intensity-Modulated Proton Therapy

cs.CV ·2026-08-10 ·Zerun Zhang, Xiaoda Cong, Xiangkun Xu, Peter Y. Chen, Xuanfeng Ding
similarity 0.56
Abstract

Most radiotherapy dose-prediction models use only CT images and anatomical structures, although intensity-modulated proton therapy (IMPT) dose also depends strongly on beam geometry and available clinical datasets are often small. We present DoseBridge, a denoising diffusion bridge model that uses the patient CT as a structured bridge endpoint and encodes plan-specific beam geometry in a spatially aligned beam mask. Multiscale fusion combines CT, target, organ-at-risk, and beam-mask representations with 1.95% additional parameters. DoseBridge was retrospectively evaluated on single-institution CT images and treatment plans from 52 patients with advanced-stage lung cancer treated with 60 Gy in 30 fractions; 42 cases were used for training and 10 for testing. Performance was assessed using image-similarity, dose-volume, and Lyman-Kutcher-Burman normal-tissue complication probability (NTCP) metrics and compared with two deep-learning models. On the test cohort, DoseBridge achieved a mean absolute error of 4.170 Gy, peak signal-to-noise ratio of 23.06 dB, and structural similarity index of 0.798, outperforming both comparison models on these metrics. Clinical target volume D95 differed from the reference dose by 0.62 +/- 1.6 Gy; signed organ-at-risk mean-dose differences ranged from -0.32 to 0.24 Gy, and NTCP differences were -0.40 +/- 2.2 and 0.52 +/- 3.4 percentage points for acute esophagitis and radiation pneumonitis, respectively. Changing only the beam mask redirected predicted low-dose entrance regions while preserving the high-dose target region. To our knowledge, DoseBridge is the first denoising diffusion bridge model for radiotherapy dose prediction. These results support its feasibility as a beam-aware planning prior for lung IMPT, pending evaluation in larger external cohorts.

0.04

Fast and Precise Learned Charged-Particle Trajectory Regression at the Large Hadron Collider

cs.LG hep-exhep-phphysics.data-an ·2026-09-26 ·Jonathan Renusch, Benjamin Huth, Daniel Murnane, Eleni Xochelli, Doğa Elitez +7 more
similarity 0.54
Abstract

We propose a training recipe that treats charged-particle trajectory parameter regression on high-energy physics detector data as a sequence-modeling task. Kalman filters and linearized least-squares fits have been the classical standard approach for this task: they are optimal estimators for sparsely sampled linear-Gaussian data and are commonly used for trajectory parameter regression (fitting). The classical fitting techniques implemented for this domain reach a final precision of one part in $10^5$ through detailed modeling of detector geometry, material, detection effects and precise numerical integration of the equations of motion through the detector's inhomogeneous magnetic field. With this study, we demonstrate that using a bidirectional gated linear recurrent encoder, one is able to reproduce the full precision of classical track fitting techniques. Using a custom kernel, we also achieve significantly higher throughput during GPU inference, compared to classical fitting software running on similarly priced multi-core CPU servers representing typically employed hardware. Such a speedup would lead to considerable cost savings for the pattern recognition at the Large Hadron Collider. To our knowledge, this is the first end-to-end learned track fit to reach the full precision and, at the same time, offer the opportunity to reduce the computing costs.

0.14

Fine-tuned Normalizing Flows for ALICE Zero Degree Calorimeter Fast Simulation

cs.LG physics.ins-dethep-ex ·2026-08-13 ·Emilia Majerz, Jacek Otwinowski, Witold Dzwinel, Jacek Kitowski
published similarity 0.54
Abstract · This paper has been accepted for presentation at the 16th International Conference on Parallel Processing & Applied Mathematics (PPAM 2026)

Simulating the ALICE Zero Degree Calorimeter (ZDC) neutron detector responses at the LHC is computationally expensive, requiring complex Monte Carlo chains. We develop a generative surrogate, focusing on Normalizing Flows (NFs). Through transfer learning, we pre-train on the full imbalanced dataset and fine-tune specialized models for different particle types ($γ$, $n$, $Λ$, $K_S^0$, $Σ^+$) using two gradual-unfreezing schemes. As standard ZDC metrics like Wasserstein distance overlook conditional structure, we introduce refined metrics: conditional weighted MAE, dispersion ratio, and Jaccard co-activation error, that better capture physics-relevant input-output dependencies and response variability. Our ensemble of fine-tuned models achieves a Wasserstein distance of $1.61 \pm 0.02$, outperforming baselines across all metrics. This work provides a generalizable NF-based framework for LHC detector simulation, combining NFs, conditional fine-tuning, and physics-motivated evaluation.

0.22

Proton Irradiation Characterization of an Open-Source ML Accelerator on a Zynq UltraScale+ MPSoC

cs.AR cs.ETcs.LG ·2026-09-04 ·Saad Memon, Rafal Graczyk, Jan Swakoń, Leszek Grzanka, Sebastian Kusyk +1 more
code/data similarity 0.52
Abstract

As spaceborne computing systems increasingly rely on neural network (NN) accelerators, the opacity of commercial, black-box architectures severely restricts the development of verifiable radiation mitigation strategies. Open-source, register-transfer level (RTL)-accessible accelerators resolve this limitation by enabling user-defined instrumentation, yet few have empirical radiation-response baselines. This work establishes a foundational system-level proton-irradiation baseline for an unmitigated open-source Tensil NN accelerator deployed on a Zynq UltraScale+ SoC executing ResNet-20 inference. Under 20 to 58 MeV proton irradiation, we delivered $4.29 \times 10^{10}$ p/cm$^{2}$ within monitored operational windows. Seven workload interruptions required two restarts of the notebook process, four reboots or board resets, and one power-cycle sequence. Two output-corruption events returned incorrect CIFAR-10 classes without loss of service. In the longer event, the accelerator returned a class absent from the ten-image CIFAR-10 pool for 39 consecutive inputs at normal cadence. The process remained alive, while the kernel log, limited memory test, and sampled power showed no anomaly. Observation of the stuck-class sequence ended with scheduled bitstream reconfiguration. All nine onsets occurred under the nominal 4 cm beam, which exposed the SoC, LPDDR4, and additional board circuitry; none occurred under the 2 cm SoC-centered field. This pattern shows a field association but does not establish LPDDR4 as the cause because field size was confounded with run order and dose. Linux-managed accelerators require end-to-end content checks and recovery that reaches the state in which corruption can persist. This baseline documents availability loss and silent output corruption, supporting future software hardening of COTS FPGA-SoCs for neural-network inference in space systems.

0.59