CS Paper Radar

BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction

Chen Cheng, Michael Ferraro, James Grover, David E J Waddington, Emily Hewson

cs.CV physics.med-ph ·submitted 2026-09-04 05:26 UTC · v1

Abstract

To enable accurate and rapid photon control point and proton beamlet dose calculation in the DoseRAD2026 challenge, we present BEAM3R, a dose estimation framework operating in beam's-eye-view (BEV). Our core innovation combines a Mamba-3 state-space depth-sequence core with physics-based transport conditioning to model long-range depth transport without expensive 3D convolutions. BEAM3R shares a 2D CNN encoder-decoder architecture for photon and proton dose tasks, processing per-plane BEV slices. Proton beamlets are conditioned on water equivalent thickness and remaining range, encoding the parameters determining Bragg peak position. Photon models use a bidirectional Mamba-3 core to capture dose contributions from materials downstream of the calculation point, while the proton model uses a forward core with learned energy-prefix tokens and a Bragg-peak refinement module. To reduce interpolation artifacts and support high spatial resolution, we introduce axial grid alignment of BEV lattices with CT slices and an implicit super-resolution representation via sub-pixel phase packing, evaluated by a differentiable Triton-accelerated resampler that reconstructs packed cubic B-spline coefficients directly in CT space. For MRI-based tasks, synthetic CTs (sCT) are generated by a patch-based conditional GAN with a SwinUNETR backbone. On the preliminary DoseRAD2026 test set, CT-to-photon and CT-to-proton models achieved 1%/1 mm local gamma pass rates of 96.8% and 96.0%, with stratified plan-level MAEs of 0.0041 and 0.0079. Substituting sCT reduced gamma pass rates to 89.7% for photon and 75.4% proton plan level doses, with stratified plan-level MAEs of 0.0093 and 0.0336. Standardised runtimes were 23.4 s and 18.4 s for CT-to-photon and CT-to-proton prediction, increasing to 39.7 s and 42.8 s for the corresponding MRI-based pipelines.

Comment
14 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

PyDoseRT Proton: A GPU Pencil-Beam Engine with a Convolutional Residual-Correction Network for Fast Proton Dose Calculation

cs.CV physics.med-ph ·2026-09-01 ·Lukas Zimmermann, Hermann Fuchs, Attila Simkó, Gerd Heilemann
similarity 0.69
Abstract · DoseRAD 2026 report - Team DoseHappens

Architecture category. Hybrid method: a physics-based analytical pencil-beam (PB) dose engine followed by a 3-D convolutional residual-correction network (RepVGG-U-Net). We addressed the DoseRAD2026 proton dose-prediction task with PyDoseRT Proton, a GPU-accelerated engine implemented in PyTorch and augmented by a learned residual toward Monte Carlo (MC) accuracy. A double-Gaussian PB kernel was calibrated to GATE/Geant4 integrated depth doses in water in two stages: a classical per-energy curve fit, then a gradient-based fit of the full 3-D dose through the PyTorch physics engine as it retains a differentiable execution path for gradient-based optimization of dose-dependent objectives. The engine computes each beamlet on a beam's-eye-view (BEV) lattice with variance-preserving Gaussian splitting, an analytic nuclear halo, and a Fermi-Eyges heterogeneity term, then rotates the result into the patient frame. Additionally, a compact residual U-Net predicts an additive correction in BEV space. It is conditioned on voxelwise material-label embeddings, a discrete energy embedding and spot size. The same model was used for all anatomical sites (thoracic and abdominal). It was trained with a patient-space L1 objective emphasizing the scored high-dose region and multi-scale BEV deep supervision. The submitted CT configuration obtained preliminary-test beamlet MAE 0.0066, image-z IDD distance 0.0025, plan MAE 0.0049, 98.30\% gamma pass rate (1\%/1 mm), and DVH error 0.460.

0.25

Optimization of Deep Learning Model for Denoising Dose Profiles in Proton Therapy

eess.IV q-bio.QM ·2026-09-30 ·Junaid Jawaid, Matteo Spezialetti, Gabriele Libardi, Giovanni Stilo, Filippo Mignosi
similarity 0.64
Abstract

Proton therapy offers a dosimetric advantage over conventional radiotherapy through the Bragg peak, enabling precise dose delivery to the tumour while sparing surrounding tissue. Monte Carlo (MC) simulation provides the most accurate dose calculation but is computationally expensive for clinical workflows. A promising compromise is to simulate with a reduced number of primary histories and recover a high-quality dose distribution through a deep learning denoising step. In this work, we take a 3D multiscale U-Net from recent literature as a case study and investigate two improvements critical for clinical deployment. First, we replace the standard MSE training objective with a differentiable $γ$-index-based loss, extended to native 3D operation, and demonstrate that directly optimising the clinical evaluation metric yields a mean Gamma Passing Rate of 99.47\% at 2mm/2\% and 95.67\% at 1mm/1\% on the test set, compared to 92.10\% and 71.13\% for MSE. Second, we apply L1-norm structured filter pruning to reduce the model's memory footprint, achieving a 13.3\% parameter reduction with negligible performance loss under partial pruning, and 20\% reduction under full-block pruning after fine-tuning.

0.09

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

eess.IV cs.AI ·2026-10-27 ·Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai +6 more
similarity 0.58
Abstract

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

0.25

DoseBridge: Denoising Diffusion Bridge Model for Dose Prediction in Lung Intensity-Modulated Proton Therapy

cs.CV ·2026-08-10 ·Zerun Zhang, Xiaoda Cong, Xiangkun Xu, Peter Y. Chen, Xuanfeng Ding
similarity 0.58
Abstract

Most radiotherapy dose-prediction models use only CT images and anatomical structures, although intensity-modulated proton therapy (IMPT) dose also depends strongly on beam geometry and available clinical datasets are often small. We present DoseBridge, a denoising diffusion bridge model that uses the patient CT as a structured bridge endpoint and encodes plan-specific beam geometry in a spatially aligned beam mask. Multiscale fusion combines CT, target, organ-at-risk, and beam-mask representations with 1.95% additional parameters. DoseBridge was retrospectively evaluated on single-institution CT images and treatment plans from 52 patients with advanced-stage lung cancer treated with 60 Gy in 30 fractions; 42 cases were used for training and 10 for testing. Performance was assessed using image-similarity, dose-volume, and Lyman-Kutcher-Burman normal-tissue complication probability (NTCP) metrics and compared with two deep-learning models. On the test cohort, DoseBridge achieved a mean absolute error of 4.170 Gy, peak signal-to-noise ratio of 23.06 dB, and structural similarity index of 0.798, outperforming both comparison models on these metrics. Clinical target volume D95 differed from the reference dose by 0.62 +/- 1.6 Gy; signed organ-at-risk mean-dose differences ranged from -0.32 to 0.24 Gy, and NTCP differences were -0.40 +/- 2.2 and 0.52 +/- 3.4 percentage points for acute esophagitis and radiation pneumonitis, respectively. Changing only the beam mask redirected predicted low-dose entrance regions while preserving the high-dose target region. To our knowledge, DoseBridge is the first denoising diffusion bridge model for radiotherapy dose prediction. These results support its feasibility as a beam-aware planning prior for lung IMPT, pending evaluation in larger external cohorts.

0.04

Efficient Neural Surrogates for Linear Radiation Transport on the Lattice and Hohlraum benchmarks

cs.AI hep-lat ·2026-10-03 ·Carmelo Gonzales, Steffen Schotthöfer, Cory D. Hauck
benchmarkcode/data similarity 0.56
Abstract

Linear radiation transport equations (RTEs) form the simulation foundations underpinning design and analysis tasks in nuclear engineering, inertial confinement fusion, medical imaging, and astrophysics, but resolving the high-dimensional phase space at engineering fidelity remains expensive enough that outer-loop workflows, such as design optimization, uncertainty quantification, and parameter sweeps, are routinely budget-bound on traditional solvers. Neural surrogates promise to relax this bottleneck by amortizing simulation cost across thousands of downstream queries, but the architectural choices and engineered inductive biases that make a surrogate accurate on one transport problem do not transfer straightforwardly across model families. We benchmark two parameter-matched neural surrogate architectures, the physics-attention Transolver and the multi-scale graph network Bi-Stride Multi-Scale MeshGraphNet (BSMS-MGN), as end-to-end approximations of the final-time particle concentration for the two-dimensional linear RTE on the canonical Lattice and Hohlraum benchmarks. An ablation across Fourier features and region-weighted training loss exposes strongly architecture-dependent inductive-bias preferences, indicating that design choices common to physics-informed surrogate workflows must be revisited per architecture rather than imported across model families, and that downstream utility depends on per-QoI sensitivity rather than a single field-level score. The model training recipe, training data, and evaluation pipeline are released alongside this paper to support reproduction, transfer to related transport problems, and evaluation as amortized forward-model components in larger outer-loop simulation workflows.

0.30

Learning the Dose Manifold: A Latent Diffusion Framework for Volumetric Dose Prediction in Automated Radiotherapy Treatment Planning

cs.CV ·2026-10-19 ·J. Boyer-Chammard, R. Vauclin, M. C. Biston, P. Maury, M. Gau +5 more
similarity 0.56
Abstract · 27 pages, 7 figures plus graphical abstract

Automated treatment planning (ATP) aims to reduce the unwarranted inter-planner variability of manual planning, while improving treatment quality and efficiency. Most ATP pipelines rely on the prediction of the achievable three-dimensional dose distribution for a given anatomy and the subsequent optimization of machine parameters to reproduce it. Diffusion-based methods are largely slice-wise due to the high dimensionality of radiotherapy data, and assume a one-to-one mapping between anatomy and optimal dose despite the multi-objective nature of treatment planning. They are evaluated on their ability to match reference doses and rarely on their integration in ATP frameworks. We present LaDose, a latent diffusion framework for fully volumetric dose prediction. An autoencoder learned on dose distributions, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU. Prescription values are represented as exact scalar vectors that bypass the image encoder, avoiding resampling and latent compression. Multiscale classifier-free guidance allows for the modulation of clinical trade-offs at inference, without retraining or additional labeled data. On 900 clinically delivered head-and-neck volumetric modulated arc therapy plans from five centers, LaDose reached a median absolute error of 1.18 Gy (1.4--1.8\% of the prescription) and was the only one of six frameworks free of systematic bias with respect to the reference distribution. Guidance scales acted predictably on target coverage and organ-at-risk sparing. Integrated with direct aperture optimization, the pipeline generated plans in 15.2 minutes; in a blinded review, senior clinicians rated 14 of 15 plans acceptable without editing.

0.12

Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning

cs.CV physics.med-phcs.LG ·2026-08-27 ·Ankit Bhattacharjee, Sougata Maity, Santam Chakraborty, Indranil Mallick
code/data similarity 0.56
Abstract · The paper consists of 22 pages, 4 figures, 6 tables. The end-to-end pipeline of Dose-PlanNet will soon be made available on the GitHub repos…

Automating prostate radiotherapy treatment planning is dosimetrically complex, particularly for extreme hypofractionated regimens. In this study, we introduce Dose-PlanNet, a physics-guided 3D deep learning architecture designed to predict dose distributions. This model's performance was evaluated on a cohort of patients treated in a prospective trial where two different dose fractionation regimens were employed. Dose-PlanNet achieved comparable target coverage ($D_{95}$), though statistical analysis revealed a marginal reduction in target homogeneity ($p<0.001$) offset. However the model achieved statistically significant improvements in high-dose organ-at-risk sparing ($p<0.001$). When evaluated against strict Prospective Randomized protocol volumetric constraints, automated plans met prespecified clinical acceptance criteria in $11$ out of $14$ Moderate Hypofraction Arm plans and $9$ out of $12$ Stereotactic Body Radiation Therapy Arm plans. This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy workflows while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.

0.36

Splat-based Metal Artifact Reduction in Cone-Beam CT via Polychromatic Modeling

cs.CV cs.GR ·2026-08-13 ·Kiseok Choi, Inchul Kim, Jaemin Cho, Hyeongjun Cho, Min H. Kim
published similarity 0.55
Abstract

Cone-beam computed tomography (CBCT) enables volumetric reconstruction from X-ray projections, but suffers from severe artifacts--especially beam hardening--when imaging materials with high attenuation such as metals. These artifacts arise from the polychromatic nature of X-rays and are not properly addressed by conventional monochromatic reconstruction algorithms. While recent neural representation-based methods offer improved reconstruction quality, they are computationally expensive and often impractical for deployment. We propose a novel physics-inspired, self-calibrating metal artifact reduction method that efficiently reconstructs 3D CBCT volumes while correcting beam hardening artifacts. Our method integrates a polychromatic X-ray projection model, material-dependent attenuation profiles, and system response modeling into a Gaussian Splatting framework. Unlike prior work, we eliminate the need for manual metal masks or strong prior assumptions, and we optimize both reconstruction parameters and X-ray spectral characteristics jointly during training. We further introduce a high-fidelity synthetic CBCT dataset generation pipeline validated on Monte-Carlo x-ray simulation toolbox and release new datasets with severe metal-induced artifacts to support the community. This is the first splat-based method for reducing beam hardening in CBCT. Extensive experiments on both synthetic and real-world datasets demonstrate that our method outperforms state-of-the-art approaches in artifact suppression and reconstruction accuracy.

0.54