CS Paper Radar

Constructive Port-Hamiltonian Energy Shaping Design of Dispatchable Virtual Oscillators in Grid-Forming Converters

Lu Gao, Lihui Yang, Feng Ji, Dong Liu, Longze Kou

eess.SY ·submitted 2026-09-01 14:56 UTC · v1

Abstract

Port-Hamiltonian (PH) theory offers a passivity-based framework for grid-forming control, yet conventional dispatchable virtual oscillator control (dVOC) does not naturally admit a dissipative PH realization, since its amplitude egulation, synchronization, and power dispatch are inherently coupled without a unified energy interpretation. This paper formulates the outer-loop dynamics as a dissipative PH system, thereby unifying amplitude regulation, synchronization, and power dispatch within one energy structure. The formulation rests on the key property that logistic-type radial regulation, characterized by an inherent saturation-like nonlinearity, permits an exact gradient decomposition compatible with the quadratic energy storage. On this basis, a unified shaped Hamiltonian is constructed, which encapsulates both amplitude restoration and power dispatch. Radial gain matching derived from this Hamiltonian yields explicit closed-form arameter inequalities that guarantee almost-global asymptotic stability and local exponential convergence. Moreover, tuning the power-error weighting coefficient actively shapes the energy landscape, thereby eliminating the undesirable low-voltage power-flow solution from the stationary set and ensuring convergence to the desired high-voltage equilibrium point. The Hessian singularity condition further provides the critical weight threshold that guarantees uniqueness of the high-voltage equilibrium. Numerical simulations validate the proposed method.

Closest papers

Nearest neighbours by meaning across the whole index.

Optimal Allocation of Grid-Forming Frequency Shaping Control

eess.SY ·2026-09-21 ·Zhaomin Lyu, Ding Zhang, Yan Jiang
similarity 0.54
Abstract

Various inverter-based control strategies have been proposed to improve frequency security for power systems with high renewable penetration. Among them, the grid-forming frequency shaping control is particularly promising due to its ability to shape the post-contingency aggregate system frequency dynamics into first-order with prescribed rate of change of frequency (RoCoF) and steady-state frequency deviation. Moreover, the shaped aggregate dynamics depends on the harmonic sum of all inverter transfer functions rather than on their distribution. In light of this, here we explore how to allocate shaping control resources to minimize the transient control effort needed to achieve ideal coherent dynamics. We formulate it as a constrained optimization problem by tackling two main difficulties. First, we make the squared $\mathcal{H}_2$ norm legitimate quantification of transient control cost under step power imbalances through a system transformation. Second, we simplify the $s$-domain constraint for Nadir elimination into a standard constraint that is easy to implement in optimization. The resulting non-convex optimization problem can be solved by existing successive convexification method. The effectiveness of the allocation has been verified on the modified Icelandic Power Network test case.

0.28

Harmonic Stability of Power Systems: A Control-Theoretic Definition and Assessment Criteria

eess.SY ·2026-08-20 ·N. Bhoir, A. Sarkar, J. E. Machado, J. Schiffer
similarity 0.54
Abstract

Harmonic interactions have become a defining dynamic stability phenomenon in converter-based power systems (CBPSs). However, a formalization of the notion of harmonic stability in the context of nonlinear dynamical systems is not available thus far. In this paper, we propose a definition of harmonic stability formulated as a combination of two standard stability notions, namely, bounded-input bounded-output (BIBO) and internal stability properties with respect to any nominal periodic trajectory. Moreover, we rigorously show that the local harmonic stability of any nominal periodic trajectory of nonlinear CBPSs is implied by the stability properties of its linear time-periodic (LTP) approximation. In addition, to enable computationally tractable stability assessment, we develop a framework based on harmonic state-space (HSS) representations of LTP models. In particular, we provide time-invariant linear matrix inequality (LMI) conditions to certify harmonic stability. The proposed methodology is illustrated on a grid-following converter system, where the HSS-based analysis numerically confirms harmonic stability around the periodic operating trajectory.

0.29

Internal-Model-Control-Based Virtual Admittance Emulation for Enhanced Grid-Forming Performance

eess.SY ·2026-09-18 ·Ruzica Cvetanovic, Lazar Stojanovic, Paolo Sbabo, Paolo Mattavelli, Massimo Bongiorno
similarity 0.52
Abstract

The large-scale integration of renewable energy into electrical power systems places a growing reliance on grid-forming converters (GFMs) to overcome critical stability and control hurdles. By emulating a slowly varying voltage source behind a tunable resistive?inductive impedance, GFMs enable precise setpoint tracking and vital grid support. In this regard, virtual admittance (VA)-based inner-loop control provides exceptional flexibility in shaping the converter's small-signal immittance at connection terminals, allowing for advanced GFM functionalities. This article addresses a novel internal-model-control-based VA approach, which inherently accounts for the effects of the inner current-control loop and the voltage feedforward. Unlike the state-of-the-art VA control, the proposed VA control ensures that, at frequencies outside the influence of outer loops, the converter's terminal admittance closely matches the target admittance, which is shown to be relevant for stability. It is revealed how, with the state-of-the art VA control, a small-signal instability in the harmonic range may arise if a low-pass filter with a high cut-off frequency is used for the voltage feedforward. However, the proposed VA control ensures stable operation regardless of this cut-off frequency. The methodology is experimentally validated using a laboratory prototype that features three-phase voltage-source converters.

0.21

Energy-optimal predictive control of discrete-time port-Hamiltonian systems: Closed-loop practical stability

eess.SY math.OC ·2026-09-22 ·Vaibhav Kumar Singh, Manuel Schaller, Timm Faulwasser, Karl Worthmann
similarity 0.51
Abstract · 20 pages and 4 figures, submitted to journal

We study a dissipativity-based model predictive control (MPC) scheme for energy-optimal constrained output stabilization of a discrete-time nonlinear SISO port-Hamiltonian system described by difference and differential representation. For the optimal control problem to be solved in each MPC step, we establish a measure turnpike behavior. The turnpike set in our work is obtained from the underlying port-Hamiltonian structure without assuming existence of steady-states or periodic orbits. In particular, unlike existing results which typically establish the turnpike property w.r.t. a controlled forward invariant set such as optimal steady-states or optimal periodic orbits, we do not require the turnpike set to be forward control invariant. For MPC, we establish recursive feasibility and show practical stability to the turnpike set w.r.t. the MPC closed loop leveraging both dissipativity and the port-Hamiltonian structure. Finally, we demonstrate our results using two numerical examples.

0.49

Optimal energy conversion -- A port-Hamiltonian approach

eess.SY ·2026-10-15 ·Guanru Pan, Karl Worthmann, Manuel Schaller, Timm Faulwasser
similarity 0.50
Abstract

This paper studies optimal energy conversion in port-Hamiltonian systems. We analyze state- and control-constrained finite-horizon optimal control problems that maximize energy conversion efficiencies. Under suitable reachability conditions, we show that the asymptotic optimal efficiencies exist and coincide with the corresponding optimal cyclic efficiencies. For a class of port-Hamiltonian systems describing coupled storage-conversion components, we further derive intrinsic limits on achievable energy conversion and establish a generalized Carnot-type efficiency bound. Our results provide an optimal-control framework connecting asymptotic optimal operation, cyclic operation, and fundamental efficiency limits for port-Hamiltonian systems.

0.20

Stability Transfer for Autonomous Systems via Higher-Order Taylor-Truncated Lyapunov Certificates

eess.SY math.OC ·2026-10-13 ·Jose D. Hoyos, Zehui Lu, Shaoshuai Mou
published similarity 0.50
Abstract

We develop analytical sufficient conditions for certifying the local asymptotic stability of nonlinear autonomous systems based on Lyapunov functions derived from their finite-order Taylor polynomial approximations. This approach translates the stability analysis problem from the original nonlinear dynamics to a more computationally tractable polynomial domain. The derived conditions allow for the explicit calculation of a guaranteed inner approximation of the region of attraction ($\mathrm{ROA}$). We show how sum-of-squares (SOS) programming and grid search can be used to systematically search for polynomial Lyapunov functions that yield a large certified threshold radius and extract a certified invariant set inner approximation of the $\mathrm{ROA}$ of the nonpolynomial original system. The framework is then applied to a control tuning problem: finding reduced-effort Linear Quadratic Regulator (LQR) controllers that ensure that a given initial state of interest belongs to the certified $\mathrm{ROA}$ of the nonpolynomial closed loop system. The effectiveness of the overall methodology is demonstrated using a pendulum with nonlinear damping and a nonlinear control system.

0.29

Data-Driven Static Output-Feedback Control for Multi-Agent Systems

eess.SY math.OC ·2026-10-02 ·Paul Serna-Torre, Adam Sedlak, Patricia Hidalgo-Gonzalez
similarity 0.50
Abstract

This work proposes a data-driven framework that synthesizes output-feedback control for linear time-invariant multi-agent systems (MAS). We first develop two algorithms that use offline data samples of state and input trajectories to determine a Nash equilibrium (NE) for MAS. Next, we formulate a semidefinite program that, given the NE solution, computes the static output-feedback controllers for the agents in MAS. Compared to prior work, virtues of our framework include weaker controllability assumptions, the absence of online information and data-driven estimation of states. Next, we use the proposed framework to design control schemes for voltage and frequency regulation for nonlinear multi-nodal electrical networks with grid-forming and grid-following inverters. Thus, compared to prior work that implements their data-driven frameworks in small-scale numerical examples, we validate the performance of our data-driven framework in high-fidelity nonlinear models of MAS. This implementation in realistic MAS provides insights that small-scale numerical examples may fail to capture. Results show successful grid stabilization and provision of regulation services from the inverters in the grid using our proposed framework. It can attain up to 78% less overshoot and 30% faster settling time than traditional strategies such as proportional-integral control.

0.30

Grid-forming Control of Offshore Wind through a Diode-Rectifier HVDC System: a 2 GW Case Study

eess.SY ·2026-11-08 ·Ishi Nigam, Saif Alsarayreh, Tuanku Badzlin Hashfi, Miloš Cvetković, Joris van Doorn +1 more
similarity 0.49
Abstract

Diode-rectifier-unit (DRU)-based high-voltage direct current (HVDC) transmission considerably reduces the volume and weight of the offshore converter platform for remote wind farms and, hence, its cost, but shifts the task of forming and regulating the offshore AC network to the wind-turbine converters. This paper examines which grid-forming control strategy is the most suitable for DRU power transfer. The DRU commutation relationship shows that the delivered active power depends on the offshore voltage magnitude (but not on the converter voltage angle), so the angle-based active-power loop of virtual synchronous machine control is not closed through the rectifier. A $P-V/Q-ω$ grid-forming architecture, which regulates active power via the voltage magnitude and derives frequency from the reactive power error, is therefore adopted. Electromagnetic transient simulations of a 1GWaggregated grid-forming turbine on a 66 kV collector network with a $\pm$525 kV bipolar DRU link show that the commanded power is delivered over 800 to 1000MW with the offshore voltage held near nominal. The paper also examines how grid-forming operation changes the allocation of control duties within the Type-4 turbine: once the grid-side converter forms the network, DC link regulation must move to the machine-side converter, which limits the achievable bandwidth of the DC-link control. Extending the system to 2 GW with two 500 MW grid-following units achieves full power transfer in simulation, but with the grid-forming converter loaded beyond its continuous rating and a steady-state offshore frequency deviation of approximately 1.8 Hz.

0.34