CS Paper Radar

Novel Methods for Catheter and Guidewire Segmentation in X-ray Fluoroscopy under a Federated Learning Setting

Chayun Kongtongvattana

cs.CV cs.AI ·submitted 2026-09-06 23:44 UTC · v1
benchmark

Abstract

Endovascular procedures rely on real-time manipulation of thin instruments, catheters and guidewires, under X-ray fluoroscopy guidance, where accurate visual analysis is essential for procedural safety. Learning-based methods are constrained by structural complexity, data scarcity, and privacy regulations precluding centralised training across institutions. This thesis presents a structure-aware federated learning framework for catheter and guidewire analysis, with four contributions evaluated on real-animal and phantom data. A benchmark dataset, CathAction, is introduced for catheterisation analysis, with over 600,000 annotated frames and 40,000 segmentation masks. A shape-sensitive loss transforms masks into signed distance maps compared in a structural feature space, improving Dice coefficient by up to 2.9 points across five backbones. This is extended to federated learning with shape-sensitive loss, preserving geometric consistency under heterogeneous client data and outperforming federated averaging by up to three points in mean intersection-over-union as clients scale from four to eight. Federated learning with projected gradient descent adds adversarial optimisation, raising mean intersection-over-union by over ten points on real-animal data. Finally, a structure-aware diffusion framework synthesises catheter and guidewire video sequences, combining structural supervision with a domain-adaptive reconstruction objective, reducing Frechet video distance over a strong baseline while maintaining visual fidelity. Incorporating synthetic sequences into federated training raises the Dice score from 44 to 51 percent under data scarcity, with gains across four held-out sites. Together, these contributions advance privacy-preserving catheter and guidewire analysis, supporting collaborative training without centralising patient data or large amounts of manual annotation.

Comment
PhD Thesis, University of Liverpool. 163 pages

Closest papers

Nearest neighbours by meaning across the whole index.

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.65
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

Personalized and Adaptive Federated Learning for Canine Cardiomegaly Keypoint Prediction

eess.IV cs.CRcs.CV ·2026-11-13 ·Jialu Li, Youshan Zhang, Honggang Wang
similarity 0.64
Abstract

In the field of medical imaging, limited data and cross-institutional heterogeneity remain major challenges for training robust deep learning models. Federated learning (FL) has emerged as a promising approach that enables collaborative training across institutions while preserving data privacy by keeping datasets local. In this work, we propose a structure-aware personalized and adaptive federated learning framework, PAFL, for automatic vertebral heart score (VHS) estimation and cardiomegaly classification from canine thoracic X-rays. Our method treats the task as anatomical keypoint prediction followed by geometry-based VHS computation, introducing implicit structural consistency and improving interpretability. To address cross-institutional heterogeneity, we adopt a parameter-decomposed architecture that separates shared feature representations from client-specific adaptation modules. Furthermore, we introduce an adaptive, quality-aware aggregation strategy that dynamically weights client contributions based on both dataset size and model quality, thereby enhancing robustness to non-IID data distributions. Experimental results demonstrate that the proposed PAFL framework improves models' predictive performance compared to isolated training and to conventional and existing personalized federated learning (PFL) methods. Our results demonstrate the potential of integrating structure-aware modeling with PFL for reliable and interpretable medical image analysis.

0.13

Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

cs.CV ·2026-09-22 ·Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez
published similarity 0.63
Abstract · 12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

0.19

FleXray: Universal Clinical X-ray Segmentation

cs.CV cs.AI ·2026-09-22 ·Victor Ion Butoi, Vivek Gopalakrishnan, John V. Guttag, Adrian V. Dalca, Neel Dey
similarity 0.63
Abstract · 35 pages, 12 figures, 10 tables. Code, models, data, and a browser-based demo at https://flexray.csail.mit.edu

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .

0.27

Uncertainty-Aware Compositional Localization and Placement Assessment of Catheters and Tubes in Chest X-Rays

eess.IV cs.CVcs.LG ·2026-08-11 ·Harshil Lodhiya
similarity 0.62
Abstract · 21 pages, 8 figures Included declaration for paper is under consideration at Pattern Recognition Letters

Assessing catheter and tube placement on chest X-rays is safety-critical yet tedious and error-prone. Current deep learning methods either classify placement globally -- losing track of which device is where -- or segment all devices into a single mask, making per-device assessment impossible when catheters overlap. We introduce UCompCXR, a compositional framework that detects local catheter fragments, associates them into device instances via graph-based clustering, fuses per-fragment tip predictions through precision-weighted Gaussian estimation, and classifies placement per device. On the RANZCR CLiP dataset (30,083 images, 5-fold patient-level CV with bootstrap CIs), UCompCXR detects 26% more devices than a strong multi-task baseline sharing the same MobileNetV3 backbone, with 75% fewer false positives and well-calibrated tip uncertainty (95% coverage = 0.948). The aggregate tip error rises -- but only because the model finds devices the baseline misses entirely, especially nasogastric tubes. On matched devices, catastrophic localization failures drop substantially. At 2.27M parameters in a single forward pass, the model is deployable on resource-constrained clinical hardware.

0.40

ARC-CT: Anatomy-Routed Contrastive Vision-Language Learning for 3D Chest CT

cs.CV cs.AI ·2026-08-28 ·Huseyin Umut Isik, Mehmet Alp Ozaydin, Sila Kurugol, Şeyda Ertekin
publishedcode/data similarity 0.62
Abstract · Accepted to the Thoracic Image Analysis (TIA) Workshop at MICCAI 2026

Contrastive vision-language learning uses paired chest CT volumes and radiology reports to learn abnormality classifiers without manually annotated labels. However, two characteristics of chest CT challenge conventional global contrastive learning. First, many critical abnormalities are small or anatomically localized, and pooling an en- tire volume into a single embedding may dilute their visual evidence. Second, the standard contrastive objective treats every other scan in a batch as a negative. Because many chest CTs share abnormalities, this objective incorrectly pushes co-positive pairs apart. We propose Anatomy-Routed Contrastive Learning for 3D Chest CT (ARC-CT), a region-aware framework that addresses these limitations using only la- bels extracted from reports by an LLM, with no manual annotations or bounding boxes. ARC-CT combines three components: (1) an Anato- myQFormer localizing evidence via queries constrained by automatically generated organ masks; (2) a label-Jaccard soft InfoNCE objective in- tegrating the standard one-hot target with the label-set overlap of each pair, which reduces false-negative penalties between studies that share clinical findings; and (3) an organ-level alignment loss connecting mask- pooled visual features to organ-specific report text extracted offline with a large language model. ARC-CT achieves a 0.86 mask-free macro AUC across 18 abnormalities using a compact 3D ResNet-18 backbone. Over- all, ARC-CT outperforms both comparable efficient baselines and sev- eral larger transformer models. Our code and weights are available at https://github.com/arc-ct/arc-ct.

0.64

Structure-aware Keypoint Localization for Videofluoroscopic Swallowing Study

cs.CV ·2026-10-06 ·Kai Zhou, Chuanshen Chen, Runhao Zeng, Meng Dai, Yifan Yang +4 more
publisheddatasetcode/data similarity 0.62
Abstract · Accepted by ICME 2026 Oral

Videofluoroscopic Swallowing Study (VFSS) is one of the gold standard for diagnosing swallowing disorders, providing dynamic X-ray imaging of the swallowing process. Automated kinematic analysis in VFSS relies fundamentally on precise anatomical keypoint localization. However, existing studies focus on limited keypoints (e.g., cervical vertebrae or the hyoid) and overlook critical regions such as the soft palate, while annotating only active swallowing segments and ignoring abundant non-swallowing data, resulting in poor data efficiency. Moreover, leveraging this unlabeled data via standard semi-supervised learning is suboptimal, as generic methods are prone to spatial bias. In medical X-rays with fixed layouts, models tend to memorize absolute coordinates rather than understanding anatomical structures. To tackle these challenges, we introduce VFSSKep, a novel dataset that extends annotations to the soft palate and incorporates large-scale unlabeled data. We further propose S$^3$KL, a Structure-aware Semi-Supervised Keypoint Localization framework designed to overcome spatial bias. It integrates a Structure-Aware Learning strategy to extract high-resolution structural cues for structure-aware representation learning, and a Structural Representation Consistency Learning strategy with block shuffling to enforce invariant structural recognition. Experiments show our method achieves state-of-the-art semi-supervised performance, even with unlabeled and 25% labeled data surpassing fully supervised learning with 100% labeled data. Code and data will be made publicly available at: https://github.com/kaai520/S3KL.

0.42

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

cs.CV cs.AI ·2026-10-29 ·Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar
similarity 0.61
Abstract · 7 pages, 2 figures, 3 tables

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3-3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

0.18