CS Paper Radar

On the Removal of Artifacts of Known-Shape from Noisy Signals

Alessandro Schaer, Henrik Maurenbrecher, George Chatzipirpiridis, Hamdi Torun

eess.SP ·submitted 2026-09-07 08:31 UTC · v1

Abstract

A general method for the estimation and removal of quasi-periodic, artifact-like disturbances from single channel measurements is presented. The method is based on a wavelet template and data-driven template extraction from single channel, noisy signals. The method is tested on an example application in modern neurology. The method is compared to an autoencoder, trained and deployed under idealized conditions, thus acting as reference system. It is found that the proposed method yields signal estimates with median root mean squared error improvement of 33% compared to the baseline, which is 4% more than the autoencoder, while relying on fewer assumptions and parameters, and without the need for any training data.

Comment
Submitted to Healthcare Technology Letters

Closest papers

Nearest neighbours by meaning across the whole index.

Time-Window Noise2Noise: Self-Supervised Blind Denoising of Mechanical Vibration and Impact Signals

eess.SP ·2026-08-25 ·Vinicius S. Vianna, Tiago H. Machado, Ilmar F. Santos
similarity 0.55
Abstract · 24 pages, 8 figures, 14 tables. Submitted to the Journal of the Brazilian Society of Mechanical Sciences and Engineering (Springer)

Vibration and impact measurements in mechanical systems are invariably corrupted by noise, which degrades every quantity derived from them, such as modal parameters and contact forces. Classical filters rely on assumptions about the noise or the signal, and linear filters cannot remove the noise that shares the frequency band of the structural response. This work presents Time-Window Noise2Noise (TWN2N), a self-supervised method for blind denoising of signals produced by deterministic mechanical systems. The method requires neither a clean reference signal nor paired noisy observations, nor a measured noise variance or distribution: by reconstructing each time instant from its temporal neighborhood while masking the instant itself, a compact autoencoder is encouraged to exploit the coherent temporal and multichannel structure of the measurement rather than the noise. The formulation requires no model of the system and is assessed on two benchmarks with exactly known ground truth: the impulse response of a linear 3-degree-of-freedom system and a nonlinear Hunt-Crossley impact. Over repeated realizations, TWN2N exceeds a zero-phase low-pass filter with oracle cutoff at low and moderate input signal-to-noise ratio (SNR) and gives the largest gain inside the structural band, which a linear filter largely preserves, among the Savitzky-Golay and wavelet references; the advantage vanishes at high input SNR and under brown noise. The benefit propagates to identification: the damping ratio of the weakest mode, overestimated several-fold on the raw signals, is recovered close to its reference value after denoising.

0.31

Automated Artifact Removal in EEG Age Prediction: A systematic comparison

eess.SP ·2026-09-25 ·Davoud Hajhassani, Paul-Adrien Graignic, Bruno Aristimunha, Apolline Mellot, Tom Mariani +6 more
similarity 0.54
Abstract

Automated EEG artifact removal may improve downstream analysis but can also alter predictive information. We benchmarked nine automated artifact removal methods against a common no-artifact-removal baseline for cross-dataset EEG age prediction. We introduce Signal Quality Index (SQI)-guided GEDAI, which leverages local signal-quality assessment to restrict correction to the channel--epoch pairs requiring intervention. Three deep neural architectures were trained on TUEG and evaluated without target-domain fitting on ds005385, LEMON, and TDBRAIN. Across this setting, GEDAI and SQI-guided GEDAI were the only methods with consistent gains over baseline in age prediction performance across all datasets and architectures ($Δ$MAE $=-0.77/-0.64$ years, $ΔR^2=+0.083/+0.072$, respectively). The remaining methods were neutral or detrimental on average ($Δ$MAE $=+0.22\pm0.16$ years, $ΔR^2=-0.023\pm0.016$ across methods). The two GEDAI-based methods achieved closely matched performance, while SQI guidance reduced the median modification ratio from $74.78\%$ to $42.80\%$. These findings show that curation benefits are method-dependent and establish SQI guidance as a more selective operating point, leaving more of the original EEG unchanged and limiting the potential loss of neural activity while retaining most of GEDAI's predictive benefit.

0.34

SSEMG-Net: A Spectrogram-Based Mamba Network for Surface Electromyography Denoising

eess.SP ·2026-09-10 ·Cheng-Han Shih, Kuan-Chen Wang, Kai-Chun Liu, Ping-Cheng Yeh, Yu Tsao
published similarity 0.53
Abstract · 6 pages, 3 figures, 2 tables. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society …

Electrocardiogram (ECG) artifact contamination frequently occurs in surface electromyography (sEMG) when muscles are recorded near the heart. Existing neural network (NN)-based approaches typically perform waveform-level end-to-end denoising with pointwise losses, but often fail to preserve the spectral structures of sEMG. In addition, these models do not exploit the prior knowledge that ECG mainly distorts the low-frequency band of sEMG. We propose SSEMG-Net, a spectrogram-domain model that explicitly captures sEMG-ECG interactions using a bidirectional Mamba backbone and a dual-head decoder for magnitude masking and wrapped-phase estimation. The magnitude masking module is physiologically aware, restricting denoising to the low-frequency sub-band where ECG activity predominates. Experimental results demonstrate that SSEMG-Net achieves superior signal quality and lower feature-extraction error compared to prior methods, underscoring its potential for clinical applications where preserving sEMG spectral features is essential.

0.44

Cyclostationary Phase Conditioning for Medical Time Series Diffusion

cs.LG cs.AIeess.SP ·2026-09-28 ·Samuel Ruiperez-Campillo, Michele Copetti, Jorge da Silva Goncalves, Sonia Laguna, Thomas Hofmann +1 more
similarity 0.50
Abstract · 43 pages, 16 figures, 21 tables

Many physiological time series, such as cardiac and brain recordings, exhibit cyclostationarity: their statistics vary periodically with an underlying cycle phase. Corruption from motion, poor contact, and physiological interference obscures morphology needed for diagnosis, making signal restoration essential. Existing diffusion approaches condition on corrupted observations alone and must learn cyclic structure implicitly. We instead propose two inductive biases which encode cyclostationarity: a shift-covariant wavelet representation and dense per-sample phase conditioning inferred from the corrupted input. We further introduce a training-free cyclostationarity index that quantifies phase structure and predicts when phase conditioning will help. Finally, we propose antithetic coupling of reverse trajectories to reduce sampling variance while achieving comparable performance with fivefold fewer network evaluations. Across modalities, our results show that explicitly encoding measurable cyclic structure improves physiological time-series restoration.

0.45

Time-warping estimation via stationarity-based learning of the de-warped signal

cs.LG stat.ML ·2026-09-15 ·Corentin Presvôts, Adrien Meynard
publishedunusual similarity 0.50
Abstract

Time-warping estimation is a fundamental problem in signal processing with applications in bioacoustics, radar, and biomedical analysis. This paper introduces a Time-Warping Estimation Trainable (TWET) model for estimating timewarping functions from a single observation. The proposed approach formulates time-warping estimation as a stationarization problem in the wavelet domain and leverages a hierarchical dilated convolutional architecture to estimate the time-warping functions. A differentiable stationarity criterion is introduced for end-to-end optimization. TWET is compared with existing approaches. Experimental results show improved deformation reconstruction accuracy together with significantly reduced computation time, making the framework compatible with low-latency applications.

0.45

Time-Varying Spiky Wave-Shape Functions for Non-Stationary Signal Decomposition

eess.SP ·2026-08-26 ·Marcelo A. Colominas, Hau-Tieng Wu
similarity 0.49
Abstract

We propose a novel framework for decomposing nonstationary spiky signals. Unlike classical adaptive non-harmonic models, which represent signals as amplitude- and frequency-modulated (AM--FM) oscillations, the proposed model is designed for signals whose dominant structures are highly localized, impulsive, or spike-like, and contains physiological variability, which is challenging to be modeled as AM--FM representations. Representative examples include electrocardiogram (ECG) complexes, epileptic electroencephalogram (EEG) transients, and other pulse-like physiological signals. We first introduce a fixed-waveform model for repetitive spiky structures and then extend it to accommodate cycle-to-cycle waveform variability. The resulting algorithm, termed \emph{Spiky Shape-adaptive Mode Decomposition} (SSAMD), estimates waveforms in the Fourier coefficient domain. Fourier coefficients are first estimated via local regression and then regularized by exploiting their low-dimensional manifold structure. Specifically, we combine a PCA-based parametrization with an entropy regularization acting on the singular-value spectrum of the coefficient matrix, promoting morphological consistency while preserving structured waveform variability. The proposed framework is flexible and overcomes the limitations of existing models. We validate the method on synthetic and real biomedical signals, including ECG with atrial fibrillation, epileptic EEG, and trans-abdominal maternal ECG. Experimental results demonstrate effective denoising, waveform tracking, decomposition, and segmentation, while preserving physiologically meaningful morphological variations.

0.25

From Perturbation Sensitivity to Sparse Autoencoder Feature Interpretation: An EEG Foundation-Model Case Study

cs.LG ·2026-09-28 ·Yucong Cao, Chenqi Li, Tingting Zhu
similarity 0.49
Abstract · Revised version with expanded experimental analysis and discussion of limitations

Sparse autoencoders (SAEs) split a model's internal activity into many sparse units, or latents, and a latent is often named after a concept when removing that concept from the input changes its activity. We identify a consequential confound in this inference: if removing the concept changes the input more than the comparison edit does, a larger response may reflect a larger edit rather than the concept. Brain-signal (electroencephalography, EEG) models provide a controlled test, because how much an edit changes the EEG input can be measured directly. We measure the SAE response as the change in how often each latent is active, averaged over all latents. Across 27 combinations of model, dataset, and layer, removing the 8--12 Hz alpha band changes this response 7.33 times as much as removing an equally wide 30--34 Hz control band, but it also changes the signal far more. Matching the two edits per trial on squared time-domain distortion lowers the mean ratio to 1.42, with 19 of 27 combinations above one. Matching thus substantially reduces, but does not eliminate, the alpha--control contrast. The residual supports relative sensitivity under this single control, not general spectral specificity or an individual alpha-representing latent. We use an evidence-to-claim map to separate what this comparison supports from stronger claims of specificity and feature semantics.

0.22

Beyond Reconstruction: A Unified Framework for Trustworthy and Explainable EEG Artifact Removal Evaluation

eess.SP cs.AI ·2026-11-16 ·Phat Lam, Hung Nguyen, Lam Pham, Huy Phan, Dat Tran +3 more
similarity 0.48
Abstract · IEEE journal manuscript under review

Deep-learning methods have achieved strong performance in EEG artifact removal, but evaluation remains dominated by reconstruction metrics such as error, correlation, and signal-to-noise ratio. Although these metrics assess similarity to clean EEG, they do not establish whether models effectively suppress artifacts, preserve neural activity, or provide reliable explanations. To address these limitations, we propose TriX-EEG, a three-level framework for trustworthy and explainable EEG artifact removal. Level 1, Signal Validity (SV), evaluates reconstruction quality and neural band-power preservation. Level 2, Removal Faithfulness (RF), assesses the removed component through artifact error and residual artifact/neural leakage. Level 3, Explanation Reliability (ER), examines model behavior through temporal alignment, causal relevance, and stability. We evaluate TriX-EEG using nine published neural denoisers across three public benchmarks derived from EEGDenoiseNet and the PhysioNet Motion Artifact Contaminated EEG Dataset, covering EOG, EMG, and motion artifacts. Results show that reconstruction metrics alone are insufficient for trustworthy denoiser assessment: RF complements it by revealing whether errors stem from residual artifact or suppressed neural activity, while ER captures distinct aspects of explanation behavior, supporting joint evaluation of three aspects within a unified framework rather than reliance on any single factor. External validation on an independent EEG/EOG dataset and the BCI Competition IV-2a motor-imagery dataset further demonstrates broadly consistent rankings under dataset shift. Higher-ranked denoisers generally preserve more task-relevant information or cause less downstream performance degradation. Overall, TriX-EEG provides a comprehensive basis for EEG denoiser assessment, encouraging models that are not only accurate but also faithful and explainable.

0.27